DERUI · INDUSTRIAL-GRADE RELIABILITY
150L Humidity Heat Test Chamber for Component Reliability Testing
Give electronic assemblies, sensors and automotive components room for a repeatable temperature and humidity test. The DR-H201-150L (also configured as a 150L programmable climatic test chamber or damp-heat environmental chamber) combines a 500 × 500 × 600 mm SUS304 workspace with industrial-grade refrigeration, helping your lab run 1,000-hour validation cycles without drift or unplanned stoppage.
500×500×600 mm precision workspace
Selectable down to −70°C (+150°C max)
Zero-excuse overseas lab support
Start with your sample and target profile—not just the lowest temperature on a brochure. Share your assembly dimensions and active heat (watts) to receive a verified configuration and real factory test curve.
Room for the Assembly—and the Air Around It
The 500 × 500 × 600 mm internal chamber provides a nominal 150 L volume for components and fixtures that need more space than a compact cabinet. A useful layout accommodates the complete assembly, its support and test leads while leaving paths for conditioned air. Filling every available centimetre is not the same as creating a reliable test arrangement.
Electronics and sensors
Expose PCBs, connectors and control modules to specified temperature and moisture conditions. Include cable routing and any powered monitoring in the layout.
Automotive components
Evaluate assemblies, housings and material interfaces against a defined environmental procedure. Choose the profile around the component requirement, not an assumed universal automotive cycle.
Materials and laboratory work
Use controlled climatic exposure for conditioning and comparative studies. Keep specimen location and loading consistent when comparing batches or design changes.
A smaller load may suit the 80L temperature and humidity chamber. For a fixture that cannot fit with adequate circulation space, discuss a larger cabinet through our temperature test chamber range. Moving up in volume should solve a real loading problem, rather than simply add unused space.
Choose the Temperature Option Around Your Test
All four DR-H201-150L tiers share the same 500 × 500 × 600 mm workspace, ±0.5°C temperature fluctuation and 20%–98% RH humidity system. The price difference comes strictly from the refrigeration architecture required to reach your lowest setpoint under load:
| Temperature option | Cooling architecture | Selection focus & typical test scope |
|---|---|---|
| 0°C to +150°C | Single-stage hermetic compressor | Most economical tier for steady-state damp heat (IEC 60068-2-78, 40°C/93% RH, 85°C/85% RH) without sub-zero stages. |
| −20°C to +150°C | High-efficiency single-stage system | Entry laboratory standard for consumer electronics, packaging and basic cold storage combined with damp heat. |
| −40°C to +150°C | Heavy-duty / binary refrigeration | Most popular R&D tier for automotive modules (ISO 16750), cyclic damp heat (IEC 60068-2-30) and powered PCB assemblies. |
| −70°C to +150°C | Dual-stage cascade refrigeration | Deep-cold configuration for aerospace, defense (MIL-STD-810H), telecom 5G and cold-start validation requiring rapid pull-down. |
The humidity range is 20% to 98% RH within the applicable temperature–humidity operating envelope. For a programme combining dry cold, heat and damp heat, identify which stages require humidity control so the configuration review covers the complete sequence.
Control the Exposure. Keep the Test Traceable.
The chamber brings temperature control, moisture regulation and forced-air circulation into a programmable system. Its value is not simply reaching a number on the display: it is giving your team a practical way to set up, run and document the intended exposure.
Programmable operation
Organise temperature and humidity exposure around the required stages. Define transitions, dwell periods and repeat cycles in the test programme so operators can follow a consistent sequence.
Forced-air circulation
A circulating air system distributes the conditioned environment through the workspace. Leave supply and return paths clear; a tightly packed fixture can change the conditions around individual specimens.
Computer connection and records
The published controller features include LAN computer connection and USB export functions. Discuss the required data fields, CSV/PDF export format and sensor arrangement when defining your recordkeeping needs.
Free live heat-load & airflow calculation
Powered PCBs and automotive modules emit heat that slows pull-down rates and destabilizes 85°C/85% RH runs.
Share your maximum heat dissipation in watts and operating duty cycle—DERUI engineers will calculate the exact refrigeration margin before you order.
Real empty-load curve & T-RH envelope chart
No chamber achieves 20%–98% RH at every extreme temperature.
Request our official combined Temperature–RH Operating Envelope Chart plus a 9-point mapping log exported from a recently built DR-H201-150L on our factory floor.
Why Our 150L Chamber Runs 1,000 Hours Straight Without Drift or Leaks
Low-cost chambers cut corners behind the sheet metal—using refurbished compressors, spot-welded liners that rust, and thin insulation that sweats on your lab floor. Here is what goes inside every DERUI DR-H201-150L to support long-duration validation:
❄️ Original French Tecumseh / German Bitzer Compressors
Paired with Danfoss solenoid valves and Saginomiya expansion valves to guarantee stable 0.7–1.0°C/min cooling rates even after years of thermal cycling.
Cheap alternatives: Unbranded domestic compressors that lose cooling capacity below −30°C after 6 months of heavy lab use.
🛡️ Full-TIG Welded SUS304 Stainless Inner Liner
100% seamless continuous welding backed by 100 mm high-density polyurethane foam insulation prevents moisture migration into the cabinet walls during 98% RH tests.
Cheap alternatives: Spot-welded seams sealed with silicone caulk that peel under +150°C heat and leak steam.
💧 Isolated Stainless Boiler Humidification + Auto Water Feed
External steam humidification with dry-burn protection and automatic water level control delivers +2% / −3% RH uniformity without spraying water droplets onto live PCBs.
Cheap alternatives: Open shallow water pans that scale up rapidly and contaminate test specimens.
🔒 12-Point Hardware Safety Interlocks
Independent hardware over-temperature limiter, compressor high/low pressure trips, phase-sequence protection and earth-leakage breaker protect high-value samples during unattended weekend runs.
Cheap alternatives: Software-only temperature limits that fail if the main SSR solid-state relay fuses closed.
DR-H201-150L Technical Specifications
| Item | Published specification |
|---|---|
| Model / nominal volume | DR-H201-150L / 150 L |
| Internal chamber dimensions | 500 (W) × 500 (D) × 600 (H) mm |
| Exterior / packing reference size | 1050 × 970 × 1650 mm (confirm exact installation footprint and 600 mm service clearance on the approved GA drawing) |
| Temperature options | 0 / −20 / −40 / −70°C low-temperature limit; +150°C upper limit |
| Temperature uniformity | ≤2°C, no-load |
| Temperature fluctuation | ±0.5°C, no-load |
| Humidity range | 20%–98% RH within the applicable combined operating envelope |
| Humidity uniformity | +2% / −3% RH |
| Humidity fluctuation | ±2% RH |
| Heating rate | 1.0–3.0°C/min (average, no-load) |
| Cooling rate | 0.7–1.0°C/min (average, no-load) |
| Time setting range | 1–60,000 min |
| Cable access | Left-side test hole (standard Ø50 mm / Ø100 mm with silicone plug) for external power or signal cables |
| Observation window options | 210 × 275 mm or 395 × 395 mm effective viewing area with anti-sweat heater |
| Power supply matching | Standard 220V/50Hz or 380V/50Hz; custom 110V/220V/480V 60Hz configurations available for global laboratory grids |
Heating and cooling rates depend on the selected configuration, temperature interval, ambient conditions and load. Use a project-specific acceptance profile to establish the performance required for your application.
Map the Chamber to the Test Procedure & Field Cases
Use the standard and product specification to define the profile. The chamber supports environmental exposure only when its selected configuration covers every required setpoint, transition and tolerance.
| Reference | Typical use | Confirm before testing |
|---|---|---|
| IEC 60068-2-30 | Cyclic damp heat | Edition, cycle, transitions, condensation and recovery |
| IEC 60068-2-78 | Steady-state damp heat | Temperature, RH, duration, stabilization and evaluation |
| MIL-STD-810H Method 507.6 | Tailored humidity exposure | Procedure, climatic cycle, specimen operation and acceptance criteria |
| JESD22-A101 / A100 | Electronic-device moisture testing | Applicable method, bias interfaces, safety and monitoring |
Define the exposure
Include temperature, RH, transitions, dwell periods and specimen operating state in the test request.
Define the measurement
Distinguish chamber-air temperature from specimen temperature, and specify when exposure timing starts.
How Engineering Teams Worldwide Configure the DR-H201-150L
🇩🇪 Germany · Automotive Electronics
IEC 60068-2-30 Cyclic Damp-Heat: Configured a −40°C to +150°C unit with dual Ø100 mm silicone-sealed cable ports for 24 powered CAN-bus sensor modules (120 W active heat). Programmed pre-heating eliminated ramp-up condensation short circuits and passed OEM audit on the first run.
🇲🇽 Mexico · PCB & Connector Assembly
1,000-Hour 85°C/85% RH Steady-State: Upgraded from overcrowded 80 L units to a −20°C to +150°C 150 L chamber with direct RO water feed holding 60 harness connectors. Improved workspace airflow uniformity from ±3.1°C down to ±0.6°C with zero manual refills over 42 days.
🇻🇳 Vietnam · Telecom & 5G Hardware
MIL-STD-810H Thermal Cycling: Deployed a −70°C to +150°C cascade system with reinforced 50 kg shelves for 18 kg die-cast aluminum RF router housings. Achieved repeatable 1.0°C/min pull-down to −55°C despite high thermal mass, saving $4,200/month in external lab fees.
Choose 150L Only When the Load Fits
80L chamber
Better suited to smaller loads when footprint and lower conditioned volume are priorities.
150L chamber
Provides a 500 × 500 × 600 mm workspace for medium-sized component and fixture layouts while maintaining at least 1/3 unobstructed airflow clearance.
408L or larger
Review a larger cabinet when the complete loaded envelope or required airflow clearance cannot fit the 150 L workspace.
Define Supply, Acceptance & Zero-Excuse Overseas Support
A useful equipment proposal connects the cabinet to your laboratory. Before ordering, bring the configuration, utilities, documentation and acceptance requirements into one supply scope so purchasing and engineering can verify every detail.
| Project decision | What to include in the discussion |
|---|---|
| Equipment and interfaces | Temperature option, specimen supports, cable access, monitoring and data requirements; distinguish included items from options. |
| Laboratory preparation | Destination power supply, room conditions, heat rejection, RO/distilled water quality, drainage, access route and service space. |
| Acceptance records (FAT) | Setpoints, 9-point sensor locations, empty or loaded condition, stabilization, measurement duration and pass/fail limits. |
| Handover and support | Required operating instructions, electrical drawings, training, warranty coverage, spare-parts kit and support contact arrangements. |
Zero-Excuse Overseas Support: Written in Numbers, Not Vague Promises
We know your biggest concern when importing testing equipment is downtime during a critical customer audit. Here is exactly how DERUI protects your laboratory across time zones:
2-Year Free Consumable & Spare Parts Kit Included
Shipped inside your crate at zero extra cost: extra SSR solid-state relays, wet-bulb wicks, silicone port plugs, fuse set and water float switch so your local technician can fix 90% of routine wear items in 15 minutes.
30-Min Direct Engineer Video Diagnostics
No chatbots. Message our WhatsApp hotline (+86 135 2795 8363) with any alarm code and get a live video walk-through with a senior refrigeration and PLC engineer within 30 minutes on workdays.
72-Hour Pre-Shipment Continuous Burn-In Video
Your DR-H201-150L runs a full 72-hour continuous high/low temperature and damp-heat cycle before crating. You approve the live test video, machine nameplate and 9-point calibration log before balance payment.
100% Complete English Wiring & Service Schematics
Every unit includes a USB drive and printed binder with full electrical schematics, refrigeration piping diagrams, controller SOP videos and custom voltage matching (220V/380V, 50/60Hz).
Questions Before Choosing a 150L Chamber
Can the DR-H201-150L test powered PCBs and active automotive modules?
Yes. Powered operation must be sized against your active heat dissipation (W), cable routing and target low temperature. Share your total watts and duty cycle along with the sample layout so DERUI engineers can verify the refrigeration margin and guarantee loaded pull-down rates.
Can I use it for a 1,000-hour 85°C/85% RH steady-state damp-heat test?
Yes. The DR-H201-150L is built with a full-TIG welded SUS304 stainless liner, isolated stainless boiler humidification and automatic water feed specifically for long-duration 85°C/85% RH runs (IEC 60068-2-78 / JESD22-A101). Include your required duration, water supply arrangement and powered heat in your enquiry.
Does −70°C capability mean humidity control at −70°C?
No. The −70°C rating describes the dual-stage cascade low-temperature limit for dry cold testing. Active humidity control (20%–98% RH) operates within the combined temperature–humidity envelope. Request our official T-RH envelope chart to verify your exact cycle stages.
How many specimens fit in one batch inside the 500 × 500 × 600 mm workspace?
Capacity depends on complete specimen dimensions, fixtures, spacing and airflow clearance (total loaded volume should not exceed 1/3 of the workspace, and air supply/return vents must remain unobstructed). Send your specimen drawing and quantity for a free layout check.
What determines the price and how are overseas warranty issues handled?
Price is primarily determined by the refrigeration tier (0°C, −20°C, −40°C or −70°C), custom voltage transformers and interface ports. Every overseas shipment includes a free 2-year consumable spare parts kit inside the crate, full English wiring schematics, a 72-hour pre-shipment burn-in video and 30-minute WhatsApp engineer video diagnostics.
Turn Your Test Requirement into a Verified 150L Configuration
Send your sample dimensions and quantity, target temperature–humidity profile, and any powered heat (watts). Add the destination country and required cable ports if available. If you have a test standard or fixture drawing, include it in the discussion.
Ask DERUI for a configuration proposal covering the selected temperature option, sample arrangement, 9-point factory test curve and quotation scope. You do not need a finished equipment specification to start the conversation.




















