150l Humidity Heat Test Chamber

Product overview

The DR-H201-150L supports programmed temperature and damp-heat testing for electronic assemblies, automotive components and materials. Its workspace suits fixture and batch layouts that need more room than a compact cabinet.

Item Specification
Model / nominal volume DR-H201-150L / 150 L
Chamber dimensions 500 × 500 × 600 mm; confirm dimension orientation on the drawing
Temperature options 0 / −20 / −40 / −70°C to +150°C
Humidity range 20% to 98% RH within the selected operating envelope
Heating / cooling 1–3°C/min / 0.7–1°C/min; conditions must be specified
Safe and reliable
well-made
Quality assurance
customization
MessageWhatsApp
Hotline number 15580327593
  • Product Details
  • Technical parameters
  • FAQ
  • Contact us

DERUI · INDUSTRIAL-GRADE RELIABILITY

150L Humidity Heat Test Chamber for Component Reliability Testing

Give electronic assemblies, sensors and automotive components room for a repeatable temperature and humidity test. The DR-H201-150L (also configured as a 150L programmable climatic test chamber or damp-heat environmental chamber) combines a 500 × 500 × 600 mm SUS304 workspace with industrial-grade refrigeration, helping your lab run 1,000-hour validation cycles without drift or unplanned stoppage.

✓ 150L Usable Volume
500×500×600 mm precision workspace
✓ 4 Temperature Tiers
Selectable down to −70°C (+150°C max)
✓ 2-Year Spare Parts
Zero-excuse overseas lab support

Start with your sample and target profile—not just the lowest temperature on a brochure. Share your assembly dimensions and active heat (watts) to receive a verified configuration and real factory test curve.

Room for the Assembly—and the Air Around It

The 500 × 500 × 600 mm internal chamber provides a nominal 150 L volume for components and fixtures that need more space than a compact cabinet. A useful layout accommodates the complete assembly, its support and test leads while leaving paths for conditioned air. Filling every available centimetre is not the same as creating a reliable test arrangement.

Electronics and sensors

Expose PCBs, connectors and control modules to specified temperature and moisture conditions. Include cable routing and any powered monitoring in the layout.

Automotive components

Evaluate assemblies, housings and material interfaces against a defined environmental procedure. Choose the profile around the component requirement, not an assumed universal automotive cycle.

Materials and laboratory work

Use controlled climatic exposure for conditioning and comparative studies. Keep specimen location and loading consistent when comparing batches or design changes.

Rear equipment compartment of a DERUI DR-H201-150L humidity heat test chamber showing refrigeration piping and compressor
Rear equipment compartment of the DR-H201-150L showing refrigeration piping, pressure protection switches and compressor layout.

A smaller load may suit the 80L temperature and humidity chamber. For a fixture that cannot fit with adequate circulation space, discuss a larger cabinet through our temperature test chamber range. Moving up in volume should solve a real loading problem, rather than simply add unused space.

Choose the Temperature Option Around Your Test

All four DR-H201-150L tiers share the same 500 × 500 × 600 mm workspace, ±0.5°C temperature fluctuation and 20%–98% RH humidity system. The price difference comes strictly from the refrigeration architecture required to reach your lowest setpoint under load:

Temperature option Cooling architecture Selection focus & typical test scope
0°C to +150°C Single-stage hermetic compressor Most economical tier for steady-state damp heat (IEC 60068-2-78, 40°C/93% RH, 85°C/85% RH) without sub-zero stages.
−20°C to +150°C High-efficiency single-stage system Entry laboratory standard for consumer electronics, packaging and basic cold storage combined with damp heat.
−40°C to +150°C Heavy-duty / binary refrigeration Most popular R&D tier for automotive modules (ISO 16750), cyclic damp heat (IEC 60068-2-30) and powered PCB assemblies.
−70°C to +150°C Dual-stage cascade refrigeration Deep-cold configuration for aerospace, defense (MIL-STD-810H), telecom 5G and cold-start validation requiring rapid pull-down.

The humidity range is 20% to 98% RH within the applicable temperature–humidity operating envelope. For a programme combining dry cold, heat and damp heat, identify which stages require humidity control so the configuration review covers the complete sequence.

Make the quotation comparable: send the same setpoints, transition requirements, sample heat (W) and cable port interfaces when evaluating configurations. Cabinet volume alone does not define refrigeration capacity or the final equipment scope.

Control the Exposure. Keep the Test Traceable.

The chamber brings temperature control, moisture regulation and forced-air circulation into a programmable system. Its value is not simply reaching a number on the display: it is giving your team a practical way to set up, run and document the intended exposure.

Programmable operation

Organise temperature and humidity exposure around the required stages. Define transitions, dwell periods and repeat cycles in the test programme so operators can follow a consistent sequence.

Forced-air circulation

A circulating air system distributes the conditioned environment through the workspace. Leave supply and return paths clear; a tightly packed fixture can change the conditions around individual specimens.

Computer connection and records

The published controller features include LAN computer connection and USB export functions. Discuss the required data fields, CSV/PDF export format and sensor arrangement when defining your recordkeeping needs.

Free live heat-load & airflow calculation

Powered PCBs and automotive modules emit heat that slows pull-down rates and destabilizes 85°C/85% RH runs.

Share your maximum heat dissipation in watts and operating duty cycle—DERUI engineers will calculate the exact refrigeration margin before you order.

Real empty-load curve & T-RH envelope chart

No chamber achieves 20%–98% RH at every extreme temperature.

Request our official combined Temperature–RH Operating Envelope Chart plus a 9-point mapping log exported from a recently built DR-H201-150L on our factory floor.

Why Our 150L Chamber Runs 1,000 Hours Straight Without Drift or Leaks

Low-cost chambers cut corners behind the sheet metal—using refurbished compressors, spot-welded liners that rust, and thin insulation that sweats on your lab floor. Here is what goes inside every DERUI DR-H201-150L to support long-duration validation:

❄️ Original French Tecumseh / German Bitzer Compressors

Paired with Danfoss solenoid valves and Saginomiya expansion valves to guarantee stable 0.7–1.0°C/min cooling rates even after years of thermal cycling.

Cheap alternatives: Unbranded domestic compressors that lose cooling capacity below −30°C after 6 months of heavy lab use.

🛡️ Full-TIG Welded SUS304 Stainless Inner Liner

100% seamless continuous welding backed by 100 mm high-density polyurethane foam insulation prevents moisture migration into the cabinet walls during 98% RH tests.

Cheap alternatives: Spot-welded seams sealed with silicone caulk that peel under +150°C heat and leak steam.

💧 Isolated Stainless Boiler Humidification + Auto Water Feed

External steam humidification with dry-burn protection and automatic water level control delivers +2% / −3% RH uniformity without spraying water droplets onto live PCBs.

Cheap alternatives: Open shallow water pans that scale up rapidly and contaminate test specimens.

🔒 12-Point Hardware Safety Interlocks

Independent hardware over-temperature limiter, compressor high/low pressure trips, phase-sequence protection and earth-leakage breaker protect high-value samples during unattended weekend runs.

Cheap alternatives: Software-only temperature limits that fail if the main SSR solid-state relay fuses closed.

DR-H201-150L Technical Specifications

Item Published specification
Model / nominal volume DR-H201-150L / 150 L
Internal chamber dimensions 500 (W) × 500 (D) × 600 (H) mm
Exterior / packing reference size 1050 × 970 × 1650 mm (confirm exact installation footprint and 600 mm service clearance on the approved GA drawing)
Temperature options 0 / −20 / −40 / −70°C low-temperature limit; +150°C upper limit
Temperature uniformity ≤2°C, no-load
Temperature fluctuation ±0.5°C, no-load
Humidity range 20%–98% RH within the applicable combined operating envelope
Humidity uniformity +2% / −3% RH
Humidity fluctuation ±2% RH
Heating rate 1.0–3.0°C/min (average, no-load)
Cooling rate 0.7–1.0°C/min (average, no-load)
Time setting range 1–60,000 min
Cable access Left-side test hole (standard Ø50 mm / Ø100 mm with silicone plug) for external power or signal cables
Observation window options 210 × 275 mm or 395 × 395 mm effective viewing area with anti-sweat heater
Power supply matching Standard 220V/50Hz or 380V/50Hz; custom 110V/220V/480V 60Hz configurations available for global laboratory grids

Heating and cooling rates depend on the selected configuration, temperature interval, ambient conditions and load. Use a project-specific acceptance profile to establish the performance required for your application.

Map the Chamber to the Test Procedure & Field Cases

Use the standard and product specification to define the profile. The chamber supports environmental exposure only when its selected configuration covers every required setpoint, transition and tolerance.

Reference Typical use Confirm before testing
IEC 60068-2-30 Cyclic damp heat Edition, cycle, transitions, condensation and recovery
IEC 60068-2-78 Steady-state damp heat Temperature, RH, duration, stabilization and evaluation
MIL-STD-810H Method 507.6 Tailored humidity exposure Procedure, climatic cycle, specimen operation and acceptance criteria
JESD22-A101 / A100 Electronic-device moisture testing Applicable method, bias interfaces, safety and monitoring

Define the exposure

Include temperature, RH, transitions, dwell periods and specimen operating state in the test request.

Define the measurement

Distinguish chamber-air temperature from specimen temperature, and specify when exposure timing starts.

How Engineering Teams Worldwide Configure the DR-H201-150L

🇩🇪 Germany · Automotive Electronics

IEC 60068-2-30 Cyclic Damp-Heat: Configured a −40°C to +150°C unit with dual Ø100 mm silicone-sealed cable ports for 24 powered CAN-bus sensor modules (120 W active heat). Programmed pre-heating eliminated ramp-up condensation short circuits and passed OEM audit on the first run.

🇲🇽 Mexico · PCB & Connector Assembly

1,000-Hour 85°C/85% RH Steady-State: Upgraded from overcrowded 80 L units to a −20°C to +150°C 150 L chamber with direct RO water feed holding 60 harness connectors. Improved workspace airflow uniformity from ±3.1°C down to ±0.6°C with zero manual refills over 42 days.

🇻🇳 Vietnam · Telecom & 5G Hardware

MIL-STD-810H Thermal Cycling: Deployed a −70°C to +150°C cascade system with reinforced 50 kg shelves for 18 kg die-cast aluminum RF router housings. Achieved repeatable 1.0°C/min pull-down to −55°C despite high thermal mass, saving $4,200/month in external lab fees.

Choose 150L Only When the Load Fits

80L chamber

Better suited to smaller loads when footprint and lower conditioned volume are priorities.

150L chamber

Provides a 500 × 500 × 600 mm workspace for medium-sized component and fixture layouts while maintaining at least 1/3 unobstructed airflow clearance.

408L or larger

Review a larger cabinet when the complete loaded envelope or required airflow clearance cannot fit the 150 L workspace.

Define Supply, Acceptance & Zero-Excuse Overseas Support

A useful equipment proposal connects the cabinet to your laboratory. Before ordering, bring the configuration, utilities, documentation and acceptance requirements into one supply scope so purchasing and engineering can verify every detail.

Project decision What to include in the discussion
Equipment and interfaces Temperature option, specimen supports, cable access, monitoring and data requirements; distinguish included items from options.
Laboratory preparation Destination power supply, room conditions, heat rejection, RO/distilled water quality, drainage, access route and service space.
Acceptance records (FAT) Setpoints, 9-point sensor locations, empty or loaded condition, stabilization, measurement duration and pass/fail limits.
Handover and support Required operating instructions, electrical drawings, training, warranty coverage, spare-parts kit and support contact arrangements.

Zero-Excuse Overseas Support: Written in Numbers, Not Vague Promises

We know your biggest concern when importing testing equipment is downtime during a critical customer audit. Here is exactly how DERUI protects your laboratory across time zones:

2-Year Free Consumable & Spare Parts Kit Included

Shipped inside your crate at zero extra cost: extra SSR solid-state relays, wet-bulb wicks, silicone port plugs, fuse set and water float switch so your local technician can fix 90% of routine wear items in 15 minutes.

30-Min Direct Engineer Video Diagnostics

No chatbots. Message our WhatsApp hotline (+86 135 2795 8363) with any alarm code and get a live video walk-through with a senior refrigeration and PLC engineer within 30 minutes on workdays.

72-Hour Pre-Shipment Continuous Burn-In Video

Your DR-H201-150L runs a full 72-hour continuous high/low temperature and damp-heat cycle before crating. You approve the live test video, machine nameplate and 9-point calibration log before balance payment.

100% Complete English Wiring & Service Schematics

Every unit includes a USB drive and printed binder with full electrical schematics, refrigeration piping diagrams, controller SOP videos and custom voltage matching (220V/380V, 50/60Hz).

Questions Before Choosing a 150L Chamber

Can the DR-H201-150L test powered PCBs and active automotive modules?

Yes. Powered operation must be sized against your active heat dissipation (W), cable routing and target low temperature. Share your total watts and duty cycle along with the sample layout so DERUI engineers can verify the refrigeration margin and guarantee loaded pull-down rates.

Can I use it for a 1,000-hour 85°C/85% RH steady-state damp-heat test?

Yes. The DR-H201-150L is built with a full-TIG welded SUS304 stainless liner, isolated stainless boiler humidification and automatic water feed specifically for long-duration 85°C/85% RH runs (IEC 60068-2-78 / JESD22-A101). Include your required duration, water supply arrangement and powered heat in your enquiry.

Does −70°C capability mean humidity control at −70°C?

No. The −70°C rating describes the dual-stage cascade low-temperature limit for dry cold testing. Active humidity control (20%–98% RH) operates within the combined temperature–humidity envelope. Request our official T-RH envelope chart to verify your exact cycle stages.

How many specimens fit in one batch inside the 500 × 500 × 600 mm workspace?

Capacity depends on complete specimen dimensions, fixtures, spacing and airflow clearance (total loaded volume should not exceed 1/3 of the workspace, and air supply/return vents must remain unobstructed). Send your specimen drawing and quantity for a free layout check.

What determines the price and how are overseas warranty issues handled?

Price is primarily determined by the refrigeration tier (0°C, −20°C, −40°C or −70°C), custom voltage transformers and interface ports. Every overseas shipment includes a free 2-year consumable spare parts kit inside the crate, full English wiring schematics, a 72-hour pre-shipment burn-in video and 30-minute WhatsApp engineer video diagnostics.

Turn Your Test Requirement into a Verified 150L Configuration

Send your sample dimensions and quantity, target temperature–humidity profile, and any powered heat (watts). Add the destination country and required cable ports if available. If you have a test standard or fixture drawing, include it in the discussion.

Ask DERUI for a configuration proposal covering the selected temperature option, sample arrangement, 9-point factory test curve and quotation scope. You do not need a finished equipment specification to start the conversation.

FacebookLinkedInXRedditWhatsApp

Technical parameters

capacity

chamber size(mm)

Carton size(mm)

 

50L

350*350*400

580*870*1300

80L

400*400*500

910*1030*1520

100L

400*500*500

1050*870*1550

150L

500*500*600

1050*970*1650

225L

600*500*750

1150*970*1900

408L

800*600*850

1350*1150*1850

800L

1000*800*1000

1500*1540*1850

1000L

1000*1000*1000

1550*1600*1860

index Temperature range 0℃~150℃           -20℃~150℃        -40℃~150℃            -70℃~150℃ 
Temperature uniformity ≤2℃(No-load time)
Temperature fluctuation ±0.5℃(No-load time)
Humidity range 20%~98% RH
Humidity uniformity +2% -3% RH
Humidity fluctuation ±2%
Heating rate 1.0~3.0℃/min
Cooling rate 0.7~1.0℃/min
Time setting range 1~60000M
Test hole It is installed on the left side of the machine for external test power cord or signal cable
Observation window 210×275mmOR395×395mm(Effective horizon)

Questions before ordering

What are the 150L internal dimensions?

The table lists 500 × 500 × 600 mm. Confirm the width, depth and height order on the approved drawing before checking specimen fit.

Does 20% to 98% RH apply at every temperature?

No rectangular envelope should be assumed. Request the combined temperature-RH operating chart for the selected configuration.

How much powered heat can the standard chamber handle?

The technical schedule does not state a confirmed watt limit. Provide maximum specimen heat so DERUI can size the refrigeration system and state loaded performance.

Will it run on 220V single-phase power?

The current visible table does not confirm supply for this specific configuration. Voltage, phase, current and rated power must be included in the quotation.

What water system is standard?

The selected configuration should establish a confirmed tank volume or direct-feed arrangement. Confirm water quality, storage/feed method and drainage in the bill of materials.

What should be sent for a quotation?

Send the standard, specimen drawing and mass, powered heat, full climatic profile, interfaces, utilities and FAT requirements.

How should we compare quotations for this configuration?

A 150 L purchase makes sense when the complete fixture needs the additional workspace. Compare drawings with the fixture installed, including test leads, sample height and clear paths to the air supply and return. Treat the 1050 × 970 × 1650 mm carton-size field as a packing-related entry until its meaning is confirmed; it should not silently become an installed machine-clearance dimension.

What evidence should be reviewed before approving the order?

Request the selected low-temperature option, the temperature–RH operating chart, a load arrangement and the supply specification together. Confirm humidification water, drainage and service clearance before ordering. The factory acceptance record should link the measured temperature/RH points to the same configuration and load assumptions quoted to the buyer.