Floor 1, No. 3, Shugang Avenue, Hongmei Town, Dongguan City, Guangdong Province, China

20 years environmental test chamber manufacturer3000+ customer deliverables worldwide           Email: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363
UV test chamberUV test chamber

UV Test Chamber Manufacturer & Weathering Solutions

Accelerated UV light aging and weathering test chambers compliant with ASTM G154 and ISO 4892-3 for material durability evaluation.

UV Accelerated Weathering Tester DR-H302

UV Accelerated Weathering Tester DR-H302

Fabric Uv aging Test Chamber​

Fabric Uv aging Test Chamber​

Uv Weather Test Chamber

Uv Weather Test Chamber

UV Accelerated Aging Chamber

UV Accelerated Aging Chamber

DR-H303 Anti-Yellowing Aging Test Chamber

DR-H303 Anti-Yellowing Aging Test Chamber

Desktop Yellowing Resistance Test Chamber

Desktop Yellowing Resistance Test Chamber

Specify Fluorescent UV Testing by Lamp and Moisture Cycle

Choose UV weathering equipment from the governing method, fluorescent lamp type, irradiance control, exposure temperature, condensation or spray sequence, specimen format and evaluation objective.

ASTM G154, ISO 4892-3 or Defined Cycle

Identify the exact procedure and cycle. Lamp type, irradiance, UV exposure temperature, condensation or spray stage, duration and specimen mounting should be taken from the applicable method.

Review UV Weathering Methods →

UVA-340 or UVB-313 Lamp Selection

UVA-340 and UVB-313 are not interchangeable. Select the lamp from the standard, material and acceleration objective, while recognizing that different spectral output can produce different degradation mechanisms.

Compare UV Lamp Options →

Irradiance and Temperature Control

Specify irradiance setpoint and control method together with panel or chamber temperature. Confirm sensor calibration, lamp ageing compensation and uniformity across the exposed specimen area.

Evaluate UV Control Performance →

Condensation and Water-Spray Stages

Define whether moisture exposure uses heated condensation, water spray or both. Water quality, temperature, timing, transition and drainage affect repeatability and the failure mechanism produced.

Configure UV and Moisture Cycles →

Specimen Holders and Evaluation Objective

Provide specimen dimensions, thickness, quantity, backing, holders and the change being evaluated, such as colour, gloss, cracking or strength. Mounting must expose samples consistently without unintended water retention.

Plan Material-Specific UV Testing →

When Xenon Testing Is More Appropriate

Fluorescent UV focuses on the ultraviolet region; xenon systems provide broader simulated sunlight with method-specific filters. Compare the product’s service environment and standard before selecting the technology.

Compare UV and Xenon Methods →

Need Help Choosing a UV Lamp and Exposure Cycle?

Send the material, applicable method, lamp requirement, irradiance, temperature, moisture cycle, specimen dimensions and evaluation criteria.

Request a UV Weathering Recommendation Download UV Chamber Catalogs

Light-exposure equipment selection

Select the UV Test by Exposure and Evaluation Goal

Fluorescent UV weathering, material-specific exposure and yellowing checks are related purchasing questions—not one interchangeable test. Start with the referenced method, lamp type, wet/dry cycle and property to measure. Then compare the six equipment pages below against the specimen and required records.

Evaluation goal Relevant equipment pages Confirm before quotation
Fluorescent UV weathering across common materials DR-H302 UV Accelerated Weathering Tester
UV Accelerated Aging Chamber
The cited test method and edition, lamp specification, irradiance control where required, temperature and water/condensation cycle. Compare the quoted configuration, not just the product title.
Fabric or textile-specific specimens Fabric UV Aging Test Chamber Specimen holder, exposed area, reference material, color or strength measurement and the textile-specific procedure. Do not substitute a general plastics cycle without review.
A defined UV/weather exposure sequence UV Weather Test Chamber UV and wet phases, cycle timing, chamber/black-panel temperature, specimen rotation if needed and recording points. Confirm which functions are actually present on the selected unit.
Yellowing or color-change evaluation Anti-Yellowing Aging Chamber
Desktop Yellowing Resistance Chamber
Required light source and spectrum, specimen form, exposure temperature/time and color-change metric. These pages must not be assumed to match an ASTM G154 fluorescent-UV weathering cycle.
Use the method to set the boundary. ASTM G154 and ISO 4892-3 address fluorescent UV exposure; they do not make every yellowing tester a weathering chamber. If the requirement calls for xenon-arc exposure, review the xenon chamber range instead. Accelerated exposure does not by itself predict a fixed outdoor service life.

What to Send for a UV or Yellowing-Test Recommendation

A defined exposure and evaluation endpoint is more useful than a requested number of “equivalent outdoor years.”

Method
Standard and edition, exact cycle and customer acceptance criteria
Light source
Lamp type, spectrum, irradiance setpoint and control requirement
Specimens
Material, size, thickness, count, mounting and exposed area
Moisture & heat
Condensation, spray, dark periods and temperature control points
Evaluation
Color or gloss change, cracking, strength retention and measurement method
Installation
Power, water, exhaust, lab space and documentation needs

Need to compare methods first? Read the UV weathering test guide. Ready to specify equipment? Send your exposure requirement to DERUI →

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MessageMessage

Request a Quote