Chambre d'essai à humidité et chaleur de 150L

Le DERUI DR-H201-150L humidity heat test chamber provides a 500 × 500 × 600 mm workspace for programmed temperature and damp-heat exposure. Select the refrigeration option and humidity envelope from the complete specimen load, profile and FAT requirements.

Model / Capacity DR-H201-150L / 150 L
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 500 × 500 × 600 mm; confirm W × D × H order
Temperature Options 0 / -20 / -40 / -70°C to +150°C
Plage d'Humidité 20% to 98% RH; confirm combined temperature-RH envelope
Before Quotation Confirm specimen load, powered heat, profile, supply, water system, interfaces and FAT
Sûr et fiable
bien fabriqué
Assurance qualité
personnalisation
MessageWhatsApp
Numéro de hotline 15580327593
  • Détails du produit
  • Paramètres techniques
  • Contactez-nous
150L Programmable Damp-Heat Testing

DR-H201-150L Humidity Heat Test Chamber

Apply programmed temperature, steady damp heat and cyclic humidity profiles to electronic modules, automotive components, materials and assemblies in a 150 L workspace. Select the temperature option and refrigeration capacity from the complete specimen load, powered heat and required climatic profile.

Engineering basis: nominal chamber volume does not confirm usable space or loaded performance. Include fixtures, airflow clearance, cable routing, specimen heat and FAT criteria in the technical agreement.
Model / capacityDR-H201-150L / 150 L
Published workspace500 × 500 × 600 mm
Temperature options0 / -20 / -40 / -70°C to +150°C
Plage d'humidité20% à 98% HR

Where the 150L Chamber Fits

The 150 L configuration offers more fixture and specimen capacity than a compact 80 L unit while remaining a floor-standing laboratory chamber. It is suited to medium-sized component loads when the occupied workspace still permits conditioned air to circulate.

Electronic assemblies

Condition PCBs, connectors, control modules and sensor assemblies under defined temperature and moisture profiles.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Evaluate housings, electronics, seals and material interfaces using the applicable customer or industry procedure.

Materials and research

Run controlled conditioning, damp-heat exposure and comparative ageing studies with documented specimen placement.

Published DR-H201-150L Configuration

Article Published value Procurement note
Internal chamber size 500 × 500 × 600 mm Confirm the dimension order as W × D × H on the approved drawing
External/carton-size field 1050 × 970 × 1650 mm Confirm whether this is machine size, packing size or installation envelope
Temperature range options 0°C, -20°C, -40°C or -70°C low end; +150°C high end Select one refrigeration configuration
Uniformité de température ≤ 2°C, no-load Confirm mapping method and working-space definition
Fluctuation de température ±0.5°C, no-load Confirm stabilized condition and sensor point
Plage d'humidité 20% à 98% HR Request the valid combined temperature-RH operating envelope
Uniformité de l'humidité +2% / -3% RH Confirm test condition and measurement method
Fluctuation d'humidité ±2% RH Confirm setpoint and stabilized condition
Vitesse de chauffage 1.0 to 3.0°C/min Confirm average/linear definition, range and load
Vitesse de refroidissement 0.7 to 1.0°C/min Confirm selected low-temperature option, ambient and load
Time setting 1 to 60,000 min Confirm programme and cycle capacity

How the Climatic Control System Works

Control air temperature

Heating and refrigeration establish the programmed chamber-air temperature and transition rate.

Regulate moisture

Humidification and dehumidification control relative humidity within the valid combined operating envelope.

Distribute and record

Forced circulation and calibrated sensors determine how the condition is distributed and documented through the usable workspace.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits operating heat can slow cooling and reduce relative humidity. State maximum watts and duty cycle before refrigeration sizing.

150L DERUI Chamber Reference Image

DERUI DR-H201-150L humidity heat test chamber

Current DERUI image for the 150 L humidity heat chamber. Final controller, ports, shelving and utility connections follow the approved configuration.

Loading and Operating Discipline

Maintain airflow clearance

Confirm fixture and specimen placement without blocking supply or return air. Nominal volume is not the same as usable loaded space.

Seal cable entries

Close unused cable-port area to limit ambient air and moisture leakage that can disturb control or encourage frosting.

Confirm water requirements

Follow the approved manual for water quality, tank or direct-feed arrangement, drainage and routine humidifier maintenance.

Define dwell start

State whether exposure time begins at controller setpoint or after specimen sensors reach stabilization.

Record the loaded state

Document mass, location, fixture, powered operation and interfaces so later cycles can reproduce the same condition.

Manage condensation

Select a procedure-appropriate ramp and post-test handling sequence when surface moisture could influence results.

Map the Chamber to the Test Procedure

Use the standard and product specification to define the profile. The chamber supports environmental exposure only when its selected configuration covers every required setpoint, transition and tolerance.

Reference Utilisation typique Confirm before testing
IEC 60068-2-30 Cyclic damp heat Edition, cycle, transitions, condensation and recovery
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Steady-state damp heat Temperature, RH, duration, stabilization and evaluation
MIL-STD-810H Method 507.6 Tailored humidity exposure Procedure, climatic cycle, specimen operation and acceptance criteria
JESD22-A101 / A100 Electronic-device moisture testing Applicable method, bias interfaces, safety and monitoring

Choose 150L Only When the Load Fits

80L chamber

Better suited to smaller loads when footprint and lower conditioned volume are priorities.

150L chamber

Provides a published 500 × 500 × 600 mm workspace for medium-sized component and fixture layouts.

408L or larger

Review a larger cabinet when the complete loaded envelope or required airflow clearance cannot fit the 150 L workspace.

RFQ and FAT Checklist

Topic Information to provide or verify
Specimen Dimensions, mass, quantity, fixtures, material and powered heat
Profile Temperature-RH points, transitions, dwell, cycles and tolerances
Interfaces Ports, power, signals, thermocouples, network and data records
Utilités Voltage, current, phase, cooling method, water quality, drainage and ambient limits
FAT Sensor map, empty/loaded condition, stabilization, deviation, uniformity, alarms and report format
Documents Approved drawing, bill of materials, manuals, electrical diagram and agreed calibration scope

Foire Aux Questions

What are the published 150L internal dimensions?

The current table lists 500 × 500 × 600 mm. Confirm the width, depth and height order on the approved drawing before checking specimen fit.

Does 20% to 98% RH apply at every temperature?

No rectangular envelope should be assumed. Request the combined temperature-RH operating chart for the selected configuration.

How much powered heat can the standard chamber handle?

The visible technical table does not publish a confirmed watt limit. Provide maximum specimen heat so DERUI can size the refrigeration system and state loaded performance.

Will it run on 220V single-phase power?

The current visible table does not confirm supply for this specific configuration. Voltage, phase, current and rated power must be included in the quotation.

What water system is standard?

The visible page does not establish a confirmed tank volume or direct-feed arrangement. Confirm water quality, storage/feed method and drainage in the bill of materials.

What should be sent for a quotation?

Send the standard, specimen drawing and mass, powered heat, full climatic profile, interfaces, utilities and FAT requirements.

Configure the 150L Chamber from the Loaded Test

Send the complete profile and specimen information. DERUI can confirm the low-temperature option, humidity envelope, refrigeration capacity, interfaces, utilities and acceptance plan before quotation.

Request a 150L Chamber Review

FacebookLinkedInXRedditWhatsApp

Capacité

Taille de la chambre (mm)

Taille du carton (mm)

 

50L

350*350*400

580*870*1300

80L

400*400*500

910*1030*1520

100L

400*500*500

1050*870*1550

150L

500*500*600

1050*970*1650

225L

600*500*750

1150*970*1900

408L

800*600*850

1350*1150*1850

800L

1000*800*1000

1500*1540*1850

1000L

1000*1000*1000

1550*1600*1860

index Plage de température 0℃~150℃ -20℃~150℃ -40℃~150℃ -70℃~150℃ 
Uniformité de température ≤2℃ (temps sans charge)
Fluctuation de température ±0,5℃ (temps sans charge)
Plage d'humidité 20%~98% HR
Uniformité de l'humidité +2% -3% HR
Fluctuation d'humidité ±2%
Vitesse de chauffage 1,0~3,0℃/min
Vitesse de refroidissement 0,7~1,0℃/min
Plage de réglage du temps 1~60000M
Trou de test Il est installé sur le côté gauche de la machine pour le cordon d'alimentation externe ou le câble de signal
Fenêtre d'observation 210×275mmOU395×395mm (Horizon efficace)