Máy Thử Nhiệt Cháy Tế Bào Pin Xe Điện

The DERUI DR-D211 EV battery cell fire tester applies a defined gas-flame exposure to a secured cell or small battery article. Specify the burner setup, measurement plan and dedicated fire-test room before ordering; this open-structure apparatus is not a sealed chamber or full-pack test bench.

Mẫu DR-D211
Phương pháp thử External gas-flame exposure for R&D; exact procedure to confirm
Maximum Specimen 400 × 400 × 200 mm; ≤20 kg stated
Flame Height Published 100–150 mm; burner and measurement basis to confirm
Burning Time 1–60,000 s setting
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Open front/rear; dedicated fire room, exhaust and remote safety review required
An toàn và đáng tin cậy
Chế tạo tốt
Đảm bảo chất lượng
Tùy chỉnh
Tin nhắnWhatsApp
Số điện thoại đường dây nóng 15580327593
  • Chi tiết sản phẩm
  • Thông số kỹ thuật
  • Câu hỏi thường gặp
  • Liên hệ với chúng tôi
DR-D211 · External Flame Exposure

EV Battery Cell Fire Tester for Controlled Flame Exposure

Expose a secured cell or small battery specimen to a defined gas flame and document how its casing, vent, nearby materials and fragments respond. DR-D211 is an open-front-and-rear fire-test apparatus, intended for a dedicated laboratory installation—not a sealed chamber or a full-pack fire-resistance bench.

Before selecting equipment: define the specimen's stored energy, the exact exposure method, burner geometry, measurement channels and site fire-safety plan. A published flame setting alone does not establish a certified test result.
MẫuDR-D211
Maximum stated specimen400 × 400 × 200 mm; ≤20 kg
Published flame height100–150 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits1–60,000 seconds

Use the Tester for the Right Question

Cell design screening

Compare casing, vent and shield behavior under a repeatable external-flame setup. Record specimen identity and condition for every run.

Small-assembly observation

Study ignition, burning and fragment behavior of a secured article that fits the published size and mass limits, subject to a facility hazard review.

Instrumented R&D

Add temperature, voltage, video or gas measurements only when the selected instrumentation and sampling plan are included in the approved configuration.

Not interchangeable: this external-flame device does not replace a battery crush tester, impact tester, calorimeter or thermal-runaway propagation laboratory.
DERUI EV battery cell fire tester product view
Existing product-gallery image. Confirm final delivered configuration against the approved drawing.

Published DR-D211 Configuration

These are the current page's published values. Terms such as “temperature accuracy” need a defined sensor position, operating condition and calibration method before they can become contractual acceptance criteria.

Mục Published value Confirm before ordering
Model and specimen scope DR-D211; EV steel-shell battery stated Other cell formats, enclosure types and acceptable stored-energy limit.
Maximum article 400 × 400 × 200 mm; ≤20 kg Fixture space, clearance to burner and safe support load.
Chiều cao ngọn lửa 100–150 mm Measurement method, fuel, pressure, burner geometry and distance to specimen.
Thời gian cháy 1–60,000 s setting Timer start/stop points, flame-out handling and event log.
Temperature bands A: 300–600°C; B: 600–900°C; C: 900–1200°C; stated ±20°C Whether these describe burner settings, sensor ranges or measured specimen exposure; sensor and calibration location.
Ignition and air Automatic high-voltage pulse ignition stated; automatic air supply and airflow control Fuel type, supply pressure, ignition confirmation, flame supervision and shutoff logic.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Open front and rear; high-temperature-resistant insulation stated Dedicated room, extraction hood, exclusion zone and combustible clearances.
Alarm and protection Three-color status lamp, abnormal-operation alarm and limit protection stated Actual sensors, interlocks, emergency fuel isolation and alarm outputs.
Equipment dimensions Main unit 900 × 1140 × 1200 mm; console 600 × 400 × 1200 mm Final W × D × H drawing, service/access clearance and room layout.
Electrical supply AC220 V Frequency, power/current, breaker, grounding and destination voltage.

Define a Repeatable Flame-Exposure Protocol

Identify the specimen

Record cell or assembly format, dimensions, mass, chemistry, capacity, state of charge and prior conditioning.

Choose the governing method

State the exact standard edition or internal procedure, specimen level and result criteria.

Specify the burner

Approve fuel, burner geometry, gas pressure, flame height, distance, airflow and pre-test verification.

Specify exposure timing

Define ignition, stabilization, start, dwell, termination and post-flame observation points.

Specify measurements

Select thermocouple locations, voltage channels, video, gas and other measurements with timestamps.

Agree on safety response

Review remote operation, fuel shutoff, extraction, emergency response, cooldown and specimen quarantine.

Standards: Method Match, Not a Blanket Claim

Reference What the buyer may need DR-D211 boundary
UL 9540A Thermal-runaway fire-propagation evaluation at defined specimen levels. The gas-flame apparatus is not a complete UL 9540A test system. A qualified laboratory must determine whether a specific R&D activity fits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits External-fire resistance procedure for a REESS/vehicle or representative subsystem. Its fuel-pan exposure, size and mounting are not automatically reproduced by this small gas-burner device.
Customer/OEM method Specified external-flame exposure of a cell or small article. Potential fit only after matching fixture, burner, measurements, hazard controls and acceptance criteria.

Do not list ASTM E3189 as a battery fire-test method; it addresses preparation of fire-debris samples for ignitable-liquid residue analysis.

Open Construction Makes the Test Room Part of the System

Because the published design is open at the front and rear, the equipment cannot be described as a sealed fire-containment chamber. Flame, smoke, hot gases, ejecta and electrolyte products may enter the surrounding space. Installation requires approval by the laboratory's fire and EHS specialists.

Gas and ignition

Specify fuel type, pressure regulation, leak detection, flame supervision and an accessible emergency shutoff.

Ventilation and separation

Engineer combustion exhaust and makeup air, restrict access during operation, and keep the console and personnel outside the hazard zone.

Post-event control

Define fire response, cooling, monitoring for re-ignition, quarantine and disposal for the actual cell chemistry and energy.

Configuration boundary: gas analysis, calorimetry, automatic suppression and detailed time-synchronized reports are not established as standard by the published DR-D211 parameter table. Quote them explicitly if required.

Recommended Factory and Site Acceptance Checks

Kiểm tra Evidence to agree before shipment
Burner setup Fuel/pressure specification, measured flame height, fixture position and repeatability.
Temperature claim Sensor type, location, calibration and meaning of the A/B/C bands and ±20°C figure.
Timing and ignition Witnessed ignition sequence, timer behavior, flame-loss response and safe shutdown.
Specimen fixture Approved drawing for the 400 × 400 × 200 mm / ≤20 kg limit and required exposure surface.
Safety interfaces Emergency fuel isolation, alarm contacts, ventilation interlock and remote operation as contracted.
Tài liệu Operating manual, gas/electrical drawings, calibration scope and FAT report.

Câu hỏi thường gặp

What does the DR-D211 actually test?

It exposes a secured cell or small battery article to a controlled gas flame for a defined period so visible behavior and any specified instrument channels can be recorded.

Is this a sealed explosion-proof chamber?

No. The published design is open at the front and rear. The dedicated fire-test room, remote operation and engineered ventilation are part of the safety design.

Does DR-D211 alone meet UL 9540A?

No. UL 9540A addresses a broader thermal-runaway propagation test program. A qualified lab must assess any proposed use of this device within a specific research setup.

Can it perform UNECE R100 pack-level fire exposure?

Not from the published size and gas-burner arrangement. The R100 procedure has different specimen and fuel-pan requirements.

What do the 300–1200°C temperature bands mean?

The source does not define the measurement point clearly. Ask DERUI whether these are burner settings, sensor ranges or actual specimen exposure, and request calibration evidence.

Are gas analysis, fire suppression and automatic reports included?

They are not confirmed in the published technical table. Include each required sensor, control and output in the technical agreement.

Which specimens fit?

The published envelope is 400 × 400 × 200 mm and no more than 20 kg. Actual usable space and allowed stored energy also depend on the fixture and room safety review.

What should accompany an RFQ?

Send specimen data, chemistry, energy and state of charge, exact method, burner/fuel exposure, instrumentation, room layout, extraction, emergency strategy and acceptance criteria.

Review the Flame Test and Facility Together

Send the specimen drawing, stored energy, exposure method and room safety concept. DERUI can confirm whether DR-D211 fits your R&D task and document the required options and FAT checks.

Request a DR-D211 technical review

Send with your inquiry

  • Specimen size, mass, chemistry and SOC
  • Method, fuel and exposure profile
  • Measurement and reporting needs
  • Exhaust, gas and fire-safety plan
FacebookLinkedInXRedditWhatsApp
Mẫu DR-D211
Phạm vi nhiệt độ Khoảng A 300-600℃
Khoảng B 600-900℃
Khoảng C 900-1200℃
Độ chính xác ±20℃
Kích thước ngoài (Rộng*Sâu*Cao) 900*1140*1200mm
Kích thước bảng điều khiển (W*D*C) 600*400*1200mm
Thông số pin phù hợp Vỏ thép EV
Phạm vi sản phẩm tương thích (W*D*H) 400*400*200mm
Trọng lượng pin ≤20KG
Thời gian cháy 1s-60000s
Chiều cao ngọn lửa 100-150mm
Cấu trúc thiết bị Mở trước và sau
Bật lửa Cháy tự động bằng tia lửa cao áp
Phương pháp cung cấp khí Cung cấp khí tự động để đáp ứng các mức oxy khác nhau
Chất liệu cách nhiệt Bông đá chống cháy chịu nhiệt cao
Tốc độ gió Điều khiển tự động
Chức năng báo động Đèn ba màu gập lại, báo động hoạt động bất thường
Chức năng bảo vệ Chống quá tải, chức năng chống sai sót, bảo vệ an toàn
Vật liệu thiết bị Hợp kim nhôm + tấm thép cán nguội, sơn phủ, màu tiêu chuẩn xám ấm 1C (màu có thể tùy chỉnh)
Khí đốt cháy khí
Nền chịu lực Yêu cầu mặt đất vững chắc, chịu lực 1T/m3
Nguồn điện AC220V

1. Hỏi: Máy thử cháy pin xe điện là gì?
A: Máy thử cháy pin xe điện là thiết bị phòng thí nghiệm chuyên dụng được thiết kế để đốt cháy có kiểm soát các tế bào pin lithium-ion nhằm nghiên cứu cách pin phản ứng trong quá trình quá nhiệt, cách ngọn lửa lan truyền, và kiểm tra khả năng chống cháy của chúng, điều này rất quan trọng để đảm bảo an toàn cho xe điện.

2. Hỏi: Chi phí của buồng thử cháy pin là bao nhiêu?
A: Chi phí của buồng thử cháy pin có thể dao động lớn tùy thuộc vào kích thước, khả năng và các tùy chỉnh. Đối với mẫu đáng tin cậy như Máy thử cháy pin xe điện Derui, tốt nhất là liên hệ trực tiếp với nhà sản xuất để có báo giá chính xác. Họ thường cung cấp giá theo cấp độ và giảm giá cho các đơn hàng số lượng lớn, điều này giúp giảm chi phí cho các phòng thí nghiệm cần nhiều thiết bị.

3. Hỏi: Những tính năng an toàn nào tôi nên tìm trong thiết bị thử cháy pin?
A: An toàn là trên hết. Bạn chắc chắn nên tìm kiếm các tính năng như hệ thống dập cháy tự động, giám sát khí và nhiệt độ theo thời gian thực, và một công tắc tắt khẩn cấp. Ví dụ, máy thử của Derui bao gồm tất cả các tính năng này, cộng với các khóa an toàn trên hệ thống đánh lửa, là một tính năng quan trọng để ngăn chặn hoạt động vô tình.

4. Hỏi: Máy thử cháy của Derui có tuân thủ tiêu chuẩn UL 9540A không?
A: Vâng, hoàn toàn chính xác. Máy thử nghiệm cháy pin xe điện Derui EV Battery Cell Fire Tester được thiết kế đặc biệt để hỗ trợ kiểm tra theo UL 9540A, cùng với các tiêu chuẩn chính khác như ASTM E3189 và GB/T 31485. Điều này làm cho nó trở thành một lựa chọn vững chắc cho bất kỳ ai cần chứng nhận cho các tế bào pin hoặc hệ thống pin của mình để phù hợp với thị trường.

5. H: Tôi có thể thử nghiệm các loại tế bào pin khác nhau với một máy không?
A: Câu hỏi hay! Nhiều máy thử có buồng cố định, nhưng mẫu Derui sử dụng thiết kế buồng dạng mô-đun. Điều này có nghĩa là bạn có thể điều chỉnh hoặc cấu hình lại hệ thống để phù hợp với các kích thước và định dạng tế bào pin khác nhau, từ các tế bào hình trụ nhỏ đến các túi lớn hơn, mang lại sự linh hoạt tuyệt vời cho phòng R&D.

6. H: Loại dữ liệu nào máy thử cháy pin của Derui thu thập?
A: Nó thu thập dữ liệu toàn diện, độ phân giải cao, rất quan trọng cho phân tích. Bạn nhận được các hồ sơ nhiệt độ chính xác từ nhiều điểm, thay đổi áp suất bên trong buồng, và với các phụ kiện tùy chọn, bạn thậm chí có thể phân tích khí thải sinh ra trong quá trình cháy. Dữ liệu này rất cần thiết để hiểu các chế độ hỏng hóc.

7. H: Hệ thống này có khó vận hành đối với kỹ thuật viên mới không?
A: Từ thông số kỹ thuật của sản phẩm, có vẻ như họ đã ưu tiên tính thân thiện với người dùng. Nó đi kèm với giao diện màn hình cảm ứng trực quan và hướng dẫn cài đặt rõ ràng. Mặc dù luôn cần đào tạo phù hợp cho thiết bị chuyên dụng như vậy, nhưng đường cong học tập có thể quản lý được, cho phép kỹ thuật viên mới làm quen khá nhanh.

8. H: Ai thường sử dụng loại thiết bị mô phỏng cháy pin xe điện này?
A: Những người dùng chính là Nhà sản xuất pin xe điện, phòng thử nghiệm bên thứ ba, và cơ sở nghiên cứu. Họ sử dụng nó cho mọi thứ từ nghiên cứu và phát triển giai đoạn đầu đến kiểm tra chất lượng cuối cùng và chứng nhận, đảm bảo pin an toàn trước khi đưa vào xe hoặc hệ thống lưu trữ năng lượng.

9. H: Nhiệt độ tối đa mà buồng thử nghiệm Derui có thể đạt được là bao nhiêu?
A: Máy thử nghiệm cháy tế bào pin xe điện Derui có phạm vi nhiệt độ ấn tượng, có thể đạt tới 1100°C (2000°F). Điều này đủ để mô phỏng các điều kiện cực đoan của một vụ cháy pin và sự mất kiểm soát nhiệt.

10. H: Derui có cung cấp dịch vụ lắp đặt và đào tạo không?
A: Luôn tốt nhất là kiểm tra trực tiếp với họ, nhưng các công ty bán thiết bị phòng thí nghiệm tinh vi như thế này thường cung cấp dịch vụ lắp đặt, vận hành và đào tạo ban đầu như một phần của gói dịch vụ. Sự nhấn mạnh của Derui về hỗ trợ sau bán hàng cho thấy họ sẽ cung cấp dịch vụ này để đảm bảo bạn có thể sử dụng máy thử một cách hiệu quả và an toàn.

11. H: Độ tin cậy của thiết bị thử nghiệm pin của Derui như thế nào?
A: Dựa trên chiến dịch marketing và sự hiện diện trong ngành, Derui dường như có danh tiếng vững chắc về độ tin cậy. Họ nhấn mạnh vào kết quả đã được chứng minh và sử dụng vật liệu bền như thép không gỉ. Để có câu trả lời chính xác, nên hỏi họ về tham khảo khách hàng hoặc các nghiên cứu điển hình từ các khách hàng hiện tại tại Việt Nam.

12. H: Máy thử này có thể dùng cho các module pin hệ thống lưu trữ năng lượng (ESS) không?
A: Trong khi mẫu cụ thể này được thiết kế cho các tế bào, công nghệ nền tảng và nguyên tắc an toàn giống nhau. Để thử nghiệm các ESS lớn hơn modules, bạn cần liên hệ với Derui để biết về buồng thử lớn hơn, tùy chỉnh theo kích thước hoặc một mẫu khác trong dòng sản phẩm của họ được thiết kế cho thử nghiệm ở cấp độ module.

13. H: Thời gian giao hàng sau khi đặt hàng máy thử nghiệm cháy của Derui là bao lâu?
A: Thời gian giao hàng có thể thay đổi dựa trên khối lượng đơn hàng và tùy chỉnh. Đối với một thiết bị tiêu chuẩn, có thể mất vài tháng, nhưng đối với hệ thống tùy chỉnh, thời gian có thể lâu hơn. Cách tốt nhất để có ước lượng đáng tin cậy về thời gian giao hàng là yêu cầu báo giá trực tiếp từ đội ngũ bán hàng của Derui, vì họ có thể cung cấp cho bạn lịch trình hiện tại.

14. H: Có các phương án tài chính nào cho thiết bị này không?
A: Có, Derui đề cập rằng họ cung cấp kế hoạch tài chính linh hoạt, bao gồm trả góp hàng tháng và thuê mua. Điều này khá phổ biến đối với thiết bị vốn đầu tư lớn và có thể giúp các startup hoặc phòng thí nghiệm nhỏ dễ dàng hơn trong việc sở hữu công nghệ thử nghiệm cần thiết.

15. H: Tại sao tôi nên chọn Derui thay vì các thương hiệu máy thử cháy pin khác?
A: Theo những gì tôi đã tổng hợp, lợi thế chính của Derui dường như là tập trung vào thị trường và tiêu chuẩn của Việt Nam, , thiết kế mô-đun và linh hoạt của buồng thử, và sự nhấn mạnh vào hỗ trợ sau bán hàng mạnh mẽ. Nếu bạn đánh giá cao một đối tác có thể cung cấp tùy chỉnh và dịch vụ lâu dài đáng tin cậy, họ chắc chắn xứng đáng để xem xét kỹ hơn so với các thương hiệu khác.