Máy kiểm tra ngắn mạch nội bộ bắt buộc của pin với điều khiển lực chính xác và kiểm soát nhiệt độ

The DERUI DR-D210 battery forced internal short circuit tester combines controlled mechanical force, temperature conditioning and synchronized cell-response monitoring. Its fixture and test sequence must be matched to the cell format and exact adopted procedure.

Mẫu DR-D210
Phạm vi Lực Published 0–2,000 N; force programme to confirm
Phạm vi Nhiệt độ Published 0°C to +100°C
Monitoring Force, voltage and temperature; channel and export scope to confirm
Cell Scope Fixture selected for the exact cylindrical or prismatic cell and method
Method Boundary Forced internal short circuit differs from UN 38.3 T.5 external short circuit
An toàn và đáng tin cậy
Chế tạo tốt
Đảm bảo chất lượng
Tùy chỉnh
Tin nhắnWhatsApp
Số điện thoại đường dây nóng 15580327593
  • Chi tiết sản phẩm
  • Câu hỏi thường gặp
  • Liên hệ với chúng tôi
Controlled Cell-Level Abuse Testing

DR-D210 Battery Forced Internal Short Circuit Tester

Apply controlled mechanical force to a prepared lithium-ion cell inside a temperature-controlled test enclosure while recording the cell response. DR-D210 is a specialized cell test system: the cell format, contact method, conditioning, force stop criterion and monitoring channels must be matched to the adopted procedure.

Method boundary: a mechanical forced internal short is different from connecting the external cell terminals together. The quoted fixture and test programme must be reviewed against the exact standard edition and specimen design.
Published force range0–2,000 N
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits0°C to +100°C
Published force accuracy±0.5% full scale; measurement basis to confirm
Published acquisition rateUp to 100 samples/s; channel scope to confirm

What the Test System Does

Controlled force application

The published servo system applies force while reporting the measured force and travel. Confirm the force ramp, actuator resolution and stop logic for the specified method.

Temperature conditioning

The integrated chamber provides a published 0–100°C range. Specify the required cell temperature, tolerance, soak time and measurement location.

Response monitoring

Cell voltage, surface temperature and actuator force can be captured during the event. Define channel count, sample rate per channel, trigger and exported record.

Published DR-D210 Values and Quotation Checks

Mục Published statement Confirm before ordering
Force range 0–2,000 N Calibrated measurement range, force resolution, ramp and permitted overload.
Độ chính xác lực ±0.5% full scale Whether this is force measurement or control accuracy; calibration evidence.
Phạm vi nhiệt độ 0°C to +100°C Stability, loaded performance, cell temperature sensor and conditioning duration.
Data acquisition Lên đến 100 mẫu mỗi giây Rate for each recorded channel, timestamps, trigger, storage and export format.
Control PLC and touchscreen Programme capacity, event stop conditions and user access controls.
Cell formats Cylindrical and prismatic cells described; other formats discussed as options Exact cell dimensions, contact position, fixture drawing and sample-preparation method.
Test enclosure Stainless-steel interior, observation window and exhaust described Final safety package, exhaust connection, emergency stop and facility interface.

Define the Test Method Before Selecting the Fixture

Adopt the exact document

Record the applicable standard, edition, clause, cell scope and laboratory procedure.

Prepare the cell

Define the permitted cell construction, charge state, conditioning and any controlled preparation required by the method.

Set the contact geometry

Approve the fixture, indenter/contact location, alignment and restraint for the selected cell format.

Set force and stop criteria

Specify force ramp, displacement, voltage event, maximum limits and safe-state response.

Record the response

Capture synchronized force, travel, voltage, temperature, event time and observations as required.

Apply the actual acceptance rule

Use the criteria in the adopted procedure and report deviations, venting or other abnormal events.

Fixture and Cell Scope

Định dạng cell cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Procurement evidence
Cylindrical Cell diameter/length, orientation, restraint and contact location Approved fixture drawing and representative-cell trial.
Prismatic Cell face, thickness, clamping and contact geometry Approved alignment drawing and travel clearance.
Dạng túi Method applicability, support surface, swelling clearance and damage risk Written method review before quoting a fixture; do not assume universal compatibility.
Multiple sizes Changeover time, fixture set and sensor repositioning Itemized fixture list and FAT with representative sizes.

Safety and Facility Interfaces

Function Required project definition
Enclosure and viewing Event energy, door/window construction, observation method and access interlock.
Exhaust Expected gas/smoke, connection size, flow, discharge route and facility approval.
Emergency stop Actuator stop, specimen power isolation, chamber response and restart permission.
Detection and alarms Which sensors are supplied, thresholds, calibration and cause-and-effect logic.
Post-event handling Remote observation, cooldown, ventilation, disposal and laboratory procedure.
Safety claim: the words “explosion-proof” on the existing page do not establish a certified containment rating. Confirm the actual design basis and any certificate applicable to the quoted configuration.

Use Standards for Their Actual Test Scope

Reference cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Decision for DR-D210
IEC 62133-2 Safety of portable sealed lithium cells and batteries Check the adopted edition and whether its forced-internal-short procedure applies to the intended cell; approve fixture and method before claiming support.
JIS C 8714 Japanese lithium-ion cell and battery safety requirements Confirm current applicable edition, specimen preparation and precise procedure.
IEC 62619 / IEC 62660-3 Industrial and automotive cell safety programmes Map the requested clause separately; these references do not make every DR-D210 function universally compliant.
UN 38.3 Lithium transport test programme T.5 is an external short-circuit test. This mechanical FISC tester is not a substitute for the UN 38.3 T.5 apparatus.

For transport-related low-pressure testing, review the separate DR-D203 battery altitude simulation chamber. It serves a different procedure and equipment purpose.

Records and Factory Acceptance

Force calibration

Check force-indication accuracy at agreed points and verify actuator travel, ramp and stop behaviour with a safe dummy specimen.

Temperature and channels

Map agreed temperature points and confirm voltage, temperature, force and displacement channels, timestamps and export.

Safety cause and effect

Demonstrate door interlock, emergency stop, overload, alarms, exhaust command and safe recovery without using a live cell for basic functional checks.

What to Send for an Accurate Proposal

Topic cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Method Standard, edition, clause, laboratory procedure and acceptance criteria.
Cells Chemistry, format, dimensions, capacity, energy, construction and quantities.
Preparation Permitted cell preparation, charge state, conditioning and handling.
Mechanical profile Fixture geometry, force range, ramp, travel and stop trigger.
Environment and records Temperature point, channels, sample rate, data format and report.
Facility safety Ventilation, exhaust, fire response, power and operator access controls.

Câu hỏi thường gặp

Is FISC the same as an external short-circuit test?

No. FISC uses a specified prepared cell and mechanical procedure to induce an internal event; an external short-circuit test connects the cell or battery terminals through an external circuit.

Can DR-D210 perform UN 38.3 T.5?

No such capability is established. T.5 is an external short-circuit test and requires a different test setup.

Does a 2,000 N maximum mean every cell uses 2,000 N?

No. The test programme sets the relevant force ramp and termination conditions for the selected cell and method. The published number is an equipment range limit.

Are all cell formats covered?

The current page describes cylindrical and prismatic cells and mentions other fixtures. Confirm method applicability and an approved fixture for each exact cell format.

Does the tester guarantee a pass under IEC 62133-2?

No. The applicable edition, specimen, preparation, test procedure and acceptance rule determine the result. Equipment capability and cell compliance are separate matters.

What should be witnessed at FAT?

Verify force and temperature measurements, channel timing/export, fixture fit, control sequence, interlocks, exhaust command and documentation using safe representative checks.

Specify the Cell and Procedure Before the Tester

Send the cell format, adopted method, preparation, force profile and safety requirements. DERUI can confirm the fixture, control range, monitoring channels and FAT scope for the quoted DR-D210 configuration.

Request a DR-D210 Method Review

FacebookLinkedInXRedditWhatsApp

1. Hỏi: Máy kiểm tra Ngắn mạch Nội bộ Bắt buộc của Pin là gì?
A: Trả lời: Máy kiểm tra Ngắn mạch Nội bộ Bắt buộc của Pin là một thiết bị kiểm tra an toàn chuyên dụng được thiết kế để cố ý gây ra và mô phỏng một ngắn mạch nội bộ trong tế bào pin lithium-ion. Nó áp dụng lực cơ học chính xác để mô phỏng các chế độ hỏng như phá vỡ lớp ngăn hoặc xâm nhập của dendrite, cho phép nhà sản xuất đánh giá phản ứng an toàn của tế bào, hành vi nhiệt và nguy cơ cháy nổ nhiệt trong điều kiện phòng thí nghiệm kiểm soát.

2. H: Sự khác biệt chính giữa kiểm tra đoản mạch nội bộ và đoản mạch bên ngoài là gì?
A: Sự khác biệt chính nằm ở vị trí lỗi và mục tiêu của bài kiểm tra. Một kiểm tra đoản mạch nội bộ (FISC) mô phỏng một lỗi bên trong pin (ví dụ, hỏng tấm ngăn) để đánh giá độ an toàn của lõi pin và nguy cơ quá nhiệt. Một kiểm tra đoản mạch bên ngoài kết nối các đầu ra bên ngoài của pin để đánh giá hệ thống quản lý pin và mạch bảo vệ bên ngoài. Kiểm tra FISC được xem là một phương pháp xác nhận an toàn nghiêm ngặt và cơ bản hơn.

3. H: Các tiêu chuẩn an toàn nào yêu cầu kiểm tra Đoản mạch nội bộ bắt buộc (FISC)?
A: Các tiêu chuẩn an toàn quốc tế chính yêu cầu hoặc đề xuất kiểm tra FISC bao gồm IEC 62133-2 (Điều khoản 8.3.9 cho pin di động), JIS C 8714:2007, và UL 1973 dành cho lưu trữ cố định. Nó cũng là một phương pháp đánh giá quan trọng trong IEC 62660-3 đối với pin ô tô và hỗ trợ xác nhận phù hợp với UN 38.3 yêu cầu an toàn vận chuyển.

4. H: Làm thế nào để máy kiểm tra FISC tạo ra lực để gây ra đoản mạch nội bộ?
A: Một máy kiểm tra FISC chất lượng cao sử dụng hệ thống động cơ servo chính xác cao để áp dụng một lực kiểm soát, dần dần (thường lên đến 2000 N) qua một đầu dò hoặc dụng cụ nhấn lên tế bào pin. Lực này làm biến dạng các lớp bên trong (âm cực, lớp ngăn cách, dương cực) cho đến khi chúng tiếp xúc, tạo ra một mạch ngắn bên trong được kiểm soát, đồng thời theo dõi các tham số như lực, dịch chuyển, điện áp và nhiệt độ theo thời gian thực.

5. H: Tại sao buồng nhiệt tích hợp lại quan trọng đối với kiểm tra FISC?
A: Hiệu suất an toàn của pin phụ thuộc rất nhiều vào nhiệt độ. Một buồng nhiệt tích hợp (ví dụ, phạm vi từ 0°C đến 100°C) cho phép kiểm tra trong các điều kiện môi trường khác nhau. Điều này rất quan trọng để đánh giá xem một tế bào có dễ bị quá nhiệt khi xảy ra mạch ngắn bên trong ở nhiệt độ cao hoặc thấp hay không, cung cấp dữ liệu an toàn toàn diện hơn.

6. H: Dữ liệu quan trọng nào được theo dõi trong quá trình kiểm tra FISC?
A: Trong quá trình kiểm tra, thiết bị theo dõi sụt giảm điện áp (để phát hiện mạch ngắn), nhiệt độ bề mặt và bên trong tế bào (để theo dõi sinh nhiệt và sự bắt đầu của quá nhiệt), và lực/dịch chuyển tác dụng. Các hệ thống tiên tiến lấy mẫu dữ liệu này với tốc độ cao (ví dụ, 100 mẫu/giây) để ghi lại chính xác chuỗi các sự kiện hỏng hóc nhanh chóng.

7. H: Các tính năng an toàn thiết yếu của thiết bị kiểm tra là gì?
A: Vì tính chất nguy hiểm của thử nghiệm, thiết bị kiểm tra phải có kết cấu chống nổ, một buồng an toàn kín có cửa sổ xem, một hệ thống dập cháy tự động (ví dụ, CO2), lỗ thoát khí độc hại, và nút dừng khẩn cấp. Những tính năng này bảo vệ người vận hành và thiết bị khỏi nguy cơ vỡ tế bào hoặc cháy nổ.

8. H: Các định dạng tế bào pin nào có thể được kiểm tra?
A: Máy kiểm tra FISC đa năng có thể phù hợp với tế bào hình khối, hình trụ và dạng túi. Điều này đạt được thông qua bộ gá tùy chỉnh và khuôn mẫu giữ chắc chắn từng loại tế bào tại chỗ trong quá trình áp dụng lực, đảm bảo điều kiện thử nghiệm nhất quán và đáng tin cậy trên các dòng sản phẩm khác nhau.

9. H: Kết quả Đạt/Không đạt được xác định như thế nào trong thử nghiệm FISC?
A: Tiêu chí Đạt/Không đạt được xác định bởi tiêu chuẩn an toàn liên quan (như IEC 62133-2). Thông thường, “đạt” yêu cầu tế bào không phát nổ hoặc bắt lửa. Các tiêu chí bổ sung thường bao gồm giới hạn về mức tăng nhiệt độ tối đa, thời gian của ngọn lửa (nếu có), và không có vật thể bay ra. Dữ liệu ghi lại của máy kiểm tra cung cấp bằng chứng cho đánh giá này.

10. H: Ai sử dụng thiết bị này và trong giai đoạn nào của quá trình sản xuất?
A: Máy kiểm tra FISC được sử dụng bởi nhà sản xuất tế bào pin, nhà tích hợp EV và ESS, và phòng thử nghiệm độc lập. Chúng chủ yếu được sử dụng trong giai đoạn Nghiên cứu và Phát triển để xác nhận vật liệu và thiết kế, và để kiểm tra đủ điều kiện và chứng nhận. Do tính chất phá hủy của nó, thường không sử dụng trên tất cả các tế bào trong sản xuất hàng loạt mà dựa trên mẫu để đảm bảo chất lượng.