Testador de Fogo de Células de Bateria de Veículos Elétricos

A DERUI DR-D211 EV battery cell fire tester applies a defined gas-flame exposure to a secured cell or small battery article. Specify the burner setup, measurement plan and dedicated fire-test room before ordering; this open-structure apparatus is not a sealed chamber or full-pack test bench.

Modelo DR-D211
Método de Teste External gas-flame exposure for R&D; exact procedure to confirm
Maximum Specimen 400 × 400 × 200 mm; ≤20 kg stated
Flame Height Published 100–150 mm; burner and measurement basis to confirm
Burning Time 1–60,000 s setting
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Open front/rear; dedicated fire room, exhaust and remote safety review required
Seguro e fiável
bem construído
Garantia de qualidade
personalização
MensagemWhatsApp
Número de Linha Direta 15580327593
  • Detalhes do Produto
  • Parâmetros técnicos
  • Perguntas Frequentes
  • Contacte-nos
DR-D211 · External Flame Exposure

EV Battery Cell Fire Tester for Controlled Flame Exposure

Expose a secured cell or small battery specimen to a defined gas flame and document how its casing, vent, nearby materials and fragments respond. DR-D211 is an open-front-and-rear fire-test apparatus, intended for a dedicated laboratory installation—not a sealed chamber or a full-pack fire-resistance bench.

Before selecting equipment: define the specimen's stored energy, the exact exposure method, burner geometry, measurement channels and site fire-safety plan. A published flame setting alone does not establish a certified test result.
ModeloDR-D211
Maximum stated specimen400 × 400 × 200 mm; ≤20 kg
Published flame height100–150 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits1–60,000 seconds

Use the Tester for the Right Question

Cell design screening

Compare casing, vent and shield behavior under a repeatable external-flame setup. Record specimen identity and condition for every run.

Small-assembly observation

Study ignition, burning and fragment behavior of a secured article that fits the published size and mass limits, subject to a facility hazard review.

Instrumented R&D

Add temperature, voltage, video or gas measurements only when the selected instrumentation and sampling plan are included in the approved configuration.

Not interchangeable: this external-flame device does not replace a battery crush tester, impact tester, calorimeter or thermal-runaway propagation laboratory.
DERUI EV battery cell fire tester product view
Existing product-gallery image. Confirm final delivered configuration against the approved drawing.

Published DR-D211 Configuration

These are the current page's published values. Terms such as “temperature accuracy” need a defined sensor position, operating condition and calibration method before they can become contractual acceptance criteria.

Item Published value Confirm before ordering
Model and specimen scope DR-D211; EV steel-shell battery stated Other cell formats, enclosure types and acceptable stored-energy limit.
Maximum article 400 × 400 × 200 mm; ≤20 kg Fixture space, clearance to burner and safe support load.
Altura da chama 100–150 mm Measurement method, fuel, pressure, burner geometry and distance to specimen.
Tempo de queima 1–60,000 s setting Timer start/stop points, flame-out handling and event log.
Temperature bands A: 300–600°C; B: 600–900°C; C: 900–1200°C; stated ±20°C Whether these describe burner settings, sensor ranges or measured specimen exposure; sensor and calibration location.
Ignition and air Automatic high-voltage pulse ignition stated; automatic air supply and airflow control Fuel type, supply pressure, ignition confirmation, flame supervision and shutoff logic.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Open front and rear; high-temperature-resistant insulation stated Dedicated room, extraction hood, exclusion zone and combustible clearances.
Alarm and protection Three-color status lamp, abnormal-operation alarm and limit protection stated Actual sensors, interlocks, emergency fuel isolation and alarm outputs.
Equipment dimensions Main unit 900 × 1140 × 1200 mm; console 600 × 400 × 1200 mm Final W × D × H drawing, service/access clearance and room layout.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits AC220 V Frequency, power/current, breaker, grounding and destination voltage.

Define a Repeatable Flame-Exposure Protocol

Identify the specimen

Record cell or assembly format, dimensions, mass, chemistry, capacity, state of charge and prior conditioning.

Choose the governing method

State the exact standard edition or internal procedure, specimen level and result criteria.

Specify the burner

Approve fuel, burner geometry, gas pressure, flame height, distance, airflow and pre-test verification.

Specify exposure timing

Define ignition, stabilization, start, dwell, termination and post-flame observation points.

Specify measurements

Select thermocouple locations, voltage channels, video, gas and other measurements with timestamps.

Agree on safety response

Review remote operation, fuel shutoff, extraction, emergency response, cooldown and specimen quarantine.

Standards: Method Match, Not a Blanket Claim

Reference What the buyer may need DR-D211 boundary
UL 9540A Thermal-runaway fire-propagation evaluation at defined specimen levels. The gas-flame apparatus is not a complete UL 9540A test system. A qualified laboratory must determine whether a specific R&D activity fits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits External-fire resistance procedure for a REESS/vehicle or representative subsystem. Its fuel-pan exposure, size and mounting are not automatically reproduced by this small gas-burner device.
Customer/OEM method Specified external-flame exposure of a cell or small article. Potential fit only after matching fixture, burner, measurements, hazard controls and acceptance criteria.

Do not list ASTM E3189 as a battery fire-test method; it addresses preparation of fire-debris samples for ignitable-liquid residue analysis.

Open Construction Makes the Test Room Part of the System

Because the published design is open at the front and rear, the equipment cannot be described as a sealed fire-containment chamber. Flame, smoke, hot gases, ejecta and electrolyte products may enter the surrounding space. Installation requires approval by the laboratory's fire and EHS specialists.

Gas and ignition

Specify fuel type, pressure regulation, leak detection, flame supervision and an accessible emergency shutoff.

Ventilation and separation

Engineer combustion exhaust and makeup air, restrict access during operation, and keep the console and personnel outside the hazard zone.

Post-event control

Define fire response, cooling, monitoring for re-ignition, quarantine and disposal for the actual cell chemistry and energy.

Configuration boundary: gas analysis, calorimetry, automatic suppression and detailed time-synchronized reports are not established as standard by the published DR-D211 parameter table. Quote them explicitly if required.

Recommended Factory and Site Acceptance Checks

Verificar Evidence to agree before shipment
Burner setup Fuel/pressure specification, measured flame height, fixture position and repeatability.
Temperature claim Sensor type, location, calibration and meaning of the A/B/C bands and ±20°C figure.
Timing and ignition Witnessed ignition sequence, timer behavior, flame-loss response and safe shutdown.
Specimen fixture Approved drawing for the 400 × 400 × 200 mm / ≤20 kg limit and required exposure surface.
Safety interfaces Emergency fuel isolation, alarm contacts, ventilation interlock and remote operation as contracted.
Documentação Operating manual, gas/electrical drawings, calibration scope and FAT report.

Perguntas Frequentes

What does the DR-D211 actually test?

It exposes a secured cell or small battery article to a controlled gas flame for a defined period so visible behavior and any specified instrument channels can be recorded.

Is this a sealed explosion-proof chamber?

No. The published design is open at the front and rear. The dedicated fire-test room, remote operation and engineered ventilation are part of the safety design.

Does DR-D211 alone meet UL 9540A?

No. UL 9540A addresses a broader thermal-runaway propagation test program. A qualified lab must assess any proposed use of this device within a specific research setup.

Can it perform UNECE R100 pack-level fire exposure?

Not from the published size and gas-burner arrangement. The R100 procedure has different specimen and fuel-pan requirements.

What do the 300–1200°C temperature bands mean?

The source does not define the measurement point clearly. Ask DERUI whether these are burner settings, sensor ranges or actual specimen exposure, and request calibration evidence.

Are gas analysis, fire suppression and automatic reports included?

They are not confirmed in the published technical table. Include each required sensor, control and output in the technical agreement.

Which specimens fit?

The published envelope is 400 × 400 × 200 mm and no more than 20 kg. Actual usable space and allowed stored energy also depend on the fixture and room safety review.

What should accompany an RFQ?

Send specimen data, chemistry, energy and state of charge, exact method, burner/fuel exposure, instrumentation, room layout, extraction, emergency strategy and acceptance criteria.

Review the Flame Test and Facility Together

Send the specimen drawing, stored energy, exposure method and room safety concept. DERUI can confirm whether DR-D211 fits your R&D task and document the required options and FAT checks.

Request a DR-D211 technical review

Send with your inquiry

  • Specimen size, mass, chemistry and SOC
  • Method, fuel and exposure profile
  • Measurement and reporting needs
  • Exhaust, gas and fire-safety plan
FacebookLinkedInXRedditWhatsApp
Modelo DR-D211
Faixa de temperatura Intervalo A 300-600℃
Intervalo B 600-900℃
Intervalo C 900-1200℃
Precisão ±20℃
Tamanho externo (L*P*A) 900*1140*1200mm
Tamanho do console (L*A*H) 600*400*1200mm
Especificações da bateria aplicável Casca de aço para veículos elétricos
Faixa de produtos compatíveis (L*A*H) 400*400*200mm
Peso da bateria ≤20KG
Tempo de queima 1s-60000s
Altura da chama 100-150mm
Estrutura do equipamento Aberto na frente e atrás
Mais leve Ignição automática de pacote de alta pressão
Método de fornecimento de ar Fornecimento automático de ar para atender a diferentes níveis de oxigénio
Material de isolamento Lã de rocha resistente a altas temperaturas
Velocidade do vento Controlo automático
Função de alarme Lâmpada dobrável de três cores, alarme de operação anormal
Função de proteção Proteção de limite, função à prova de erros, proteção de segurança
Material do equipamento Perfil de alumínio + chapa de aço laminado a frio, pintada, cor padrão cinza quente 1C (a cor pode ser personalizada)
Gás de combustão gás
Suporte ao solo Requer solo sólido, capacidade de carga de 1T/m3
Fonte de alimentação AC220V

1. P: O que é um testador de incêndio de célula de bateria de VE?
A: Um testador de incêndio de célula de bateria de VE é um equipamento de laboratório especializado projetado para incendiar intencionalmente células de bateria de íons de lítio sob condições controladas. É usado para estudar como as baterias se comportam durante a fuga térmica, como as chamas se propagam e para testar a resistência ao fogo, o que é crucial para garantir a segurança dos veículos elétricos.

2. P: Quanto custa uma câmara de teste de combustão de bateria?
A: O custo de uma câmara de teste de combustão de bateria pode variar bastante dependendo do seu tamanho, capacidades e personalizações. Para um modelo fiável como o Testador de Incêndio de Células de Bateria de VE Derui, é melhor contactar diretamente o fabricante para uma cotação precisa. Geralmente oferecem preços escalonados e descontos para encomendas em grande quantidade, o que pode tornar mais acessível para laboratórios que necessitam de várias unidades.

3. P: Quais características de segurança devo procurar num aparelho de teste de incêndio de bateria?
A: A segurança é primordial. Deve procurar características como um sistema automático de supressão de incêndios, monitorização de gás e temperatura em tempo real, e um interruptor de emergência. O testador da Derui, por exemplo, inclui todos estes, além de bloqueios de segurança no sistema de ignição, que é uma característica chave para evitar operação acidental.

4. P: O testador de incêndio da Derui está em conformidade com os padrões UL 9540A?
A: Sim, absolutamente. O Testador de Incêndio de Células de Bateria de VE Derui foi especificamente desenhado para suportar testes de acordo com UL 9540A, juntamente com outros padrões importantes como ASTM E3189 e GB/T 31485. Isto faz dele uma escolha sólida para quem precisa certificar as suas células ou sistemas de bateria para o mercado.

5. P: Posso testar diferentes tamanhos de células de bateria com uma única máquina?
A: Boa pergunta! Muitos testadores têm câmaras fixas, mas o modelo da Derui utiliza uma design de câmara modular. Isto significa que pode ajustar ou reconfigurar a configuração para acomodar diferentes tamanhos e formatos de células de bateria, desde pequenas células cilíndricas até maiores bolsas, o que oferece grande flexibilidade para um laboratório de P&D.

6. P: Que tipo de dados o testador de chama de bateria Derui recolhe?
A: Recolhe dados abrangentes e de alta resolução que são críticos para análise. Obtém perfis de temperatura de múltiplos pontos, alterações de pressão dentro da câmara, e com acessórios opcionais, pode até analisar as emissões de gás produzidas durante a combustão. Estes dados são essenciais para compreender os modos de falha.

7. P: O sistema é difícil de operar para técnicos novos?
A: Pelos especificações do produto, parece que priorizaram a facilidade de uso. Vem com uma interface intuitiva de ecrã tátil e guias de configuração claras. Embora seja sempre necessário um treino adequado para este tipo de equipamento especializado, a curva de aprendizagem deve ser gerível, permitindo que técnicos novos se adaptem relativamente rápido.

8. P: Quem costuma usar este tipo de dispositivo de simulação de incêndio de bateria de VE?
A: Os principais utilizadores são fabricantes de baterias de VE, laboratórios de testes de terceiros, e instituições de investigação. Utilizam-no para tudo, desde a fase inicial de P&D até aos testes finais de garantia de qualidade e certificação, garantindo que as baterias são seguras antes de serem instaladas em veículos ou sistemas de armazenamento de energia.

9. P: Qual é a temperatura máxima que a câmara de teste Derui pode atingir?
A: O Testador de Incêndio de Células de Bateria EV Derui tem uma impressionante gama de temperaturas, capaz de atingir até 1100°C (2000°F). Isto é mais do que suficiente para simular as condições extremas de um incêndio de bateria e um evento de fuga térmica.

10. P: A Derui oferece serviços de instalação e formação?
A: É sempre melhor verificar diretamente com eles, mas as empresas que vendem equipamentos de laboratório sofisticados como este normalmente oferecem instalação, colocação em funcionamento e formação inicial como parte do seu pacote de serviços. A ênfase da Derui no apoio pós-venda sugere que eles forneceriam isto para garantir que pode usar o testador de forma eficaz e segura.

11. P: Quão fiável é o equipamento de teste de baterias da Derui?
A: Com base no seu marketing e presença na indústria, a Derui parece ter uma forte reputação de fiabilidade. Eles destacam o seu historial comprovado e o uso de materiais duráveis como o aço inoxidável. Para uma resposta definitiva, seria sensato pedir-lhes referências de clientes ou estudos de caso de clientes portugueses existentes.

12. P: Este testador pode ser usado para módulos de bateria de sistemas de armazenamento de energia (ESS)?
A: Embora este modelo específico seja projetado para células, individuais, a tecnologia subjacente e os princípios de segurança são os mesmos. Para testar ESS módulos, maiores, precisaria de consultar a Derui sobre uma câmara maior, de tamanho personalizado, ou um modelo diferente na sua linha de produtos projetado para testes ao nível do módulo.

13. P: Qual é o prazo de entrega após encomendar um testador de incêndio Derui?
A: Os prazos de entrega podem variar com base no volume de encomendas e na personalização. Para uma unidade padrão, pode ser alguns meses, mas para um sistema personalizado, pode ser mais longo. A melhor maneira de obter uma estimativa de entrega fiável é solicitar um orçamento diretamente à equipa de vendas da Derui, pois eles podem dar-lhe um cronograma atual.

14. P: Existem opções de financiamento disponíveis para este equipamento?
A: Sim, a Derui menciona que oferece planos de financiamento flexíveis, incluindo prestações mensais e opções de leasing. Isto é bastante comum para equipamentos de capital de alto custo e pode facilitar para startups ou laboratórios menores adquirirem a tecnologia de teste necessária.

15. P: Por que devo escolher a Derui em vez de outras marcas de testadores de incêndio de baterias?
A: Pelo que percebi, as principais vantagens da Derui parecem ser o seu foco no mercado e padrões de Portugal, o design modular e flexível do seu compartimento, e a sua ênfase em suporte pós-venda forte. Se valoriza um parceiro que pode fornecer personalização e um serviço confiável a longo prazo, eles definitivamente merecem uma análise mais detalhada em comparação com outras marcas.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MensagemMensagem

Solicitar Orçamento