Calle Shugang 1, No. 3, Town de Hongmei, Ciudad de Dongguan, Provincia de Guangdong, China

Fabricante de cámaras de prueba ambiental con 20 años de experienciaMás de 3000 entregas a clientes en todo el mundo           Correo electrónico: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Probador de incendios de celdas de batería de vehículo eléctrico

La DERUI DR-D211 EV battery cell fire tester applies a defined gas-flame exposure to a secured cell or small battery article. Specify the burner setup, measurement plan and dedicated fire-test room before ordering; this open-structure apparatus is not a sealed chamber or full-pack test bench.

Modelo DR-D211
Método de Prueba External gas-flame exposure for R&D; exact procedure to confirm
Maximum Specimen 400 × 400 × 200 mm; ≤20 kg stated
Flame Height Published 100–150 mm; burner and measurement basis to confirm
Burning Time 1–60,000 s setting
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Open front/rear; dedicated fire room, exhaust and remote safety review required
Segura y confiable
bien hecha
Garantía de calidad
personalización
MensajeWhatsApp
Número de línea directa 15580327593
  • Detalles del producto
  • Parámetros técnicos
  • Preguntas frecuentes
  • Contáctanos
DR-D211 · External Flame Exposure

EV Battery Cell Fire Tester for Controlled Flame Exposure

Expose a secured cell or small battery specimen to a defined gas flame and document how its casing, vent, nearby materials and fragments respond. DR-D211 is an open-front-and-rear fire-test apparatus, intended for a dedicated laboratory installation—not a sealed chamber or a full-pack fire-resistance bench.

Before selecting equipment: define the specimen's stored energy, the exact exposure method, burner geometry, measurement channels and site fire-safety plan. A published flame setting alone does not establish a certified test result.
ModeloDR-D211
Maximum stated specimen400 × 400 × 200 mm; ≤20 kg
Published flame height100–150 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits1–60,000 seconds

Use the Tester for the Right Question

Cell design screening

Compare casing, vent and shield behavior under a repeatable external-flame setup. Record specimen identity and condition for every run.

Small-assembly observation

Study ignition, burning and fragment behavior of a secured article that fits the published size and mass limits, subject to a facility hazard review.

Instrumented R&D

Add temperature, voltage, video or gas measurements only when the selected instrumentation and sampling plan are included in the approved configuration.

Not interchangeable: this external-flame device does not replace a battery crush tester, impact tester, calorimeter or thermal-runaway propagation laboratory.
DERUI EV battery cell fire tester product view
Existing product-gallery image. Confirm final delivered configuration against the approved drawing.

Published DR-D211 Configuration

These are the current page's published values. Terms such as “temperature accuracy” need a defined sensor position, operating condition and calibration method before they can become contractual acceptance criteria.

Artículo Published value Confirm before ordering
Model and specimen scope DR-D211; EV steel-shell battery stated Other cell formats, enclosure types and acceptable stored-energy limit.
Maximum article 400 × 400 × 200 mm; ≤20 kg Fixture space, clearance to burner and safe support load.
Altura de la llama 100–150 mm Measurement method, fuel, pressure, burner geometry and distance to specimen.
Tiempo de combustión 1–60,000 s setting Timer start/stop points, flame-out handling and event log.
Temperature bands A: 300–600°C; B: 600–900°C; C: 900–1200°C; stated ±20°C Whether these describe burner settings, sensor ranges or measured specimen exposure; sensor and calibration location.
Ignition and air Automatic high-voltage pulse ignition stated; automatic air supply and airflow control Fuel type, supply pressure, ignition confirmation, flame supervision and shutoff logic.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Open front and rear; high-temperature-resistant insulation stated Dedicated room, extraction hood, exclusion zone and combustible clearances.
Alarm and protection Three-color status lamp, abnormal-operation alarm and limit protection stated Actual sensors, interlocks, emergency fuel isolation and alarm outputs.
Equipment dimensions Main unit 900 × 1140 × 1200 mm; console 600 × 400 × 1200 mm Final W × D × H drawing, service/access clearance and room layout.
Electrical supply AC220 V Frequency, power/current, breaker, grounding and destination voltage.

Define a Repeatable Flame-Exposure Protocol

Identify the specimen

Record cell or assembly format, dimensions, mass, chemistry, capacity, state of charge and prior conditioning.

Choose the governing method

State the exact standard edition or internal procedure, specimen level and result criteria.

Specify the burner

Approve fuel, burner geometry, gas pressure, flame height, distance, airflow and pre-test verification.

Specify exposure timing

Define ignition, stabilization, start, dwell, termination and post-flame observation points.

Specify measurements

Select thermocouple locations, voltage channels, video, gas and other measurements with timestamps.

Agree on safety response

Review remote operation, fuel shutoff, extraction, emergency response, cooldown and specimen quarantine.

Standards: Method Match, Not a Blanket Claim

Reference What the buyer may need DR-D211 boundary
UL 9540A Thermal-runaway fire-propagation evaluation at defined specimen levels. The gas-flame apparatus is not a complete UL 9540A test system. A qualified laboratory must determine whether a specific R&D activity fits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits External-fire resistance procedure for a REESS/vehicle or representative subsystem. Its fuel-pan exposure, size and mounting are not automatically reproduced by this small gas-burner device.
Customer/OEM method Specified external-flame exposure of a cell or small article. Potential fit only after matching fixture, burner, measurements, hazard controls and acceptance criteria.

Do not list ASTM E3189 as a battery fire-test method; it addresses preparation of fire-debris samples for ignitable-liquid residue analysis.

Open Construction Makes the Test Room Part of the System

Because the published design is open at the front and rear, the equipment cannot be described as a sealed fire-containment chamber. Flame, smoke, hot gases, ejecta and electrolyte products may enter the surrounding space. Installation requires approval by the laboratory's fire and EHS specialists.

Gas and ignition

Specify fuel type, pressure regulation, leak detection, flame supervision and an accessible emergency shutoff.

Ventilation and separation

Engineer combustion exhaust and makeup air, restrict access during operation, and keep the console and personnel outside the hazard zone.

Post-event control

Define fire response, cooling, monitoring for re-ignition, quarantine and disposal for the actual cell chemistry and energy.

Configuration boundary: gas analysis, calorimetry, automatic suppression and detailed time-synchronized reports are not established as standard by the published DR-D211 parameter table. Quote them explicitly if required.

Recommended Factory and Site Acceptance Checks

Verificar Evidence to agree before shipment
Burner setup Fuel/pressure specification, measured flame height, fixture position and repeatability.
Temperature claim Sensor type, location, calibration and meaning of the A/B/C bands and ±20°C figure.
Timing and ignition Witnessed ignition sequence, timer behavior, flame-loss response and safe shutdown.
Specimen fixture Approved drawing for the 400 × 400 × 200 mm / ≤20 kg limit and required exposure surface.
Safety interfaces Emergency fuel isolation, alarm contacts, ventilation interlock and remote operation as contracted.
Documentación Operating manual, gas/electrical drawings, calibration scope and FAT report.

Preguntas Frecuentes

What does the DR-D211 actually test?

It exposes a secured cell or small battery article to a controlled gas flame for a defined period so visible behavior and any specified instrument channels can be recorded.

Is this a sealed explosion-proof chamber?

No. The published design is open at the front and rear. The dedicated fire-test room, remote operation and engineered ventilation are part of the safety design.

Does DR-D211 alone meet UL 9540A?

No. UL 9540A addresses a broader thermal-runaway propagation test program. A qualified lab must assess any proposed use of this device within a specific research setup.

Can it perform UNECE R100 pack-level fire exposure?

Not from the published size and gas-burner arrangement. The R100 procedure has different specimen and fuel-pan requirements.

What do the 300–1200°C temperature bands mean?

The source does not define the measurement point clearly. Ask DERUI whether these are burner settings, sensor ranges or actual specimen exposure, and request calibration evidence.

Are gas analysis, fire suppression and automatic reports included?

They are not confirmed in the published technical table. Include each required sensor, control and output in the technical agreement.

Which specimens fit?

The published envelope is 400 × 400 × 200 mm and no more than 20 kg. Actual usable space and allowed stored energy also depend on the fixture and room safety review.

What should accompany an RFQ?

Send specimen data, chemistry, energy and state of charge, exact method, burner/fuel exposure, instrumentation, room layout, extraction, emergency strategy and acceptance criteria.

Review the Flame Test and Facility Together

Send the specimen drawing, stored energy, exposure method and room safety concept. DERUI can confirm whether DR-D211 fits your R&D task and document the required options and FAT checks.

Request a DR-D211 technical review

Send with your inquiry

  • Specimen size, mass, chemistry and SOC
  • Method, fuel and exposure profile
  • Measurement and reporting needs
  • Exhaust, gas and fire-safety plan
FacebookLinkedInXRedditWhatsApp
Modelo DR-D211
Rango de temperatura Intervalo A 300-600℃
Intervalo B 600-900℃
Intervalo C 900-1200℃
Precisión ±20℃
Tamaño externo (An*Pr*Al) 900*1140*1200mm
Tamaño de la consola (An*Pr*Al) 600*400*1200mm
Especificaciones de batería aplicables Carcasa de acero para vehículos eléctricos
Rango de productos compatibles (An*Pr*Al) 400*400*200mm
Peso de la batería ≤20KG
Tiempo de combustión 1s-60000s
Altura de la llama 100-150mm
Estructura del equipo Frontal y trasero abiertos
Encendedor Encendido automático de paquete de alta presión
Método de suministro de aire Suministro de aire automático para satisfacer diferentes niveles de oxígeno
Material de aislamiento Lana de roca ignífuga resistente a altas temperaturas
Velocidad del viento Control automático
Función de alarma Lámpara plegable de tres colores, alarma de operación anormal
Función de protección Protección límite, función a prueba de errores, protección de seguridad
Material del equipo Perfil de aluminio + placa de acero laminado en frío, pintado, el color estándar es gris cálido 1C (el color puede ser personalizado)
Gases de combustión Gas
Soporte en tierra Requiere suelo sólido, soporte de 1T/m3
Fuente de alimentación AC220V

1. P: ¿Qué es un probador de incendios de celdas de batería de vehículo eléctrico?
A: Un probador de incendios de celdas de batería de vehículo eléctrico es un equipo de laboratorio especializado diseñado para incendiar intencionadamente celdas de baterías de iones de litio bajo condiciones controladas. Se utiliza para estudiar cómo se comportan las baterías durante una fuga térmica, cómo se propagan las llamas y para probar su resistencia al fuego, lo cual es crucial para garantizar la seguridad de los vehículos eléctricos.

2. P: ¿Cuánto cuesta una cámara de prueba de combustión de baterías?
A: El costo de una cámara de prueba de combustión de baterías puede variar ampliamente según su tamaño, capacidades y personalizaciones. Para un modelo confiable como el Probador de Incendios de Celdas de Batería EV Derui, lo mejor es contactar directamente con el fabricante para obtener una cotización precisa. A menudo ofrecen precios escalonados y descuentos por pedidos en volumen, lo que puede hacer que sea más asequible para laboratorios que necesitan varias unidades.

3. P: ¿Qué características de seguridad debo buscar en un aparato de prueba de incendios de baterías?
A: La seguridad es primordial. Sin duda, debe buscar características como un sistema automático de supresión de incendios, monitoreo en tiempo real de gases y temperatura, y un interruptor de apagado de emergencia. El probador de Derui, por ejemplo, incluye todos estos, además de bloqueos de seguridad en el sistema de ignición, que es una característica clave para prevenir operaciones accidentales.

4. P: ¿Cumple el probador de incendios de Derui con las normas UL 9540A?
A: Sí, absolutamente. El Probador de Incendios de Celdas de Batería EV Derui está diseñado específicamente para soportar pruebas de acuerdo con UL 9540A, junto con otras normas clave como ASTM E3189 y GB/T 31485. Esto lo convierte en una opción sólida para quienes necesitan certificar sus celdas o sistemas de baterías para el mercado.

5. P: ¿Puedo probar diferentes tamaños de celdas de batería con una sola máquina?
A: ¡Buena pregunta! Muchos probadores tienen cámaras fijas, pero el modelo Derui utiliza un diseño de cámara modular. Esto significa que puede ajustar o reconfigurar la configuración para acomodar diferentes tamaños y formatos de celdas de batería, desde celdas cilíndricas pequeñas hasta bolsas más grandes, lo que ofrece una gran flexibilidad para un laboratorio de I+D.

6. P: ¿Qué tipo de datos recopila el probador de llamas de baterías Derui?
A: Recoge datos completos y de alta resolución que son críticos para el análisis. Obtienes perfiles de temperatura precisos desde múltiples puntos, cambios de presión dentro de la cámara, y con complementos opcionales, incluso puedes analizar las emisiones de gases producidas durante la combustión. Estos datos son vitales para entender los modos de fallo.

7. P: ¿Es difícil operar el sistema para técnicos nuevos?
A: Por las especificaciones del producto, parece que han priorizado la facilidad de uso. Viene con una interfaz táctil intuitiva y guías de configuración claras. Aunque siempre se necesita una formación adecuada para este tipo de equipos especializados, la curva de aprendizaje debería ser manejable, permitiendo que los técnicos nuevos se pongan al día relativamente rápido.

8. P: ¿Quiénes suelen usar este tipo de dispositivo de simulación de incendios en baterías de vehículos eléctricos?
A: Los usuarios principales son Fabricantes de baterías de vehículos eléctricos, laboratorios de pruebas independientes, y instituciones de investigación. Lo utilizan para todo, desde I+D en etapas tempranas hasta pruebas de aseguramiento de calidad y certificación final, garantizando que las baterías sean seguras antes de que se integren en coches o sistemas de almacenamiento de energía.

9. P: ¿Cuál es la temperatura máxima que puede alcanzar la cámara de prueba Derui?
A: El probador de incendios de celdas de batería de vehículos eléctricos Derui tiene un rango de temperatura impresionante, capaz de alcanzar hasta 1100°C (2000°F). Esto es más que suficiente para simular las condiciones extremas de un incendio de batería y un evento de fuga térmica.

10. P: ¿Ofrece Derui servicios de instalación y formación?
A: Siempre es mejor consultarlo directamente con ellos, pero las empresas que venden equipos de laboratorio sofisticados como este suelen ofrecer instalación, puesta en marcha y formación inicial como parte de su paquete de servicios. El énfasis de Derui en el soporte postventa sugiere que proporcionarían esto para que puedas usar el probador de manera efectiva y segura.

11. P: ¿Qué tan fiable es el equipo de prueba de baterías de Derui?
A: Basándose en su marketing y presencia en la industria, Derui parece tener una sólida reputación de fiabilidad. Destacan su historial probado y el uso de materiales duraderos como el acero inoxidable. Para una respuesta definitiva, sería prudente pedirles referencias de clientes o estudios de casos de clientes existentes en España.

12. P: ¿Se puede utilizar este probador para módulos de baterías de sistemas de almacenamiento de energía (ESS)?
A: Si bien este modelo específico está diseñado para celdas, individuales, la tecnología subyacente y los principios de seguridad son los mismos. Para probar ESS más grandes módulos, tendría que consultar con Derui sobre una cámara más grande y de tamaño personalizado o un modelo diferente en su línea de productos diseñado para pruebas a nivel de módulo.

13. P: ¿Cuál es el plazo de entrega después de ordenar un probador de fuego Derui?
A: Los plazos de entrega pueden variar según el volumen del pedido y la personalización. Para una unidad estándar, podría ser de unos pocos meses, pero para un sistema personalizado, podría ser más largo. La mejor manera de obtener una estimación de entrega fiable es solicitar un presupuesto directamente al equipo de ventas de Derui, ya que pueden darle un cronograma actual.

14. P: ¿Existen opciones de financiación disponibles para este equipo?
A: Sí, Derui menciona que ofrecen planes de financiación flexibles, incluyendo cuotas mensuales y opciones de arrendamiento. Esto es bastante común para equipos de capital de alto costo y puede facilitar a las empresas emergentes o laboratorios más pequeños la adquisición de la tecnología de prueba necesaria.

15. P: ¿Por qué debería elegir Derui en lugar de otras marcas de probadores de incendios de baterías?
A: Por lo que he recopilado, las ventajas clave de Derui parecen ser su enfoque en el mercado y los estándares de España, el diseño modular y flexible de su cámara, y su énfasis en un sólido soporte postventa. Si valoras un socio que pueda ofrecer personalización y un servicio confiable a largo plazo, definitivamente vale la pena considerarlo en comparación con otras marcas.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MensajeMensaje

Solicitar una Cotización