EV-Batteriezellfeuertester

Das DERUI DR-D211 EV battery cell fire tester applies a defined gas-flame exposure to a secured cell or small battery article. Specify the burner setup, measurement plan and dedicated fire-test room before ordering; this open-structure apparatus is not a sealed chamber or full-pack test bench.

Modell DR-D211
Testmethode External gas-flame exposure for R&D; exact procedure to confirm
Maximum Specimen 400 × 400 × 200 mm; ≤20 kg stated
Flame Height Published 100–150 mm; burner and measurement basis to confirm
Burning Time 1–60,000 s setting
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Open front/rear; dedicated fire room, exhaust and remote safety review required
Sicher und zuverlässig
Hochwertig hergestellt
Qualitätssicherung
Anpassung
NachrichtWhatsApp
Hotline-Nummer 15580327593
  • Produktdetails
  • Technische Parameter
  • FAQ
  • Kontaktieren Sie uns
DR-D211 · External Flame Exposure

EV Battery Cell Fire Tester for Controlled Flame Exposure

Expose a secured cell or small battery specimen to a defined gas flame and document how its casing, vent, nearby materials and fragments respond. DR-D211 is an open-front-and-rear fire-test apparatus, intended for a dedicated laboratory installation—not a sealed chamber or a full-pack fire-resistance bench.

Before selecting equipment: define the specimen's stored energy, the exact exposure method, burner geometry, measurement channels and site fire-safety plan. A published flame setting alone does not establish a certified test result.
ModellDR-D211
Maximum stated specimen400 × 400 × 200 mm; ≤20 kg
Published flame height100–150 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits1–60,000 seconds

Use the Tester for the Right Question

Cell design screening

Compare casing, vent and shield behavior under a repeatable external-flame setup. Record specimen identity and condition for every run.

Small-assembly observation

Study ignition, burning and fragment behavior of a secured article that fits the published size and mass limits, subject to a facility hazard review.

Instrumented R&D

Add temperature, voltage, video or gas measurements only when the selected instrumentation and sampling plan are included in the approved configuration.

Not interchangeable: this external-flame device does not replace a battery crush tester, impact tester, calorimeter or thermal-runaway propagation laboratory.
DERUI EV battery cell fire tester product view
Existing product-gallery image. Confirm final delivered configuration against the approved drawing.

Published DR-D211 Configuration

These are the current page's published values. Terms such as “temperature accuracy” need a defined sensor position, operating condition and calibration method before they can become contractual acceptance criteria.

Artikel Published value Confirm before ordering
Model and specimen scope DR-D211; EV steel-shell battery stated Other cell formats, enclosure types and acceptable stored-energy limit.
Maximum article 400 × 400 × 200 mm; ≤20 kg Fixture space, clearance to burner and safe support load.
Flammenhöhe 100–150 mm Measurement method, fuel, pressure, burner geometry and distance to specimen.
Brennzeit 1–60,000 s setting Timer start/stop points, flame-out handling and event log.
Temperature bands A: 300–600°C; B: 600–900°C; C: 900–1200°C; stated ±20°C Whether these describe burner settings, sensor ranges or measured specimen exposure; sensor and calibration location.
Ignition and air Automatic high-voltage pulse ignition stated; automatic air supply and airflow control Fuel type, supply pressure, ignition confirmation, flame supervision and shutoff logic.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Open front and rear; high-temperature-resistant insulation stated Dedicated room, extraction hood, exclusion zone and combustible clearances.
Alarm and protection Three-color status lamp, abnormal-operation alarm and limit protection stated Actual sensors, interlocks, emergency fuel isolation and alarm outputs.
Equipment dimensions Main unit 900 × 1140 × 1200 mm; console 600 × 400 × 1200 mm Final W × D × H drawing, service/access clearance and room layout.
Electrical supply AC220 V Frequency, power/current, breaker, grounding and destination voltage.

Define a Repeatable Flame-Exposure Protocol

Identify the specimen

Record cell or assembly format, dimensions, mass, chemistry, capacity, state of charge and prior conditioning.

Choose the governing method

State the exact standard edition or internal procedure, specimen level and result criteria.

Specify the burner

Approve fuel, burner geometry, gas pressure, flame height, distance, airflow and pre-test verification.

Specify exposure timing

Define ignition, stabilization, start, dwell, termination and post-flame observation points.

Specify measurements

Select thermocouple locations, voltage channels, video, gas and other measurements with timestamps.

Agree on safety response

Review remote operation, fuel shutoff, extraction, emergency response, cooldown and specimen quarantine.

Standards: Method Match, Not a Blanket Claim

Reference What the buyer may need DR-D211 boundary
UL 9540A Thermal-runaway fire-propagation evaluation at defined specimen levels. The gas-flame apparatus is not a complete UL 9540A test system. A qualified laboratory must determine whether a specific R&D activity fits.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits External-fire resistance procedure for a REESS/vehicle or representative subsystem. Its fuel-pan exposure, size and mounting are not automatically reproduced by this small gas-burner device.
Customer/OEM method Specified external-flame exposure of a cell or small article. Potential fit only after matching fixture, burner, measurements, hazard controls and acceptance criteria.

Do not list ASTM E3189 as a battery fire-test method; it addresses preparation of fire-debris samples for ignitable-liquid residue analysis.

Open Construction Makes the Test Room Part of the System

Because the published design is open at the front and rear, the equipment cannot be described as a sealed fire-containment chamber. Flame, smoke, hot gases, ejecta and electrolyte products may enter the surrounding space. Installation requires approval by the laboratory's fire and EHS specialists.

Gas and ignition

Specify fuel type, pressure regulation, leak detection, flame supervision and an accessible emergency shutoff.

Ventilation and separation

Engineer combustion exhaust and makeup air, restrict access during operation, and keep the console and personnel outside the hazard zone.

Post-event control

Define fire response, cooling, monitoring for re-ignition, quarantine and disposal for the actual cell chemistry and energy.

Configuration boundary: gas analysis, calorimetry, automatic suppression and detailed time-synchronized reports are not established as standard by the published DR-D211 parameter table. Quote them explicitly if required.

Recommended Factory and Site Acceptance Checks

Überprüfen Evidence to agree before shipment
Burner setup Fuel/pressure specification, measured flame height, fixture position and repeatability.
Temperature claim Sensor type, location, calibration and meaning of the A/B/C bands and ±20°C figure.
Timing and ignition Witnessed ignition sequence, timer behavior, flame-loss response and safe shutdown.
Specimen fixture Approved drawing for the 400 × 400 × 200 mm / ≤20 kg limit and required exposure surface.
Safety interfaces Emergency fuel isolation, alarm contacts, ventilation interlock and remote operation as contracted.
Dokumentation Operating manual, gas/electrical drawings, calibration scope and FAT report.

Häufig gestellte Fragen

What does the DR-D211 actually test?

It exposes a secured cell or small battery article to a controlled gas flame for a defined period so visible behavior and any specified instrument channels can be recorded.

Is this a sealed explosion-proof chamber?

No. The published design is open at the front and rear. The dedicated fire-test room, remote operation and engineered ventilation are part of the safety design.

Does DR-D211 alone meet UL 9540A?

No. UL 9540A addresses a broader thermal-runaway propagation test program. A qualified lab must assess any proposed use of this device within a specific research setup.

Can it perform UNECE R100 pack-level fire exposure?

Not from the published size and gas-burner arrangement. The R100 procedure has different specimen and fuel-pan requirements.

What do the 300–1200°C temperature bands mean?

The source does not define the measurement point clearly. Ask DERUI whether these are burner settings, sensor ranges or actual specimen exposure, and request calibration evidence.

Are gas analysis, fire suppression and automatic reports included?

They are not confirmed in the published technical table. Include each required sensor, control and output in the technical agreement.

Which specimens fit?

The published envelope is 400 × 400 × 200 mm and no more than 20 kg. Actual usable space and allowed stored energy also depend on the fixture and room safety review.

What should accompany an RFQ?

Send specimen data, chemistry, energy and state of charge, exact method, burner/fuel exposure, instrumentation, room layout, extraction, emergency strategy and acceptance criteria.

Review the Flame Test and Facility Together

Send the specimen drawing, stored energy, exposure method and room safety concept. DERUI can confirm whether DR-D211 fits your R&D task and document the required options and FAT checks.

Request a DR-D211 technical review

Send with your inquiry

  • Specimen size, mass, chemistry and SOC
  • Method, fuel and exposure profile
  • Measurement and reporting needs
  • Exhaust, gas and fire-safety plan
FacebookLinkedInXRedditWhatsApp
Modell DR-D211
Temperaturbereich Intervall A 300-600℃
Intervall B 600-900℃
Intervall C 900-1200℃
Präzision ±20℃
Außenmaße (B*T*H) 900*1140*1200mm
Gerätegröße (B*T*H) 600*400*1200mm
Anwendbare Batteriespezifikationen EV-Stahlgehäuse
Kompatibler Produktbereich (B*T*H) 400*400*200mm
Batteriegewicht ≤20KG
Brennzeit 1s-60000s
Flammenhöhe 100-150mm
Geräteaufbau Offen vorne und hinten
Feuerzeug Automatische Hochdruckverpackungszündung
Luftzufuhrmethode Automatische Luftzufuhr zur Erfüllung unterschiedlicher Sauerstoffwerte
Isolationsmaterial Hochtemperaturbeständiger Feuersteinwolle
Windgeschwindigkeit Automatische Steuerung
Alarmfunktion Faltbare Dreifarbenlampe, Alarm bei abnormalem Betrieb
Schutzfunktion Grenzschutz, Fehlersicherungsfunktion, Sicherheitsvorkehrungen
Gerätematerial Aluminiumprofil + kaltgewalzter Stahlplatte, lackiert, Standardfarbe ist Warmgrau 1C (Farbe kann angepasst werden)
Verbrennungsgase Gas
Bodenauflagerung Erfordert festen Boden, Tragfähigkeit 1T/m3
Stromversorgung AC220V

1. F: Was ist ein EV-Batteriezellfeuerprüfer?
A: Ein EV-Batteriezellfeuerprüfer ist ein spezielles Laborequipment, das entwickelt wurde, um Lithium-Ionen-Batteriezellen unter kontrollierten Bedingungen absichtlich in Brand zu setzen. Es wird verwendet, um das Verhalten von Batterien bei thermischem Durchbruch zu untersuchen, wie sich Flammen ausbreiten und um ihre Feuerwiderstandsfähigkeit zu testen, was entscheidend für die Sicherheit von Elektrofahrzeugen ist.

2. F: Wie viel kostet eine Batterie-Verbrennungstestkammer?
A: Die Kosten für eine Batterie-Verbrennungstestkammer können stark variieren, abhängig von Größe, Fähigkeiten und Anpassungen. Für ein zuverlässiges Modell wie den Derui EV-Batteriezellfeuerprüfer ist es am besten, direkt den Hersteller zu kontaktieren, um ein genaues Angebot zu erhalten. Sie bieten oft gestaffelte Preise und Rabatte für Großbestellungen an, was es für Labore, die mehrere Einheiten benötigen, erschwinglicher macht.

3. F: Welche Sicherheitsmerkmale sollte ich bei einem Batterie-Feuertestgerät beachten?
A: Sicherheit hat oberste Priorität. Sie sollten definitiv auf Merkmale wie eine Automatisches Brandbekämpfungssystem, Echtzeit-Gas- und Temperaturüberwachung, achten, sowie auf einen Not-Aus-Schalter. Das Prüfinstrument von Derui umfasst all diese Funktionen, plus Sicherheitsverriegelungen am Zündsystem, was eine wichtige Funktion ist, um einen versehentlichen Betrieb zu verhindern.

4. F: Entspricht Deruis Feuerprüfer den UL 9540A-Standards?
A: Ja, absolut. Derui EV-Batteriezellfeuerprüfer ist speziell dafür ausgelegt, Tests gemäß den UL 9540A, zusammen mit anderen wichtigen Standards wie ASTM E3189 und GB/T 31485. Dies macht es zu einer soliden Wahl für jeden, der seine Batteriezellen oder -systeme für den Markt zertifizieren lassen möchte.

5. F: Kann ich mit einer Maschine verschiedene Größen von Batteriezellen testen?
A: Gute Frage! Viele Tester haben feste Kammern, aber das Derui-Modell verwendet ein modulares Kammerdesign. Das bedeutet, dass Sie die Einrichtung anpassen oder neu konfigurieren können, um verschiedene Batteriezellgrößen und -formate zu berücksichtigen, von kleinen zylindrischen Zellen bis hin zu größeren Beuteln, was eine große Flexibilität für ein F&E-Labor bietet.

6. F: Welche Art von Daten sammelt der Derui-Batterieflammentester?
A: Er sammelt umfassende, hochauflösende Daten, die für die Analyse entscheidend sind. Sie erhalten präzise Temperaturprofile von mehreren Punkten, Druckänderungen im Inneren der Kammer, und mit optionalen Erweiterungen können Sie sogar die Gasemissionen analysieren, die während der Verbrennung entstehen. Diese Daten sind entscheidend für das Verständnis von Versagensmodi.

7. F: Ist das System für neue Techniker schwer zu bedienen?
A: Aus den Produktspezifikationen geht hervor, dass sie die Benutzerfreundlichkeit priorisiert haben. Es verfügt über eine intuitive Touchscreen-Oberfläche und klare Einrichtungsanleitungen. Obwohl eine angemessene Schulung für solch spezialisierte Geräte immer erforderlich ist, sollte die Lernkurve überschaubar sein, sodass neue Techniker relativ schnell einsatzbereit sind.

8. F: Wer nutzt typischerweise dieses Gerät zur Simulation von EV-Batteriebränden?
A: Die Hauptnutzer sind Hersteller von EV-Batterien, Laboratorien für Tests durch Dritte, und Forschungseinrichtungen. Sie verwenden es für alles, von Frühphasen-F&E bis hin zu Endqualitätskontrolle und Zertifizierungstests, um sicherzustellen, dass die Batterien sicher sind, bevor sie in Autos oder Energiespeichersysteme eingebaut werden.

9. F: Welche maximale Temperatur kann die Derui-Testkammer erreichen?
A: Derui EV-Batteriezellen-Feuertester hat einen beeindruckenden Temperaturbereich und kann bis zu erreichen 1100°C (2000°F). Dies ist mehr als ausreichend, um die extremen Bedingungen eines Batteriezündens und thermischen Durchgehens zu simulieren.

10. F: Bietet Derui Installations- und Schulungsdienste an?
A: Es ist immer am besten, direkt bei ihnen nachzufragen, aber Unternehmen, die ausgefeilte Laborausrüstung wie diese verkaufen, bieten in der Regel Installation, Inbetriebnahme und Erstschulung als Teil ihres Servicepakets an. Deruis Schwerpunkt auf After-Sales-Support deutet darauf hin, dass sie dies bereitstellen würden, um sicherzustellen, dass Sie den Tester effektiv und sicher verwenden können.

11. F: Wie zuverlässig ist die Batterietesttechnik von Derui?
A: Basierend auf ihrer Marketingstrategie und Branchenpräsenz scheint Derui einen starken Ruf für Zuverlässigkeit zu haben. Sie heben ihre bewährte Erfolgsbilanz und die Verwendung langlebiger Materialien wie Edelstahl hervor. Für eine endgültige Antwort wäre es ratsam, sie nach Kundenreferenzen oder Fallstudien von bestehenden Kunden in Deutschland zu fragen.

12. F: Kann dieser Tester für Energiespeichersystem- (ESS) Batteriemodule verwendet werden?
A: Während dieses spezielle Modell für einzelne Zellen, entwickelt wurde, sind die zugrunde liegende Technologie und Sicherheitsprinzipien die gleichen. Für das Testen größerer ESS Module, Sie müssten bei Derui nach einer größeren, maßgeschneiderten Kammer oder einem anderen Modell in ihrer Produktlinie fragen, das für Modul-Tests ausgelegt ist.

13. F: Wie lange ist die Lieferzeit nach Bestellung eines Derui-Feuertesters?
A: Lieferzeiten können je nach Bestellmenge und Anpassungen variieren. Für eine Standardeinheit sind es möglicherweise einige Monate, bei einem maßgeschneiderten System könnte es länger dauern. Der beste Weg, eine zuverlässige Lieferzeit zu erhalten, ist direkt ein Angebot vom Vertriebsteam von Derui anzufordern, da sie Ihnen eine aktuelle Zeitplanung geben können.

14. F: Gibt es Finanzierungsoptionen für diese Geräte?
A: Ja, Derui erwähnt, dass sie flexible Finanzierungspläne, einschließlich monatlicher Ratenzahlungen und Leasingoptionen, anbieten. Dies ist bei hochpreisiger Kapitalausstattung ziemlich üblich und kann es Start-ups oder kleineren Labors erleichtern, die notwendige Testtechnologie zu erwerben.

15. F: Warum sollte ich Derui gegenüber anderen Marken von Batteriefeuertestern wählen?
A: Soweit ich es beurteilen kann, scheinen die wichtigsten Vorteile von Derui ihre Fokus auf den deutschen Markt und seine Standards, die modulares und flexibles Design ihrer Kammer sowie ihre Betonung auf starken After-Sales-Support. zu sein. Wenn Sie einen Partner schätzen, der Anpassungen und zuverlässigen Langzeitservice bieten kann, sind sie definitiv einen genaueren Blick wert im Vergleich zu anderen Marken.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
NachrichtNachricht

Anfrage für ein Angebot