Étage 1, No. 3, Avenue Shugang, Ville de Hongmei, Dongguan, Province du Guangdong, Chine

Fabricant de chambres d'essai environnemental depuis 20 ansPlus de 3000 livraisons clients dans le monde entier    Email : shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Système de test de cellules de batterie électrique

Le DERUI DR-D213 power battery cell testing system supports programmable cell charge–discharge, pulse and DCIR workflows. Select the current variant, channels, fixtures and data interfaces around your cell and approved test recipe.

Modèle DR-D213
Cell Voltage Published 0.8–5 V per channel
Current Variants 30 / 60 / 100 / 150 / 300 A; confirm ordered variant
Précision Published voltage/current ±0.02% F.S.; verify conditions
Recording Published 10 ms interval; Excel / TXT export
Before Quotation Confirm channel count, fixtures, recipe, software, site power and FAT
Sûr et fiable
bien fabriqué
Assurance qualité
personnalisation
MessageWhatsApp
Numéro de hotline 15580327593
  • Détails du produit
  • Paramètres techniques
  • FAQ
  • Contactez-nous
CELL CHARGE–DISCHARGE & PERFORMANCE TESTING

DR-D213 Power Battery Cell Testing System

Run programmable charge–discharge, pulse and DCIR workflows on battery cells with a configuration selected for the cell, current, channel count and facility. Use the published DR-D213 electrical specification as the starting point, then verify the ordered cabinet, fixtures and software in the technical agreement.

Important distinction: this is an electrical cell-test system. It does not by itself provide a temperature chamber, mechanical abuse rig or certification of a finished battery.
Single-channel voltage0.8–5 V published
Current variants30 / 60 / 100 / 150 / 300 A published
Voltage / current accuracy±0.02% F.S. published
Data interval10 ms published

Start with the Cell and the Test Profile

A useful proposal begins with the cell's voltage window, maximum charge and discharge current, connector design, heat output and required test sequence. Those inputs determine the channel rating, fixture, cabinet quantity and how results will be recorded. DR-D213 is relevant to R&D, cell screening and cycle-performance workflows when the selected configuration matches those inputs.

Performance cycling

Define CC, CV, CCCV, CP or CR steps, end conditions, rest periods and repeat count.

Pulse and DCIR

Provide pulse width, current, SOC points, rest time and the DCIR calculation method.

Production data

Specify channels, traceability fields, export format, uptime and MES requirements before quoting.

Published DR-D213 Electrical Baseline

Paramètre Published DR-D213 value Confirm in purchase specification
AC supply 380 ±10% VAC, 50 ±5% Hz; three-phase five-wire Site supply, breaker, earthing and total cabinet input
DC voltage and current 0.8–5 V per channel; 30 / 60 / 100 / 150 / 300 A variants Selected current rating, channel count and parallel operation
Measurement Voltage and current accuracy ±0.02% F.S.; voltage resolution 0.1 mV; current resolution 0.1 mA Range, calibration method, temperature and measurement points
Dynamic response Current response 5 ms (10–90% F.S.); switching 10 ms (−90 to 90% F.S.) Applicable load, method and waveform record
Logging 10 ms recording interval; Excel / TXT export Actual fields, timestamps, retention and export sample
Power feedback Published maximum feedback efficiency ≥75%; power factor >0.99; THD <5% Operating point, grid conditions and witnessed measurement
Environment IP20; 0–40°C working temperature; forced-fan cooling; noise <75 dB Room ventilation, clearances and measurement conditions
Do not carry over the old promotional table: its 0–10 V, 1000 A+, 96–512+ channels and “80%+ energy savings” are not substantiated by the DR-D213 technical parameter tab. Quoted systems may vary; request a model-specific drawing and signed specification.

Workflow and Data: What Is Published, What Needs a Demo

Program the recipe

Published charge modes include CC, CV, CCCV and CP; discharge modes include CC, CV, CP and CR. The page also lists pulse and DCIR workflows.

Protect the test

Published software protections cover over-current, over-voltage, under-voltage, reverse/wrong connection and abnormal communication. Request a fault-response demonstration.

Review the record

Check actual 10 ms data files, timestamps, channel ID, alarms, power interruption behavior and export into your analysis process.

The published software specification lists up to 10,000 editable/program steps and 10 nested-loop layers. These are configuration limits to verify in a live software demonstration, not a promise that every requested test sequence is supported without review.

Select the System Without Mixing It with Other Battery Equipment

Exigence DR-D213 role Separate or project-specific scope
Cell cycling, capacity, pulse, DCIR Electrical source/sink and measurement channels Cell fixture, channel rating, method and software configuration
Temperature-conditioned cycling Published support for linkage with a temperature chamber External chamber, communication protocol, interlocks and profile validation
Mechanical, flame or thermal-abuse tests Not provided by the electrical cycler itself Dedicated abuse equipment and site risk controls
UN 38.3 or product certification May supply electrical data for an applicable program Exact test methods, approved laboratory and complete evidence package

For climatic exposure, review the battery test chamber range as a separate equipment decision.

Acceptance Evidence for Engineering and Procurement

Channel proof

Verify the ordered channel count and current/voltage variant on cabinet labels and wiring diagrams.

Accuracy proof

Agree calibrated instrument, operating points, load and acceptance limits for voltage/current checks.

Workflow proof

Witness charge, discharge, pulse, DCIR, safety trip, interruption recovery and file export.

Ask for real evidence: proposed cabinet photos, fixture drawings, a representative data export, calibration material and a signed FAT checklist. Do not use unapproved customer logos or case-study percentages.

Foire Aux Questions

What current range does DR-D213 offer?

The published technical table lists 30, 60, 100, 150 and 300 A variants. Confirm the selected variant and its channel count in the quotation.

Is 1000 A standard?

The current DR-D213 technical table does not substantiate a 1000 A variant. Ask DERUI for a separate documented design if that current is required.

Does it include a climatic chamber?

No chamber is established as part of the base electrical system. The published specification mentions linkage with external temperature equipment; confirm hardware and protocol for the project.

Is EIS included?

The legacy marketing copy calls it optional, while the DR-D213 technical parameter table does not specify an EIS module. Treat it as unconfirmed until documented.

Does the equipment itself have UL or UN 38.3 certification?

The present product record does not provide model-specific certificates supporting those claims. Request relevant documents; specimen compliance requires the complete applicable test program.

Request a Cell-Matched DR-D213 Configuration

Send the electrical limits and one representative test recipe. Ask for a channel/cabinet layout, fixture drawing, software demo and measurable FAT plan before approving the proposal.

Request a DR-D213 review

Include with your inquiry

  • Cell format and voltage window
  • Charge/discharge current and channels
  • Pulse/DCIR or cycling recipe
  • Site power, cooling and data interfaces
FacebookLinkedInXRedditWhatsApp

Published DR-D213 baseline. The ordered current variant, channel quantity, accuracy conditions, fixtures and software interfaces require a signed technical agreement.

Article Published specification / confirmation
Modèle DR-D213
AC wiring / supply Three-phase five-wire; 380 ±10% VAC; 50 ±5% Hz
Power factor / THD >0.99 / <5% (published; test conditions to confirm)
Maximum feedback efficiency ≥75% (published; operating point to confirm)
Single-channel voltage 0.8–5 V
Output-current variants 30 / 60 / 100 / 150 / 300 A; ordered variant and channel count to confirm
Voltage accuracy / resolution ±0.02% F.S. / 0.1 mV
Current accuracy / resolution ±0.02% F.S. / 0.1 mA
Current response / switching 5 ms (10–90% F.S.) / 10 ms (−90 to 90% F.S.)
Intervalle d'enregistrement des données 10 ms; Excel / TXT export
Charge / discharge modes CC, CV, CCCV, CP / CC, CV, CP, CR
Other modes Rest, pause, condition simulation, pulse, DCIR
Program capacity Up to 10,000 steps and 10 nested-loop layers, as published
Protection logicielle OCP, OVP, UVP, reverse/wrong connection and abnormal-communication protection
External linkage Temperature chamber, MTV/MTS and pressure sensor listed; interface details to confirm
Environment / cooling IP20, 0–40°C, forced-fan cooling
Noise / cabinet dimensions <75 dB; 600 × 850 × 1030 or 600 × 800 × 1980 mm (W × D × H), by configuration

1. Qu'est-ce qu'un système de test de cellules de batterie haute puissance ?
Un système de test de cellules de batterie haute puissance est un équipement spécialisé utilisé pour évaluer la performance, la longévité et la sécurité des cellules de batterie individuelles. Il effectue des tests critiques tels que la durée de vie en cycle, la capacité, l'efficacité et la résistance interne, fournissant des données essentielles pour la R&D et le contrôle qualité dans des industries comme les véhicules électriques et le stockage d'énergie.

2. Combien coûte un système de test de cellules de batterie haute puissance ?
Le coût varie considérablement en fonction du nombre de canaux, des plages de courant/tension, et des fonctionnalités comme la rétroaction d'énergie. Les systèmes d'entrée de gamme peuvent commencer dans les dizaines de milliers d'euros, tandis que les systèmes à nombreux canaux, haute puissance et entièrement automatisés peuvent atteindre plusieurs centaines de milliers d'euros. Il est préférable de demander un devis personnalisé en fonction de vos besoins spécifiques en test.

3. Quel est l'avantage d'un système de rétroaction d'énergie (régénératif) ?
Un système de rétroaction d'énergie récupère et réutilise plus de 80 % de l'énergie dissipée lors des tests de cycle de charge-décharge vers le réseau électrique. Cela réduit considérablement les coûts d'électricité et la génération de chaleur, conduisant à un retour sur investissement plus rapide et à des dépenses opérationnelles moindres, en particulier pour les laboratoires de test à volume élevé.

4. Le système de test peut-il gérer différents types de cellules de batterie comme prismatic, cylindrique et pouch ?
Oui, un système de test de cellules de batterie haute qualité est conçu pour être indépendant de la forme des cellules. Avec les dispositifs et configurations de canaux appropriés, il peut tester tous les types de cellules courants, y compris les cylindriques 18650, 21700, 4680, ainsi que les cellules prismatic et pouch de grande taille.

5. Quel logiciel est inclus avec le système de test, et quelles sont ses capacités ?
Ces systèmes sont généralement livrés avec un logiciel propriétaire (par exemple, BATTEST® de Derui). Les principales fonctionnalités incluent l'édition illimitée des étapes de test, la représentation graphique et la journalisation des données en temps réel, le contrôle parallèle des canaux, et des options avancées d'exportation de données (vers Excel, SQL, etc.) pour une analyse approfondie et des rapports.

6. Tous les canaux fonctionnent-ils indépendamment ?
Oui, dans un système de test moderne, chaque canal fonctionne indépendamment. Cela vous permet d'exécuter différents profils de test sur différents canaux simultanément, de mettre en pause des canaux individuels, et de gérer un mélange de types de cellules ou de niveaux de SoC (État de Charge) sans interrompre les autres tests, maximisant ainsi l'efficacité du laboratoire.

7. Quelles certifications doit avoir un système de test de cellules de batterie fiable ?
Recherchez des systèmes conformes aux normes internationales de sécurité et de qualité. Les certifications clés incluent UL et CE pour la sécurité électrique, ISO 9001 pour la gestion de la qualité, et des normes spécifiques telles que UN38.3 pour la conformité des tests de batteries lithium-ion.

8. Quelle est la précision et la stabilité du contrôle de la tension et du courant ?
Pour les tests de batteries électriques, une précision élevée est essentielle. Les systèmes de premier ordre offrent une précision meilleure que ±0,05% de la pleine échelle (FS) et une ondulation de courant inférieure à 0,05% FS. Cela garantit que vos résultats de test sont fiables, reproductibles et capables de détecter de subtiles différences de performance entre les cellules.

9. Le système peut-il s'intégrer avec des chambres environnementales ?
Absolument. La plupart des systèmes offrent des options d'interface (souvent via CAN ou Ethernet) pour se synchroniser avec des chambres environnementales externes. Cela vous permet d'effectuer des tests de cycle de température, simulant des conditions réelles allant de sub-zero à des températures élevées pour valider la performance de la batterie sous stress.

10. Quelles fonctionnalités de sécurité sont intégrées au système ?
Au-delà des protections électriques standard (surtension, surintensité, court-circuit), les systèmes avancés incluent des alarmes basées sur logiciel, une alerte précoce de thermal runaway utilisant l'analyse dV/dt et dT/dt, et une intégration transparente avec les systèmes de sécurité de l'installation pour protéger à la fois l'équipement et les opérateurs.

11. Quel est le délai de livraison et d'installation typique ?
Les délais peuvent varier de 8 à 16 semaines après la confirmation de commande, en fonction de la complexité et de la personnalisation du système. Cela inclut la fabrication, les tests d'acceptation en usine, et la coordination pour l'installation sur site et la formation par des ingénieurs spécialisés.

12. Quel type de support et de garantie est fourni ?
Les fabricants réputés offrent une garantie complète (par exemple, 24 mois) et un support continu. Cela inclut souvent un diagnostic à distance, des mises à jour logicielles OTA, un réseau mondial de pièces de rechange, et des services optionnels d'installation et de formation sur site pour assurer le bon fonctionnement de votre système.

 
 
 
 
 
 
 
 
 
 
WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MessageMessage

Demandez un devis