Calle Shugang 1, No. 3, Town de Hongmei, Ciudad de Dongguan, Provincia de Guangdong, China

Fabricante de cámaras de prueba ambiental con 20 años de experienciaMás de 3000 entregas a clientes en todo el mundo           Correo electrónico: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Sistema de prueba de celdas de batería de energía

La DERUI DR-D213 power battery cell testing system supports programmable cell charge–discharge, pulse and DCIR workflows. Select the current variant, channels, fixtures and data interfaces around your cell and approved test recipe.

Modelo DR-D213
Cell Voltage Published 0.8–5 V per channel
Current Variants 30 / 60 / 100 / 150 / 300 A; confirm ordered variant
Precisión Published voltage/current ±0.02% F.S.; verify conditions
Recording Published 10 ms interval; Excel / TXT export
Before Quotation Confirm channel count, fixtures, recipe, software, site power and FAT
Segura y confiable
bien hecha
Garantía de calidad
personalización
MensajeWhatsApp
Número de línea directa 15580327593
  • Detalles del producto
  • Parámetros técnicos
  • Preguntas frecuentes
  • Contáctanos
CELL CHARGE–DISCHARGE & PERFORMANCE TESTING

DR-D213 Power Battery Cell Testing System

Run programmable charge–discharge, pulse and DCIR workflows on battery cells with a configuration selected for the cell, current, channel count and facility. Use the published DR-D213 electrical specification as the starting point, then verify the ordered cabinet, fixtures and software in the technical agreement.

Important distinction: this is an electrical cell-test system. It does not by itself provide a temperature chamber, mechanical abuse rig or certification of a finished battery.
Single-channel voltage0.8–5 V published
Current variants30 / 60 / 100 / 150 / 300 A published
Voltage / current accuracy±0.02% F.S. published
Data interval10 ms published

Start with the Cell and the Test Profile

A useful proposal begins with the cell's voltage window, maximum charge and discharge current, connector design, heat output and required test sequence. Those inputs determine the channel rating, fixture, cabinet quantity and how results will be recorded. DR-D213 is relevant to R&D, cell screening and cycle-performance workflows when the selected configuration matches those inputs.

Performance cycling

Define CC, CV, CCCV, CP or CR steps, end conditions, rest periods and repeat count.

Pulse and DCIR

Provide pulse width, current, SOC points, rest time and the DCIR calculation method.

Production data

Specify channels, traceability fields, export format, uptime and MES requirements before quoting.

Published DR-D213 Electrical Baseline

Parámetro Published DR-D213 value Confirm in purchase specification
AC supply 380 ±10% VAC, 50 ±5% Hz; three-phase five-wire Site supply, breaker, earthing and total cabinet input
DC voltage and current 0.8–5 V per channel; 30 / 60 / 100 / 150 / 300 A variants Selected current rating, channel count and parallel operation
Measurement Voltage and current accuracy ±0.02% F.S.; voltage resolution 0.1 mV; current resolution 0.1 mA Range, calibration method, temperature and measurement points
Dynamic response Current response 5 ms (10–90% F.S.); switching 10 ms (−90 to 90% F.S.) Applicable load, method and waveform record
Logging 10 ms recording interval; Excel / TXT export Actual fields, timestamps, retention and export sample
Power feedback Published maximum feedback efficiency ≥75%; power factor >0.99; THD <5% Operating point, grid conditions and witnessed measurement
Environment IP20; 0–40°C working temperature; forced-fan cooling; noise <75 dB Room ventilation, clearances and measurement conditions
Do not carry over the old promotional table: its 0–10 V, 1000 A+, 96–512+ channels and “80%+ energy savings” are not substantiated by the DR-D213 technical parameter tab. Quoted systems may vary; request a model-specific drawing and signed specification.

Workflow and Data: What Is Published, What Needs a Demo

Program the recipe

Published charge modes include CC, CV, CCCV and CP; discharge modes include CC, CV, CP and CR. The page also lists pulse and DCIR workflows.

Protect the test

Published software protections cover over-current, over-voltage, under-voltage, reverse/wrong connection and abnormal communication. Request a fault-response demonstration.

Review the record

Check actual 10 ms data files, timestamps, channel ID, alarms, power interruption behavior and export into your analysis process.

The published software specification lists up to 10,000 editable/program steps and 10 nested-loop layers. These are configuration limits to verify in a live software demonstration, not a promise that every requested test sequence is supported without review.

Select the System Without Mixing It with Other Battery Equipment

Requisito DR-D213 role Separate or project-specific scope
Cell cycling, capacity, pulse, DCIR Electrical source/sink and measurement channels Cell fixture, channel rating, method and software configuration
Temperature-conditioned cycling Published support for linkage with a temperature chamber External chamber, communication protocol, interlocks and profile validation
Mechanical, flame or thermal-abuse tests Not provided by the electrical cycler itself Dedicated abuse equipment and site risk controls
UN 38.3 or product certification May supply electrical data for an applicable program Exact test methods, approved laboratory and complete evidence package

For climatic exposure, review the cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits as a separate equipment decision.

Acceptance Evidence for Engineering and Procurement

Channel proof

Verify the ordered channel count and current/voltage variant on cabinet labels and wiring diagrams.

Accuracy proof

Agree calibrated instrument, operating points, load and acceptance limits for voltage/current checks.

Workflow proof

Witness charge, discharge, pulse, DCIR, safety trip, interruption recovery and file export.

Ask for real evidence: proposed cabinet photos, fixture drawings, a representative data export, calibration material and a signed FAT checklist. Do not use unapproved customer logos or case-study percentages.

Preguntas Frecuentes

What current range does DR-D213 offer?

The published technical table lists 30, 60, 100, 150 and 300 A variants. Confirm the selected variant and its channel count in the quotation.

Is 1000 A standard?

The current DR-D213 technical table does not substantiate a 1000 A variant. Ask DERUI for a separate documented design if that current is required.

Does it include a climatic chamber?

No chamber is established as part of the base electrical system. The published specification mentions linkage with external temperature equipment; confirm hardware and protocol for the project.

Is EIS included?

The legacy marketing copy calls it optional, while the DR-D213 technical parameter table does not specify an EIS module. Treat it as unconfirmed until documented.

Does the equipment itself have UL or UN 38.3 certification?

The present product record does not provide model-specific certificates supporting those claims. Request relevant documents; specimen compliance requires the complete applicable test program.

Request a Cell-Matched DR-D213 Configuration

Send the electrical limits and one representative test recipe. Ask for a channel/cabinet layout, fixture drawing, software demo and measurable FAT plan before approving the proposal.

Request a DR-D213 review

Include with your inquiry

  • Cell format and voltage window
  • Charge/discharge current and channels
  • Pulse/DCIR or cycling recipe
  • Site power, cooling and data interfaces
FacebookLinkedInXRedditWhatsApp

Published DR-D213 baseline. The ordered current variant, channel quantity, accuracy conditions, fixtures and software interfaces require a signed technical agreement.

Artículo Published specification / confirmation
Modelo DR-D213
AC wiring / supply Three-phase five-wire; 380 ±10% VAC; 50 ±5% Hz
Power factor / THD >0.99 / <5% (published; test conditions to confirm)
Maximum feedback efficiency ≥75% (published; operating point to confirm)
Single-channel voltage 0.8–5 V
Output-current variants 30 / 60 / 100 / 150 / 300 A; ordered variant and channel count to confirm
Voltage accuracy / resolution ±0.02% F.S. / 0.1 mV
Current accuracy / resolution ±0.02% F.S. / 0.1 mA
Current response / switching 5 ms (10–90% F.S.) / 10 ms (−90 to 90% F.S.)
Intervalo de registro de datos 10 ms; Excel / TXT export
Charge / discharge modes CC, CV, CCCV, CP / CC, CV, CP, CR
Other modes Rest, pause, condition simulation, pulse, DCIR
Program capacity Up to 10,000 steps and 10 nested-loop layers, as published
Protección de software OCP, OVP, UVP, reverse/wrong connection and abnormal-communication protection
External linkage Temperature chamber, MTV/MTS and pressure sensor listed; interface details to confirm
Environment / cooling IP20, 0–40°C, forced-fan cooling
Noise / cabinet dimensions <75 dB; 600 × 850 × 1030 or 600 × 800 × 1980 mm (W × D × H), by configuration

1. ¿Qué es un Sistema de Pruebas de Celdas de Batería de Potencia?
Un Sistema de Pruebas de Celdas de Batería de Potencia es un equipo especializado utilizado para evaluar el rendimiento, la longevidad y la seguridad de celdas de batería individuales. Realiza pruebas críticas como vida útil en ciclo, capacidad, eficiencia y resistencia interna, proporcionando datos esenciales para I+D y control de calidad en industrias como vehículos eléctricos y almacenamiento de energía.

2. ¿Cuánto cuesta un Sistema de Pruebas de Celdas de Batería de Potencia?
El costo varía significativamente según el número de canales, rangos de corriente/voltaje y funciones como retroalimentación de energía. Los sistemas de nivel básico pueden comenzar en decenas de miles de dólares, mientras que los sistemas de múltiples canales y alta potencia con automatización completa pueden alcanzar varios cientos de miles. Es recomendable solicitar una cotización personalizada según sus requisitos específicos de prueba.

3. ¿Cuál es el beneficio de un sistema de retroalimentación de energía (regenerativo)?
Un sistema de retroalimentación de energía recupera y reutiliza más del 80% de la energía disipada durante las pruebas de ciclo de carga-descarga, devolviéndola a la red. Esto reduce drásticamente los costos de electricidad y la generación de calor, llevando a un retorno de inversión más rápido y menores gastos operativos, especialmente en laboratorios de pruebas de alto volumen.

4. ¿El sistema de pruebas puede manejar diferentes tipos de celdas de batería como prismáticas, cilíndricas y pouch?
Sí, un Sistema de Pruebas de Celdas de Batería de Potencia de alta calidad está diseñado para ser independiente de la forma de las celdas. Con los accesorios y configuraciones de canales adecuados, puede probar todos los tipos comunes de celdas, incluyendo cilíndricas 18650, 21700, 4680, así como celdas prismáticas y pouch de gran formato.

5. ¿Qué software incluye el sistema de pruebas y cuáles son sus capacidades?
Estos sistemas generalmente vienen con software propietario (por ejemplo, BATTEST® de Derui). Las capacidades clave incluyen edición ilimitada de pasos de prueba, graficación y registro de datos en tiempo real, control paralelo de canales y opciones avanzadas de exportación de datos (a Excel, SQL, etc.) para análisis y reportes detallados.

6. ¿Todos los canales operan de forma independiente?
Sí, en un sistema de pruebas moderno, cada canal funciona de manera independiente. Esto permite ejecutar diferentes perfiles de prueba en distintos canales simultáneamente, pausar canales individuales y manejar una variedad de tipos de celdas o niveles de SoC (Estado de Carga) sin interrumpir otras pruebas, maximizando la eficiencia del laboratorio.

7. ¿Qué certificaciones debe tener un sistema de pruebas de celdas de batería confiable?
Busque sistemas que cumplan con estándares internacionales de seguridad y calidad. Las certificaciones clave incluyen UL y CE para seguridad eléctrica, ISO 9001 para gestión de calidad, y estándares específicos como UN38.3 para cumplimiento en pruebas de baterías de iones de litio.

8. ¿Qué tan precisa y estable es el control de voltaje y corriente?
Para pruebas de baterías de potencia, la alta precisión es fundamental. Los sistemas de primera categoría ofrecen una precisión mejor que ±0.05% del Total de Escala (FS) y una ondulación de corriente por debajo de 0.05% FS. Esto garantiza que los resultados de sus pruebas sean confiables, reproducibles y puedan detectar diferencias sutiles en el rendimiento entre celdas.

9. ¿El sistema puede integrarse con cámaras ambientales?
Por supuesto. La mayoría de los sistemas ofrecen opciones de interfaz (a menudo vía CAN o Ethernet) para sincronizarse con cámaras ambientales externas. Esto le permite realizar pruebas de ciclos de temperatura, simulando condiciones del mundo real desde temperaturas bajo cero hasta altas temperaturas para validar el rendimiento de la batería bajo estrés.

10. ¿Qué características de seguridad están integradas en el sistema?
Más allá de las protecciones eléctricas estándar (sobrevoltaje, sobrecorriente, cortocircuito), los sistemas avanzados incluyen alarmas basadas en software, advertencias tempranas de fuga térmica mediante análisis dV/dt y dT/dt, y una integración perfecta con los sistemas de seguridad de la instalación para proteger tanto el equipo como a los operadores.

11. ¿Cuál es el tiempo de entrega e instalación típico?
Los plazos de entrega pueden variar de 8 a 16 semanas después de la confirmación del pedido, dependiendo de la complejidad y personalización del sistema. Esto incluye fabricación, pruebas de aceptación en fábrica y coordinación para la instalación y capacitación en el sitio por ingenieros especializados.

12. ¿Qué tipo de soporte y garantía se ofrece?
Los fabricantes de buena reputación ofrecen una garantía integral (por ejemplo, 24 meses) y soporte continuo. Esto suele incluir diagnósticos remotos, actualizaciones de software por aire (OTA), una red global de piezas de repuesto y servicios opcionales de instalación y capacitación en el sitio para garantizar que su sistema funcione sin problemas.

 
 
 
 
 
 
 
 
 
 