Étage 1, No. 3, Avenue Shugang, Ville de Hongmei, Dongguan, Province du Guangdong, Chine

Fabricant de chambres d'essai environnemental depuis 20 ansPlus de 3000 livraisons clients dans le monde entier    Email : shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Chambre d'Essai de Brûlage de Batterie

Le DERUI DR-D207 battery burning test chamber uses a Bunsen burner, stainless specimen screen and removable octagonal mesh cover for specified cell or small-battery flame-exposure procedures. Confirm the exact test clause and fixture drawing before ordering.

Modèle DR-D207
Objectif du test Controlled flame exposure with mesh surround; method-specific observation
Burner / Screen 10 mm burner mouth; 0.43 mm stainless wire, 20 openings per inch
Octagonal Cover 610 mm across opposite faces × 305 mm high; removable panels
Inner Size 750 × 750 × 500 mm (W × D × H)
Before Quotation Confirm clause/edition, cell energy and format, gas/exhaust, safety scope and FAT
Sûr et fiable
bien fabriqué
Assurance qualité
personnalisation
MessageWhatsApp
Numéro de hotline 15580327593
  • Détails du produit
  • Paramètres techniques
  • FAQ
  • Contactez-nous
CELL FLAME EXPOSURE & PROJECTILE-CONTAINMENT SETUP

DR-D207 Battery Burning Test Chamber

A purpose-built burner, specimen screen and removable octagonal mesh cover for controlled flame-exposure testing of approved lithium cells or small batteries. Specify the adopted method, specimen and laboratory safety plan before treating any fixture geometry as a compliance claim.

What this equipment is: a flame-exposure fixture. It is not a programmable temperature chamber, a full-size pack fire tester or a UN 38.3 transport-test system.
ModèleDR-D207
Burner10 mm internal tube opening; approximately 100 mm long
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits0.43 mm stainless wire; 20 openings per inch
Internal enclosure750 × 750 × 500 mm (W × D × H)

What the Test Helps You Observe

During a specified flame-exposure procedure, a cell or approved small battery sits above the burner while the screen and octagonal surround define the setup and help retain ejected material. The laboratory observes the behavior required by its adopted method; pass/fail criteria must come from that method and the test plan, not from the chamber specification alone.

Controlled setup

Published burner, screen, opening and octagonal-cover dimensions provide a starting point for method review.

Visible evidence

Agree in advance how the operator will record exposure time, specimen behavior and any ejected material.

Safer procurement

Confirm fuel supply, exhaust, operator protection and post-test handling before ordering.

Published DR-D207 Configuration

Article Published value cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Control and timer Button control; flame-time setting shown as 0–99H99M Confirm actual timer input format, resolution and shutoff behavior.
Burner and opening Bunsen burner, 10 mm internal mouth, approximately 100 mm length; test opening 100 ± 2 mm Confirm burner type, flame setting and fixture drawing against the adopted standard edition.
Specimen screen 0.43 mm stainless woven wire; 20 openings per inch Confirm mounting height and replacement screen supplied.
Octagonal cover 610 mm across opposite faces; 305 mm high; eight removable panels; 0.25 mm aluminum wire, 16–18 openings per inch Request dimensional drawing and panel-retention details.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 750 × 750 × 500 mm internal; 1000 × 950 × 1310 mm external, including door lock Confirm usable clearance around the fixture and doorway.
Utilités Methane or LPG supplied by customer; 220 V, 50/60 Hz, 200 W; approximately 160 kg Confirm gas regulation, ventilation, site power and nameplate.
Relief and exhaust 200 × 200 mm pressure-relief door; rear Ø100 mm exhaust connection; door-retention chain Confirm discharge direction, duct requirements and risk-assessed containment limits.
Dimension requiring a drawing: the old specification states “height of the flame from the screen: 38 mm.” That wording does not unambiguously define the burner-to-screen geometry; verify it on the approved setup drawing.

Method Fit: Review the Clause, Not a Logo List

The DR-D207 screen and octagonal-surround geometry warrants review against the UL 1642 Projectile Test, but published fixture similarity is not proof of conformance. In particular, the DR-D207 page specifies a Bunsen burner, while a published technical comparison describes a Meker-type burner for the UL 1642 fire-exposure setup. Verify the adopted edition, burner, all dimensions, specimen preparation, observation and acceptance rules clause by clause before any UL 1642 claim.

Do not treat this chamber as a UN 38.3 test method. The UN transport manual has defined T.1–T.8 tests; a generic “UN 38.3 T.10 burning test” claim should not appear on this page. Other standards such as UL 2054 or IEC 62133-2 may form part of a laboratory program but do not automatically validate this fixture.

Send the exact method

Standard edition, clause, cell format, sample state, exposure period and pass/fail rule.

Confirm the physical setup

Burner specification, mesh, opening, screen-to-burner position and octagonal-cover drawing.

Confirm evidence

Video/observation plan, timed exposure, calibration records and final report format.

DR-D207 Is Different from DERUI's Other Battery Fire Equipment

Equipment Primary function Do not assume
DR-D207 burning test chamber Burner, screen and octagonal mesh fixture for specified cell/small-battery flame exposure Large pack fire testing, programmable heating or certified blast containment
DR-D211 EV battery cell fire tester A different external-flame test setup; compare its published specimen and burner limits separately Interchangeability with the DR-D207 projectile-test geometry
Battery thermal abuse chamber Controlled high-temperature exposure in a heated enclosure An open-flame burner or octagonal-mesh projectile-test fixture

Site Safety and Acceptance Plan

Review the specimen

Provide chemistry, dimensions, maximum energy, charge state and credible venting behavior. Agree allowable specimen size and quantity.

Review the facility

Confirm methane/LPG supply, regulator, exhaust route, clearance, fire response and operator exclusion area with site EHS.

Witness the setup

Check burner, screen and cover dimensions, timer, gas shutoff behavior, exhaust, door and documentation during FAT.

Safety boundary: the published relief door and retention chain are construction features, not evidence of a rated explosion-proof or thermal-runaway containment system. Gas detection, suppression, data export and interlocks are not established as standard features by the current public specification.

Questions Buyers Ask

Is this a UL-certified chamber?

No certification evidence is established by the public product page. Review fixture suitability against the exact UL 1642 edition and obtain any required third-party evaluation separately.

Can it test EV modules or packs?

Do not infer that from the enclosure size. Obtain a specimen-size, energy and hazard assessment, then compare the appropriate larger-scale equipment.

Is the gas included?

The published specification says methane or LPG is customer-provided. Confirm regulator, hose, shutoff and local installation scope in the quotation.

Does it perform UN 38.3 transport testing?

No. This burner arrangement should not be presented as a UN 38.3 test. Choose the dedicated equipment for the required T.1–T.8 method.

What needs confirmation before publication or purchase?

The adopted standard edition, fixture drawing, timer format, safety controls, real-device photos, accessories and measurable FAT criteria.

Request a Method-Matched DR-D207 Proposal

Send your cell drawing and test clause. DERUI can respond with the fixture drawing, included scope, utility list and an acceptance checklist that engineering and purchasing can review together.

Discuss the DR-D207 setup

Include in the inquiry

  • Standard edition and exact clause
  • Cell/battery format and energy
  • Gas and exhaust conditions
  • Required observation and FAT records
FacebookLinkedInXRedditWhatsApp

DR-D207 values below come from the current DERUI product record. Confirm the approved drawing and safety configuration before ordering.

Article Published configuration / verification point
Model / control DR-D207; button control
Burner Bunsen burner; 10 mm internal tube-mouth diameter; approximately 100 mm tube length
Flame-time setting Published as 0–99H99M; confirm valid timer input format, resolution and shutoff logic
Test opening 100 ± 2 mm diameter
Specimen screen Stainless woven wire, 0.43 mm diameter; 20 openings per inch
Burner/screen geometry Published “38 mm” wording is ambiguous; require approved dimensioned drawing
Octagonal mesh cover 610 mm across opposite faces; 305 mm high; eight removable faces; 0.25 mm aluminum wire, 16–18 openings per inch
Fuel Methane or LPG; customer-provided. Confirm regulator, supply and shutoff requirements
Inner / outer dimensions 750 × 750 × 500 mm / 1000 × 950 × 1310 mm (W × D × H; outer includes door lock)
Relief / exhaust / door 200 × 200 mm relief door; rear Ø100 mm exhaust connection; left-opening door with retention chain. No rated containment claim established
Supply / weight 220 V single phase, 50/60 Hz, 200 W; approximately 160 kg

1. Qu'est-ce qu'une chambre d'essai de combustion de batteries ?
Une chambre d'essai de combustion de batteries est une enceinte spécialisée, fortement renforcée, conçue pour contenir et étudier en toute sécurité les incendies de batteries. Elle permet aux chercheurs d'induire intentionnellement une défaillance thermique dans les cellules lithium-ion, en observant la propagation des flammes, les profils de température et l'efficacité de confinement dans des conditions contrôlées et reproductibles.

2. Quelles normes de sécurité peuvent être respectées avec une chambre d'essai de combustion de batteries ?
Ces chambres sont conçues pour aider les fabricants à se conformer aux normes de sécurité internationales critiques. Les principales incluent UL 9540A pour les systèmes de stockage d'énergie, UN 38.3 pour le transport des batteries lithium, ECE R100 pour les véhicules électriques, et GB/T 31485 pour les exigences de sécurité des batteries de véhicules électriques en France.

3. Quelles sont les caractéristiques de sécurité essentielles à rechercher ?
Prioriser les chambres avec systèmes de suppression automatique d'incendie (comme les sprinkleurs ou le gaz inerte), construction résistante aux explosions, surveillance en temps réel du gaz et de la température, et commutateurs d'arrêt d'urgence. Ces caractéristiques sont cruciales pour protéger votre laboratoire et le personnel lors d'une combustion contrôlée.

4. Quelle est la température maximale que ces chambres peuvent supporter ?
Les chambres de test de combustion de batteries de haute qualité sont conçues pour résister à la chaleur extrême d'un incendie de batterie. Recherchez des modèles avec une température de fonctionnement maximale d'au moins 1100°C (2000°F) pour garantir qu'elles peuvent contenir les événements de thermal runaway les plus graves sans dommage.

5. La même chambre peut-elle tester différentes tailles et types de batteries ?
Oui, de nombreuses chambres modernes disposent d'une conception modulaire. Cela permet une reconfiguration interne ou l'utilisation de différents dispositifs pour tester en toute sécurité tout, des petites cellules électroniques grand public aux modules de batteries EV ou ESS (Système de stockage d'énergie) de grande taille.

6. Quel type de données la chambre collecte-t-elle pendant un test ?
Les chambres avancées sont équipées de systèmes d'acquisition de données intégrés qui capturent des données de température à haute vitesse de plusieurs thermocouples, des variations de pression, et avec des modules optionnels, l'analyse de la composition des gaz du gaz de combustion produit lors de la combustion.

7. Comment la chambre est-elle nettoyée et entretenue après un essai au feu ?
Le nettoyage après l'essai consiste à éliminer les résidus d'incendie et à inspecter les composants. Les chambres avec intérieurs lisses en acier inoxydable, plateaux à débris amovibles, et ensembles de hublots accessibles simplifient considérablement ce processus et garantissent la préparation pour le prochain essai.

8. La chambre peut-elle être intégrée à d'autres équipements d'essai ?
Absolument. Recherchez les modèles dotés de ports de communication standard (Ethernet, CAN) qui leur permettent de se synchroniser avec des enceintes climatiques pour le préconditionnement de la température ou avec le système de gestion des données central de votre laboratoire pour la production de rapports consolidés.

11. Quel est le délai de livraison et d'installation typique ?
En raison de leur nature personnalisée et robuste, les délais de livraison d'une chambre d'essai de combustion de batterie peuvent varier de 12 à 20 semaines. Cela comprend la fabrication, la validation de la sécurité et la coordination pour l'installation professionnelle sur site et la formation des opérateurs.

10. La chambre est-elle utilisée pour le contrôle de la qualité ou uniquement pour la R&D ?
Elle remplit les deux fonctions. En R&D, les ingénieurs l'utilisent pour valider de nouvelles conceptions de cellules et de nouveaux matériaux. En Contrôle qualité, elle est utilisée pour l'échantillonnage par lots et les essais de certification afin de garantir que les cellules de production respectent les réglementations de sécurité obligatoires avant l'expédition.

11. Quel type de ventilation ou de préparation des installations est requis ?
Ces chambres nécessitent un système de ventilation d'extraction puissant et dédié.

pour éliminer en toute sécurité les fumées toxiques et la fumée après un test. Il est essentiel de consulter le fabricant dès le début pour comprendre les exigences spécifiques en matière d'alimentation électrique, d'espace et de ventilation de votre installation.
12. Quel support et quelle garantie accompagnent la chambre ? Les fabricants réputés offrent une garantie solide (par exemple, 24 mois sur les pièces et la main-d'œuvre) et un support complet. Cela doit inclure, l'installation sur site, la formation des opérateurs, le diagnostic à distance , ainsi qu'un accès à un réseau mondial de pièces de rechange.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MessageMessage

Demandez un devis