Testeur de court-circuit interne forcé de la batterie avec contrôle de force et de température de précision

Le DERUI DR-D210 battery forced internal short circuit tester combines controlled mechanical force, temperature conditioning and synchronized cell-response monitoring. Its fixture and test sequence must be matched to the cell format and exact adopted procedure.

Modèle DR-D210
Plage de force Published 0–2,000 N; force programme to confirm
Plage de température Published 0°C to +100°C
Monitoring Force, voltage and temperature; channel and export scope to confirm
Cell Scope Fixture selected for the exact cylindrical or prismatic cell and method
Method Boundary Forced internal short circuit differs from UN 38.3 T.5 external short circuit
Sûr et fiable
bien fabriqué
Assurance qualité
personnalisation
MessageWhatsApp
Numéro de hotline 15580327593
  • Détails du produit
  • FAQ
  • Contactez-nous
Controlled Cell-Level Abuse Testing

DR-D210 Battery Forced Internal Short Circuit Tester

Apply controlled mechanical force to a prepared lithium-ion cell inside a temperature-controlled test enclosure while recording the cell response. DR-D210 is a specialized cell test system: the cell format, contact method, conditioning, force stop criterion and monitoring channels must be matched to the adopted procedure.

Method boundary: a mechanical forced internal short is different from connecting the external cell terminals together. The quoted fixture and test programme must be reviewed against the exact standard edition and specimen design.
Published force range0–2,000 N
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits0°C to +100°C
Published force accuracy±0.5% full scale; measurement basis to confirm
Published acquisition rateUp to 100 samples/s; channel scope to confirm

What the Test System Does

Controlled force application

The published servo system applies force while reporting the measured force and travel. Confirm the force ramp, actuator resolution and stop logic for the specified method.

Temperature conditioning

The integrated chamber provides a published 0–100°C range. Specify the required cell temperature, tolerance, soak time and measurement location.

Response monitoring

Cell voltage, surface temperature and actuator force can be captured during the event. Define channel count, sample rate per channel, trigger and exported record.

Published DR-D210 Values and Quotation Checks

Article Published statement Confirm before ordering
Force range 0–2,000 N Calibrated measurement range, force resolution, ramp and permitted overload.
Précision de la force ±0.5% full scale Whether this is force measurement or control accuracy; calibration evidence.
Plage de température 0°C to +100°C Stability, loaded performance, cell temperature sensor and conditioning duration.
Data acquisition Jusqu'à 100 échantillons par seconde Rate for each recorded channel, timestamps, trigger, storage and export format.
Control PLC and touchscreen Programme capacity, event stop conditions and user access controls.
Cell formats Cylindrical and prismatic cells described; other formats discussed as options Exact cell dimensions, contact position, fixture drawing and sample-preparation method.
Test enclosure Stainless-steel interior, observation window and exhaust described Final safety package, exhaust connection, emergency stop and facility interface.

Define the Test Method Before Selecting the Fixture

Adopt the exact document

Record the applicable standard, edition, clause, cell scope and laboratory procedure.

Prepare the cell

Define the permitted cell construction, charge state, conditioning and any controlled preparation required by the method.

Set the contact geometry

Approve the fixture, indenter/contact location, alignment and restraint for the selected cell format.

Set force and stop criteria

Specify force ramp, displacement, voltage event, maximum limits and safe-state response.

Record the response

Capture synchronized force, travel, voltage, temperature, event time and observations as required.

Apply the actual acceptance rule

Use the criteria in the adopted procedure and report deviations, venting or other abnormal events.

Fixture and Cell Scope

Format de cellule cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Procurement evidence
Cylindrical Cell diameter/length, orientation, restraint and contact location Approved fixture drawing and representative-cell trial.
Prismatic Cell face, thickness, clamping and contact geometry Approved alignment drawing and travel clearance.
Pochette Method applicability, support surface, swelling clearance and damage risk Written method review before quoting a fixture; do not assume universal compatibility.
Multiple sizes Changeover time, fixture set and sensor repositioning Itemized fixture list and FAT with representative sizes.

Safety and Facility Interfaces

Function Required project definition
Enclosure and viewing Event energy, door/window construction, observation method and access interlock.
Exhaust Expected gas/smoke, connection size, flow, discharge route and facility approval.
Emergency stop Actuator stop, specimen power isolation, chamber response and restart permission.
Detection and alarms Which sensors are supplied, thresholds, calibration and cause-and-effect logic.
Post-event handling Remote observation, cooldown, ventilation, disposal and laboratory procedure.
Safety claim: the words “explosion-proof” on the existing page do not establish a certified containment rating. Confirm the actual design basis and any certificate applicable to the quoted configuration.

Use Standards for Their Actual Test Scope

Reference cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Decision for DR-D210
IEC 62133-2 Safety of portable sealed lithium cells and batteries Check the adopted edition and whether its forced-internal-short procedure applies to the intended cell; approve fixture and method before claiming support.
JIS C 8714 Japanese lithium-ion cell and battery safety requirements Confirm current applicable edition, specimen preparation and precise procedure.
IEC 62619 / IEC 62660-3 Industrial and automotive cell safety programmes Map the requested clause separately; these references do not make every DR-D210 function universally compliant.
UN 38.3 Lithium transport test programme T.5 is an external short-circuit test. This mechanical FISC tester is not a substitute for the UN 38.3 T.5 apparatus.

For transport-related low-pressure testing, review the separate DR-D203 battery altitude simulation chamber. It serves a different procedure and equipment purpose.

Records and Factory Acceptance

Force calibration

Check force-indication accuracy at agreed points and verify actuator travel, ramp and stop behaviour with a safe dummy specimen.

Temperature and channels

Map agreed temperature points and confirm voltage, temperature, force and displacement channels, timestamps and export.

Safety cause and effect

Demonstrate door interlock, emergency stop, overload, alarms, exhaust command and safe recovery without using a live cell for basic functional checks.

What to Send for an Accurate Proposal

Topic cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Method Standard, edition, clause, laboratory procedure and acceptance criteria.
Cells Chemistry, format, dimensions, capacity, energy, construction and quantities.
Preparation Permitted cell preparation, charge state, conditioning and handling.
Mechanical profile Fixture geometry, force range, ramp, travel and stop trigger.
Environment and records Temperature point, channels, sample rate, data format and report.
Facility safety Ventilation, exhaust, fire response, power and operator access controls.

Foire Aux Questions

Is FISC the same as an external short-circuit test?

No. FISC uses a specified prepared cell and mechanical procedure to induce an internal event; an external short-circuit test connects the cell or battery terminals through an external circuit.

Can DR-D210 perform UN 38.3 T.5?

No such capability is established. T.5 is an external short-circuit test and requires a different test setup.

Does a 2,000 N maximum mean every cell uses 2,000 N?

No. The test programme sets the relevant force ramp and termination conditions for the selected cell and method. The published number is an equipment range limit.

Are all cell formats covered?

The current page describes cylindrical and prismatic cells and mentions other fixtures. Confirm method applicability and an approved fixture for each exact cell format.

Does the tester guarantee a pass under IEC 62133-2?

No. The applicable edition, specimen, preparation, test procedure and acceptance rule determine the result. Equipment capability and cell compliance are separate matters.

What should be witnessed at FAT?

Verify force and temperature measurements, channel timing/export, fixture fit, control sequence, interlocks, exhaust command and documentation using safe representative checks.

Specify the Cell and Procedure Before the Tester

Send the cell format, adopted method, preparation, force profile and safety requirements. DERUI can confirm the fixture, control range, monitoring channels and FAT scope for the quoted DR-D210 configuration.

Request a DR-D210 Method Review

FacebookLinkedInXRedditWhatsApp

1. Q : Qu’est-ce qu’un testeur de court-circuit interne forcé de batterie (FISC) ?
A: R : Un testeur de court-circuit interne forcé de batterie est une machine de test de sécurité spécialisée conçue pour induire et simuler intentionnellement un court-circuit interne au sein d’une cellule de batterie lithium-ion. Il applique une force mécanique précise pour reproduire des modes de défaillance tels que la rupture du séparateur ou la pénétration de dendrites, permettant aux fabricants d’évaluer la réponse de sécurité de la cellule, son comportement thermique et le risque de thermal runaway dans des conditions contrôlées en laboratoire.

2. Q : Quelle est la principale différence entre un test de court-circuit interne et externe ?
A: La différence clé réside dans l'emplacement de la défaillance et l'objectif du test. Un test de court-circuit interne (FISC) simule une défaillance à l'intérieur de la cellule (par exemple, défaillance du séparateur) pour évaluer la sécurité du cœur et le risque de thermal runaway. Un test de court-circuit externe relie les bornes externes de la cellule.

pour évaluer le système de gestion de la batterie et les circuits de protection externes. Les tests FISC sont considérés comme une validation de sécurité plus sévère et fondamentale.
A: 3. Q : Quelles normes de sécurité exigent ou recommandent les tests de court-circuit interne forcé (FISC) ? IEC 62133-2 Les principales normes de sécurité internationales exigeant ou recommandant les tests FISC incluent, (Clause 8.3.9 pour les cellules portables),, et JIS C 8714:2007 UL 1973 IEC 62660-3 pour le stockage stationnaire. C'est également une méthode d'évaluation critique dans UN 38.3 pour les batteries automobiles et soutient la validation pour.

les exigences de sécurité lors du transport.
A: 4. Q : Comment un testeur FISC applique-t-il une force pour créer un court-circuit interne ? système de moteur à servo haute précision pour appliquer une force contrôlée et progressive (généralement jusqu'à 2000 N) via une sonde ou un indenteur sur la cellule de batterie. Cette force déforme les couches internes (anode, séparateur, cathode) jusqu'à ce qu'elles entrent en contact, créant un court-circuit interne contrôlé, tout en surveillant en temps réel des paramètres tels que la force, la déformation, la tension et la température.

5. Q : Pourquoi une chambre de température intégrée est-elle importante pour les tests FISC ?
A: La performance de sécurité de la batterie dépend fortement de la température. Une chambre de température intégrée (par exemple, une plage de 0°C à 100°C) permet de tester dans diverses conditions environnementales. Cela est crucial pour évaluer si une cellule est plus susceptible de provoquer une thermal runaway lorsqu'un court-circuit interne se produit à des températures élevées ou basses, fournissant ainsi des données de sécurité plus complètes.

6. Q : Quelles données critiques sont surveillées lors d'un test FISC ?
A: Pendant un test, l'équipement surveille la chute de tension (pour détecter le court-circuit), la température de la surface et de l'intérieur de la cellule (pour suivre la génération de chaleur et le début de la thermal runaway), et la force/déplacement appliqué. Des systèmes avancés échantillonnent ces données à haute vitesse (par exemple, 100 échantillons/sec) pour capturer avec précision la séquence rapide des événements de défaillance.

7. Q : Quelles sont les caractéristiques de sécurité essentielles du testeur lui-même ?
A: Étant donné la nature dangereuse du test, le testeur doit disposer de construction résistante aux explosions, une chambre de sécurité scellée avec une fenêtre d'observation, un système de suppression automatique d'incendie (par exemple, CO2), Évents d’échappement de gaz nocifs, et boutons d'arrêt d'urgence. Ces caractéristiques protègent les opérateurs et l’équipement contre une rupture potentielle de la cellule ou un incendie.

8. Q : Quels formats de cellules de batterie peuvent être testés ?
A: Un testeur FISC polyvalent peut accueillir des cellules prismatiques, cylindriques et pouch. Cela est réalisé grâce à des dispositifs et mandrins personnalisables qui maintiennent chaque type de cellule en place pendant l’application de la force, garantissant des conditions de test cohérentes et fiables pour différentes gammes de produits.

9. Q : Comment le résultat Pass/Fail est-il déterminé lors d’un test FISC ?
A: Les critères de réussite/échec sont définis par la norme de sécurité pertinente (comme IEC 62133-2). En général, un “pass” nécessite que la cellule n’explose pas ni ne prenne feu. Les critères supplémentaires incluent souvent des limites sur la montée en température maximale, la durée de la flamme (le cas échéant), et l’absence de projection de projectiles. La journalisation des données du testeur fournit la preuve de cette évaluation.

10. Q : Qui utilise cet équipement et à quelle étape de la production ?
A: Les testeurs FISC sont utilisés par les fabricants de cellules de batterie, les intégrateurs de VE et de systèmes de stockage d’énergie (ESS), et les laboratoires d’essais indépendants. Ils sont principalement utilisés dans la phase de R&D pour la validation des matériaux et de la conception, et pour les tests de qualification et de certification. En raison de leur nature destructive, ils ne sont généralement pas utilisés sur chaque cellule en production de masse mais sur un échantillonnage pour l’assurance qualité.