Akü Yanma Test Odası

The DERUI DR-D207 battery burning test chamber uses a Bunsen burner, stainless specimen screen and removable octagonal mesh cover for specified cell or small-battery flame-exposure procedures. Confirm the exact test clause and fixture drawing before ordering.

Model DR-D207
Test Odak Noktası Controlled flame exposure with mesh surround; method-specific observation
Burner / Screen 10 mm burner mouth; 0.43 mm stainless wire, 20 openings per inch
Octagonal Cover 610 mm across opposite faces × 305 mm high; removable panels
Inner Size 750 × 750 × 500 mm (W × D × H)
Before Quotation Confirm clause/edition, cell energy and format, gas/exhaust, safety scope and FAT
Güvenli ve güvenilir
İyi yapılmış
Kalite güvencesi
Özelleştirme
MesajWhatsApp
Hattın numarası 15580327593
  • Ürün Detayları
  • Teknik parametreler
  • SSS
  • Bizimle iletişime geçin
CELL FLAME EXPOSURE & PROJECTILE-CONTAINMENT SETUP

DR-D207 Battery Burning Test Chamber

A purpose-built burner, specimen screen and removable octagonal mesh cover for controlled flame-exposure testing of approved lithium cells or small batteries. Specify the adopted method, specimen and laboratory safety plan before treating any fixture geometry as a compliance claim.

What this equipment is: a flame-exposure fixture. It is not a programmable temperature chamber, a full-size pack fire tester or a UN 38.3 transport-test system.
ModelDR-D207
Burner10 mm internal tube opening; approximately 100 mm long
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits0.43 mm stainless wire; 20 openings per inch
Internal enclosure750 × 750 × 500 mm (W × D × H)

What the Test Helps You Observe

During a specified flame-exposure procedure, a cell or approved small battery sits above the burner while the screen and octagonal surround define the setup and help retain ejected material. The laboratory observes the behavior required by its adopted method; pass/fail criteria must come from that method and the test plan, not from the chamber specification alone.

Controlled setup

Published burner, screen, opening and octagonal-cover dimensions provide a starting point for method review.

Visible evidence

Agree in advance how the operator will record exposure time, specimen behavior and any ejected material.

Safer procurement

Confirm fuel supply, exhaust, operator protection and post-test handling before ordering.

Published DR-D207 Configuration

Ürün Published value cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Control and timer Button control; flame-time setting shown as 0–99H99M Confirm actual timer input format, resolution and shutoff behavior.
Burner and opening Bunsen burner, 10 mm internal mouth, approximately 100 mm length; test opening 100 ± 2 mm Confirm burner type, flame setting and fixture drawing against the adopted standard edition.
Specimen screen 0.43 mm stainless woven wire; 20 openings per inch Confirm mounting height and replacement screen supplied.
Octagonal cover 610 mm across opposite faces; 305 mm high; eight removable panels; 0.25 mm aluminum wire, 16–18 openings per inch Request dimensional drawing and panel-retention details.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 750 × 750 × 500 mm internal; 1000 × 950 × 1310 mm external, including door lock Confirm usable clearance around the fixture and doorway.
Kullanılanlar Methane or LPG supplied by customer; 220 V, 50/60 Hz, 200 W; approximately 160 kg Confirm gas regulation, ventilation, site power and nameplate.
Relief and exhaust 200 × 200 mm pressure-relief door; rear Ø100 mm exhaust connection; door-retention chain Confirm discharge direction, duct requirements and risk-assessed containment limits.
Dimension requiring a drawing: the old specification states “height of the flame from the screen: 38 mm.” That wording does not unambiguously define the burner-to-screen geometry; verify it on the approved setup drawing.

Method Fit: Review the Clause, Not a Logo List

The DR-D207 screen and octagonal-surround geometry warrants review against the UL 1642 Projectile Test, but published fixture similarity is not proof of conformance. In particular, the DR-D207 page specifies a Bunsen burner, while a published technical comparison describes a Meker-type burner for the UL 1642 fire-exposure setup. Verify the adopted edition, burner, all dimensions, specimen preparation, observation and acceptance rules clause by clause before any UL 1642 claim.

Do not treat this chamber as a UN 38.3 test method. The UN transport manual has defined T.1–T.8 tests; a generic “UN 38.3 T.10 burning test” claim should not appear on this page. Other standards such as UL 2054 or IEC 62133-2 may form part of a laboratory program but do not automatically validate this fixture.

Send the exact method

Standard edition, clause, cell format, sample state, exposure period and pass/fail rule.

Confirm the physical setup

Burner specification, mesh, opening, screen-to-burner position and octagonal-cover drawing.

Confirm evidence

Video/observation plan, timed exposure, calibration records and final report format.

DR-D207 Is Different from DERUI's Other Battery Fire Equipment

Equipment Primary function Do not assume
DR-D207 burning test chamber Burner, screen and octagonal mesh fixture for specified cell/small-battery flame exposure Large pack fire testing, programmable heating or certified blast containment
DR-D211 EV battery cell fire tester A different external-flame test setup; compare its published specimen and burner limits separately Interchangeability with the DR-D207 projectile-test geometry
Battery thermal abuse chamber Controlled high-temperature exposure in a heated enclosure An open-flame burner or octagonal-mesh projectile-test fixture

Site Safety and Acceptance Plan

Review the specimen

Provide chemistry, dimensions, maximum energy, charge state and credible venting behavior. Agree allowable specimen size and quantity.

Review the facility

Confirm methane/LPG supply, regulator, exhaust route, clearance, fire response and operator exclusion area with site EHS.

Witness the setup

Check burner, screen and cover dimensions, timer, gas shutoff behavior, exhaust, door and documentation during FAT.

Safety boundary: the published relief door and retention chain are construction features, not evidence of a rated explosion-proof or thermal-runaway containment system. Gas detection, suppression, data export and interlocks are not established as standard features by the current public specification.

Questions Buyers Ask

Is this a UL-certified chamber?

No certification evidence is established by the public product page. Review fixture suitability against the exact UL 1642 edition and obtain any required third-party evaluation separately.

Can it test EV modules or packs?

Do not infer that from the enclosure size. Obtain a specimen-size, energy and hazard assessment, then compare the appropriate larger-scale equipment.

Is the gas included?

The published specification says methane or LPG is customer-provided. Confirm regulator, hose, shutoff and local installation scope in the quotation.

Does it perform UN 38.3 transport testing?

No. This burner arrangement should not be presented as a UN 38.3 test. Choose the dedicated equipment for the required T.1–T.8 method.

What needs confirmation before publication or purchase?

The adopted standard edition, fixture drawing, timer format, safety controls, real-device photos, accessories and measurable FAT criteria.

Request a Method-Matched DR-D207 Proposal

Send your cell drawing and test clause. DERUI can respond with the fixture drawing, included scope, utility list and an acceptance checklist that engineering and purchasing can review together.

Discuss the DR-D207 setup

Include in the inquiry

  • Standard edition and exact clause
  • Cell/battery format and energy
  • Gas and exhaust conditions
  • Required observation and FAT records
FacebookLinkedInXRedditWhatsApp

DR-D207 values below come from the current DERUI product record. Confirm the approved drawing and safety configuration before ordering.

Ürün Published configuration / verification point
Model / control DR-D207; button control
Burner Bunsen burner; 10 mm internal tube-mouth diameter; approximately 100 mm tube length
Flame-time setting Published as 0–99H99M; confirm valid timer input format, resolution and shutoff logic
Test opening 100 ± 2 mm diameter
Specimen screen Stainless woven wire, 0.43 mm diameter; 20 openings per inch
Burner/screen geometry Published “38 mm” wording is ambiguous; require approved dimensioned drawing
Octagonal mesh cover 610 mm across opposite faces; 305 mm high; eight removable faces; 0.25 mm aluminum wire, 16–18 openings per inch
Fuel Methane or LPG; customer-provided. Confirm regulator, supply and shutoff requirements
Inner / outer dimensions 750 × 750 × 500 mm / 1000 × 950 × 1310 mm (W × D × H; outer includes door lock)
Relief / exhaust / door 200 × 200 mm relief door; rear Ø100 mm exhaust connection; left-opening door with retention chain. No rated containment claim established
Supply / weight 220 V single phase, 50/60 Hz, 200 W; approximately 160 kg

1. Pil Yanma Test Odası nedir?
Pil Yanma Test Odası, pil yangınlarını güvenli bir şekilde barındırmak ve incelemek için tasarlanmış, özel olarak güçlendirilmiş bir muhafazadır. Araştırmacıların lityum iyon hücrelerinde termal kaçışını kasıtlı olarak tetiklemelerine, alev yayılımını, sıcaklık profillerini ve muhafaza etkinliğini kontrollü ve tekrarlanabilir koşullarda gözlemlemelerine olanak tanır.

2. Bir Pil Yanma Test Odası ile hangi güvenlik standartları karşılanabilir?
Bu odalar, üreticilerin kritik uluslararası güvenlik standartlarına uymasına yardımcı olmak amacıyla inşa edilmiştir. Ana standartlar şunlardır UL 9540A enerji depolama sistemleri için, UN 38.3 lityum pil taşımacılığı için, ECE R100 elektrikli araçlar için ve GB/T 31485 Çin EV batarya güvenlik gereksinimleri için.

3. Hangi temel güvenlik özellikleri aranmalı?
Oda seçiminde öncelik verin otomatik yangın söndürme sistemleri (yangın sprinkleri veya inert gaz gibi), patlamaya dayanıklı yapılar, gerçek zamanlı gaz ve sıcaklık izleme, ve acil kapama anahtarları. Bu özellikler, kontrollü yanma sırasında laboratuvarınızı ve personelinizi korumak için çok önemlidir.

4. Bu odaların dayanabileceği maksimum sıcaklık nedir?
Yüksek kaliteli Batarya Yanma Test Odaları, bir batarya yangarının aşırı sıcaklığına dayanacak şekilde tasarlanmıştır. En az 1100°C (2000°F) çalışma sıcaklığına sahip modelleri tercih edin, böylece en şiddetli termal kaçış olaylarını hasar görmeden kontrol edebilirler.

5. Aynı oda farklı batarya boyutlarını ve türlerini test edebilir mi?
Evet, birçok modern oda modüler tasarım. özelliğine sahiptir. Bu, iç yapıların yeniden yapılandırılmasına veya farklı bağlantıların kullanılmasına olanak tanır, böylece küçük tüketici elektroniği hücrelerinden büyük formatlı EV veya ESS (Enerji Depolama Sistemi) batarya modüllerine kadar her şeyi güvenli bir şekilde test edebilirsiniz.

6. Bir test sırasında odacık ne tür veriler toplar?
Gelişmiş odalar, veri toplama sistemleriyle donatılmıştır ve bunlar yakalar yüksek hızlı sıcaklık verisi birden fazla termokupldan, basınç değişiklikleri, ve isteğe bağlı modüllerle, gaz bileşimi analizi yanma sırasında üretilen gaz çıkışındaki gaz.

7. Yangın testinden sonra oda nasıl temizlenir ve bakımı nasıl yapılır?
Post-test temizlik, yangın kalıntılarını kaldırmayı ve bileşenleri incelemeyi içerir. Odalar ile pürüzsüz, paslanmaz çelik iç yüzeyler, çıkarılabilir kalıntı tepsileri, ve erişilebilir görünüm alanı montajları Bu süreci önemli ölçüde basitleştirin ve bir sonraki teste hazırlıklı olun.

Oda diğer test ekipmanlarıyla entegre edilebilir mi?
Kesinlikle. Harici iletimle senkronize olmalarını sağlayan standart iletişim portlarına (Ethernet, CAN) sahip modelleri arayın. çevresel odalar sıcaklık ön koşullandırması veya laboratuvarınızın merkezi ile veri yönetim sistemi birleştirilmiş raporlama için.

9. Teslimat ve kurulum için tipik öncelik süresi nedir?
Özelleştirilmiş, ağır hizmet tipi doğaları nedeniyle, Bir Pil Yakma Test Odası'nın öncelik süreleri şu aralıkta olabilir 12 ila 20 hafta. Bu, üretim, güvenlik doğrulaması ve profesyonel yerinde kurulum ve operatör eğitimi için koordinasyonu içerir.

10. Oda kalite kontrolü için mi yoksa sadece Ar-Ge için mi kullanılıyor?
Her iki işlevi de yerine getirir. İçinde Ar-Ge, mühendisler yeni hücre tasarımlarını ve malzemelerini doğrulamak için kullanır. İçinde Kalite Kontrolü, seri numune alma ve sertifikasyon testi için kullanılır; üretim hücrelerinin sevkiyat öncesinde zorunlu güvenlik düzenlemelerine uyduğundan emin olmak için.

11. Hangi tür havalandırma veya tesis hazırlığı gereklidir?
Bu odalar, test sonrası toksik buharları ve dumanları güvenli bir şekilde uzaklaştırmak için özel, güçlü egzoz havalandırma sistemi gerektirir. Tesisinizin özel güç, alan ve havalandırma gereksinimlerini anlamak için üreticiyle erken danışmak çok önemlidir.

12. Oda ile hangi destek ve garanti sağlanır?
Saygın üreticiler, sağlam bir garanti (örneğin, parça ve işçilikte 24 ay) ve kapsamlı destek sunar. Bu, şunları içermelidir: yerinde kurulum, operatör eğitimi, uzaktan tanılama, ve erişim sağlar küresel yedek parça ağı kritik bileşenler için.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MesajMesaj

Teklif Talep Edin