Batterie-Brandtestkammer

Das DERUI DR-D207 battery burning test chamber uses a Bunsen burner, stainless specimen screen and removable octagonal mesh cover for specified cell or small-battery flame-exposure procedures. Confirm the exact test clause and fixture drawing before ordering.

Modell DR-D207
Testfokus Controlled flame exposure with mesh surround; method-specific observation
Burner / Screen 10 mm burner mouth; 0.43 mm stainless wire, 20 openings per inch
Octagonal Cover 610 mm across opposite faces × 305 mm high; removable panels
Inner Size 750 × 750 × 500 mm (W × D × H)
Before Quotation Confirm clause/edition, cell energy and format, gas/exhaust, safety scope and FAT
Sicher und zuverlässig
Hochwertig hergestellt
Qualitätssicherung
Anpassung
NachrichtWhatsApp
Hotline-Nummer 15580327593
  • Produktdetails
  • Technische Parameter
  • FAQ
  • Kontaktieren Sie uns
CELL FLAME EXPOSURE & PROJECTILE-CONTAINMENT SETUP

DR-D207 Battery Burning Test Chamber

A purpose-built burner, specimen screen and removable octagonal mesh cover for controlled flame-exposure testing of approved lithium cells or small batteries. Specify the adopted method, specimen and laboratory safety plan before treating any fixture geometry as a compliance claim.

What this equipment is: a flame-exposure fixture. It is not a programmable temperature chamber, a full-size pack fire tester or a UN 38.3 transport-test system.
ModellDR-D207
Burner10 mm internal tube opening; approximately 100 mm long
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits0.43 mm stainless wire; 20 openings per inch
Internal enclosure750 × 750 × 500 mm (W × D × H)

What the Test Helps You Observe

During a specified flame-exposure procedure, a cell or approved small battery sits above the burner while the screen and octagonal surround define the setup and help retain ejected material. The laboratory observes the behavior required by its adopted method; pass/fail criteria must come from that method and the test plan, not from the chamber specification alone.

Controlled setup

Published burner, screen, opening and octagonal-cover dimensions provide a starting point for method review.

Visible evidence

Agree in advance how the operator will record exposure time, specimen behavior and any ejected material.

Safer procurement

Confirm fuel supply, exhaust, operator protection and post-test handling before ordering.

Published DR-D207 Configuration

Artikel Published value cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Control and timer Button control; flame-time setting shown as 0–99H99M Confirm actual timer input format, resolution and shutoff behavior.
Burner and opening Bunsen burner, 10 mm internal mouth, approximately 100 mm length; test opening 100 ± 2 mm Confirm burner type, flame setting and fixture drawing against the adopted standard edition.
Specimen screen 0.43 mm stainless woven wire; 20 openings per inch Confirm mounting height and replacement screen supplied.
Octagonal cover 610 mm across opposite faces; 305 mm high; eight removable panels; 0.25 mm aluminum wire, 16–18 openings per inch Request dimensional drawing and panel-retention details.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 750 × 750 × 500 mm internal; 1000 × 950 × 1310 mm external, including door lock Confirm usable clearance around the fixture and doorway.
Versorgungsunternehmen Methane or LPG supplied by customer; 220 V, 50/60 Hz, 200 W; approximately 160 kg Confirm gas regulation, ventilation, site power and nameplate.
Relief and exhaust 200 × 200 mm pressure-relief door; rear Ø100 mm exhaust connection; door-retention chain Confirm discharge direction, duct requirements and risk-assessed containment limits.
Dimension requiring a drawing: the old specification states “height of the flame from the screen: 38 mm.” That wording does not unambiguously define the burner-to-screen geometry; verify it on the approved setup drawing.

Method Fit: Review the Clause, Not a Logo List

The DR-D207 screen and octagonal-surround geometry warrants review against the UL 1642 Projectile Test, but published fixture similarity is not proof of conformance. In particular, the DR-D207 page specifies a Bunsen burner, while a published technical comparison describes a Meker-type burner for the UL 1642 fire-exposure setup. Verify the adopted edition, burner, all dimensions, specimen preparation, observation and acceptance rules clause by clause before any UL 1642 claim.

Do not treat this chamber as a UN 38.3 test method. The UN transport manual has defined T.1–T.8 tests; a generic “UN 38.3 T.10 burning test” claim should not appear on this page. Other standards such as UL 2054 or IEC 62133-2 may form part of a laboratory program but do not automatically validate this fixture.

Send the exact method

Standard edition, clause, cell format, sample state, exposure period and pass/fail rule.

Confirm the physical setup

Burner specification, mesh, opening, screen-to-burner position and octagonal-cover drawing.

Confirm evidence

Video/observation plan, timed exposure, calibration records and final report format.

DR-D207 Is Different from DERUI's Other Battery Fire Equipment

Equipment Primary function Do not assume
DR-D207 burning test chamber Burner, screen and octagonal mesh fixture for specified cell/small-battery flame exposure Large pack fire testing, programmable heating or certified blast containment
DR-D211 EV battery cell fire tester A different external-flame test setup; compare its published specimen and burner limits separately Interchangeability with the DR-D207 projectile-test geometry
Battery thermal abuse chamber Controlled high-temperature exposure in a heated enclosure An open-flame burner or octagonal-mesh projectile-test fixture

Site Safety and Acceptance Plan

Review the specimen

Provide chemistry, dimensions, maximum energy, charge state and credible venting behavior. Agree allowable specimen size and quantity.

Review the facility

Confirm methane/LPG supply, regulator, exhaust route, clearance, fire response and operator exclusion area with site EHS.

Witness the setup

Check burner, screen and cover dimensions, timer, gas shutoff behavior, exhaust, door and documentation during FAT.

Safety boundary: the published relief door and retention chain are construction features, not evidence of a rated explosion-proof or thermal-runaway containment system. Gas detection, suppression, data export and interlocks are not established as standard features by the current public specification.

Questions Buyers Ask

Is this a UL-certified chamber?

No certification evidence is established by the public product page. Review fixture suitability against the exact UL 1642 edition and obtain any required third-party evaluation separately.

Can it test EV modules or packs?

Do not infer that from the enclosure size. Obtain a specimen-size, energy and hazard assessment, then compare the appropriate larger-scale equipment.

Is the gas included?

The published specification says methane or LPG is customer-provided. Confirm regulator, hose, shutoff and local installation scope in the quotation.

Does it perform UN 38.3 transport testing?

No. This burner arrangement should not be presented as a UN 38.3 test. Choose the dedicated equipment for the required T.1–T.8 method.

What needs confirmation before publication or purchase?

The adopted standard edition, fixture drawing, timer format, safety controls, real-device photos, accessories and measurable FAT criteria.

Request a Method-Matched DR-D207 Proposal

Send your cell drawing and test clause. DERUI can respond with the fixture drawing, included scope, utility list and an acceptance checklist that engineering and purchasing can review together.

Discuss the DR-D207 setup

Include in the inquiry

  • Standard edition and exact clause
  • Cell/battery format and energy
  • Gas and exhaust conditions
  • Required observation and FAT records
FacebookLinkedInXRedditWhatsApp

DR-D207 values below come from the current DERUI product record. Confirm the approved drawing and safety configuration before ordering.

Artikel Published configuration / verification point
Model / control DR-D207; button control
Burner Bunsen burner; 10 mm internal tube-mouth diameter; approximately 100 mm tube length
Flame-time setting Published as 0–99H99M; confirm valid timer input format, resolution and shutoff logic
Test opening 100 ± 2 mm diameter
Specimen screen Stainless woven wire, 0.43 mm diameter; 20 openings per inch
Burner/screen geometry Published “38 mm” wording is ambiguous; require approved dimensioned drawing
Octagonal mesh cover 610 mm across opposite faces; 305 mm high; eight removable faces; 0.25 mm aluminum wire, 16–18 openings per inch
Fuel Methane or LPG; customer-provided. Confirm regulator, supply and shutoff requirements
Inner / outer dimensions 750 × 750 × 500 mm / 1000 × 950 × 1310 mm (W × D × H; outer includes door lock)
Relief / exhaust / door 200 × 200 mm relief door; rear Ø100 mm exhaust connection; left-opening door with retention chain. No rated containment claim established
Supply / weight 220 V single phase, 50/60 Hz, 200 W; approximately 160 kg

1. Was ist eine Batterie-Brandtestkammer?
Eine Batterie-Brandtestkammer ist ein spezieller, stark verstärkter Gehäuse, das entwickelt wurde, um Batteriebrände sicher zu enthalten und zu untersuchen. Sie ermöglicht es Forschern, absichtlich thermisches Durchgehen in Lithium-Ionen-Zellen zu verursachen, Flammenausbreitung, Temperaturprofile und Wirksamkeit der Eindämmung unter kontrollierten, wiederholbaren Bedingungen zu beobachten.

2. Welche Sicherheitsstandards können mit einer Batterie-Brandtestkammer erfüllt werden?
Diese Kammern werden gebaut, um Herstellern zu helfen, wichtige internationale Sicherheitsstandards einzuhalten. Wichtige davon sind UL 9540A für Energiespeichersysteme, UN 38.3 für den Transport von Lithium-Batterien, ECE R100 für Elektrofahrzeuge, und GB/T 31485 für chinesische Sicherheitsanforderungen an EV-Batterien.

3. Was sind die wichtigsten Sicherheitsmerkmale, auf die man achten sollte?
Priorisieren Sie Kammern mit automatischen Feuerlöschsystemen (wie Sprinkler oder Inertgas), explosionssichere Bauweise, Echtzeit-Gas- und Temperaturüberwachung, und Not-Aus-Schaltern. Diese Merkmale sind entscheidend, um Ihr Labor und Personal während eines kontrollierten Brandes zu schützen.

4. Welcher maximale Temperaturbereich kann diese Kammer aushalten?
Hochwertige Batterie-Brandtestkammern sind so konstruiert, dass sie die extremen Hitzeentwicklung eines Batteriebrandes aushalten. Achten Sie auf Modelle mit einer maximalen Betriebstemperatur von mindestens 1100°C (2000°F) um sicherzustellen, dass sie die schwersten thermischen Durchgehen ohne Schaden enthalten können.

5. Kann die gleiche Kammer verschiedene Batterietypen und -größen testen?
Ja, viele moderne Kammern verfügen über ein modulares Design. Dies ermöglicht eine interne Neukonfiguration oder die Verwendung verschiedener Vorrichtungen, um alles von kleinen Verbraucher-Elektronikzellen bis hin zu großformatigen EV- oder ESS-Batteriemodulen sicher zu testen.

6. Welche Art von Daten sammelt die Kammer während eines Tests?
Fortschrittliche Kammern sind mit integrierten Datenerfassungssystemen ausgestattet, die Hochgeschwindigkeits-Temperaturdaten von mehreren Thermoelementen erfassen, Druckänderungen, und mit optionalen Modulen, Gaszusammensetzungsanalyse des Abgases, das während der Verbrennung entsteht.

7. Wie wird die Kammer nach einem Brandtest gereinigt und gewartet?
Nach dem Test umfasst die Reinigung die Entfernung von Brandrückständen und die Inspektion der Komponenten. Kammern mit glatten, Edelstahl-Innenräumen, abnehmbaren Schmutzauffangschalen, und zugänglichen Sichtfensterbaugruppen vereinfachen diesen Prozess erheblich und sorgen für die Einsatzbereitschaft für den nächsten Test.

8. Kann die Kammer mit anderen Testgeräten integriert werden?
Absolut. Achten Sie auf Modelle mit Standard-Kommunikationsanschlüssen (Ethernet, CAN), die es ihnen ermöglichen, mit externen Umweltkammern zur Temperaturvorbereitung oder mit der zentralen Steuerung Ihrer Laboreinrichtung zu synchronisieren. Datenmanagementsystem für konsolidierte Berichterstattung.

9. Wie ist die typische Lieferzeit für Lieferung und Installation?
Aufgrund ihrer kundenspezifischen, robusten Natur können die Lieferzeiten für eine Batteriebrennkammer zwischen 12 und 20 Wochen. liegen. Dies umfasst die Herstellung, Sicherheitsvalidierung und Koordination für professionelle Vor-Ort-Installation und Schulung des Bedienpersonals.

10. Wird die Kammer für Qualitätskontrolle oder nur für Forschung und Entwicklung verwendet?
Sie erfüllt beide Funktionen. In F&E, verwenden Ingenieure sie, um neue Zellendesigns und Materialien zu validieren. In Qualitätskontrolle, wird sie für Chargenprobenahme und Zertifizierungstests genutzt, um sicherzustellen, dass Produktionszellen die gesetzlichen Sicherheitsvorschriften vor dem Versand erfüllen.

11. Welche Art von Belüftung oder Anlagenvorbereitung ist erforderlich?
Diese Kammern benötigen ein dediziertes, leistungsstarkes Abluft-Absaugsystem um giftige Dämpfe und Rauch nach einem Test sicher zu entfernen. Es ist entscheidend, frühzeitig mit dem Hersteller zu sprechen, um die spezifischen Anforderungen an Stromversorgung, Raum und Belüftung Ihrer Einrichtung zu verstehen.

12. Welche Unterstützung und Garantie sind im Lieferumfang enthalten?
Renommierte Hersteller bieten eine umfassende Garantie (z.B. 24 Monate auf Teile und Verarbeitung) und umfassenden Support. Dies sollte umfassen Vor-Ort-Installation, Schulung des Bedienpersonals, Fern-Diagnose, und Zugang zu einem globalen Ersatzteilnetzwerk für kritische Komponenten.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
NachrichtNachricht

Anfrage für ein Angebot