Calle Shugang 1, No. 3, Town de Hongmei, Ciudad de Dongguan, Provincia de Guangdong, China

Fabricante de cámaras de prueba ambiental con 20 años de experienciaMás de 3000 entregas a clientes en todo el mundo           Correo electrónico: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Cámara de prueba de compresión de batería

La DERUI battery impact test chamber uses a 9.1 ± 0.1 kg falling mass and a 15.8 ± 0.1 mm crossbar to evaluate a defined cell-impact event. Select the specimen, fixture and drop height against the exact adopted test procedure.

Tipo de prueba Gravity-drop impact on a battery cell; not a crush or forced-short test
Drop Mass 9.1 ± 0.1 kg
Altura de caída 0–700 mm adjustable; published height error ±5 mm
Crossbar 15.8 ± 0.1 mm diameter; material and length to confirm for the method
Control PLC touchscreen, electric lift and electromagnetic release
Before Quotation Confirm cell format, standard edition, fixture, monitoring and facility exhaust
Segura y confiable
bien hecha
Garantía de calidad
personalización
MensajeWhatsApp
Número de línea directa 15580327593
  • Detalles del producto
  • Parámetros técnicos
  • Preguntas frecuentes
  • Contáctanos
Controlled Battery Cell Impact

Battery Impact Test Chamber for 9.1 kg Drop Testing

Evaluate a defined gravity-impact event on a cell using an electrically raised, electromagnetically released 9.1 kg mass and a 15.8 mm crossbar. The enclosed system is intended for laboratories that need a repeatable drop setup and a documented, specimen-specific test plan.

Method boundary: match the cell format, bar orientation, drop height and acceptance criteria to the exact procedure. A battery impact test is not a crush test or a forced internal-short-circuit test.
Drop mass9.1 ± 0.1 kg
Adjustable height0–700 mm; published height error ±5 mm
Crossbar diameter15.8 ± 0.1 mm
ControlPLC touchscreen, electric lift and electromagnetic release

What This Equipment Is Designed to Do

Set the impact geometry

Place the cell on the steel impact surface and position the specified crossbar across the specimen. Confirm bar material, length and orientation against the test document.

Control mass and height

Set the height, lift the mass electrically and release it through the electromagnet. The published range accommodates the 610 mm nominal setting used in certain impact procedures.

Observe within an enclosure

The cabinet includes an observation window and rear exhaust fan. The project-specific hazard assessment still determines ventilation, personnel exclusion and emergency response.

Published Technical Parameters

These are values published on the current DERUI product page. Confirm the final equipment drawing, test fixture and supplied documentation in the quotation.

Parámetro Published value Quotation or FAT check
Drop mass 9.1 ± 0.1 kg Mass identification and calibration record.
Drop height 0–700 mm adjustable; height error ±5 mm Reference point, physical height verification and repeatability at the intended setting.
Precisión de visualización 0.1 mm Display increment is not the same as ±5 mm height accuracy.
Crossbar 15.8 ± 0.1 mm diameter Material, length, straightness and orientation for the adopted procedure.
Controller and lift PLC touchscreen; electric lifting Setpoint, release sequence, door-state logic and event record.
Inner and outer panels SUS304 stainless inner sheet 1.0 mm; painted cold-rolled outer sheet 1.0 mm Final assembly construction and protective rating require separate evidence.
Window and door 390 × 360 mm, 10 mm tempered-glass window; single door with lock Do not infer a certified blast-containment rating from glass thickness alone.
Exhaust Φ120 mm outlet with rear fan Facility extraction, discharge route and treatment requirements.
Footprint and utilities W940 × D780 × H1620 mm; AC220 V ±10%, 50 Hz; 2.0 kW; approx. 250 kg Site access, power circuit, ventilation and service clearances.

Define the Impact Procedure Before Testing

Select the exact method

Identify the standard edition, clause, eligible cell type and required sample count.

Prepare the specimen

Specify cell dimensions, state of charge, conditioning and identification in the approved plan.

Check the fixture

Verify bar material and size, cell support, placement and alignment before loading the mass.

Verify the height

Measure from the method-defined reference point and document the actual pre-release position.

Release and observe

Operate the release from a protected position and record event time, temperature and visible response using the agreed instrumentation.

Apply acceptance criteria

Judge the result under the adopted standard and record deviations; the chamber itself does not certify a cell.

UN 38.3 T.6: Capability Versus Test Compliance

UN Manual of Tests and Criteria, subsection 38.3.4.6, describes an impact route for specified cylindrical cells and a separate crush route for other cells. Its impact setup calls for a 9.1 ± 0.1 kg mass, a 15.8 ± 0.1 mm stainless-steel bar and a 61 ± 2.5 cm drop. The published equipment values cover the mass, diameter and adjustable height; bar material and length, guide behavior, specimen scope and the full procedure must be checked in the approved technical agreement.

Important distinction: do not use this gravity-impact machine to represent every UN 38.3 T.6 cell format. Confirm whether your specimen requires the impact route or a separate crush method under the applicable edition.

Safety and Facility Integration

Enclosure is not a rating

The published steel cabinet and tempered observation glass describe physical construction, not a verified thermal-runaway or blast-containment class.

Exhaust needs a route

The Φ120 mm outlet and fan need a site-specific extraction design. Check expected gas, smoke and fire scenarios with the laboratory safety team.

Interlocks need verification

Confirm door interlock, emergency stop, release inhibit, remote observation and post-event access rules in the final configuration and FAT.

Recommended Factory Acceptance Checks

Verificar Witness evidence
Mass and bar Measured mass, bar diameter, material and length; traceable instruments.
Height setting Measured drop height at the agreed setting, including the reference point and stated tolerance.
Release path Observed vertical fall, bar alignment, electromagnet release and retrieval sequence.
Control and safeguards PLC display, door-state behavior, release inhibit and emergency-stop action as contracted.
Site interfaces Electrical nameplate, exhaust connection, clearances and maintenance access.
Documentación Drawing, manual, wiring, inspection record and calibration scope agreed before shipment.

Preguntas Frecuentes

Is this a UN 38.3 T.6 impact machine?

Its published mass, bar diameter and height range can support the impact geometry, but method suitability depends on the exact standard edition, eligible cell type, bar specification, guide and witnessed setup. Compliance cannot be concluded from three numbers alone.

Can it test pouch and prismatic cells under the same T.6 impact procedure?

Do not assume so. The UN 38.3 T.6 method distinguishes impact and crush routes by specimen scope. Review the applicable edition and use the correct apparatus for the selected route.

Does 0.1 mm display precision mean 0.1 mm drop-height accuracy?

No. The page separately publishes ±5 mm height error. Confirm the measurement reference and verification method at the intended height.

Does the window make the cabinet explosion-proof?

No certified containment rating has been verified from the published glass and sheet thickness. Request a documented hazard assessment and safety package for the specimen risk.

Are test curves and data export standard?

The current published parameter table confirms a PLC touchscreen, but does not establish the exact recorded channels or export format. Include these requirements in the RFQ.

What should be sent for a quotation?

Send cell format and dimensions, applicable standard/edition, test route, sample count, state of charge, bar/fixture requirement, monitoring channels, facility exhaust and requested acceptance evidence.

Configure the Correct Impact Test Setup

Share your specimen drawing and the exact test clause. DERUI can review fixture geometry, equipment scope and FAT evidence before a configuration is quoted.

Request a technical quotation

Send with your inquiry

  • Cell type, dimensions and sample count
  • Standard edition and test clause
  • Drop height and fixture drawing
  • Monitoring, exhaust and safety requirements
FacebookLinkedInXRedditWhatsApp
No. Artículo Detalles
1 Rango de medición 1 - 15 kN (13 kN estándar)
2 Visualización del valor de fuerza Pantalla táctil, unidades: kg, N, LB, etc.
3 Precisión de medición de fuerza ±1%
4 Método de prueba Accionamiento hidráulico. Cuando la extrusión continúa hasta alcanzar la presión real, mantener la presión hasta el tiempo establecido y luego liberar automáticamente la presión para completar la extrusión.
5 Carril de extrusión 300 mm
6 Tiempo de mantenimiento 0 - 99 s
7 Cabezal de extrusión Diámetro 150 mm
8 Espacio de prueba efectivo (Ancho * Profundidad * Altura) Aproximadamente 300 * 300 * 450 mm
9 Material de la caja Caja interior de acero inoxidable, resistente a altas temperaturas, aislante, anticorrosiva; caja exterior de acero laminado en frío con tratamiento de pintura horneada
10 Ventana de observación visual 250 * 250 mm, vidrio templado multicapa y malla de acero inoxidable
11 Ventana de alivio de presión 200. La abertura de alivio de presión se abrirá para liberar presión cuando la muestra explote.
12 Sistema de ventilación e iluminación Hay una salida de aire en la parte trasera de la caja y una luz en el interior de la misma.
13 Dimensiones del equipo (Longitud * Ancho * Altura) Aproximadamente 700 * 750 * 1700 mm
14 Peso del equipo Aproximadamente 220 kg
15 Fuente de alimentación de trabajo AC380V, 2KW

1, ¿Qué es una cámara de prueba de aplastamiento de baterías?
Una cámara de prueba de aplastamiento de baterías es un dispositivo de prueba utilizado para evaluar el rendimiento de las baterías bajo compresión.

2, ¿Cuál es el propósito de la cámara de prueba de aplastamiento de baterías?
Se utiliza principalmente para probar la seguridad y fiabilidad de las baterías en condiciones extremas.

3, ¿Para qué tipos de baterías es adecuada la cámara de prueba de aplastamiento de baterías?
Es adecuada para varios tipos de baterías, como baterías de litio, baterías de plomo-ácido, baterías de hidruro de níquel-metal, etc.

4, ¿Cuál es el principio de funcionamiento de la cámara de prueba de aplastamiento de baterías?
El sistema de accionamiento hidráulico aplica presión a la batería para simular la situación real cuando la batería es aplastada. Cuando se alcanza y mantiene la presión estable hasta el estado de presión real, mantiene la presión durante el tiempo establecido y luego libera automáticamente la presión para completar la prueba.

5, ¿Por qué se realiza la prueba de aplastamiento de baterías?
Para detectar la seguridad y estabilidad de la batería cuando es aplastada, evaluar el rendimiento de la batería ante impactos de fuerza externa y prevenir posibles riesgos de seguridad como explosiones e incendios durante el uso real.

6, ¿Qué funciones únicas tiene la cámara de prueba de aplastamiento de baterías?
Cuenta con funciones automáticas de mantenimiento y liberación de presión. Cuando la compresión continúa hasta la presión real, puede mantener la presión durante el tiempo establecido y luego liberarla automáticamente. Está equipada con una ventana de observación visual y una ventana de liberación de presión, que facilitan la observación del proceso de prueba y la gestión de emergencias.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MensajeMensaje

Solicitar una Cotización