Boden 1, Nr. 3, Shugang Avenue, Hongmei Town, Dongguan City, Guangdong Province, China

Hersteller von Umwelttestkammern seit 20 JahrenMehr als 3000 Kunden weltweit geliefert           E-Mail: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Batterie-Zerdrücktestkammer

Das DERUI battery impact test chamber uses a 9.1 ± 0.1 kg falling mass and a 15.8 ± 0.1 mm crossbar to evaluate a defined cell-impact event. Select the specimen, fixture and drop height against the exact adopted test procedure.

Testart Gravity-drop impact on a battery cell; not a crush or forced-short test
Drop Mass 9.1 ± 0.1 kg
Fallhöhe 0–700 mm adjustable; published height error ±5 mm
Crossbar 15.8 ± 0.1 mm diameter; material and length to confirm for the method
Control PLC touchscreen, electric lift and electromagnetic release
Before Quotation Confirm cell format, standard edition, fixture, monitoring and facility exhaust
Sicher und zuverlässig
Hochwertig hergestellt
Qualitätssicherung
Anpassung
NachrichtWhatsApp
Hotline-Nummer 15580327593
  • Produktdetails
  • Technische Parameter
  • FAQ
  • Kontaktieren Sie uns
Controlled Battery Cell Impact

Battery Impact Test Chamber for 9.1 kg Drop Testing

Evaluate a defined gravity-impact event on a cell using an electrically raised, electromagnetically released 9.1 kg mass and a 15.8 mm crossbar. The enclosed system is intended for laboratories that need a repeatable drop setup and a documented, specimen-specific test plan.

Method boundary: match the cell format, bar orientation, drop height and acceptance criteria to the exact procedure. A battery impact test is not a crush test or a forced internal-short-circuit test.
Drop mass9.1 ± 0.1 kg
Adjustable height0–700 mm; published height error ±5 mm
Crossbar diameter15.8 ± 0.1 mm
ControlPLC touchscreen, electric lift and electromagnetic release

What This Equipment Is Designed to Do

Set the impact geometry

Place the cell on the steel impact surface and position the specified crossbar across the specimen. Confirm bar material, length and orientation against the test document.

Control mass and height

Set the height, lift the mass electrically and release it through the electromagnet. The published range accommodates the 610 mm nominal setting used in certain impact procedures.

Observe within an enclosure

The cabinet includes an observation window and rear exhaust fan. The project-specific hazard assessment still determines ventilation, personnel exclusion and emergency response.

Published Technical Parameters

These are values published on the current DERUI product page. Confirm the final equipment drawing, test fixture and supplied documentation in the quotation.

Parameter Published value Quotation or FAT check
Drop mass 9.1 ± 0.1 kg Mass identification and calibration record.
Drop height 0–700 mm adjustable; height error ±5 mm Reference point, physical height verification and repeatability at the intended setting.
Anzeigegenauigkeit 0.1 mm Display increment is not the same as ±5 mm height accuracy.
Crossbar 15.8 ± 0.1 mm diameter Material, length, straightness and orientation for the adopted procedure.
Controller and lift PLC touchscreen; electric lifting Setpoint, release sequence, door-state logic and event record.
Inner and outer panels SUS304 stainless inner sheet 1.0 mm; painted cold-rolled outer sheet 1.0 mm Final assembly construction and protective rating require separate evidence.
Window and door 390 × 360 mm, 10 mm tempered-glass window; single door with lock Do not infer a certified blast-containment rating from glass thickness alone.
Exhaust Φ120 mm outlet with rear fan Facility extraction, discharge route and treatment requirements.
Footprint and utilities W940 × D780 × H1620 mm; AC220 V ±10%, 50 Hz; 2.0 kW; approx. 250 kg Site access, power circuit, ventilation and service clearances.

Define the Impact Procedure Before Testing

Select the exact method

Identify the standard edition, clause, eligible cell type and required sample count.

Prepare the specimen

Specify cell dimensions, state of charge, conditioning and identification in the approved plan.

Check the fixture

Verify bar material and size, cell support, placement and alignment before loading the mass.

Verify the height

Measure from the method-defined reference point and document the actual pre-release position.

Release and observe

Operate the release from a protected position and record event time, temperature and visible response using the agreed instrumentation.

Apply acceptance criteria

Judge the result under the adopted standard and record deviations; the chamber itself does not certify a cell.

UN 38.3 T.6: Capability Versus Test Compliance

UN Manual of Tests and Criteria, subsection 38.3.4.6, describes an impact route for specified cylindrical cells and a separate crush route for other cells. Its impact setup calls for a 9.1 ± 0.1 kg mass, a 15.8 ± 0.1 mm stainless-steel bar and a 61 ± 2.5 cm drop. The published equipment values cover the mass, diameter and adjustable height; bar material and length, guide behavior, specimen scope and the full procedure must be checked in the approved technical agreement.

Important distinction: do not use this gravity-impact machine to represent every UN 38.3 T.6 cell format. Confirm whether your specimen requires the impact route or a separate crush method under the applicable edition.

Safety and Facility Integration

Enclosure is not a rating

The published steel cabinet and tempered observation glass describe physical construction, not a verified thermal-runaway or blast-containment class.

Exhaust needs a route

The Φ120 mm outlet and fan need a site-specific extraction design. Check expected gas, smoke and fire scenarios with the laboratory safety team.

Interlocks need verification

Confirm door interlock, emergency stop, release inhibit, remote observation and post-event access rules in the final configuration and FAT.

Recommended Factory Acceptance Checks

Überprüfen Witness evidence
Mass and bar Measured mass, bar diameter, material and length; traceable instruments.
Height setting Measured drop height at the agreed setting, including the reference point and stated tolerance.
Release path Observed vertical fall, bar alignment, electromagnet release and retrieval sequence.
Control and safeguards PLC display, door-state behavior, release inhibit and emergency-stop action as contracted.
Site interfaces Electrical nameplate, exhaust connection, clearances and maintenance access.
Dokumentation Drawing, manual, wiring, inspection record and calibration scope agreed before shipment.

Häufig gestellte Fragen

Is this a UN 38.3 T.6 impact machine?

Its published mass, bar diameter and height range can support the impact geometry, but method suitability depends on the exact standard edition, eligible cell type, bar specification, guide and witnessed setup. Compliance cannot be concluded from three numbers alone.

Can it test pouch and prismatic cells under the same T.6 impact procedure?

Do not assume so. The UN 38.3 T.6 method distinguishes impact and crush routes by specimen scope. Review the applicable edition and use the correct apparatus for the selected route.

Does 0.1 mm display precision mean 0.1 mm drop-height accuracy?

No. The page separately publishes ±5 mm height error. Confirm the measurement reference and verification method at the intended height.

Does the window make the cabinet explosion-proof?

No certified containment rating has been verified from the published glass and sheet thickness. Request a documented hazard assessment and safety package for the specimen risk.

Are test curves and data export standard?

The current published parameter table confirms a PLC touchscreen, but does not establish the exact recorded channels or export format. Include these requirements in the RFQ.

What should be sent for a quotation?

Send cell format and dimensions, applicable standard/edition, test route, sample count, state of charge, bar/fixture requirement, monitoring channels, facility exhaust and requested acceptance evidence.

Configure the Correct Impact Test Setup

Share your specimen drawing and the exact test clause. DERUI can review fixture geometry, equipment scope and FAT evidence before a configuration is quoted.

Request a technical quotation

Send with your inquiry

  • Cell type, dimensions and sample count
  • Standard edition and test clause
  • Drop height and fixture drawing
  • Monitoring, exhaust and safety requirements
FacebookLinkedInXRedditWhatsApp
Nein. Artikel Details
1 Messbereich 1 - 15 kN (Standard 13 kN)
2 Anzeige des Kraftwerts Touchscreen-Display, Einheiten: kg, N, LB usw.
3 Genauigkeit der Kraftmessung ±1%
4 Prüfmethode Hydraulischer Antrieb. Wenn die Extrusion so lange fortgesetzt wird, bis der tatsächliche Druck erreicht ist, den Druck halten, bis die eingestellte Zeit abgelaufen ist, und dann automatisch den Druck freigeben, um die Extrusion abzuschließen.
5 Extrusionshub 300 mm
6 Haltezeit 0 - 99 s
7 Extrusionskopf Durchmesser 150 mm
8 Effektiver Prüfraum (Breite * Tiefe * Höhe) Ca. 300 * 300 * 450 mm
9 Gehäusematerial Edelstahl-Innengehäuse, hitzebeständig, isolierend, korrosionsbeständig; kaltgewalztes Stahl-Außengehäuse mit Lackbeschichtung
10 Visuelles Beobachtungsfenster 250 * 250 mm, mehrlagiges gehärtetes Glas und Edelstahlgitter
11 Druckentlastungsfenster 200. Das Druckentlastungsventil öffnet sich, um den Druck freizusetzen, wenn die Probe explodiert.
12 Belüftungs- und Beleuchtungssystem Es gibt einen Luftauslass auf der Rückseite des Gehäuses und eine Lampe im Inneren.
13 Geräteabmessungen (Länge * Breite * Höhe) Ca. 700 * 750 * 1700 mm
14 Gerätegewicht Ca. 220 kg
15 Betriebsspannung AC380V, 2KW

1, Was ist eine Batteriekontraktionsprüfkammer?
Eine Batteriekontraktionsprüfkammer ist ein Prüfgerät, das verwendet wird, um die Leistung von Batterien unter Kompression zu bewerten.

2, Was ist der Zweck der Batteriekontraktionsprüfkammer?
Sie wird hauptsächlich verwendet, um die Sicherheit und Zuverlässigkeit von Batterien unter extremen Bedingungen zu testen.

3, Für welche Batterietypen ist die Batteriekontraktionsprüfkammer geeignet?
Sie ist geeignet für verschiedene Batterietypen wie Lithiumbatterien, Blei-Säure-Batterien, Nickel-Metall-Hydrid-Batterien usw.

4, Wie funktioniert die Batteriekontraktionsprüfkammer?
Das hydraulische Antriebssystem übt Druck auf die Batterie aus, um die tatsächliche Situation beim Zerdrücken zu simulieren. Wenn der eingestellte Druck erreicht und bis zum tatsächlichen Druckzustand gehalten wird, wird der Druck für die eingestellte Zeit gehalten und dann automatisch freigegeben, um den Test abzuschließen.

5, Warum wird der Batteriekontraktionstest durchgeführt?
Um die Sicherheit und Stabilität der Batterie beim Zerdrücken zu erkennen, die Leistung der Batterie bei äußeren Kraftimpulsen zu bewerten und potenzielle Sicherheitsrisiken wie Explosion und Feuer während des tatsächlichen Gebrauchs zu verhindern.

6, Welche einzigartigen Funktionen hat die Batteriekontraktionsprüfkammer?
Sie verfügt über automatische Druckhalte- und Freigabefunktionen. Wenn das Quetschen bis zum tatsächlichen Druck fortgesetzt wird, kann sie den Druck für die eingestellte Zeit halten und dann automatisch freigeben. Sie ist mit einem Sichtfenster und einem Druckablassfenster ausgestattet, die die Beobachtung des Testprozesses und die Handhabung von Notfällen erleichtern.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
NachrichtNachricht

Anfrage für ein Angebot