Tầng 1, số 3, đại lộ Shugang, thị trấn Hongmei, thành phố Đông Quan, tỉnh Quảng Đông, Trung Quốc

Nhà sản xuất buồng kiểm tra môi trường 20 nămHơn 3000 khách hàng trên toàn thế giới giao hàng           Email: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Buồng kiểm tra chống nổ nhiệt độ cao thấp ba lớp

The DERUI DR-H201-3 three-layer battery safety climate chamber combines three independently controlled compartments for parallel temperature or temperature-humidity testing. The safety package is engineered around battery chemistry, state of charge, powered interfaces and credible failure scenarios.

Architecture Three independently controlled compartments
Capacity per Layer 80 / 100 / 150 / 225 / 408 L
Temperature Options 0 / -20 / -40 / -70°C to +150°C
Humidity Option 20% to 98% RH; operating envelope to confirm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Relief, detection, exhaust, suppression and interlocks are project-specific
Before Quotation Provide chemistry, SOC, profiles, interfaces, hazards and FAT criteria
An toàn và đáng tin cậy
Chế tạo tốt
Đảm bảo chất lượng
Tùy chỉnh
Tin nhắnWhatsApp
Số điện thoại đường dây nóng 15580327593
  • Chi tiết sản phẩm
  • Thông số kỹ thuật
  • Câu hỏi thường gặp
  • Liên hệ với chúng tôi
Three Independent Battery Test Compartments

DR-H201-3 Three-Layer Battery Safety Climate Chamber

Run three independent temperature or temperature-humidity programmes in one vertical system for battery cells, modules and compact assemblies. Each compartment can be started, stopped and programmed separately to increase laboratory throughput.

Safety boundary: “explosion-proof” is not one universal performance rating. Pressure relief, gas detection, exhaust, fire suppression, reinforced construction and certification scope must be selected from the specimen hazard analysis and verified in the approved design.
ArchitectureThree independently controlled compartments
Capacity per layer80 / 100 / 150 / 225 / 408 L
Published temperature options0 / -20 / -40 / -70°C to +150°C
Humidity option20% đến 98% RH

Where the Three-Layer Design Fits

Parallel battery conditioning

Run three batches, setpoints or programmes without dedicating floor space to three separate cabinets.

Development and QC separation

Keep engineering trials, incoming inspection and routine reliability work operationally independent.

Monitored powered testing

Support test leads and specimen monitoring only after powered heat, failure modes and safety controls are engineered.

Published DR-H201 Three-Layer Model Matrix

Mẫu Dung tích Internal size per compartment
DR-H201-80-3 80 L × 3 500 × 400 × 400 mm
DR-H201-100-3 100 L × 3 400 × 500 × 500 mm
DR-H201-150-3 150 L × 3 500 × 600 × 500 mm
DR-H201-225-3 225 L × 3 500 × 750 × 600 mm
DR-H201-408-3 408 L × 3 600 × 850 × 800 mm
Published-table basis: use this formal model matrix rather than conflicting promotional values. Confirm dimension order and usable clearance on the approved drawing.

Published Environmental Performance

Mục Published value cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Temperature options 0 / -20 / -40 / -70°C to +150°C Select the required configuration per compartment.
Độ đồng đều nhiệt độ ≤2°C, no-load Confirm sensor map, setpoint and simultaneous operation.
Biến động nhiệt độ ±0.5°C, no-load Confirm stabilization and measurement interval.
Humidity option 20% đến 98% RH Request the combined temperature-RH operating chart.
Humidity uniformity / fluctuation +2/-3% RH / ±2% RH Confirm setpoint, load and method.
Heating / cooling 1–3°C/min / 0.7–1°C/min Confirm average definition, span and loaded condition.
Time setting 1–60,000 min Confirm independent programme and record capacity.

Engineer the Safety Package from the Hazard

Define the specimen

State chemistry, format, capacity, quantity, state of charge, mass, electrical energy and intended abuse or non-abuse condition.

Define credible failures

Identify gas, smoke, flame, pressure, electrolyte, fragments and heat that the chamber and facility must address.

Define detection and response

Specify sensors, thresholds, exhaust, power isolation, suppression, alarms, remote monitoring and emergency procedures.

Safety Functions to Confirm in the Quotation

Function Required confirmation
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Relief area, opening pressure, discharge direction and facility clearance.
Gas/smoke detection Target gases, sensor range, alarm thresholds, calibration and interlock matrix.
Forced exhaust Airflow, duct material, discharge point, make-up air and post-event purge.
Fire suppression Agent, concentration/design basis, activation logic and local code approval.
Observation/video Window rating, camera protection, recording and remote-viewing scope.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Specimen supply cut-off, chamber shutdown, emergency stop and fail-safe state.
Chứng nhận Exact product, configuration, certificate number, scope and issuing body.
Quan trọng: a reinforced shell, pressure vent or door chain alone does not prove containment of battery thermal runaway. Acceptance must be tied to a defined hazard scenario and documented test evidence.

Three-Layer Chamber Reference Image

DERUI DR-H201-3 three-layer battery explosion-proof temperature test chamber

DERUI three-layer battery climate chamber reference image. Final compartment sizes, interfaces and safety package follow the approved risk assessment and technical agreement.

Standards Must Be Mapped to the Exact Procedure

Reference cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Boundary
UN 38.3 Lithium battery transport tests Not every T.1–T.8 procedure is performed in this climate chamber.
IEC 62619 Industrial secondary lithium cell/battery safety Confirm applicable clause, specimen and required equipment.
UL 1642 Lithium cell safety evaluation Method-specific fixtures and abuse equipment may be separate.
GB/T 31485 or successor/customer requirement Battery safety test reference Confirm current applicable document, procedure and acceptance criteria.

RFQ and Safety FAT Checklist

Topic Information to provide or verify
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Chemistry, format, capacity, SOC, quantity, mass and energy.
Three profiles Temperature/RH, ramp, dwell, cycle and powered heat per layer.
Interfaces Charge/discharge, measurement, gas, video, ports and data.
Hazards Gas, smoke, flame, pressure, electrolyte and fragment scenarios.
Facility Power, exhaust, drainage, fire system, clearance and emergency response.
FAT Climate mapping, simultaneous operation, alarms, interlocks and safe-state tests.

Câu hỏi thường gặp

Are all three compartments independently controlled?

The page states independent operation. Confirm separate sensors, programmes, records, thermal systems and safety interlocks in the final configuration.

What is the published standard temperature range?

The formal parameter table lists options from 0/-20/-40/-70°C to +150°C. Any extension requires a separately approved configuration.

Does “explosion-proof” mean thermal-runaway containment is guaranteed?

No. The term must be supported by a defined hazard scenario, engineered protections, acceptance tests and any applicable certification.

Are gas detection and fire suppression standard?

The page describes them as available safety functions/options, but the exact standard bill of materials is not established. Confirm each item explicitly.

Can it perform all UN 38.3 tests?

No. UN 38.3 includes different procedures requiring different equipment. Map the applicable procedure to the correct chamber or tester.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send battery chemistry, format, capacity, SOC, quantity, three profiles, electrical interfaces, hazards, facility controls and FAT criteria.

Configure the Three Compartments and Safety Matrix Together

Send the specimen data, three environmental profiles, powered interfaces and hazard analysis. DERUI can confirm capacities, climate performance, detection, exhaust, suppression, interlocks and FAT scope.

Request a Battery Safety Chamber Review

FacebookLinkedInXRedditWhatsApp
Mẫu DR-H201 -80- 3 DR-H201 -100 - 3 DR-H201 -150 - 3 DR-H201 -225 - 3 DR-H201 -408 - 3
Thể tích lớp trên (dưới) 80L*3 100L*3 150L*3 225L*3 408L*3
Kích thước lớp trên (dưới) 500 * 400 * 400 400 * 500 * 500 500 * 600 * 500 500 * 750 * 600 600 * 850 * 800
chỉ số Phạm vi nhiệt độ 0℃~150℃ -20℃~150℃ -40℃~150℃ -70℃~150℃ 
Độ đồng đều nhiệt độ ≤2℃(Thời gian không tải)
Biến động nhiệt độ ±0.5℃(Thời gian không tải)
Phạm vi độ ẩm 20%~98% RH
Độ đồng đều độ ẩm +2% -3% RH
Biến động độ ẩm ±2%
Tốc độ gia nhiệt 1.0~3.0℃/phút
Tốc độ làm mát 0.7~1.0℃/phút
Phạm vi cài đặt thời gian 1~60000M
Lỗ thử nghiệm Lắp đặt ở phía bên trái của máy để dây nguồn thử nghiệm bên ngoài hoặc cáp tín hiệu
Cửa sổ quan sát 210×275mmHOẶC 395×395mm(Tầm nhìn hiệu quả)

H: Một buồng thử nghiệm chống nổ nhiệt độ cao và thấp ba lớp là gì?
Đáp: Đây là một buồng thử nghiệm môi trường chuyên dụng với ba khoang điều khiển độc lập, được thiết kế để an toàn thử nghiệm pin hoặc vật liệu nguy hiểm qua chu kỳ nhiệt độ cực đoan trong khi ngăn chặn các vụ nổ bên trong thông qua hệ thống giảm áp tích hợp, bộ chặn lửa và hệ thống phát hiện khí.

H: Buồng thử nghiệm chống nổ ba lớp cải thiện hiệu quả thử nghiệm như thế nào?
Đáp: Ba khoang độc lập cho phép chạy đồng thời các hồ sơ thử nghiệm khác nhau—chẳng hạn như chu kỳ nhiệt độ khác nhau hoặc tiêu chuẩn pin—mà không gây nhiễu lẫn nhau, giảm đáng kể thời gian phòng thí nghiệm và tăng năng suất.

H: Các tính năng an toàn quan trọng trong buồng thử nghiệm pin chống nổ là gì?
Đáp: Các tính năng chính bao gồm lỗ thoát khí giảm áp tự động, bộ chặn lửa, hệ thống phát hiện khí cháy theo thời gian thực, tường buồng được gia cố và hệ thống chữa cháy tùy chọn (ví dụ: CO2 hoặc Novec 1230) để đảm bảo an toàn trong các sự cố nhiệt độ quá cao.

H: Tiêu chuẩn thử nghiệm pin nào có thể đáp ứng bằng buồng chống nổ ba vùng?
Đáp: Nó tuân thủ các tiêu chuẩn quốc tế chính, bao gồm UN38.3, IEC 62619, GB/T 31485, UL 1642 và SAND 2005-3123, bao gồm các thử nghiệm an toàn cho tế bào lithium-ion, module và bộ sạc.

H: Tôi có thể tùy chỉnh phạm vi nhiệt độ trong buồng thử nghiệm chống nổ ba lớp không?
Đáp: Có. Trong khi phạm vi tiêu chuẩn thường từ -70°C đến +180°C, các nhà sản xuất như Derui thường cung cấp phạm vi tùy chỉnh để đáp ứng yêu cầu thử nghiệm cụ thể cho vật liệu hoặc hóa học pin.

H: Sự khác biệt giữa buồng thử nghiệm chống nổ một vùng và ba lớp là gì?
Đáp: Buồng một vùng có không gian thử nghiệm thống nhất với điều kiện đồng nhất, trong khi buồng ba lớp cung cấp ba khoang riêng biệt, điều khiển độc lập, cho phép thử nghiệm song song các mẫu hoặc điều kiện khác nhau trong cùng một thiết bị.

H: Làm thế nào để duy trì sự đồng đều nhiệt độ trong từng lớp của buồng?
Đáp: Mỗi khoang sử dụng cảm biến hiệu chỉnh riêng, hệ thống luồng khí riêng biệt và bộ điều khiển PID chính xác cao để đảm bảo độ đồng đều nhiệt độ trong phạm vi ±2°C và dao động trong phạm vi ±0.5°C trên vùng thử nghiệm.

H: Các ngành công nghiệp nào thường sử dụng buồng nhiệt chu kỳ chống nổ ba lớp?
A: Chúng rất cần thiết trong sản xuất pin xe điện (EV), thử nghiệm hệ thống lưu trữ năng lượng (ESS), hàng không vũ trụ, điện tử tiêu dùng và bất kỳ lĩnh vực nào yêu cầu xác nhận an toàn nhiệt nghiêm ngặt của các vật liệu nguy hiểm.

9. H: Các tính năng tùy chọn nào có sẵn cho thử nghiệm pin nâng cao?
A: Các tùy chọn bao gồm kiểm soát độ ẩm (20–98% RH), làm lạnh nước, giám sát video nội bộ, giao diện kẹp pin cho thử nghiệm quá tải/ xả, và thiết kế sẵn sàng tự động hóa với tích hợp robot tay.

10. H: Làm thế nào để tôi chọn nhà sản xuất đáng tin cậy cho buồng thử nghiệm chống nổ?
A: Tìm kiếm kinh nghiệm đã được chứng minh trong thiết kế chống nổ, tuân thủ các chứng nhận quốc tế (CE, ATEX/IECEx tùy chọn), hỗ trợ kỹ thuật minh bạch và mạng lưới dịch vụ toàn cầu. Các nhà cung cấp uy tín như Derui thường cung cấp báo cáo hiệu chuẩn đầy đủ và hỗ trợ kỹ thuật tùy chỉnh.

WhatsAppWhatsApp