Chambre d'essai étanche à haute et basse température à trois couches

Product overview

Organize three battery-conditioning programmes in separate stacked compartments. Specify the environmental profile, powered interfaces and hazard response for each compartment before selecting the complete protection package.

Article Spécification
Series / architecture DR-H201-3 / three compartments
Capacity per compartment 80 / 100 / 150 / 225 / 408 L
Temperature options 0 / −20 / −40 / −70°C to +150°C
Humidity option 20% to 98% RH; selected configuration applies
Protection scope Defined by specimen hazards and the approved protection matrix
Sûr et fiable
bien fabriqué
Assurance qualité
personnalisation
MessageWhatsApp
Numéro de hotline 15580327593
  • Détails du produit
  • Paramètres techniques
  • FAQ
  • Contactez-nous

DR-H201-3 series

Chambre d'essai étanche à haute et basse température à trois couches

Organize three battery-conditioning programmes in separate stacked compartments. Specify the environmental profile, powered interfaces and hazard response for each compartment before selecting the complete protection package.

DR-H201-3 series

Where the Three-Layer Design Fits

Parallel battery conditioning

Run three batches, setpoints or programmes without dedicating floor space to three separate cabinets.

Development and QC separation

Keep engineering trials, incoming inspection and routine reliability work operationally independent.

Monitored powered testing

Support test leads and specimen monitoring only after powered heat, failure modes and safety controls are engineered.

DR-H201-3 series

DR-H201 Three-Layer Model Matrix

Modèle Volume Internal size per compartment
DR-H201-80-3 80 L × 3 500 × 400 × 400 mm
DR-H201-100-3 100 L × 3 400 × 500 × 500 mm
DR-H201-150-3 150 L × 3 500 × 600 × 500 mm
DR-H201-225-3 225 L × 3 500 × 750 × 600 mm
DR-H201-408-3 408 L × 3 600 × 850 × 800 mm
Configuration: use this formal model matrix rather than conflicting promotional values. Confirm dimension order and usable clearance on the approved drawing.

DR-H201-3 series

Environmental Performance

Article Spécification cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Temperature options 0 / -20 / -40 / -70°C to +150°C Select the required configuration per compartment.
Uniformité de température ≤2°C, no-load Confirm sensor map, setpoint and simultaneous operation.
Fluctuation de température ±0.5°C, no-load Confirm stabilization and measurement interval.
Humidity option 20% à 98% HR Request the combined temperature-RH operating chart.
Humidity uniformity / fluctuation +2/-3% RH / ±2% RH Confirm setpoint, load and method.
Heating / cooling 1–3°C/min / 0.7–1°C/min Confirm average definition, span and loaded condition.
Time setting 1–60,000 min Confirm independent programme and record capacity.

DR-H201-3 series

Engineer the Safety Package from the Hazard

Define the specimen

State chemistry, format, capacity, quantity, state of charge, mass, electrical energy and intended abuse or non-abuse condition.

Define credible failures

Identify gas, smoke, flame, pressure, electrolyte, fragments and heat that the chamber and facility must address.

Define detection and response

Specify sensors, thresholds, exhaust, power isolation, suppression, alarms, remote monitoring and emergency procedures.

DR-H201-3 series

Safety Functions to Confirm in the Quotation

Function Required confirmation
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Relief area, opening pressure, discharge direction and facility clearance.
Gas/smoke detection Target gases, sensor range, alarm thresholds, calibration and interlock matrix.
Forced exhaust Airflow, duct material, discharge point, make-up air and post-event purge.
Fire suppression Agent, concentration/design basis, activation logic and local code approval.
Observation/video Window rating, camera protection, recording and remote-viewing scope.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Specimen supply cut-off, chamber shutdown, emergency stop and fail-safe state.
Certification Exact product, configuration, certificate number, scope and issuing body.
Important : a reinforced shell, pressure vent or door chain alone does not prove containment of battery thermal runaway. Acceptance must be tied to a defined hazard scenario and documented test evidence.

DR-H201-3 series

Three-Layer Chamber Product View

DERUI DR-H201-3 three-layer battery explosion-proof temperature test chamber

DERUI three-layer battery climate chamber reference image. Final compartment sizes, interfaces and safety package follow the approved risk assessment and technical agreement.

DR-H201-3 series

Standards Must Be Mapped to the Exact Procedure

Reference cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Boundary
UN 38.3 Lithium battery transport tests Not every T.1–T.8 procedure is performed in this climate chamber.
IEC 62619 Industrial secondary lithium cell/battery safety Confirm applicable clause, specimen and required equipment.
UL 1642 Lithium cell safety evaluation Method-specific fixtures and abuse equipment may be separate.
GB/T 31485 or successor/customer requirement Battery safety test reference Confirm current applicable document, procedure and acceptance criteria.

DR-H201-3 series

RFQ and Safety FAT Checklist

Topic Information to provide or verify
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Chemistry, format, capacity, SOC, quantity, mass and energy.
Three profiles Temperature/RH, ramp, dwell, cycle and powered heat per layer.
Interfaces Charge/discharge, measurement, gas, video, ports and data.
Hazards Gas, smoke, flame, pressure, electrolyte and fragment scenarios.
Facility Power, exhaust, drainage, fire system, clearance and emergency response.
FAT Climate mapping, simultaneous operation, alarms, interlocks and safe-state tests.

DR-H201-3 series

Compare the proposed equipment against the real test

Purchasing decision

Purchase the three-compartment system against a layer-by-layer schedule. Identify the specimen energy, operating state, heat load and environmental programme in every compartment. A protection item included for one application is not automatically suitable for another, and the product name alone does not establish an explosion-containment or hazardous-area certification.

Application planning

For parallel cell conditioning, define how an abnormal temperature or detector signal in one compartment affects the other two. The review should identify which electrical sources are isolated, which environmental controls stop, what alarms remain active and how exhaust is handled. State the intended normal operation and credible failure scenarios so the chamber and facility responses can be reviewed together.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Request the compartment layout, protection configuration and cause-and-effect matrix. During acceptance, demonstrate the agreed sensor inputs, alarm indications and safe-state actions using an approved functional protocol. Such checks verify the controls; they are not destructive proof of containment. Any battery-event test or certification requirement needs its own defined scope and supporting documentation.

DR-H201-3 series

Choose the equipment for the intended application

Request a DR-H201-3 series configuration review

Send the specimen drawing, quantity, mass, operating profile, powered heat, interfaces and destination utilities. Include the acceptance criteria and required test records so the proposed configuration can be reviewed against the actual test.

Discuss My Test Requirements

Passez en revue DERUI company information et qualification documents. Confirm which supplied documents and configuration details apply to the equipment in your quotation.

FacebookLinkedInXRedditWhatsApp

Paramètres techniques

Modèle DR-H201 -80- 3 DR-H201 -100 - 3 DR-H201 -150 - 3 DR-H201 -225 - 3 DR-H201 -408 - 3
Volume de la couche supérieure (inférieure) 80L*3 100L*3 150L*3 225L*3 408L*3
Dimensions de la couche supérieure (inférieure) 500 * 400 * 400 400 * 500 * 500 500 * 600 * 500 500 * 750 * 600 600 * 850 * 800
index Plage de température 0℃~150℃ -20℃~150℃ -40℃~150℃ -70℃~150℃ 
Uniformité de température ≤2℃ (temps sans charge)
Fluctuation de température ±0,5℃ (temps sans charge)
Plage d'humidité 20%~98% HR
Uniformité de l'humidité +2% -3% HR
Fluctuation d'humidité ±2%
Vitesse de chauffage 1,0~3,0℃/min
Vitesse de refroidissement 0,7~1,0℃/min
Plage de réglage du temps 1~60000M
Trou de test Il est installé sur le côté gauche de la machine pour le cordon d'alimentation externe ou le câble de signal
Fenêtre d'observation 210×275mmOU395×395mm (Horizon efficace)

Questions before ordering

Are all three compartments independently controlled?

Independent operation must be confirmed in the selected configuration. Confirm separate sensors, programmes, records, thermal systems and safety interlocks in the final configuration.

What is the standard temperature range?

The formal parameter table lists options from 0/-20/-40/-70°C to +150°C. Any extension requires a separately approved configuration.

Does “explosion-proof” mean thermal-runaway containment is guaranteed?

No. The term must be supported by a defined hazard scenario, engineered protections, acceptance tests and any applicable certification.

Are gas detection and fire suppression standard?

The page describes them as available protective functions. List the selected items and operating conditions in the equipment supply schedule.

Can it perform all UN 38.3 tests?

No. UN 38.3 includes different procedures requiring different equipment. Map the applicable procedure to the correct chamber or tester.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send battery chemistry, format, capacity, SOC, quantity, three profiles, electrical interfaces, hazards, facility controls and FAT criteria.

How should we compare quotations for this configuration?

Purchase the three-compartment system against a layer-by-layer schedule. Identify the specimen energy, operating state, heat load and environmental programme in every compartment. A protection item included for one application is not automatically suitable for another, and the product name alone does not establish an explosion-containment or hazardous-area certification.

What evidence should be reviewed before approving the order?

Request the compartment layout, protection configuration and cause-and-effect matrix. During acceptance, demonstrate the agreed sensor inputs, alarm indications and safe-state actions using an approved functional protocol. Such checks verify the controls; they are not destructive proof of containment. Any battery-event test or certification requirement needs its own defined scope and supporting documentation.