Câmara de Teste de Explosão à Prova de Alta Baixa Temperatura de Três Camadas

A DERUI DR-H201-3 three-layer battery safety climate chamber combines three independently controlled compartments for parallel temperature or temperature-humidity testing. The safety package is engineered around battery chemistry, state of charge, powered interfaces and credible failure scenarios.

Architecture Three independently controlled compartments
Capacity per Layer 80 / 100 / 150 / 225 / 408 L
Temperature Options 0 / -20 / -40 / -70°C to +150°C
Humidity Option 20% to 98% RH; operating envelope to confirm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Relief, detection, exhaust, suppression and interlocks are project-specific
Before Quotation Provide chemistry, SOC, profiles, interfaces, hazards and FAT criteria
Seguro e fiável
bem construído
Garantia de qualidade
personalização
MensagemWhatsApp
Número de Linha Direta 15580327593
  • Detalhes do Produto
  • Parâmetros técnicos
  • Perguntas Frequentes
  • Contacte-nos
Three Independent Battery Test Compartments

DR-H201-3 Three-Layer Battery Safety Climate Chamber

Run three independent temperature or temperature-humidity programmes in one vertical system for battery cells, modules and compact assemblies. Each compartment can be started, stopped and programmed separately to increase laboratory throughput.

Safety boundary: “explosion-proof” is not one universal performance rating. Pressure relief, gas detection, exhaust, fire suppression, reinforced construction and certification scope must be selected from the specimen hazard analysis and verified in the approved design.
ArchitectureThree independently controlled compartments
Capacity per layer80 / 100 / 150 / 225 / 408 L
Published temperature options0 / -20 / -40 / -70°C to +150°C
Humidity option20% a 98% RH

Where the Three-Layer Design Fits

Parallel battery conditioning

Run three batches, setpoints or programmes without dedicating floor space to three separate cabinets.

Development and QC separation

Keep engineering trials, incoming inspection and routine reliability work operationally independent.

Monitored powered testing

Support test leads and specimen monitoring only after powered heat, failure modes and safety controls are engineered.

Published DR-H201 Three-Layer Model Matrix

Modelo Volume Internal size per compartment
DR-H201-80-3 80 L × 3 500 × 400 × 400 mm
DR-H201-100-3 100 L × 3 400 × 500 × 500 mm
DR-H201-150-3 150 L × 3 500 × 600 × 500 mm
DR-H201-225-3 225 L × 3 500 × 750 × 600 mm
DR-H201-408-3 408 L × 3 600 × 850 × 800 mm
Published-table basis: use this formal model matrix rather than conflicting promotional values. Confirm dimension order and usable clearance on the approved drawing.

Published Environmental Performance

Item Published value cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Temperature options 0 / -20 / -40 / -70°C to +150°C Select the required configuration per compartment.
Uniformidade de temperatura ≤2°C, no-load Confirm sensor map, setpoint and simultaneous operation.
Variação de temperatura ±0.5°C, no-load Confirm stabilization and measurement interval.
Humidity option 20% a 98% RH Request the combined temperature-RH operating chart.
Humidity uniformity / fluctuation +2/-3% RH / ±2% RH Confirm setpoint, load and method.
Heating / cooling 1–3°C/min / 0.7–1°C/min Confirm average definition, span and loaded condition.
Time setting 1–60,000 min Confirm independent programme and record capacity.

Engineer the Safety Package from the Hazard

Define the specimen

State chemistry, format, capacity, quantity, state of charge, mass, electrical energy and intended abuse or non-abuse condition.

Define credible failures

Identify gas, smoke, flame, pressure, electrolyte, fragments and heat that the chamber and facility must address.

Define detection and response

Specify sensors, thresholds, exhaust, power isolation, suppression, alarms, remote monitoring and emergency procedures.

Safety Functions to Confirm in the Quotation

Function Required confirmation
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Relief area, opening pressure, discharge direction and facility clearance.
Gas/smoke detection Target gases, sensor range, alarm thresholds, calibration and interlock matrix.
Forced exhaust Airflow, duct material, discharge point, make-up air and post-event purge.
Fire suppression Agent, concentration/design basis, activation logic and local code approval.
Observation/video Window rating, camera protection, recording and remote-viewing scope.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Specimen supply cut-off, chamber shutdown, emergency stop and fail-safe state.
Certificação Exact product, configuration, certificate number, scope and issuing body.
Importante: a reinforced shell, pressure vent or door chain alone does not prove containment of battery thermal runaway. Acceptance must be tied to a defined hazard scenario and documented test evidence.

Three-Layer Chamber Reference Image

DERUI DR-H201-3 three-layer battery explosion-proof temperature test chamber

DERUI three-layer battery climate chamber reference image. Final compartment sizes, interfaces and safety package follow the approved risk assessment and technical agreement.

Standards Must Be Mapped to the Exact Procedure

Reference cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Boundary
UN 38.3 Lithium battery transport tests Not every T.1–T.8 procedure is performed in this climate chamber.
IEC 62619 Industrial secondary lithium cell/battery safety Confirm applicable clause, specimen and required equipment.
UL 1642 Lithium cell safety evaluation Method-specific fixtures and abuse equipment may be separate.
GB/T 31485 or successor/customer requirement Battery safety test reference Confirm current applicable document, procedure and acceptance criteria.

RFQ and Safety FAT Checklist

Topic Information to provide or verify
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Chemistry, format, capacity, SOC, quantity, mass and energy.
Three profiles Temperature/RH, ramp, dwell, cycle and powered heat per layer.
Interfaces Charge/discharge, measurement, gas, video, ports and data.
Hazards Gas, smoke, flame, pressure, electrolyte and fragment scenarios.
Facility Power, exhaust, drainage, fire system, clearance and emergency response.
FAT Climate mapping, simultaneous operation, alarms, interlocks and safe-state tests.

Perguntas Frequentes

Are all three compartments independently controlled?

The page states independent operation. Confirm separate sensors, programmes, records, thermal systems and safety interlocks in the final configuration.

What is the published standard temperature range?

The formal parameter table lists options from 0/-20/-40/-70°C to +150°C. Any extension requires a separately approved configuration.

Does “explosion-proof” mean thermal-runaway containment is guaranteed?

No. The term must be supported by a defined hazard scenario, engineered protections, acceptance tests and any applicable certification.

Are gas detection and fire suppression standard?

The page describes them as available safety functions/options, but the exact standard bill of materials is not established. Confirm each item explicitly.

Can it perform all UN 38.3 tests?

No. UN 38.3 includes different procedures requiring different equipment. Map the applicable procedure to the correct chamber or tester.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send battery chemistry, format, capacity, SOC, quantity, three profiles, electrical interfaces, hazards, facility controls and FAT criteria.

Configure the Three Compartments and Safety Matrix Together

Send the specimen data, three environmental profiles, powered interfaces and hazard analysis. DERUI can confirm capacities, climate performance, detection, exhaust, suppression, interlocks and FAT scope.

Request a Battery Safety Chamber Review

FacebookLinkedInXRedditWhatsApp
Modelo DR-H201 -80- 3 DR- H201 -100 - 3 DR- H201 -150 - 3 DR- H201 -225 - 3 DR- H201 -408 - 3
Volume da camada superior (inferior) 80L*3 100L*3 150L*3 225L*3 408L*3
Dimensões da camada superior (inferior) 500 * 400 * 400 400 * 500 * 500 500 * 600 * 500 500 * 750 * 600 600 * 850 * 800
índice Faixa de temperatura 0℃~150℃ -20℃~150℃ -40℃~150℃ -70℃~150℃ 
Uniformidade de temperatura ≤2℃(Tempo sem carga)
Variação de temperatura ±0.5℃(Tempo sem carga)
Faixa de humidade 20%~98% HR
Uniformidade de humidade +2% -3% HR
Variação de humidade ±2%
Taxa de aquecimento 1.0~3.0℃/min
Taxa de arrefecimento 0.7~1.0℃/min
Faixa de configuração de tempo 1~60000M
Orifício de teste Está instalado no lado esquerdo da máquina para o cabo de alimentação de teste externo ou cabo de sinal
Janela de observação 210×275mm OU 395×395mm (Horizonte efetivo)

1. P: O que é uma Câmara de Testes de Explosão de Alta e Baixa Temperatura de Três Camadas?
R: É uma câmara de testes ambientais especializada com três compartimentos controlados independentemente, projetada para submeter com segurança baterias ou materiais perigosos a ciclos extremos de temperatura, prevenindo explosões internas através de sistemas de alívio de pressão, arrestores de chama e sistemas de deteção de gases.

2. P: Como uma câmara de teste à prova de explosões de três camadas melhora a eficiência dos testes?
R: Os seus três compartimentos independentes permitem a execução simultânea de diferentes perfis de teste — como ciclos de temperatura variados ou padrões de baterias — sem interferência cruzada, reduzindo significativamente o tempo de laboratório e aumentando a capacidade de produção.

3. P: Quais são as características de segurança críticas numa câmara de teste de baterias à prova de explosões?
R: Características principais incluem sistemas automáticos de alívio de pressão, arrestores de chama, deteção de gases combustíveis em tempo real, paredes reforçadas da câmara e sistemas opcionais de supressão de incêndios (por exemplo, CO2 ou Novec 1230) para garantir a contenção segura de eventos de fuga térmica.

4. P: Quais os padrões de teste de baterias que podem ser atendidos usando uma câmara de explosão de três zonas?
R: Está em conformidade com os principais padrões internacionais, incluindo UN38.3, IEC 62619, GB/T 31485, UL 1642 e SAND 2005-3123, abrangendo testes de segurança para células, módulos e packs de íons de lítio.

5. P: Posso personalizar a faixa de temperatura numa câmara de teste à prova de explosões de três camadas?
R: Sim. Embora as faixas padrão normalmente variem de -70°C a +180°C, fabricantes como a Derui frequentemente oferecem faixas personalizáveis para atender a requisitos específicos de testes de materiais ou químicas de baterias.

6. P: Qual é a diferença entre uma câmara de teste à prova de explosões de uma única zona e uma de três camadas?
R: Uma câmara de uma única zona possui um espaço de teste unificado com condições uniformes, enquanto uma câmara de três camadas oferece três compartimentos separados, controlados de forma independente, permitindo testes paralelos de diferentes amostras ou condições numa única unidade.

7. P: Como é mantida a uniformidade de temperatura em cada camada da câmara?
R: Cada compartimento utiliza sensores calibrados individualmente, sistemas de fluxo de ar dedicados e controladores PID de alta precisão para garantir uma uniformidade de temperatura dentro de ±2°C e flutuações dentro de ±0,5°C na zona de teste.

8. P: Quais indústrias utilizam frequentemente câmaras de ciclo térmico à prova de explosões de três camadas?
R: São essenciais na fabricação de baterias de veículos elétricos (VE), testes de sistemas de armazenamento de energia (SAE), aeroespacial, eletrónica de consumo e em qualquer campo que exija validação rigorosa de segurança térmica de materiais perigosos.

9. P: Quais funcionalidades opcionais estão disponíveis para testes avançados de baterias?
R: Opções incluem controlo de humidade (20–98% HR), refrigeração por água, monitorização de vídeo interna, interfaces para fixação de baterias para testes de sobrecarga/descarga, e designs prontos para automação com integração de braço robótico.

10. P: Como escolher um fabricante fiável para uma câmara de teste à prova de explosões?
R: Procure por experiência comprovada em designs à prova de explosões, conformidade com certificações internacionais (CE, ATEX/IECEx opcional), suporte técnico transparente e uma rede de serviço global. Fornecedores estabelecidos como a Derui frequentemente fornecem relatórios de calibração completos e suporte de engenharia personalizado.