Buồng thử nghiệm kiểm soát nhiệt độ hai lớp

The DERUI double-layer temperature and humidity test chamber combines two independently controlled test zones in one vertical footprint. Run different profiles simultaneously to increase laboratory throughput while keeping specimen batches and environmental conditions separate.

Control Independent upper and lower controllers with separate start/stop
Capacity per Layer 80 / 100 / 150 / 225 / 408 L
Temperature Options 0 / -20 / -40 / -70°C to +150°C
Phạm vi độ ẩm 20% to 98% RH; request the combined operating chart
Core Benefit Two simultaneous tests with less floor space than separate cabinets
Before Quotation Confirm both profiles, loads, control architecture, utilities and FAT
An toàn và đáng tin cậy
Chế tạo tốt
Đảm bảo chất lượng
Tùy chỉnh
Tin nhắnWhatsApp
Số điện thoại đường dây nóng 15580327593
  • Chi tiết sản phẩm
  • Thông số kỹ thuật
  • Câu hỏi thường gặp
  • Liên hệ với chúng tôi
Two Independent Test Zones · One Footprint

Double-Layer Temperature and Humidity Test Chamber

Run two different environmental profiles at the same time without installing two separate cabinets. Each upper and lower chamber has its own controller and independent start/stop operation for parallel R&D, verification and quality-control testing.

Independent control must be specified clearly: confirm whether each layer has fully independent refrigeration, heating, humidification, sensors, data records and safety limits in the approved configuration—not only separate display screens.
Control architectureTwo independently operated chambers
Published capacity per layer80 / 100 / 150 / 225 / 408 L
Temperature options0 / -20 / -40 / -70°C to +150°C
Phạm vi độ ẩm20% đến 98% RH

Why Use a Double-Layer Chamber?

Two simultaneous profiles

Run different setpoints, programmes or specimen groups in the upper and lower zones during the same shift.

Higher laboratory throughput

Increase available test capacity without allocating the floor area required for two standalone chambers.

Separation of test work

Keep development and routine QC, different batches or different temperature-humidity conditions operationally separate.

Published DR-H201 Double-Layer Model Matrix

Mẫu Volume per layer Internal size per layer
DR-H201-80-2 80 L 500 × 400 × 400 mm
DR-H201-100-2 100 L 400 × 500 × 500 mm
DR-H201-150-2 150 L 500 × 600 × 500 mm
DR-H201-225-2 cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 500 × 750 × 600 mm
DR-H201-408-2 cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 600 × 850 × 800 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits the source lists three dimensions but does not consistently establish the W × D × H order. Confirm orientation and usable clearance on the approved drawing.

Published Environmental Performance

Mục Published value cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Temperature range options 0 / -20 / -40 / -70°C to +150°C Select the required low-temperature configuration for both layers.
Độ đồng đều nhiệt độ ≤2°C, no-load Confirm sensor map, setpoint and working-space definition.
Biến động nhiệt độ ±0.5°C, no-load Confirm stabilized condition and measurement interval.
Phạm vi độ ẩm 20% đến 98% RH Request the valid combined temperature-RH operating envelope.
Humidity uniformity / fluctuation +2/-3% RH / ±2% RH Confirm setpoint, load and measurement method.
Heating / cooling 1–3°C/min / 0.7–1°C/min Confirm average definition, temperature span and loaded performance.
Time setting 1–60,000 min Confirm programme steps, cycles and independent records.

Confirm True Independence Between the Two Layers

Control independence

Verify separate programmes, sensors, alarms, start/stop control and data files for upper and lower chambers.

Thermal independence

Define simultaneous worst-case profiles and confirm one layer’s load does not invalidate the other layer’s performance.

Utility independence

Confirm shared versus separate refrigeration, humidification, water, drainage and electrical protection architecture.

Construction and Daily-Use Features

SUS304 workspaces

Brushed stainless-steel chambers, silicone seals and locking doors support repeated climatic exposure.

Adjustable sample racks

Rack height can be adapted to the specimen, but loading must preserve supply and return airflow.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Heated observation windows and selectable 50 or 100 mm cable ports support monitoring and powered tests.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Centrifugal blowers, adjustable deflectors and supply/return ducts distribute conditioned air in each zone.

Humidity system

Independent humidification and evaporator-based dehumidification are stated; confirm water and control architecture per layer.

Compact vertical layout

Stacked zones increase throughput per floor area, but room height, service clearance and transport access must be checked.

Match Each Layer to Its Test Method

Reference Sử dụng điển hình cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
IEC 60068-2-1 Cold testing Test type, setpoint, stabilization, duration and specimen operation.
IEC 60068-2-2 Dry heat Heat-dissipating state, airflow and measurement points.
IEC 60068-2-78 Steady damp heat Temperature, RH, duration, load and evaluation.
IEC 60068-2-30 Cyclic damp heat Cycle, transitions, condensation and recovery.

RFQ and Dual-Zone FAT Checklist

Topic Information to provide or verify
Layer A profile Setpoints, ramps, dwells, cycles, load and powered heat.
Layer B profile Setpoints, ramps, dwells, cycles, load and powered heat.
Simultaneous operation Worst-case combined condition and required performance in both layers.
Interfaces Ports, power, signals, thermocouples, communications and data files.
Tiện ích Voltage, current, water, drain, heat rejection and service access.
FAT Separate sensor maps, simultaneous profiles, alarms, records and acceptance limits.

Câu hỏi thường gặp

Can the two layers run different test conditions?

Yes. The page states that each cabinet has its own controller and can start or stop independently. Confirm the full thermal and utility architecture in the quotation.

Is the listed capacity total volume?

The table describes the volume of the upper or lower layer. For example, the 150 L model provides two nominal 150 L workspaces.

Can one layer run temperature-only while the other runs humidity?

This should be possible only when the selected configuration provides independent humidity and refrigeration control. State the simultaneous profiles for confirmation.

Does 20–98% RH apply at every temperature?

No rectangular envelope should be assumed. Request the combined temperature-RH chart for the selected configuration.

Can powered specimens be tested?

Yes when port, cable, specimen heat and safety requirements are included in the engineering calculation.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send both layer profiles, specimen drawings, quantities, mass, powered heat, interfaces, utilities and simultaneous FAT requirements.

Configure Both Test Zones Before Quotation

Send the upper- and lower-layer profiles separately. DERUI can confirm capacity, temperature options, humidity envelope, interfaces, utilities and simultaneous acceptance testing.

Request a Double-Layer Chamber Review

FacebookLinkedInXRedditWhatsApp
Mẫu DR-H201 -80- 2 DR-H201 -100- 2 DR-H201 -150- 2 DR-H201 -225- 2 DR-H201 -408- 2
Thể tích lớp trên (dưới) 80L 100L 150L 225L 408L
Kích thước lớp trên (dưới) 500 * 400 * 400 400 * 500 * 500 500 * 600 * 500 500 * 750 * 600 600 * 850 * 800
chỉ số Phạm vi nhiệt độ 0℃~150℃ -20℃~150℃ -40℃~150℃ -70℃~150℃ 
Độ đồng đều nhiệt độ ≤2℃(Thời gian không tải)
Biến động nhiệt độ ±0.5℃(Thời gian không tải)
Phạm vi độ ẩm 20%~98% RH
Độ đồng đều độ ẩm +2% -3% RH
Biến động độ ẩm ±2%
Tốc độ gia nhiệt 1.0~3.0℃/phút
Tốc độ làm mát 0.7~1.0℃/phút
Phạm vi cài đặt thời gian 1~60000M
Lỗ thử nghiệm Lắp đặt ở phía bên trái của máy để dây nguồn thử nghiệm bên ngoài hoặc cáp tín hiệu
Cửa sổ quan sát 210×275mmHOẶC 395×395mm(Tầm nhìn hiệu quả)
 
 
 
 
 

1、Các dịp nào phù hợp để sử dụng buồng kiểm tra nhiệt độ hai lớp?
Phù hợp cho các dịp thử nghiệm khác nhau như kiểm tra vật liệu, kiểm tra sản phẩm và kiểm soát chất lượng.

2, Phạm vi nhiệt độ của thiết bị là gì?
Buồng thử nghiệm này có ba phạm vi nhiệt độ: -20°C đến +150°C, -40°C đến +150°C, và -70°C đến +150°C, phù hợp với các yêu cầu thử nghiệm khác nhau.

3, Làm thế nào để thiết lập các tham số thử nghiệm?
Các tham số như nhiệt độ và thời gian có thể dễ dàng thiết lập qua giao diện vận hành màn hình cảm ứng, rất tiện lợi.

4, Thiết bị có an toàn không?
Chúng tôi áp dụng thiết kế hai lớp và trang bị hệ thống cảnh báo quá giới hạn để đảm bảo người dùng sử dụng an toàn.

5, Yêu cầu bảo trì của thiết bị là gì?
Thường xuyên làm sạch các thành phần bên trong và kiểm tra cảm biến nhiệt độ để đảm bảo thiết bị hoạt động tốt.

6, Thiết bị này có yêu cầu môi trường lắp đặt đặc biệt không?
Thiết bị nên được đặt trong môi trường thông thoáng và tránh ánh sáng trực tiếp để đảm bảo hiệu suất.

7, Bạn có thể cung cấp hỗ trợ kỹ thuật không?
Có, chúng tôi cung cấp hỗ trợ kỹ thuật chuyên nghiệp và hướng dẫn cho khách hàng để giải quyết các vấn đề của bạn.

8, Tuổi thọ dự kiến của thiết bị là bao nhiêu?
Trong điều kiện sử dụng bình thường, tuổi thọ của thiết bị có thể đạt trên 10 năm.