Rapid Temperature Change Test Chamber Fast-Rate Thermal Cycling ESS

The DERUI DR-H204 rapid temperature change test chamber supports fast-rate thermal cycling and environmental stress screening while the specimen remains stationary. The published 800 L configuration offers selectable low-temperature ranges and cooling rates from 5°C/min to 25°C/min. Confirm the rate definition, temperature span and loaded performance in the approved technical agreement.

Mẫu DR-H204
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 800 L · 1000 × 800 × 1000 mm
Temperature Options -20 / -40 / -70°C to +150°C
Published Ramp Rates Heating 5°C/min; cooling 5 / 10 / 15 / 25°C/min
Nguồn cung cấp điện Three-phase 380 V / 50 Hz
Before Quotation Confirm average/linear rate, span, specimen mass, powered heat, utilities and FAT method
An toàn và đáng tin cậy
Chế tạo tốt
Đảm bảo chất lượng
Tùy chỉnh
Tin nhắnWhatsApp
Số điện thoại đường dây nóng 15580327593
  • Chi tiết sản phẩm
  • Thông số kỹ thuật
  • Câu hỏi thường gặp
  • Liên hệ với chúng tôi
Fast-Rate Thermal Cycling · ESS

DR-H204 Rapid Temperature Change Test Chamber

Run accelerated heating and cooling cycles for environmental stress screening of electronics, automotive components, aerospace assemblies and other temperature-sensitive products. The published 800 L configuration provides selectable low-temperature options and rapid cooling rates up to 25°C/min.

Rate definition matters: state whether the required ramp is average or linear, the start and end temperatures, air or specimen measurement, and the full powered load. A single “°C/min” value is not enough to size or accept an ESS chamber.
Published modelDR-H204
Published workspace800 L · 1000 × 800 × 1000 mm
Temperature options-20 / -40 / -70°C to +150°C
Published ratesHeat 5°C/min · Cool 5/10/15/25°C/min

Where Fast-Rate Thermal Cycling Fits

This chamber keeps the specimen stationary while the conditioned air follows a programmed ramp and dwell profile. It is designed for screening and thermal cycling—not the near-instant transfer exposure produced by a two- or three-zone thermal shock chamber.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Expose boards, modules, connectors and power electronics to repeated temperature transitions that help reveal assembly and material weaknesses.

Automotive and aerospace

Cycle controllers, sensors, lighting, avionics and compact assemblies using the applicable product or customer procedure.

Battery and energy systems

Evaluate non-abuse thermal-cycle performance only after specimen heat, electrical interfaces and the required safety scope are defined.

Published DR-H204 800L Configuration

Mục Published value Procurement note
Internal workspace 1000 × 800 × 1000 mm; 800 L Confirm W × D × H and usable space after fixtures and airflow clearance.
External dimensions 1580 × 1700 × 2260 mm Confirm installation, service and door-access clearances on the drawing.
Temperature range options -20 / -40 / -70°C to +150°C Select one refrigeration configuration for the required profile.
Biến động nhiệt độ ±1°C Confirm setpoint, stabilized condition, sensor location and load.
Tốc độ gia nhiệt 5°C/phút Confirm average or linear definition, temperature span and load state.
Cooling rate options 5 / 10 / 15 / 25°C/min Confirm selected rate, temperature span, ambient, cooling utility and load.
Sample trays and port Three SUS304 trays; Φ50 mm test hole Confirm tray loading and whether port size/quantity suits the interfaces.
Nguồn điện Three-phase 380 V / 50 Hz Rated current and power depend on the final refrigeration configuration.

Define the Ramp Before the Chamber Is Sized

Fix the endpoints

State the exact start and finish temperatures. A rate quoted across a narrow central span cannot be assumed across the full chamber range.

Choose the measurement basis

Specify chamber-air control, monitoring sensor positions and whether specimen temperature must follow the same slope.

Add the real load

Include specimen mass, fixture thermal mass, powered watts, duty cycle and cable heat leakage in the cooling calculation.

FAT basis: record the programmed and measured curves, rate calculation window, sensor map, stabilization rule and loaded or empty condition in the technical agreement.

Rapid Thermal Cycling Chamber Reference Image

DERUI DR-H204 rapid temperature change test chamber for fast-rate ESS thermal cycling

Current DERUI rapid temperature change chamber reference image. Final door, controller, ports and refrigeration arrangement follow the approved configuration.

Engineering Factors That Control Loaded Performance

Refrigeration capacity

The selected low-temperature end, cooling rate, test load and facility cooling conditions determine the required refrigeration system.

Heating and control

Heater capacity and control tuning must reproduce the programmed upward transition without unacceptable overshoot.

Airflow and fixture design

Specimen spacing and low-mass, open fixtures help conditioned air reach all surfaces and reduce local temperature lag.

Powered heat

Live electronics oppose the cooling system. Provide maximum continuous and transient watts rather than a nominal device rating.

Ports and interfaces

Define power, signals, thermocouples and communication cables so feedthroughs can be sized and sealed correctly.

Facility utilities

Confirm electrical supply, heat rejection, cooling-water conditions if applicable, drainage, ambient limits and service access.

Rapid Change Chamber vs. Thermal Shock Chamber

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Rapid temperature change chamber cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Remains stationary in one workspace. Typically transfers between separate hot and cold zones.
Exposure definition Controlled air ramp in °C/min with programmed dwells. Transfer time and recovery after zone change are central.
Powered monitoring Well suited when interfaces remain connected during cycling. Requires cable routing compatible with the transfer system.
Use when The procedure specifies a controlled temperature-change rate. The procedure requires abrupt zone transfer or thermal shock recovery.

Map the Chamber to the Test Method

The standard defines the exposure; the equipment does not create compliance by itself. Confirm the current edition, severity, test type and acceptance criteria.

Reference Typical relationship Confirm before claiming suitability
IEC 60068-2-14 Change of temperature methods Test designation, temperatures, transition, dwell and specimen operation.
MIL-STD-810H Tailored high/low temperature exposure Applicable method/procedure, rates, stabilization and functional checks.
JEDEC device methods Electronic component temperature cycling Exact JESD method, air profile, load, monitoring and lot acceptance.
Customer ESS profile Production screening Fault-detection goal, cycle count, test limits and data retention.

RFQ and FAT Checklist

Topic Information to provide or verify
Profile Start/end temperatures, rate definition, dwells, cycles and tolerances.
Specimen Envelope, mass, quantity, material, fixtures and powered heat.
Measurement Air/specimen sensors, sample rate, rate calculation and report format.
Interfaces Power, signals, thermocouples, network, test ports and safety interlocks.
Tiện ích Voltage, phase, current, cooling water if required, ambient and heat rejection.
FAT Empty/loaded condition, sensor map, ramps, dwells, alarms and acceptance limits.

Câu hỏi thường gặp

What ramp rates are published for this DR-H204 page?

The current technical table lists 5°C/min heating and 5, 10, 15 or 25°C/min cooling. Confirm the selected rate, temperature span and whether it is average or linear in the quotation.

Does the published rate apply under full powered load?

The visible table does not establish one universal loaded guarantee. Provide fixture mass and maximum powered heat so loaded performance can be calculated and included in FAT criteria.

Is this the same as a thermal shock chamber?

No. A rapid change chamber controls a programmed air-temperature ramp while the specimen remains stationary. A thermal shock chamber typically transfers the specimen between separate zones.

Is humidity standard on the 800 L configuration?

The page discusses optional humidity, but the published 800 L technical table does not establish a confirmed humidity envelope for every rapid-rate configuration. Treat it as an option requiring a separate operating chart.

What power supply is published?

The current 800 L technical table states three-phase 380 V / 50 Hz. Final current and rated power depend on the selected temperature and ramp-rate configuration.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send the full profile, rate definition, specimen drawing and mass, fixture, powered heat, interfaces, facility utilities, standards and FAT requirements.

Configure the DR-H204 from the Loaded ESS Profile

Send the complete temperature cycle and specimen data. DERUI can confirm the low-temperature option, cooling rate, refrigeration capacity, interfaces, utilities and acceptance plan before quotation.

Request a Rapid ESS Chamber Review

FacebookLinkedInXRedditWhatsApp

Mục

Thông số kỹ thuật

Kích thước bên trong (W*D*C)

1000*800*1000mm

Kích thước bên ngoài (W*D*C)

1580*1700*2260mm

Công suất làm việc

800 lít (có thể tùy chỉnh)

Chất liệu của buồng bên trong

Thép không gỉ SUS#304, bóng gương

Chất liệu của buồng ngoài

thép không gỉ phun sơn

Phạm vi nhiệt độ

-20/-40/-70℃~+150℃

Chênh lệch nhiệt độ

±1℃

Tốc độ Gia nhiệt

5℃/phút、

Tốc độ Làm mát

5℃/phút、10℃/phút、15℃/phút、25℃/phút

Khay mẫu

Thép không gỉ SUS#304, 3 chiếc

Lỗ thử nghiệm

đường kính 50mm, để luồng dây cáp

Công suất

ba pha, 380V/50Hz

Thiết bị bảo vệ an toàn

rò rỉ

quá nhiệt

quá điện áp và quá tải của máy nén khí

chạm đất của bộ gia nhiệt

Chương trình tăng tốc của buồng thử nghiệm thay đổi nhiệt độ nhanh của Derui dành cho ESS là gì?

Buồng của chúng tôi cung cấp sự thay đổi nhiệt độ nhanh lên đến 15°C mỗi phút, lý tưởng cho Kiểm tra Tải Áp Môi Trường (ESS). Tốc độ tăng nhiệt nhanh này giúp phát hiện lỗi sớm và rút ngắn quá trình thử nghiệm của bạn.

Chambers của bạn có phù hợp để kiểm tra độ ẩm không?

Có, nhiều phòng thử nghiệm chu kỳ nhiệt nhanh của chúng tôi bao gồm kiểm soát độ ẩm chính xác, cho phép chu kỳ nhiệt với độ ẩm để mô phỏng điều kiện thực tế một cách chính xác.

Thời gian giao hàng điển hình là bao lâu?

Các mẫu tiêu chuẩn thường vận chuyển trong vòng 4 đến 6 tuần. Các cấu hình tùy chỉnh có thể mất lâu hơn một chút—thường khoảng 5 đến 8 tuần, tùy thuộc vào thông số kỹ thuật của bạn.

Các tùy chọn bảo hành và hỗ trợ nào có sẵn?

Chúng tôi bảo hành các phòng thử nghiệm của mình trong 12 tháng bao gồm linh kiện và công lao động. Ngoài ra, chúng tôi cung cấp hỗ trợ kỹ thuật liên tục và dịch vụ bảo trì để giữ cho thiết bị của bạn hoạt động trơn tru.

 

Phòng thử nghiệm thay đổi nhiệt độ nhanh là gì?
Phòng thử nghiệm thay đổi nhiệt độ nhanh là thiết bị kiểm tra môi trường có khả năng chuyển đổi nhanh chóng giữa nhiệt độ cực đoan để đánh giá khả năng chịu đựng của sản phẩm dưới áp lực nhiệt. Nó rất cần thiết để xác định các lỗi tiềm ẩn trong điện tử, linh kiện ô tô và các bộ phận hàng không vũ trụ.

Tốc độ tăng nhiệt của phòng thử nghiệm của bạn đạt được bao nhiêu?
Phòng thử nghiệm của chúng tôi cung cấp sự thay đổi nhiệt độ nhanh lên đến 15°C mỗi phút, với một số cấu hình tùy chỉnh đạt tốc độ cao hơn nữa. Việc kiểm tra tăng tốc này giúp xác định lỗi sản phẩm nhanh hơn so với các phòng thử nghiệm thông thường.

Các ngành công nghiệp nào sử dụng phòng thử nghiệm chu kỳ nhiệt nhanh?
Các ngành chính bao gồm điện tử ô tô, linh kiện hàng không vũ trụ, sản xuất bán dẫn, kiểm tra pin, thiết bị y tế và thiết bị viễn thông - bất cứ nơi nào độ tin cậy của sản phẩm dưới áp lực nhiệt là điều quan trọng.

 Làm thế nào để phòng thử nghiệm của bạn đảm bảo độ đồng đều nhiệt độ?
Chúng tôi sử dụng hệ thống luồng không khí tiên tiến với hệ thống ống dẫn chính xác và quạt hiệu suất cao để duy trì độ đồng đều nhiệt độ trong phạm vi ±1.5°C trong toàn bộ thể tích phòng thử nghiệm, đảm bảo điều kiện thử nghiệm nhất quán.

Phòng thử nghiệm của bạn tuân thủ các tiêu chuẩn nào?
Các phòng thử nghiệm của chúng tôi đáp ứng các tiêu chuẩn quốc tế chính bao gồm MIL-STD-810 cho kiểm tra môi trường, tiêu chuẩn JEDEC cho kiểm tra bán dẫn, IEC 60068-2-14 cho kiểm tra thay đổi nhiệt độ và ISO 17025 cho năng lực phòng thí nghiệm.

Tôi có thể thực hiện kiểm tra nhiệt độ và độ ẩm trong cùng một phòng không?
Có, chúng tôi cung cấp các tùy chọn kiểm soát độ ẩm tích hợp từ 10% đến 95% RH, cho phép chu kỳ nhiệt và độ ẩm kết hợp trong một hệ thống duy nhất để kiểm tra môi trường toàn diện.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
Tin nhắnTin nhắn

Yêu cầu báo giá