Chambre d'essai à double couche avec contrôle de température

Le DERUI double-layer temperature and humidity test chamber combines two independently controlled test zones in one vertical footprint. Run different profiles simultaneously to increase laboratory throughput while keeping specimen batches and environmental conditions separate.

Control Independent upper and lower controllers with separate start/stop
Capacity per Layer 80 / 100 / 150 / 225 / 408 L
Temperature Options 0 / -20 / -40 / -70°C to +150°C
Plage d'Humidité 20% to 98% RH; request the combined operating chart
Core Benefit Two simultaneous tests with less floor space than separate cabinets
Before Quotation Confirm both profiles, loads, control architecture, utilities and FAT
Sûr et fiable
bien fabriqué
Assurance qualité
personnalisation
MessageWhatsApp
Numéro de hotline 15580327593
  • Détails du produit
  • Paramètres techniques
  • FAQ
  • Contactez-nous
Two Independent Test Zones · One Footprint

Double-Layer Temperature and Humidity Test Chamber

Run two different environmental profiles at the same time without installing two separate cabinets. Each upper and lower chamber has its own controller and independent start/stop operation for parallel R&D, verification and quality-control testing.

Independent control must be specified clearly: confirm whether each layer has fully independent refrigeration, heating, humidification, sensors, data records and safety limits in the approved configuration—not only separate display screens.
Control architectureTwo independently operated chambers
Published capacity per layer80 / 100 / 150 / 225 / 408 L
Temperature options0 / -20 / -40 / -70°C to +150°C
Plage d'humidité20% à 98% HR

Why Use a Double-Layer Chamber?

Two simultaneous profiles

Run different setpoints, programmes or specimen groups in the upper and lower zones during the same shift.

Higher laboratory throughput

Increase available test capacity without allocating the floor area required for two standalone chambers.

Separation of test work

Keep development and routine QC, different batches or different temperature-humidity conditions operationally separate.

Published DR-H201 Double-Layer Model Matrix

Modèle Volume per layer Internal size per layer
DR-H201-80-2 80 L 500 × 400 × 400 mm
DR-H201-100-2 100 L 400 × 500 × 500 mm
DR-H201-150-2 150 L 500 × 600 × 500 mm
DR-H201-225-2 cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 500 × 750 × 600 mm
DR-H201-408-2 cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 600 × 850 × 800 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits the source lists three dimensions but does not consistently establish the W × D × H order. Confirm orientation and usable clearance on the approved drawing.

Published Environmental Performance

Article Published value cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Temperature range options 0 / -20 / -40 / -70°C to +150°C Select the required low-temperature configuration for both layers.
Uniformité de température ≤2°C, no-load Confirm sensor map, setpoint and working-space definition.
Fluctuation de température ±0.5°C, no-load Confirm stabilized condition and measurement interval.
Plage d'humidité 20% à 98% HR Request the valid combined temperature-RH operating envelope.
Humidity uniformity / fluctuation +2/-3% RH / ±2% RH Confirm setpoint, load and measurement method.
Heating / cooling 1–3°C/min / 0.7–1°C/min Confirm average definition, temperature span and loaded performance.
Time setting 1–60,000 min Confirm programme steps, cycles and independent records.

Confirm True Independence Between the Two Layers

Control independence

Verify separate programmes, sensors, alarms, start/stop control and data files for upper and lower chambers.

Thermal independence

Define simultaneous worst-case profiles and confirm one layer’s load does not invalidate the other layer’s performance.

Utility independence

Confirm shared versus separate refrigeration, humidification, water, drainage and electrical protection architecture.

Construction and Daily-Use Features

SUS304 workspaces

Brushed stainless-steel chambers, silicone seals and locking doors support repeated climatic exposure.

Adjustable sample racks

Rack height can be adapted to the specimen, but loading must preserve supply and return airflow.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Heated observation windows and selectable 50 or 100 mm cable ports support monitoring and powered tests.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Centrifugal blowers, adjustable deflectors and supply/return ducts distribute conditioned air in each zone.

Humidity system

Independent humidification and evaporator-based dehumidification are stated; confirm water and control architecture per layer.

Compact vertical layout

Stacked zones increase throughput per floor area, but room height, service clearance and transport access must be checked.

Match Each Layer to Its Test Method

Reference Utilisation typique cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Cold testing Test type, setpoint, stabilization, duration and specimen operation.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Dry heat Heat-dissipating state, airflow and measurement points.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Steady damp heat Temperature, RH, duration, load and evaluation.
IEC 60068-2-30 Cyclic damp heat Cycle, transitions, condensation and recovery.

RFQ and Dual-Zone FAT Checklist

Topic Information to provide or verify
Layer A profile Setpoints, ramps, dwells, cycles, load and powered heat.
Layer B profile Setpoints, ramps, dwells, cycles, load and powered heat.
Simultaneous operation Worst-case combined condition and required performance in both layers.
Interfaces Ports, power, signals, thermocouples, communications and data files.
Utilités Voltage, current, water, drain, heat rejection and service access.
FAT Separate sensor maps, simultaneous profiles, alarms, records and acceptance limits.

Foire Aux Questions

Can the two layers run different test conditions?

Yes. The page states that each cabinet has its own controller and can start or stop independently. Confirm the full thermal and utility architecture in the quotation.

Is the listed capacity total volume?

The table describes the volume of the upper or lower layer. For example, the 150 L model provides two nominal 150 L workspaces.

Can one layer run temperature-only while the other runs humidity?

This should be possible only when the selected configuration provides independent humidity and refrigeration control. State the simultaneous profiles for confirmation.

Does 20–98% RH apply at every temperature?

No rectangular envelope should be assumed. Request the combined temperature-RH chart for the selected configuration.

Can powered specimens be tested?

Yes when port, cable, specimen heat and safety requirements are included in the engineering calculation.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send both layer profiles, specimen drawings, quantities, mass, powered heat, interfaces, utilities and simultaneous FAT requirements.

Configure Both Test Zones Before Quotation

Send the upper- and lower-layer profiles separately. DERUI can confirm capacity, temperature options, humidity envelope, interfaces, utilities and simultaneous acceptance testing.

Request a Double-Layer Chamber Review

FacebookLinkedInXRedditWhatsApp
Modèle DR-H201 -80- 2 DR- H201 -100 - 2 DR- H201 -150 - 2 DR- H201 -225 - 2 DR- H201 -408 - 2
Volume de la couche supérieure (inférieure) 80L 100L 150L 225L 408L
Dimensions de la couche supérieure (inférieure) 500 * 400 * 400 400 * 500 * 500 500 * 600 * 500 500 * 750 * 600 600 * 850 * 800
index Plage de température 0℃~150℃ -20℃~150℃ -40℃~150℃ -70℃~150℃ 
Uniformité de température ≤2℃ (temps sans charge)
Fluctuation de température ±0,5℃ (temps sans charge)
Plage d'humidité 20%~98% HR
Uniformité de l'humidité +2% -3% HR
Fluctuation d'humidité ±2%
Vitesse de chauffage 1,0~3,0℃/min
Vitesse de refroidissement 0,7~1,0℃/min
Plage de réglage du temps 1~60000M
Trou de test Il est installé sur le côté gauche de la machine pour le cordon d'alimentation externe ou le câble de signal
Fenêtre d'observation 210×275mmOU395×395mm (Horizon efficace)
 
 
 
 
 

1、À quelles occasions la chambre de test à contrôle de température à double couche convient-elle ?
Elle convient à diverses occasions expérimentales telles que les tests de matériaux, les tests de produits et le contrôle de qualité.

2、Quelle est la plage de température de l'équipement ?
Cette chambre d'essai dispose de trois spécifications de plage de température : -20°C à +150°C, -40°C à +150°C, et -70°C à +150°C, adaptées à diverses exigences expérimentales.

3、Comment définir les paramètres expérimentaux ?
Les paramètres tels que la température et le temps peuvent être facilement réglés via l'interface de l'écran tactile, ce qui est très pratique.

4、Quelle est la sécurité de l'équipement ?
Nous adoptons une conception à double couche et sommes équipés d'un système d'alarme en cas de dépassement de limite pour assurer la sécurité des utilisateurs.

5、Quelles sont les exigences d'entretien de l'équipement ?
Nettoyez régulièrement les composants internes et vérifiez les capteurs de température pour assurer le bon fonctionnement de l'équipement.

6、Cet appareil nécessite-t-il un environnement d'installation spécifique ?
L'appareil doit être placé dans un environnement bien ventilé et éviter la lumière directe du soleil pour garantir ses performances.

7、Pouvez-vous fournir un support technique ?
Oui, nous offrons un support technique professionnel et des conseils à nos clients pour résoudre vos problèmes.

8、Quelle est la durée de vie estimée de l'équipement ?
Dans des conditions d'utilisation normales, la durée de vie de l'équipement peut dépasser 10 ans.