Этаж 1, д. 3, проспект Шуган, город Хунмэй, город Дунгуань, провинция Гуандун, Китай

Производитель климатических камер для испытаний окружающей среды более 20 летБолее 3000 заказов клиентов по всему миру           Электронная почта: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Двухслойная камера для испытаний с контролем температуры

The DERUI double-layer temperature and humidity test chamber combines two independently controlled test zones in one vertical footprint. Run different profiles simultaneously to increase laboratory throughput while keeping specimen batches and environmental conditions separate.

Control Independent upper and lower controllers with separate start/stop
Capacity per Layer 80 / 100 / 150 / 225 / 408 L
Temperature Options 0 / -20 / -40 / -70°C to +150°C
Диапазон влажности 20% to 98% RH; request the combined operating chart
Core Benefit Two simultaneous tests with less floor space than separate cabinets
Before Quotation Confirm both profiles, loads, control architecture, utilities and FAT
Безопасно и надежно
качественно изготовлено
Гарантия качества
кастомизация
СообщениеWhatsApp
Номер горячей линии 15580327593
  • Детали продукта
  • Технические параметры
  • Часто задаваемые вопросы
  • Свяжитесь с нами
Two Independent Test Zones · One Footprint

Double-Layer Temperature and Humidity Test Chamber

Run two different environmental profiles at the same time without installing two separate cabinets. Each upper and lower chamber has its own controller and independent start/stop operation for parallel R&D, verification and quality-control testing.

Independent control must be specified clearly: confirm whether each layer has fully independent refrigeration, heating, humidification, sensors, data records and safety limits in the approved configuration—not only separate display screens.
Control architectureTwo independently operated chambers
Published capacity per layer80 / 100 / 150 / 225 / 408 L
Temperature options0 / -20 / -40 / -70°C to +150°C
Диапазон влажности20% до 98% RH

Why Use a Double-Layer Chamber?

Two simultaneous profiles

Run different setpoints, programmes or specimen groups in the upper and lower zones during the same shift.

Higher laboratory throughput

Increase available test capacity without allocating the floor area required for two standalone chambers.

Separation of test work

Keep development and routine QC, different batches or different temperature-humidity conditions operationally separate.

Published DR-H201 Double-Layer Model Matrix

Модель Volume per layer Internal size per layer
DR-H201-80-2 80 л 500 × 400 × 400 mm
DR-H201-100-2 100 л 400 × 500 × 500 mm
DR-H201-150-2 150 L 500 × 600 × 500 mm
DR-H201-225-2 cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 500 × 750 × 600 mm
DR-H201-408-2 cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 600 × 850 × 800 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits the source lists three dimensions but does not consistently establish the W × D × H order. Confirm orientation and usable clearance on the approved drawing.

Published Environmental Performance

Пункт Published value cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Temperature range options 0 / -20 / -40 / -70°C to +150°C Select the required low-temperature configuration for both layers.
Равномерность температуры ≤2°C, no-load Confirm sensor map, setpoint and working-space definition.
Колебания температуры ±0.5°C, no-load Confirm stabilized condition and measurement interval.
Диапазон влажности 20% до 98% RH Request the valid combined temperature-RH operating envelope.
Humidity uniformity / fluctuation +2/-3% RH / ±2% RH Confirm setpoint, load and measurement method.
Heating / cooling 1–3°C/min / 0.7–1°C/min Confirm average definition, temperature span and loaded performance.
Time setting 1–60,000 min Confirm programme steps, cycles and independent records.

Confirm True Independence Between the Two Layers

Control independence

Verify separate programmes, sensors, alarms, start/stop control and data files for upper and lower chambers.

Thermal independence

Define simultaneous worst-case profiles and confirm one layer’s load does not invalidate the other layer’s performance.

Utility independence

Confirm shared versus separate refrigeration, humidification, water, drainage and electrical protection architecture.

Construction and Daily-Use Features

SUS304 workspaces

Brushed stainless-steel chambers, silicone seals and locking doors support repeated climatic exposure.

Adjustable sample racks

Rack height can be adapted to the specimen, but loading must preserve supply and return airflow.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Heated observation windows and selectable 50 or 100 mm cable ports support monitoring and powered tests.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Centrifugal blowers, adjustable deflectors and supply/return ducts distribute conditioned air in each zone.

Humidity system

Independent humidification and evaporator-based dehumidification are stated; confirm water and control architecture per layer.

Compact vertical layout

Stacked zones increase throughput per floor area, but room height, service clearance and transport access must be checked.

Match Each Layer to Its Test Method

Reference Типичное использование cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
IEC 60068-2-1 Cold testing Test type, setpoint, stabilization, duration and specimen operation.
IEC 60068-2-2 Dry heat Heat-dissipating state, airflow and measurement points.
IEC 60068-2-78 Steady damp heat Temperature, RH, duration, load and evaluation.
IEC 60068-2-30 Cyclic damp heat Cycle, transitions, condensation and recovery.

RFQ and Dual-Zone FAT Checklist

Topic Information to provide or verify
Layer A profile Setpoints, ramps, dwells, cycles, load and powered heat.
Layer B profile Setpoints, ramps, dwells, cycles, load and powered heat.
Simultaneous operation Worst-case combined condition and required performance in both layers.
Interfaces Ports, power, signals, thermocouples, communications and data files.
Коммунальные услуги Voltage, current, water, drain, heat rejection and service access.
FAT Separate sensor maps, simultaneous profiles, alarms, records and acceptance limits.

Часто задаваемые вопросы

Can the two layers run different test conditions?

Yes. The page states that each cabinet has its own controller and can start or stop independently. Confirm the full thermal and utility architecture in the quotation.

Is the listed capacity total volume?

The table describes the volume of the upper or lower layer. For example, the 150 L model provides two nominal 150 L workspaces.

Can one layer run temperature-only while the other runs humidity?

This should be possible only when the selected configuration provides independent humidity and refrigeration control. State the simultaneous profiles for confirmation.

Does 20–98% RH apply at every temperature?

No rectangular envelope should be assumed. Request the combined temperature-RH chart for the selected configuration.

Can powered specimens be tested?

Yes when port, cable, specimen heat and safety requirements are included in the engineering calculation.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send both layer profiles, specimen drawings, quantities, mass, powered heat, interfaces, utilities and simultaneous FAT requirements.

Configure Both Test Zones Before Quotation

Send the upper- and lower-layer profiles separately. DERUI can confirm capacity, temperature options, humidity envelope, interfaces, utilities and simultaneous acceptance testing.

Request a Double-Layer Chamber Review

FacebookLinkedInXRedditWhatsApp
Модель DR-H201 -80- 2 DR-H201 -100- 2 DR-H201 -150- 2 DR-H201 -225- 2 DR-H201 -408- 2
Объем верхнего (нижнего) слоя 80L 100L 150L 225L 408L
Размеры верхнего (нижнего) слоя 500 * 400 * 400 400 * 500 * 500 500 * 600 * 500 500 * 750 * 600 600 * 850 * 800
индекс Диапазон температур 0℃~150℃    -20℃~150℃    -40℃~150℃    -70℃~150℃ 
Равномерность температуры ≤2℃ (время без нагрузки)
Колебания температуры ±0.5℃ (время без нагрузки)
Диапазон влажности 20%~98% ВЛ
Равномерность влажности +2% -3% ВЛ
Колебания влажности ±2%
Темп нагрева 1.0~3.0℃/мин
Темп охлаждения 0.7~1.0℃/мин
Диапазон настройки времени 1~60000М
Испытательное отверстие Устанавливается с левой стороны машины для внешнего тестового силового кабеля или сигнального кабеля
Окно наблюдения 210×275мм или 395×395мм (Эффективный горизонт)
 
 
 
 
 

1. Для каких случаев подходит камера двойного температурного контроля с двойным слоем?
Она подходит для различных экспериментальных случаев, таких как испытания материалов, тестирование продукции и контроль качества.

2. Какой диапазон температур у оборудования?
Эта камера имеет три спецификации диапазона температуры: от -20°C до +150°C, от -40°C до +150°C и от -70°C до +150°C, что подходит для различных экспериментальных требований.

3. Как настроить экспериментальные параметры?
Параметры такие как температура и время легко настраиваются через интерфейс сенсорного экрана, что очень удобно.

4. Насколько безопасно оборудование?
Мы используем двухслойный дизайн и оснащены системой аварийного оповещения о превышении лимита, чтобы обеспечить безопасное использование пользователями.

5. Какие требования к обслуживанию оборудования?
Регулярно очищайте внутренние компоненты и проверяйте датчики температуры, чтобы обеспечить хорошую работу оборудования.

6. Требует ли это устройство специальной установки?
Устройство должно быть размещено в хорошо проветриваемой среде и избегать прямых солнечных лучей для обеспечения производительности.

7. Можете ли вы предоставить техническую поддержку?
Да, мы предлагаем профессиональную техническую поддержку и консультации нашим клиентам для решения ваших проблем.

8. Каков предполагаемый срок службы оборудования?
При нормальных условиях эксплуатации срок службы оборудования может превышать 10 лет.