Piso 1, No. 3, Avenida Shugang, Vila Hongmei, Cidade de Dongguan, Província de Guangdong, China

Fabricante de câmaras de teste ambiental há 20 anosMais de 3000 entregas a clientes em todo o mundo           Email: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Câmara de Teste de Temperatura Controlada de Dupla Camada

A DERUI double-layer temperature and humidity test chamber combines two independently controlled test zones in one vertical footprint. Run different profiles simultaneously to increase laboratory throughput while keeping specimen batches and environmental conditions separate.

Control Independent upper and lower controllers with separate start/stop
Capacity per Layer 80 / 100 / 150 / 225 / 408 L
Temperature Options 0 / -20 / -40 / -70°C to +150°C
Faixa de Humidade 20% to 98% RH; request the combined operating chart
Core Benefit Two simultaneous tests with less floor space than separate cabinets
Before Quotation Confirm both profiles, loads, control architecture, utilities and FAT
Seguro e fiável
bem construído
Garantia de qualidade
personalização
MensagemWhatsApp
Número de Linha Direta 15580327593
  • Detalhes do Produto
  • Parâmetros técnicos
  • Perguntas Frequentes
  • Contacte-nos
Two Independent Test Zones · One Footprint

Double-Layer Temperature and Humidity Test Chamber

Run two different environmental profiles at the same time without installing two separate cabinets. Each upper and lower chamber has its own controller and independent start/stop operation for parallel R&D, verification and quality-control testing.

Independent control must be specified clearly: confirm whether each layer has fully independent refrigeration, heating, humidification, sensors, data records and safety limits in the approved configuration—not only separate display screens.
Control architectureTwo independently operated chambers
Published capacity per layer80 / 100 / 150 / 225 / 408 L
Temperature options0 / -20 / -40 / -70°C to +150°C
Faixa de humidade20% a 98% RH

Why Use a Double-Layer Chamber?

Two simultaneous profiles

Run different setpoints, programmes or specimen groups in the upper and lower zones during the same shift.

Higher laboratory throughput

Increase available test capacity without allocating the floor area required for two standalone chambers.

Separation of test work

Keep development and routine QC, different batches or different temperature-humidity conditions operationally separate.

Published DR-H201 Double-Layer Model Matrix

Modelo Volume per layer Internal size per layer
DR-H201-80-2 80 L 500 × 400 × 400 mm
DR-H201-100-2 100 L 400 × 500 × 500 mm
DR-H201-150-2 150 L 500 × 600 × 500 mm
DR-H201-225-2 225 L 500 × 750 × 600 mm
DR-H201-408-2 cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 600 × 850 × 800 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits the source lists three dimensions but does not consistently establish the W × D × H order. Confirm orientation and usable clearance on the approved drawing.

Published Environmental Performance

Item Published value cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Temperature range options 0 / -20 / -40 / -70°C to +150°C Select the required low-temperature configuration for both layers.
Uniformidade de temperatura ≤2°C, no-load Confirm sensor map, setpoint and working-space definition.
Variação de temperatura ±0.5°C, no-load Confirm stabilized condition and measurement interval.
Faixa de humidade 20% a 98% RH Request the valid combined temperature-RH operating envelope.
Humidity uniformity / fluctuation +2/-3% RH / ±2% RH Confirm setpoint, load and measurement method.
Heating / cooling 1–3°C/min / 0.7–1°C/min Confirm average definition, temperature span and loaded performance.
Time setting 1–60,000 min Confirm programme steps, cycles and independent records.

Confirm True Independence Between the Two Layers

Control independence

Verify separate programmes, sensors, alarms, start/stop control and data files for upper and lower chambers.

Thermal independence

Define simultaneous worst-case profiles and confirm one layer’s load does not invalidate the other layer’s performance.

Utility independence

Confirm shared versus separate refrigeration, humidification, water, drainage and electrical protection architecture.

Construction and Daily-Use Features

SUS304 workspaces

Brushed stainless-steel chambers, silicone seals and locking doors support repeated climatic exposure.

Adjustable sample racks

Rack height can be adapted to the specimen, but loading must preserve supply and return airflow.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Heated observation windows and selectable 50 or 100 mm cable ports support monitoring and powered tests.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Centrifugal blowers, adjustable deflectors and supply/return ducts distribute conditioned air in each zone.

Humidity system

Independent humidification and evaporator-based dehumidification are stated; confirm water and control architecture per layer.

Compact vertical layout

Stacked zones increase throughput per floor area, but room height, service clearance and transport access must be checked.

Match Each Layer to Its Test Method

Reference Uso típico cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
IEC 60068-2-1 Cold testing Test type, setpoint, stabilization, duration and specimen operation.
IEC 60068-2-2 Dry heat Heat-dissipating state, airflow and measurement points.
IEC 60068-2-78 Steady damp heat Temperature, RH, duration, load and evaluation.
IEC 60068-2-30 Cyclic damp heat Cycle, transitions, condensation and recovery.

RFQ and Dual-Zone FAT Checklist

Topic Information to provide or verify
Layer A profile Setpoints, ramps, dwells, cycles, load and powered heat.
Layer B profile Setpoints, ramps, dwells, cycles, load and powered heat.
Simultaneous operation Worst-case combined condition and required performance in both layers.
Interfaces Ports, power, signals, thermocouples, communications and data files.
Utilidades Voltage, current, water, drain, heat rejection and service access.
FAT Separate sensor maps, simultaneous profiles, alarms, records and acceptance limits.

Perguntas Frequentes

Can the two layers run different test conditions?

Yes. The page states that each cabinet has its own controller and can start or stop independently. Confirm the full thermal and utility architecture in the quotation.

Is the listed capacity total volume?

The table describes the volume of the upper or lower layer. For example, the 150 L model provides two nominal 150 L workspaces.

Can one layer run temperature-only while the other runs humidity?

This should be possible only when the selected configuration provides independent humidity and refrigeration control. State the simultaneous profiles for confirmation.

Does 20–98% RH apply at every temperature?

No rectangular envelope should be assumed. Request the combined temperature-RH chart for the selected configuration.

Can powered specimens be tested?

Yes when port, cable, specimen heat and safety requirements are included in the engineering calculation.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send both layer profiles, specimen drawings, quantities, mass, powered heat, interfaces, utilities and simultaneous FAT requirements.

Configure Both Test Zones Before Quotation

Send the upper- and lower-layer profiles separately. DERUI can confirm capacity, temperature options, humidity envelope, interfaces, utilities and simultaneous acceptance testing.

Request a Double-Layer Chamber Review

FacebookLinkedInXRedditWhatsApp
Modelo DR-H201 -80- 2 DR- H201 -100 - 2 DR- H201 -150 - 2 DR- H201 -225 - 2 DR- H201 -408 - 2
Volume da camada superior (inferior) 80L 100L 150L 225L 408L
Dimensões da camada superior (inferior) 500 * 400 * 400 400 * 500 * 500 500 * 600 * 500 500 * 750 * 600 600 * 850 * 800
índice Faixa de temperatura 0℃~150℃ -20℃~150℃ -40℃~150℃ -70℃~150℃ 
Uniformidade de temperatura ≤2℃(Tempo sem carga)
Variação de temperatura ±0.5℃(Tempo sem carga)
Faixa de humidade 20%~98% HR
Uniformidade de humidade +2% -3% HR
Variação de humidade ±2%
Taxa de aquecimento 1.0~3.0℃/min
Taxa de arrefecimento 0.7~1.0℃/min
Faixa de configuração de tempo 1~60000M
Orifício de teste Está instalado no lado esquerdo da máquina para o cabo de alimentação de teste externo ou cabo de sinal
Janela de observação 210×275mm OU 395×395mm (Horizonte efetivo)
 
 
 
 
 

1、Para que ocasiões é adequado o teste de câmara de controlo de temperatura de dupla camada?
É adequado para várias ocasiões experimentais, como testes de materiais, testes de produtos e controlo de qualidade.

2、Qual é a faixa de temperatura do equipamento?
Esta câmara de teste possui três especificações de faixa de temperatura: -20°C a +150°C, -40°C a +150°C e -70°C a +150°C, adequadas para várias exigências experimentais.

3、Como configurar os parâmetros experimentais?
Os parâmetros como temperatura e tempo podem ser facilmente configurados através da interface de operação com ecrã tátil, o que é muito conveniente.

4、Quão seguro é o equipamento?
Adotamos um design de dupla camada e estamos equipados com um sistema de alarme de limite excedido para garantir o uso seguro pelos utilizadores.

5、Quais são os requisitos de manutenção do equipamento?
Limpar regularmente os componentes internos e verificar os sensores de temperatura para garantir que o equipamento funcione bem.

6、Este dispositivo requer um ambiente de instalação especial?
O dispositivo deve ser colocado num ambiente bem ventilado e evitar luz solar direta para garantir o desempenho.

7、Pode fornecer suporte técnico?
Sim, oferecemos suporte técnico profissional e orientação aos nossos clientes para resolver os seus problemas.

8、Qual é a vida útil estimada do equipamento?
Sob condições normais de uso, a vida útil do equipamento pode atingir mais de 10 anos.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MensagemMensagem

Solicitar Orçamento