Chambre à humidité élevée Double 85

Le DERUI DR-H201-D85 Double 85 high humidity chamber provides controlled 85°C and 85% RH exposure for electronics, semiconductors, automotive components, photovoltaic products and materials. Five published capacities support specimen-level and batch reliability testing.

Series DR-H201-D85
Core Condition 85°C temperature + 85% relative humidity
Published Capacities 100 / 150 / 225 / 408 / 1000 L
Typical Use Steady damp-heat, THB and product-specific 85/85 reliability testing
Key Selection Basis Loaded workspace, sample quantity, bias/power, duration and monitoring
Before Quotation Confirm standard, specimen state, interfaces, utilities and FAT criteria
Sûr et fiable
bien fabriqué
Assurance qualité
personnalisation
MessageWhatsApp
Numéro de hotline 15580327593
  • Détails du produit
  • FAQ
  • Paramètres techniques
  • Contactez-nous
85°C / 85% RH Constant Damp Heat

DR-H201-D85 Double 85 High Humidity Chamber

Run controlled 85°C and 85% RH exposure for electronics, semiconductor devices, automotive components, photovoltaic modules and material systems. The DR-H201-D85 series provides five published workspace sizes for steady damp-heat reliability testing.

Double 85 is a condition, not a complete test method: duration, specimen bias or powered state, stabilization, monitoring and pass/fail criteria must come from the applicable standard or approved test plan.
Core condition85°C + 85% RH
Published models100 / 150 / 225 / 408 / 1000 L
SeriesDR-H201-D85
Primary purposeConstant damp-heat reliability exposure

What Double 85 Testing Reveals

Sustained heat and moisture can accelerate moisture ingress, corrosion, insulation decline, delamination and material-interface failures. The chamber provides the exposure; the product standard determines how results are evaluated.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Investigate package moisture resistance, corrosion, leakage-current changes and biased damp-heat reliability.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Evaluate connectors, sensors, control electronics, coatings and seals under prolonged hot-humid stress.

Photovoltaic materials

Support damp-heat exposure of modules or materials when workspace, loading, duration and IEC 61215 procedure are confirmed.

Published DR-H201-D85 Model Matrix

Modèle Internal size W × H × D Low-temperature options Published supply
DR-H201-D85-100 400 × 500 × 500 mm -20 / -40 / -70°C Single-phase 220 V
DR-H201-D85-150 500 × 500 × 600 mm -20 / -40 / -70°C Single-phase 220 V
DR-H201-D85-225 500 × 750 × 600 mm -20 / -40 / -70°C Three-phase 380 V
DR-H201-D85-408 600 × 850 × 800 mm -20 / -40 / -70°C Three-phase 380 V
DR-H201-D85-1000 cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits -20 / -40 / -70°C Three-phase 380 V
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits select the low-temperature option only if the wider programme requires it. A dedicated 85/85 exposure does not itself require -40°C or -70°C capability.

Build a Defensible 85/85 Test Plan

Define conditioning

State specimen preparation, preconditioning and whether the device is unbiased, biased or continuously powered.

Define exposure

Specify 85°C/85% RH duration, stabilization rule, monitoring interval, interruptions and allowed tolerances.

Define evaluation

Document electrical, optical, mechanical or visual measurements and the exact failure criteria.

Double 85 Chamber Reference Image

DERUI DR-H201-D85 double 85 high humidity chamber for 85°C 85% RH testing

DERUI Double 85 high-humidity chamber reference image. Final workspace, controller, ports and supply follow the approved model configuration.

Loading Practices That Protect Uniformity

Keep air paths open

Leave clearance between samples and avoid blocking supply or return air with trays, fixtures or large panels.

Control specimen density

Define batch quantity, mass and moisture absorption because a crowded load changes recovery and local RH.

Seal cable entries

Specify bias wiring and sensor leads, then seal unused port area to limit room-air leakage.

Use appropriate water

Follow the approved water-quality, tank/feed, cleaning and drainage requirements for the humidification system.

Manage condensation

Use the prescribed ramp and post-test handling sequence; uncontrolled door opening can add non-test condensation.

Record interruptions

Document alarms, door openings, water events and deviations that may affect the validity of long exposures.

Match the Chamber to the Applicable Method

Reference Typical relationship Do not assume
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Steady-state damp heat That every product uses 85°C/85% RH or the same duration.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits PV module damp-heat qualification That chamber capability alone proves module compliance.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Steady-state temperature-humidity bias testing That bias circuits, monitoring and failure criteria are automatically included.
Customer/automotive specification Product-specific reliability exposure That “Double 85” defines sample state, duration or acceptance.

RFQ and FAT Checklist

Topic Information to provide or verify
Specimen Dimensions, mass, quantity, material, rack and airflow clearance.
Test plan Standard/edition, 85/85 duration, bias, monitoring and pass/fail criteria.
Interfaces Power, signals, thermocouples, test ports and external measurement equipment.
Utilités Voltage, phase, current, water quality, drainage and ambient conditions.
FAT Sensor map, 85/85 stabilization, deviation, uniformity, records and report format.
Documents Approved drawing, configuration list, manuals, calibration scope and acceptance report.

Foire Aux Questions

What does Double 85 mean?

It refers to exposure at 85°C and 85% relative humidity. It does not by itself define duration, specimen operation or acceptance criteria.

Which chamber size should I choose?

Select from the complete loaded envelope, fixture, sample quantity and airflow clearance—not nominal litres alone.

Does every Double 85 test run for 1,000 hours?

No. Some procedures use long exposures, but the applicable standard or customer plan must define duration and interruptions.

Can samples be electrically biased?

Yes when the configuration includes suitable feedthroughs and the approved plan defines bias, monitoring, heat and safety requirements.

Does this chamber certify IEC 61215 compliance?

No chamber alone certifies a product. It can provide the required damp-heat exposure when configuration, calibration, loading and procedure meet the applicable method.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send the standard, specimen size and quantity, exposure duration, bias/power, interfaces, workspace, utilities and FAT requirements.

Configure the Double 85 Chamber Around the Test Plan

Send the specimen layout, 85°C/85% RH duration, powered or biased state, monitoring points and acceptance criteria. DERUI can confirm model size, interfaces, utilities and FAT scope.

Request a Double 85 Chamber Review

FacebookLinkedInXRedditWhatsApp

Q : À quoi sert une chambre à haute humidité Double 85 ?

R : Elle est principalement utilisée pour les tests de fiabilité en simulant des conditions de température de 85°C et d'humidité relative de 85%. Cela permet de vérifier la résistance de produits tels que l'électronique, les pièces automobiles et les modules PV dans des environnements difficiles et humides.

Q : En quoi la chambre de test Double 85 (85/85) diffère-t-elle des autres chambres environnementales ?

R : La chambre Double 85 se concentre sur une température et une humidité élevées constantes, ce qui accélère les tests de vieillissement pour prévoir la durée de vie du produit sous stress de chaleur humide—ce que les chambres standard ne simulent pas aussi précisément.

Q : Quels secteurs bénéficient de l'utilisation de ces chambres ?

R : La fabrication électronique, le test de composants automobiles, la qualification de modules PV solaires, le développement de batteries et le test de fiabilité des dispositifs médicaux dépendent fortement des chambres Double 85.

Q : La chambre peut-elle être personnalisée pour différentes tailles d'échantillons ?

R : Oui, Derui propose différentes tailles de chambres et des options de personnalisation pour s'adapter à différents volumes, vitesses de test, et même plages d'humidité si vos tests nécessitent une faible HR ou un débit élevé.

Q : Quelles normes la chambre Double 85 de Derui respecte-t-elle ?

R : Nos chambres respectent des normes clés de l'industrie telles que IEC 60068, ASTM, et les protocoles de fiabilité automobile, y compris ceux pour les modules PV selon IEC 61215.

Q : Quelle est l'efficacité énergétique de ces chambres ?

R : Derui conçoit ses chambres avec une isolation durable et des systèmes économes en énergie, afin qu'elles fonctionnent efficacement sans compromettre la précision ou la cohérence des tests.

Q : Quel entretien est nécessaire pour les systèmes d'humidité élevée ?

R : La calibration régulière, le nettoyage du système d'humidification et la surveillance de la condensation sont des étapes essentielles. Derui fournit des guides détaillés et un support pour assurer le bon fonctionnement de votre chambre.

Q : Combien de temps faut-il pour commencer les tests après l'installation ?

R : Après une installation et une calibration professionnelles, vous pouvez généralement commencer des tests précis en un jour ou deux, garantissant une température et une humidité uniformes à l'intérieur de la chambre.

Modèle

DR-H201-D85-100

DR-H201-D85-150

DR-H201-D85-225

DR-H201-D85-408

DR-H201-D85-1000

Dimension intérieure (L*H*P)

400*500*500mm

500*500*600mm

500*750*600mm

600*850*800mm

1000*1000*800mm

Dimension extérieure (Type sus) (L*H*P)

950*1400*1100mm

1100*1500*1100mm

1100*1670*1200mm

1200*1770*1400mm

1550*2100*1400mm

Dimension extérieure (Type peinture) (L*H*P)

700*1400*1100mm

800*1500*1100mm

800*1670*1200mm

900*1770*1400mm

1550*2100*1400mm

Température(℃)

-20/-40/-70

-20/-40/-70

-20/-40/-70

-20/-40/-70

-20/-40/-70

Puissance Totale(kw)

4.5/4.5/6.5

5/5/6.5

9.5/9.5/11.6

9.5/9.5/11.6

17/17/21.5

Courant Maximal(A)

25/25/32

32/32/40

25/32/40

32

50/50/60

Tension(V)

Mono phase 220V

Mono phase 220V

Triphasé 380V

Triphasé 380V