Étage 1, No. 3, Avenue Shugang, Ville de Hongmei, Dongguan, Province du Guangdong, Chine

Fabricant de chambres d'essai environnemental depuis 20 ansPlus de 3000 livraisons clients dans le monde entier    Email : shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Rapid Temperature Change Test Chamber Fast-Rate Thermal Cycling ESS

Le DERUI DR-H204 rapid temperature change test chamber supports fast-rate thermal cycling and environmental stress screening while the specimen remains stationary. The published 800 L configuration offers selectable low-temperature ranges and cooling rates from 5°C/min to 25°C/min. Confirm the rate definition, temperature span and loaded performance in the approved technical agreement.

Modèle DR-H204
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 800 L · 1000 × 800 × 1000 mm
Temperature Options -20 / -40 / -70°C to +150°C
Published Ramp Rates Heating 5°C/min; cooling 5 / 10 / 15 / 25°C/min
Alimentation électrique Three-phase 380 V / 50 Hz
Before Quotation Confirm average/linear rate, span, specimen mass, powered heat, utilities and FAT method
Sûr et fiable
bien fabriqué
Assurance qualité
personnalisation
MessageWhatsApp
Numéro de hotline 15580327593
  • Détails du produit
  • Paramètres techniques
  • FAQ
  • Contactez-nous
Fast-Rate Thermal Cycling · ESS

DR-H204 Rapid Temperature Change Test Chamber

Run accelerated heating and cooling cycles for environmental stress screening of electronics, automotive components, aerospace assemblies and other temperature-sensitive products. The published 800 L configuration provides selectable low-temperature options and rapid cooling rates up to 25°C/min.

Rate definition matters: state whether the required ramp is average or linear, the start and end temperatures, air or specimen measurement, and the full powered load. A single “°C/min” value is not enough to size or accept an ESS chamber.
Published modelDR-H204
Published workspace800 L · 1000 × 800 × 1000 mm
Temperature options-20 / -40 / -70°C to +150°C
Published ratesHeat 5°C/min · Cool 5/10/15/25°C/min

Where Fast-Rate Thermal Cycling Fits

This chamber keeps the specimen stationary while the conditioned air follows a programmed ramp and dwell profile. It is designed for screening and thermal cycling—not the near-instant transfer exposure produced by a two- or three-zone thermal shock chamber.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Expose boards, modules, connectors and power electronics to repeated temperature transitions that help reveal assembly and material weaknesses.

Automotive and aerospace

Cycle controllers, sensors, lighting, avionics and compact assemblies using the applicable product or customer procedure.

Battery and energy systems

Evaluate non-abuse thermal-cycle performance only after specimen heat, electrical interfaces and the required safety scope are defined.

Published DR-H204 800L Configuration

Article Published value Procurement note
Internal workspace 1000 × 800 × 1000 mm; 800 L Confirm W × D × H and usable space after fixtures and airflow clearance.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 1580 × 1700 × 2260 mm Confirm installation, service and door-access clearances on the drawing.
Temperature range options -20 / -40 / -70°C to +150°C Select one refrigeration configuration for the required profile.
Fluctuation de température ±1°C Confirm setpoint, stabilized condition, sensor location and load.
Vitesse de chauffage 5°C/min Confirm average or linear definition, temperature span and load state.
Cooling rate options 5 / 10 / 15 / 25°C/min Confirm selected rate, temperature span, ambient, cooling utility and load.
Sample trays and port Three SUS304 trays; Φ50 mm test hole Confirm tray loading and whether port size/quantity suits the interfaces.
Alimentation électrique Three-phase 380 V / 50 Hz Rated current and power depend on the final refrigeration configuration.

Define the Ramp Before the Chamber Is Sized

Fix the endpoints

State the exact start and finish temperatures. A rate quoted across a narrow central span cannot be assumed across the full chamber range.

Choose the measurement basis

Specify chamber-air control, monitoring sensor positions and whether specimen temperature must follow the same slope.

Add the real load

Include specimen mass, fixture thermal mass, powered watts, duty cycle and cable heat leakage in the cooling calculation.

FAT basis: record the programmed and measured curves, rate calculation window, sensor map, stabilization rule and loaded or empty condition in the technical agreement.

Rapid Thermal Cycling Chamber Reference Image

DERUI DR-H204 rapid temperature change test chamber for fast-rate ESS thermal cycling

Current DERUI rapid temperature change chamber reference image. Final door, controller, ports and refrigeration arrangement follow the approved configuration.

Engineering Factors That Control Loaded Performance

Refrigeration capacity

The selected low-temperature end, cooling rate, test load and facility cooling conditions determine the required refrigeration system.

Heating and control

Heater capacity and control tuning must reproduce the programmed upward transition without unacceptable overshoot.

Airflow and fixture design

Specimen spacing and low-mass, open fixtures help conditioned air reach all surfaces and reduce local temperature lag.

Powered heat

Live electronics oppose the cooling system. Provide maximum continuous and transient watts rather than a nominal device rating.

Ports and interfaces

Define power, signals, thermocouples and communication cables so feedthroughs can be sized and sealed correctly.

Facility utilities

Confirm electrical supply, heat rejection, cooling-water conditions if applicable, drainage, ambient limits and service access.

Rapid Change Chamber vs. Thermal Shock Chamber

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Rapid temperature change chamber cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Remains stationary in one workspace. Typically transfers between separate hot and cold zones.
Exposure definition Controlled air ramp in °C/min with programmed dwells. Transfer time and recovery after zone change are central.
Powered monitoring Well suited when interfaces remain connected during cycling. Requires cable routing compatible with the transfer system.
Use when The procedure specifies a controlled temperature-change rate. The procedure requires abrupt zone transfer or thermal shock recovery.

Map the Chamber to the Test Method

The standard defines the exposure; the equipment does not create compliance by itself. Confirm the current edition, severity, test type and acceptance criteria.

Reference Typical relationship Confirm before claiming suitability
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Change of temperature methods Test designation, temperatures, transition, dwell and specimen operation.
MIL-STD-810H Tailored high/low temperature exposure Applicable method/procedure, rates, stabilization and functional checks.
JEDEC device methods Electronic component temperature cycling Exact JESD method, air profile, load, monitoring and lot acceptance.
Customer ESS profile Production screening Fault-detection goal, cycle count, test limits and data retention.

RFQ and FAT Checklist

Topic Information to provide or verify
Profile Start/end temperatures, rate definition, dwells, cycles and tolerances.
Specimen Envelope, mass, quantity, material, fixtures and powered heat.
Measurement Air/specimen sensors, sample rate, rate calculation and report format.
Interfaces Power, signals, thermocouples, network, test ports and safety interlocks.
Utilités Voltage, phase, current, cooling water if required, ambient and heat rejection.
FAT Empty/loaded condition, sensor map, ramps, dwells, alarms and acceptance limits.

Foire Aux Questions

What ramp rates are published for this DR-H204 page?

The current technical table lists 5°C/min heating and 5, 10, 15 or 25°C/min cooling. Confirm the selected rate, temperature span and whether it is average or linear in the quotation.

Does the published rate apply under full powered load?

The visible table does not establish one universal loaded guarantee. Provide fixture mass and maximum powered heat so loaded performance can be calculated and included in FAT criteria.

Is this the same as a thermal shock chamber?

No. A rapid change chamber controls a programmed air-temperature ramp while the specimen remains stationary. A thermal shock chamber typically transfers the specimen between separate zones.

Is humidity standard on the 800 L configuration?

The page discusses optional humidity, but the published 800 L technical table does not establish a confirmed humidity envelope for every rapid-rate configuration. Treat it as an option requiring a separate operating chart.

What power supply is published?

The current 800 L technical table states three-phase 380 V / 50 Hz. Final current and rated power depend on the selected temperature and ramp-rate configuration.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send the full profile, rate definition, specimen drawing and mass, fixture, powered heat, interfaces, facility utilities, standards and FAT requirements.

Configure the DR-H204 from the Loaded ESS Profile

Send the complete temperature cycle and specimen data. DERUI can confirm the low-temperature option, cooling rate, refrigeration capacity, interfaces, utilities and acceptance plan before quotation.

Request a Rapid ESS Chamber Review

FacebookLinkedInXRedditWhatsApp

Article

Spécification

Dimension intérieure (L*P*H)

1000*800*1000mm

Dimension extérieure (L*P*H)

1580*1700*2260mm

Capacité de travail

800 litres (peut être personnalisé)

Matériau de la chambre intérieure

Acier inoxydable SUS#304, finition miroir

Matériau de la chambre extérieure

acier inoxydable avec pulvérisation de peinture

Plage de température

-20/-40/-70℃~+150℃

Fluctuation de température

±1℃

Vitesse de chauffage

5℃/min、

Taux de refroidissement

5℃/min、10℃/min、15℃/min、25℃/min

Plateau d'échantillons

Acier inoxydable SUS#304, 3 pièces

Trou de test

diamètre 50mm, pour le passage de câble

Puissance

trois phases, 380V/50Hz

Dispositif de protection de sécurité

fuite

surchauffe

surtension et surcharge du compresseur

court-circuit du chauffage

Quels taux de montée offrent les chambres d'essai à changement rapide de température Derui pour le ESS ?

Nos chambres offrent des changements rapides de température jusqu'à 15°C par minute, idéaux pour le dépistage de stress environnemental (ESS). Ce taux de montée rapide permet de détecter les défauts précocement et d'accélérer votre processus de test.

Vos chambres sont-elles compatibles avec les tests d'humidité ?

Oui, beaucoup de nos chambres à cycle thermique rapide incluent un contrôle précis de l'humidité, permettant un cycle de température avec humidité pour simuler avec précision les conditions réelles.

Quels sont les délais de livraison typiques ?

Les modèles standard sont généralement expédiés en 6 à 8 semaines. Les configurations personnalisées peuvent prendre un peu plus de temps — généralement entre 10 et 12 semaines, selon vos spécifications.

Quelles options de garantie et de support sont disponibles ?

Nous garantissons nos chambres avec une garantie de 12 mois couvrant les pièces et la main-d'œuvre. De plus, nous offrons un support technique continu et des services de maintenance pour assurer le bon fonctionnement de votre équipement.

 

Qu'est-ce qu'une chambre d'essai à changement rapide de température ?
Une chambre d'essai à changement rapide de température est un équipement de test environnemental qui passe rapidement entre des températures extrêmes pour évaluer la résistance des produits au stress thermique. Elle est essentielle pour identifier les défaillances potentielles dans l'électronique, les composants automobiles et les pièces aéronautiques.

Quels taux de montée en température vos chambres peuvent-elles atteindre ?
Nos chambres offrent des changements rapides de température jusqu'à 15°C par minute, avec certaines configurations personnalisées atteignant des taux encore plus élevés. Ce test accéléré permet d'identifier plus rapidement les défauts des produits par rapport aux chambres conventionnelles.

Dans quels secteurs utilise-t-on des chambres à cycle de température rapide ?
Les principaux secteurs incluent l'électronique automobile, les composants aéronautiques, la fabrication de semi-conducteurs, les tests de batteries, les dispositifs médicaux et les équipements de télécommunications - partout où la fiabilité des produits sous stress thermique est critique.

 Comment votre chambre garantit-elle l'uniformité de la température ?
Nous utilisons des systèmes d'air avancés avec des conduits précisément conçus et des ventilateurs haute performance pour maintenir une uniformité de température dans ±1,5°C dans tout le volume de la chambre, assurant des conditions de test cohérentes.

À quelles normes vos chambres sont-elles conformes ?
Nos chambres respectent les principales normes internationales, notamment MIL-STD-810 pour les tests environnementaux, les normes JEDEC pour les tests de semi-conducteurs, IEC 60068-2-14 pour les tests de changement de température, et ISO 17025 pour la compétence des laboratoires.

Puis-je obtenir à la fois des tests de température et d'humidité dans une seule chambre ?
Oui, nous proposons des options de contrôle d'humidité intégrées allant de 10% à 95% HR, permettant un cycle combiné de température et d'humidité dans un seul système pour des tests environnementaux complets.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MessageMessage

Demandez un devis