Piso 1, No. 3, Avenida Shugang, Vila Hongmei, Cidade de Dongguan, Província de Guangdong, China

Fabricante de câmaras de teste ambiental há 20 anosMais de 3000 entregas a clientes em todo o mundo           Email: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Rapid Temperature Change Test Chamber Fast-Rate Thermal Cycling ESS

A DERUI DR-H204 rapid temperature change test chamber supports fast-rate thermal cycling and environmental stress screening while the specimen remains stationary. The published 800 L configuration offers selectable low-temperature ranges and cooling rates from 5°C/min to 25°C/min. Confirm the rate definition, temperature span and loaded performance in the approved technical agreement.

Modelo DR-H204
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 800 L · 1000 × 800 × 1000 mm
Temperature Options -20 / -40 / -70°C to +150°C
Published Ramp Rates Heating 5°C/min; cooling 5 / 10 / 15 / 25°C/min
Fonte de alimentação Three-phase 380 V / 50 Hz
Before Quotation Confirm average/linear rate, span, specimen mass, powered heat, utilities and FAT method
Seguro e fiável
bem construído
Garantia de qualidade
personalização
MensagemWhatsApp
Número de Linha Direta 15580327593
  • Detalhes do Produto
  • Parâmetros técnicos
  • Perguntas Frequentes
  • Contacte-nos
Fast-Rate Thermal Cycling · ESS

DR-H204 Rapid Temperature Change Test Chamber

Run accelerated heating and cooling cycles for environmental stress screening of electronics, automotive components, aerospace assemblies and other temperature-sensitive products. The published 800 L configuration provides selectable low-temperature options and rapid cooling rates up to 25°C/min.

Rate definition matters: state whether the required ramp is average or linear, the start and end temperatures, air or specimen measurement, and the full powered load. A single “°C/min” value is not enough to size or accept an ESS chamber.
Published modelDR-H204
Published workspace800 L · 1000 × 800 × 1000 mm
Temperature options-20 / -40 / -70°C to +150°C
Published ratesHeat 5°C/min · Cool 5/10/15/25°C/min

Where Fast-Rate Thermal Cycling Fits

This chamber keeps the specimen stationary while the conditioned air follows a programmed ramp and dwell profile. It is designed for screening and thermal cycling—not the near-instant transfer exposure produced by a two- or three-zone thermal shock chamber.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Expose boards, modules, connectors and power electronics to repeated temperature transitions that help reveal assembly and material weaknesses.

Automotive and aerospace

Cycle controllers, sensors, lighting, avionics and compact assemblies using the applicable product or customer procedure.

Battery and energy systems

Evaluate non-abuse thermal-cycle performance only after specimen heat, electrical interfaces and the required safety scope are defined.

Published DR-H204 800L Configuration

Item Published value Procurement note
Internal workspace 1000 × 800 × 1000 mm; 800 L Confirm W × D × H and usable space after fixtures and airflow clearance.
External dimensions 1580 × 1700 × 2260 mm Confirm installation, service and door-access clearances on the drawing.
Temperature range options -20 / -40 / -70°C to +150°C Select one refrigeration configuration for the required profile.
Variação de temperatura ±1°C Confirm setpoint, stabilized condition, sensor location and load.
Taxa de aquecimento 5°C/min Confirm average or linear definition, temperature span and load state.
Cooling rate options 5 / 10 / 15 / 25°C/min Confirm selected rate, temperature span, ambient, cooling utility and load.
Sample trays and port Three SUS304 trays; Φ50 mm test hole Confirm tray loading and whether port size/quantity suits the interfaces.
Fonte de alimentação Three-phase 380 V / 50 Hz Rated current and power depend on the final refrigeration configuration.

Define the Ramp Before the Chamber Is Sized

Fix the endpoints

State the exact start and finish temperatures. A rate quoted across a narrow central span cannot be assumed across the full chamber range.

Choose the measurement basis

Specify chamber-air control, monitoring sensor positions and whether specimen temperature must follow the same slope.

Add the real load

Include specimen mass, fixture thermal mass, powered watts, duty cycle and cable heat leakage in the cooling calculation.

FAT basis: record the programmed and measured curves, rate calculation window, sensor map, stabilization rule and loaded or empty condition in the technical agreement.

Rapid Thermal Cycling Chamber Reference Image

DERUI DR-H204 rapid temperature change test chamber for fast-rate ESS thermal cycling

Current DERUI rapid temperature change chamber reference image. Final door, controller, ports and refrigeration arrangement follow the approved configuration.

Engineering Factors That Control Loaded Performance

Refrigeration capacity

The selected low-temperature end, cooling rate, test load and facility cooling conditions determine the required refrigeration system.

Heating and control

Heater capacity and control tuning must reproduce the programmed upward transition without unacceptable overshoot.

Airflow and fixture design

Specimen spacing and low-mass, open fixtures help conditioned air reach all surfaces and reduce local temperature lag.

Powered heat

Live electronics oppose the cooling system. Provide maximum continuous and transient watts rather than a nominal device rating.

Ports and interfaces

Define power, signals, thermocouples and communication cables so feedthroughs can be sized and sealed correctly.

Facility utilities

Confirm electrical supply, heat rejection, cooling-water conditions if applicable, drainage, ambient limits and service access.

Rapid Change Chamber vs. Thermal Shock Chamber

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Rapid temperature change chamber Thermal shock chamber
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Remains stationary in one workspace. Typically transfers between separate hot and cold zones.
Exposure definition Controlled air ramp in °C/min with programmed dwells. Transfer time and recovery after zone change are central.
Powered monitoring Well suited when interfaces remain connected during cycling. Requires cable routing compatible with the transfer system.
Use when The procedure specifies a controlled temperature-change rate. The procedure requires abrupt zone transfer or thermal shock recovery.

Map the Chamber to the Test Method

The standard defines the exposure; the equipment does not create compliance by itself. Confirm the current edition, severity, test type and acceptance criteria.

Reference Typical relationship Confirm before claiming suitability
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Change of temperature methods Test designation, temperatures, transition, dwell and specimen operation.
MIL-STD-810H Tailored high/low temperature exposure Applicable method/procedure, rates, stabilization and functional checks.
JEDEC device methods Electronic component temperature cycling Exact JESD method, air profile, load, monitoring and lot acceptance.
Customer ESS profile Production screening Fault-detection goal, cycle count, test limits and data retention.

RFQ and FAT Checklist

Topic Information to provide or verify
Profile Start/end temperatures, rate definition, dwells, cycles and tolerances.
Specimen Envelope, mass, quantity, material, fixtures and powered heat.
Measurement Air/specimen sensors, sample rate, rate calculation and report format.
Interfaces Power, signals, thermocouples, network, test ports and safety interlocks.
Utilidades Voltage, phase, current, cooling water if required, ambient and heat rejection.
FAT Empty/loaded condition, sensor map, ramps, dwells, alarms and acceptance limits.

Perguntas Frequentes

What ramp rates are published for this DR-H204 page?

The current technical table lists 5°C/min heating and 5, 10, 15 or 25°C/min cooling. Confirm the selected rate, temperature span and whether it is average or linear in the quotation.

Does the published rate apply under full powered load?

The visible table does not establish one universal loaded guarantee. Provide fixture mass and maximum powered heat so loaded performance can be calculated and included in FAT criteria.

Is this the same as a thermal shock chamber?

No. A rapid change chamber controls a programmed air-temperature ramp while the specimen remains stationary. A thermal shock chamber typically transfers the specimen between separate zones.

Is humidity standard on the 800 L configuration?

The page discusses optional humidity, but the published 800 L technical table does not establish a confirmed humidity envelope for every rapid-rate configuration. Treat it as an option requiring a separate operating chart.

What power supply is published?

The current 800 L technical table states three-phase 380 V / 50 Hz. Final current and rated power depend on the selected temperature and ramp-rate configuration.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send the full profile, rate definition, specimen drawing and mass, fixture, powered heat, interfaces, facility utilities, standards and FAT requirements.

Configure the DR-H204 from the Loaded ESS Profile

Send the complete temperature cycle and specimen data. DERUI can confirm the low-temperature option, cooling rate, refrigeration capacity, interfaces, utilities and acceptance plan before quotation.

Request a Rapid ESS Chamber Review

FacebookLinkedInXRedditWhatsApp

Item

Especificação

Dimensão Interna (L*A*P)

1000*800*1000mm

Dimensão Externa (L*A*P)

1580*1700*2260mm

Capacidade de Trabalho

800 litros (pode ser personalizado)

Material da Câmara Interna

Aço inoxidável SUS#304, acabamento espelhado

Material da Câmara Externa

aço inoxidável com pulverização de tinta

Faixa de Temperatura

-20/-40/-70℃~+150℃

Variação de Temperatura

±1℃

Taxa de Aquecimento

5℃/min、

Taxa de Resfriamento

5℃/min、10℃/min、15℃/min、25℃/min

Bandeja de Amostras

aço inoxidável SUS#304, 3 peças

Orifício de Teste

diâmetro de 50mm, para roteamento de cabos

Potência

trifásico, 380V/50Hz

Dispositivo de Proteção de Segurança

fuga

sobretemperatura

sobretensão e sobrecarga do compressor

curto-circuito do aquecedor

Quais taxas de rampa as câmaras de mudança rápida de temperatura Derui oferecem para ESS?

Nossas câmaras proporcionam mudanças rápidas de temperatura até 15°C por minuto, ideal para Testes de Estresse Ambiental (ESS). Essa taxa de rampa rápida ajuda a detectar defeitos precocemente e acelera seu processo de teste.

As suas câmaras são compatíveis com testes de humidade?

Sim, muitas das nossas câmaras de ciclo térmico rápido incluem controlo de humidade preciso, permitindo ciclos de temperatura com humidade para simular condições do mundo real com precisão.

Quais são os tempos de entrega típicos?

Os modelos padrão normalmente enviam-se dentro de 4 a 6 semanas. Configurações personalizadas podem levar um pouco mais de tempo—tipicamente cerca de 5 a 8 semanas, dependendo das suas especificações.

Que opções de garantia e suporte estão disponíveis?

Apoiamos as nossas câmaras com uma garantia de 12 meses que cobre peças e mão-de-obra. Além disso, oferecemos suporte técnico contínuo e serviços de manutenção para manter o seu equipamento a funcionar sem problemas.

 

O que é uma câmara de teste de mudança rápida de temperatura?
Uma câmara de teste de mudança rápida de temperatura é um equipamento de teste ambiental que altera rapidamente entre temperaturas extremas para avaliar como os produtos resistem ao stress térmico. É essencial para identificar possíveis falhas em eletrónicos, componentes automóveis e peças aeroespaciais.

Que taxas de rampagem de temperatura as suas câmaras podem atingir?
As nossas câmaras proporcionam mudanças rápidas de temperatura até 15°C por minuto, com algumas configurações personalizadas a atingirem taxas ainda mais elevadas. Este teste acelerado ajuda a identificar defeitos nos produtos mais rapidamente do que câmaras convencionais.

Que indústrias utilizam câmaras de ciclo térmico rápido?
Indústrias-chave incluem eletrónica automóvel, componentes aeroespaciais, fabricação de semicondutores, testes de baterias, dispositivos médicos e equipamentos de telecomunicações—em qualquer lugar onde a fiabilidade do produto sob stress térmico seja crítica.

 Como é que a sua câmara garante a uniformidade de temperatura?
Utilizamos sistemas avançados de fluxo de ar com dutos precisamente projetados e ventiladores de alto desempenho para manter a uniformidade de temperatura dentro de ±1,5°C em todo o volume da câmara, garantindo condições de teste consistentes.

Com que padrões as suas câmaras cumprem?
As nossas câmaras cumprem os principais padrões internacionais, incluindo MIL-STD-810 para testes ambientais, padrões JEDEC para testes de semicondutores, IEC 60068-2-14 para testes de mudança de temperatura e ISO 17025 para competência laboratorial.

Posso obter testes de temperatura e humidade numa única câmara?
Sim, oferecemos opções integradas de controlo de humidade que variam de 10% a 95% RH, permitindo ciclos combinados de temperatura e humidade num único sistema para testes ambientais abrangentes.

WhatsAppWhatsApp