ห้องทดสอบจำลองระดับความสูงของแบตเตอรี่

The DERUI DR-D203 battery altitude simulation test chamber provides controlled low-pressure exposure for lithium cell and battery testing. Its 125 L workspace and 5.0–101.3 kPa absolute-pressure range include the 11.6 kPa condition used in UN 38.3 T.1. This is a low-pressure-only chamber; the laboratory maintains and records the required ambient temperature separately.

รุ่นDR-D203 battery low-pressure chamber
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits500 × 500 × 500 mm (W × D × H), 125 L
ช่วงแรงดัน5.0–101.3 kPa absolute; UN 38.3 T.1 reference condition: 11.6 kPa or less
ControlE600 7-inch touchscreen; automatic pressure and hold-time settings; time-stamped pressure recording and export
อุณหภูมิNo built-in heating or cooling; laboratory ambient condition is maintained and documented separately
การใช้งานBattery low-pressure exposure and UN 38.3 T.1 test planning; the complete test and report remain the laboratory’s responsibility

ปลอดภัยและเชื่อถือได้
คุณภาพดี
การรับประกันคุณภาพ
การปรับแต่ง
ข้อความWhatsApp
หมายเลขสายด่วน 15580327593
  • รายละเอียดสินค้า
  • พารามิเตอร์ทางเทคนิค
  • คำถามที่พบบ่อย
  • ติดต่อเรา
DR-D203 · Battery Low-Pressure Chamber

125 L Battery Altitude Simulation Test Chamber

Specify a controlled absolute-pressure hold for battery transport testing without paying for an unneeded heating and refrigeration system. The revised DR-D203 has a 500 × 500 × 500 mm workspace, a 5.0–101.3 kPa absolute-pressure range and automatic vacuum control through a 7-inch touchscreen.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits500 × 500 × 500 mm · 125 L
Absolute pressure5.0–101.3 kPa
Test focusLow-pressure exposure, including the 11.6 kPa T.1 condition

What this chamber is—and is not

DR-D203 is a low-pressure altitude simulation chamber for cells, batteries and other specimens whose test plan calls for reduced air pressure. It does not include active heating or refrigeration. For UN 38.3 T.1, the laboratory must maintain and document the required 20 ± 5 °C ambient condition independently; a pressure-capable chamber alone does not certify a test result.

Do not substitute this model for a temperature-altitude chamber. Simultaneous programmed hot/cold and low-pressure exposure requires a separately specified system. The observation window and door restraint are standard construction features, not a verified thermal-runaway containment rating.

DR-D203 technical specifications

พารามิเตอร์ 125 L configuration
Internal workspace 500 × 500 × 500 mm (W × D × H), 125 L geometric volume; two levels with two mesh shelves
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Approximately 800 × 750 × 1480 mm (W × D × H); final unit governs
ช่วงแรงดัน 5.0–101.3 kPa absolute; minimum 5.0 kPa
Pressure control accuracy At ≤5 kPa: ±0.5 kPa; above 5–40 kPa: ±1 kPa; above 40–80 kPa: ±2 kPa. Confirm the agreed acceptance point and test conditions in the order.
Pressure release rate 15 ± 3 kPa/min
Control and sensing E600 Youyi 7-inch touchscreen; diffused-silicon pressure sensor; automatic upper/lower pressure limits, hold time, end-of-test venting and alarm settings
Data record Time-stamped pressure curve and export included in the confirmed standard configuration; request the file format, sampling interval and FAT demonstration in the order.
Chamber structure 4.0 mm SUS304 stainless-steel reinforced interior; 1.2 mm powder-coated cold-rolled steel exterior; rock-wool infill; high-temperature silicone door seal
Window and door 19 mm tempered-glass window, 250 × 300 mm; door restraint chain
Vacuum pump Daertuo VP750; 220 V / 0.25 kW motor; pump noise ≤75 dB as supplied specification
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Emergency stop, pressure-limit protection, pressure-reducing valve, automatic and manual venting, grounding and fast fuse; protection scope must be checked against the actual battery hazard assessment
Power and weight 220 V / 50 Hz, rated equipment power 2 kW; approximately 250 kg
การบำรุงรักษา Replaceable custom door seal; vacuum-pump oil replacement and routine pump service

Product quotation, drawings and factory acceptance results govern the delivered unit.

How to specify a UN 38.3 T.1 setup

Test profileIdentify the adopted Manual edition, absolute-pressure target at or below 11.6 kPa, required hold, test sequence and laboratory ambient-temperature record.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limitsProvide chemistry, dimensions, mass, quantity, state of charge and condition. Shelf load limits and usable clearance must be approved before loading.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limitsAgree on pressure/temperature instruments, calibration evidence, exported traces, observations and before/after measurements needed by the laboratory.

This equipment supports the low-pressure portion of a test program; it does not itself confer UN 38.3 approval. Confirm the applicable method and reporting criteria with your laboratory.

Standard safety equipment and operating limits

The confirmed standard configuration includes an emergency stop, pressure protection, pressure-reducing valve, automatic end-of-test release and manual venting. A 19 mm tempered-glass window and side-mounted door restraint are also fitted. The vacuum pump has an exhaust outlet. None of these statements establishes a rated capability to contain battery fire, explosion or thermal runaway.

The standard chamber has no confirmed powered-test feedthrough. Keep specimens unpowered during a standard T.1 storage exposure unless a separately engineered configuration and approved procedure explicitly require otherwise. Gas detection, fire interfaces and laboratory exhaust treatment must be evaluated for the specimen and facility; do not assume they are included.

Real DR-D203 equipment photograph

UN 38.3 T.1 lithium battery altitude simulation workflow from low pressure exposure to result evaluation

Common selection questions

Does the DR-D203 control temperature?

No. It is a low-pressure-only chamber without active heating or cooling. The laboratory must establish and document the ambient condition required by its test procedure.

Is a 5.0 kPa minimum enough for UN 38.3 T.1?

The specified pressure range includes the T.1 target of 11.6 kPa absolute or less. Whether a particular test is valid also depends on duration, ambient condition, samples, measurements and the adopted method edition.

Can the chamber generate a compliant test report by itself?

No. Its standard pressure-trace export supports evidence collection, while the laboratory remains responsible for calibration, sample identification, observations, electrical measurements and the complete report.

Configure the chamber for your test plan

Send the required standard edition, specimen details, pressure profile, lab ambient conditions and reporting requirements. DERUI can confirm the delivered configuration, shelf capacity, safety scope and factory acceptance points before quotation.

Request a DR-D203 configuration review

เฟซบุ๊กLinkedInXRedditWhatsApp
รุ่น DR-D203
ขนาดกล่องภายใน ขนาด 400*400*400 มม. (กว้าง*ลึก*สูง)
ขนาดอุปกรณ์ ขนาด 630*620*1130 มม. (กว้าง*ลึก*สูง)
วัสดุกล่องใน แผ่นสแตนเลส SUS304 หนา 3.0 มม.
วัสดุกล่องนอก แผ่นเหล็กรีดเย็นเคลือบสีด้วยการอบ, หนา 1.5 มม.
หน้าต่างชม ขนาด 250*250 มม. กระจกเทมเปอร์สองชั้น หน้าต่างโปร่งใสพร้อมตะแกรงสแตนเลส
ความคล่องตัวของอุปกรณ์ ด้านล่างของอุปกรณ์มีล้อยูเนอร์แวส 4 ล้อ ซึ่งสามารถเคลื่อนย้ายได้อย่างอิสระ
ช่วงแรงดัน 0.5-100 กิโลปาสกาล, ความดันอากาศทดสอบที่ใช้บ่อย 11.6 กิโลปาสกาล
แสดงระดับสุญญากาศ เครื่องวัด SMC แบบดิจิตอลแสดงผล
วิธีควบคุม ควบคุมด้วยปุ่มกด
นาฬิกาจับเวลา จอแสดงผลดิจิตอล LED ตั้งค่าได้อิสระในช่วง 0-9999 ชั่วโมง
ความผันผวนของแรงดัน ≤5%
ประตูกล่อง ประตูเดี่ยวเปิดซ้ายพร้อมโซ่กันระเบิดด้านข้างของประตู
ถาดเก็บของ 2
น้ำหนักอุปกรณ์ 130กก.
แหล่งจ่ายไฟ ไฟฟ้า 220V
ไฟฟ้า 1กิโลวัตต์

1、เครื่องทดสอบจำลองระดับความสูงของแบตเตอรี่คืออะไร?
เป็นห้องทดสอบเฉพาะทางที่ออกแบบมาเพื่อทดสอบแบตเตอรี่ภายใต้สภาพจำลองระดับความสูงต่าง ๆ.

2、การทำงานของการจำลองระดับความสูงเป็นอย่างไร?
ห้องใช้เซ็นเซอร์และระบบควบคุมที่แม่นยำเพื่อจำลองสภาพระดับความสูงต่าง ๆ เพื่อการทดสอบที่แม่นยำ.

3、ทำไมการทดสอบระดับความสูงจึงสำคัญสำหรับแบตเตอรี่?
การทดสอบระดับความสูงเป็นสิ่งสำคัญเพื่อเข้าใจสมรรถนะและความน่าเชื่อถือของแบตเตอรี่ในสภาพแวดล้อมที่แตกต่างกัน.

4. สามารถทดสอบประเภทแบตเตอรี่ใดได้บ้าง?
ห้องสามารถทดสอบแบตเตอรี่หลายประเภท รวมถึงลิเธียมไอออน, นิกเกิลเมทัลไฮไดรด์ และอื่น ๆ.

5、รวมการควบคุมอุณหภูมิด้วยหรือไม่?
ใช่ ห้องของเรามีการจัดการความร้อนขั้นสูงเพื่อรักษาอุณหภูมิการทดสอบที่เหมาะสม.

6、ฉันสามารถปรับแต่งโปรไฟล์การทดสอบได้หรือไม่?
แน่นอน! ห้องสามารถปรับแต่งการตั้งค่าการทดสอบให้เหมาะสมกับประเภทแบตเตอรี่เฉพาะ.

7、มีคุณสมบัติด้านความปลอดภัยอะไรบ้าง?
กลไกความปลอดภัยรวมถึงระบบปิดฉุกเฉิน, การป้องกันแรงดันเกิน และการระบายอากาศที่ครอบคลุม.

8、การติดตั้งซับซ้อนหรือไม่?
การติดตั้งเป็นเรื่องง่าย และผู้เชี่ยวชาญของเรามีการสนับสนุนเพื่อให้แน่ใจว่าการตั้งค่าถูกต้อง.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
ข้อความข้อความ

ขอใบเสนอราคา