غرفة رطوبة عالية مزدوجة 85

ال DERUI DR-H201-D85 Double 85 high humidity chamber provides controlled 85°C and 85% RH exposure for electronics, semiconductors, automotive components, photovoltaic products and materials. Five published capacities support specimen-level and batch reliability testing.

Series DR-H201-D85
Core Condition 85°C temperature + 85% relative humidity
Published Capacities 100 / 150 / 225 / 408 / 1000 L
Typical Use Steady damp-heat, THB and product-specific 85/85 reliability testing
Key Selection Basis Loaded workspace, sample quantity, bias/power, duration and monitoring
Before Quotation Confirm standard, specimen state, interfaces, utilities and FAT criteria
آمن وموثوق
مصنوع بشكل جيد
ضمان الجودة
تخصيص
رسالةواتساب
رقم الخط الساخن 15580327593
  • تفاصيل المنتج
  • الأسئلة الشائعة
  • المعلمات الفنية
  • اتصل بنا
85°C / 85% RH Constant Damp Heat

DR-H201-D85 Double 85 High Humidity Chamber

Run controlled 85°C and 85% RH exposure for electronics, semiconductor devices, automotive components, photovoltaic modules and material systems. The DR-H201-D85 series provides five published workspace sizes for steady damp-heat reliability testing.

Double 85 is a condition, not a complete test method: duration, specimen bias or powered state, stabilization, monitoring and pass/fail criteria must come from the applicable standard or approved test plan.
Core condition85°C + 85% RH
Published models100 / 150 / 225 / 408 / 1000 L
SeriesDR-H201-D85
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limitsConstant damp-heat reliability exposure

What Double 85 Testing Reveals

Sustained heat and moisture can accelerate moisture ingress, corrosion, insulation decline, delamination and material-interface failures. The chamber provides the exposure; the product standard determines how results are evaluated.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Investigate package moisture resistance, corrosion, leakage-current changes and biased damp-heat reliability.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Evaluate connectors, sensors, control electronics, coatings and seals under prolonged hot-humid stress.

Photovoltaic materials

Support damp-heat exposure of modules or materials when workspace, loading, duration and IEC 61215 procedure are confirmed.

Published DR-H201-D85 Model Matrix

الموديل Internal size W × H × D Low-temperature options Published supply
DR-H201-D85-100 400 × 500 × 500 mm -20 / -40 / -70°C Single-phase 220 V
DR-H201-D85-150 500 × 500 × 600 mm -20 / -40 / -70°C Single-phase 220 V
DR-H201-D85-225 500 × 750 × 600 mm -20 / -40 / -70°C Three-phase 380 V
DR-H201-D85-408 600 × 850 × 800 mm -20 / -40 / -70°C Three-phase 380 V
DR-H201-D85-1000 cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits -20 / -40 / -70°C Three-phase 380 V
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits select the low-temperature option only if the wider programme requires it. A dedicated 85/85 exposure does not itself require -40°C or -70°C capability.

Build a Defensible 85/85 Test Plan

Define conditioning

State specimen preparation, preconditioning and whether the device is unbiased, biased or continuously powered.

Define exposure

Specify 85°C/85% RH duration, stabilization rule, monitoring interval, interruptions and allowed tolerances.

Define evaluation

Document electrical, optical, mechanical or visual measurements and the exact failure criteria.

Double 85 Chamber Reference Image

DERUI DR-H201-D85 double 85 high humidity chamber for 85°C 85% RH testing

DERUI Double 85 high-humidity chamber reference image. Final workspace, controller, ports and supply follow the approved model configuration.

Loading Practices That Protect Uniformity

Keep air paths open

Leave clearance between samples and avoid blocking supply or return air with trays, fixtures or large panels.

Control specimen density

Define batch quantity, mass and moisture absorption because a crowded load changes recovery and local RH.

Seal cable entries

Specify bias wiring and sensor leads, then seal unused port area to limit room-air leakage.

Use appropriate water

Follow the approved water-quality, tank/feed, cleaning and drainage requirements for the humidification system.

Manage condensation

Use the prescribed ramp and post-test handling sequence; uncontrolled door opening can add non-test condensation.

Record interruptions

Document alarms, door openings, water events and deviations that may affect the validity of long exposures.

Match the Chamber to the Applicable Method

Reference Typical relationship Do not assume
IEC 60068-2-78 Steady-state damp heat That every product uses 85°C/85% RH or the same duration.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits PV module damp-heat qualification That chamber capability alone proves module compliance.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Steady-state temperature-humidity bias testing That bias circuits, monitoring and failure criteria are automatically included.
Customer/automotive specification Product-specific reliability exposure That “Double 85” defines sample state, duration or acceptance.

RFQ and FAT Checklist

Topic Information to provide or verify
Specimen Dimensions, mass, quantity, material, rack and airflow clearance.
Test plan Standard/edition, 85/85 duration, bias, monitoring and pass/fail criteria.
Interfaces Power, signals, thermocouples, test ports and external measurement equipment.
المرافق Voltage, phase, current, water quality, drainage and ambient conditions.
FAT Sensor map, 85/85 stabilization, deviation, uniformity, records and report format.
Documents Approved drawing, configuration list, manuals, calibration scope and acceptance report.

الأسئلة المتكررة

What does Double 85 mean?

It refers to exposure at 85°C and 85% relative humidity. It does not by itself define duration, specimen operation or acceptance criteria.

Which chamber size should I choose?

Select from the complete loaded envelope, fixture, sample quantity and airflow clearance—not nominal litres alone.

Does every Double 85 test run for 1,000 hours?

No. Some procedures use long exposures, but the applicable standard or customer plan must define duration and interruptions.

Can samples be electrically biased?

Yes when the configuration includes suitable feedthroughs and the approved plan defines bias, monitoring, heat and safety requirements.

Does this chamber certify IEC 61215 compliance?

No chamber alone certifies a product. It can provide the required damp-heat exposure when configuration, calibration, loading and procedure meet the applicable method.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send the standard, specimen size and quantity, exposure duration, bias/power, interfaces, workspace, utilities and FAT requirements.

Configure the Double 85 Chamber Around the Test Plan

Send the specimen layout, 85°C/85% RH duration, powered or biased state, monitoring points and acceptance criteria. DERUI can confirm model size, interfaces, utilities and FAT scope.

Request a Double 85 Chamber Review

فيسبوكلينكدإنXريديتواتساب

س: ما هو استخدام غرفة الرطوبة العالية من طراز مزدوج 85؟

ج: يُستخدم بشكل رئيسي لاختبار الموثوقية من خلال محاكاة ظروف درجة حرارة 85°C ورطوبة نسبية 85%. يساعد ذلك في التحقق من مدى تحمل المنتجات مثل الإلكترونيات، وقطع السيارات، ووحدات الطاقة الشمسية في بيئات قاسية ورطبة.

س: كيف يختلف اختبار غرفة مزدوج 85 (85/85) عن غرف البيئة الأخرى؟

ج: تركز غرفة مزدوج 85 على درجة حرارة ورطوبة عالية ثابتة، مما يسرع اختبارات الشيخوخة للتنبؤ بعمر المنتج تحت ضغط الرطوبة والحرارة — وهو شيء لا تحاكيه الغرف القياسية بدقة أكبر.

س: ما هي الصناعات التي تستفيد من استخدام هذه الغرف؟

ج: تصنيع الإلكترونيات، واختبار مكونات السيارات، وتأهيل وحدات الطاقة الشمسية، وتطوير البطاريات، واختبار موثوقية الأجهزة الطبية تعتمد بشكل كبير على غرف مزدوج 85.

س: هل يمكن تخصيص الغرفة لأحجام عينات مختلفة؟

ج: نعم، تقدم ديروي أحجام غرف متنوعة وخيارات تخصيص لتتناسب مع أحجام الاختبار المختلفة، وسرعات الاختبار، وحتى نطاقات الرطوبة إذا كانت اختباراتك تتطلب رطوبة منخفضة أو إنتاجية عالية.

س: ما هي المعايير التي تلتزم بها غرفة مزدوج 85 من ديروي؟

ج: تلبي غرفنا المعايير الصناعية الرئيسية مثل IEC 60068، ASTM، وبروتوكولات موثوقية السيارات بما في ذلك تلك الخاصة بوحدات الطاقة الشمسية وفقًا لـ IEC 61215.

س: ما مدى كفاءة الطاقة لهذه الغرف؟

ج: تصمم شركة ديروي غرفها بعزل متين وأنظمة توفير للطاقة، بحيث تعمل بكفاءة دون المساس بدقة أو اتساق الاختبار.

س: ما الصيانة اللازمة لنظام الرطوبة العالية؟

ج: المعايرة الدورية، وتنظيف نظام الترطيب، ومراقبة التكاثف هي خطوات أساسية. توفر شركة ديروي أدلة مفصلة ودعمًا للحفاظ على تشغيل غرفتك بسلاسة.

س: كم من الوقت يمكنني بدء الاختبار بعد التركيب؟

ج: بعد الإعداد والمعايرة المهنيين، يمكنك عادةً بدء الاختبار الدقيق خلال يوم أو يومين، لضمان تساوي درجة الحرارة والرطوبة داخل الغرفة.

الموديل

DR-H201-D85-100

DR-H201-D85-150

DR-H201-D85-225

DR-H201-D85-408

DR-H201-D85-1000

الأبعاد الداخلية (عرض*ارتفاع*عمق)

400*500*500مم

500*500*600مم

500*750*600مم

600*850*800مم

1000*1000*800مم

الأبعاد الخارجية (نوع SUS) (عرض*ارتفاع*عمق)

950*1400*1100مم

1100*1500*1100مم

1100*1670*1200مم

1200*1770*1400مم

1550*2100*1400مم

الأبعاد الخارجية (نوع الطلاء) (عرض*ارتفاع*عمق)

700*1400*1100مم

800*1500*1100مم

800*1670*1200مم

900*1770*1400مم

1550*2100*1400مم

درجة الحرارة(℃)

-20/-40/-70

-20/-40/-70

-20/-40/-70

-20/-40/-70

-20/-40/-70

الطاقة الإجمالية(كيلوواط)

4.5/4.5/6.5

5/5/6.5

9.5/9.5/11.6

9.5/9.5/11.6

17/17/21.5

التيار الأقصى(أ)

25/25/32

32/32/40

25/32/40

32

50/50/60

الجهد(فولت)

تيار أحادي الطور 220 فولت

تيار أحادي الطور 220 فولت

ثلاثي الطور 380 فولت

ثلاثي الطور 380 فولت

ثلاثي الطور 380 فولت

واتسابواتساب
واتسابواتساب
واتساب
رسالةرسالة

اطلب عرض سعر