Cámara de alta humedad doble 85

La DERUI DR-H201-D85 Double 85 high humidity chamber provides controlled 85°C and 85% RH exposure for electronics, semiconductors, automotive components, photovoltaic products and materials. Five published capacities support specimen-level and batch reliability testing.

Series DR-H201-D85
Core Condition 85°C temperature + 85% relative humidity
Published Capacities 100 / 150 / 225 / 408 / 1000 L
Typical Use Steady damp-heat, THB and product-specific 85/85 reliability testing
Key Selection Basis Loaded workspace, sample quantity, bias/power, duration and monitoring
Before Quotation Confirm standard, specimen state, interfaces, utilities and FAT criteria
Segura y confiable
bien hecha
Garantía de calidad
personalización
MensajeWhatsApp
Número de línea directa 15580327593
  • Detalles del producto
  • Preguntas frecuentes
  • Parámetros técnicos
  • Contáctanos
85°C / 85% RH Constant Damp Heat

DR-H201-D85 Double 85 High Humidity Chamber

Run controlled 85°C and 85% RH exposure for electronics, semiconductor devices, automotive components, photovoltaic modules and material systems. The DR-H201-D85 series provides five published workspace sizes for steady damp-heat reliability testing.

Double 85 is a condition, not a complete test method: duration, specimen bias or powered state, stabilization, monitoring and pass/fail criteria must come from the applicable standard or approved test plan.
Core condition85°C + 85% RH
Published models100 / 150 / 225 / 408 / 1000 L
SeriesDR-H201-D85
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limitsConstant damp-heat reliability exposure

What Double 85 Testing Reveals

Sustained heat and moisture can accelerate moisture ingress, corrosion, insulation decline, delamination and material-interface failures. The chamber provides the exposure; the product standard determines how results are evaluated.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Investigate package moisture resistance, corrosion, leakage-current changes and biased damp-heat reliability.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Evaluate connectors, sensors, control electronics, coatings and seals under prolonged hot-humid stress.

Photovoltaic materials

Support damp-heat exposure of modules or materials when workspace, loading, duration and IEC 61215 procedure are confirmed.

Published DR-H201-D85 Model Matrix

Modelo Internal size W × H × D Low-temperature options Published supply
DR-H201-D85-100 400 × 500 × 500 mm -20 / -40 / -70°C Single-phase 220 V
DR-H201-D85-150 500 × 500 × 600 mm -20 / -40 / -70°C Single-phase 220 V
DR-H201-D85-225 500 × 750 × 600 mm -20 / -40 / -70°C Three-phase 380 V
DR-H201-D85-408 600 × 850 × 800 mm -20 / -40 / -70°C Three-phase 380 V
DR-H201-D85-1000 cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits -20 / -40 / -70°C Three-phase 380 V
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits select the low-temperature option only if the wider programme requires it. A dedicated 85/85 exposure does not itself require -40°C or -70°C capability.

Build a Defensible 85/85 Test Plan

Define conditioning

State specimen preparation, preconditioning and whether the device is unbiased, biased or continuously powered.

Define exposure

Specify 85°C/85% RH duration, stabilization rule, monitoring interval, interruptions and allowed tolerances.

Define evaluation

Document electrical, optical, mechanical or visual measurements and the exact failure criteria.

Double 85 Chamber Reference Image

DERUI DR-H201-D85 double 85 high humidity chamber for 85°C 85% RH testing

DERUI Double 85 high-humidity chamber reference image. Final workspace, controller, ports and supply follow the approved model configuration.

Loading Practices That Protect Uniformity

Keep air paths open

Leave clearance between samples and avoid blocking supply or return air with trays, fixtures or large panels.

Control specimen density

Define batch quantity, mass and moisture absorption because a crowded load changes recovery and local RH.

Seal cable entries

Specify bias wiring and sensor leads, then seal unused port area to limit room-air leakage.

Use appropriate water

Follow the approved water-quality, tank/feed, cleaning and drainage requirements for the humidification system.

Manage condensation

Use the prescribed ramp and post-test handling sequence; uncontrolled door opening can add non-test condensation.

Record interruptions

Document alarms, door openings, water events and deviations that may affect the validity of long exposures.

Match the Chamber to the Applicable Method

Reference Typical relationship Do not assume
IEC 60068-2-78 Steady-state damp heat That every product uses 85°C/85% RH or the same duration.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits PV module damp-heat qualification That chamber capability alone proves module compliance.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Steady-state temperature-humidity bias testing That bias circuits, monitoring and failure criteria are automatically included.
Customer/automotive specification Product-specific reliability exposure That “Double 85” defines sample state, duration or acceptance.

RFQ and FAT Checklist

Topic Information to provide or verify
Specimen Dimensions, mass, quantity, material, rack and airflow clearance.
Test plan Standard/edition, 85/85 duration, bias, monitoring and pass/fail criteria.
Interfaces Power, signals, thermocouples, test ports and external measurement equipment.
Servicios públicos Voltage, phase, current, water quality, drainage and ambient conditions.
FAT Sensor map, 85/85 stabilization, deviation, uniformity, records and report format.
Documents Approved drawing, configuration list, manuals, calibration scope and acceptance report.

Preguntas Frecuentes

What does Double 85 mean?

It refers to exposure at 85°C and 85% relative humidity. It does not by itself define duration, specimen operation or acceptance criteria.

Which chamber size should I choose?

Select from the complete loaded envelope, fixture, sample quantity and airflow clearance—not nominal litres alone.

Does every Double 85 test run for 1,000 hours?

No. Some procedures use long exposures, but the applicable standard or customer plan must define duration and interruptions.

Can samples be electrically biased?

Yes when the configuration includes suitable feedthroughs and the approved plan defines bias, monitoring, heat and safety requirements.

Does this chamber certify IEC 61215 compliance?

No chamber alone certifies a product. It can provide the required damp-heat exposure when configuration, calibration, loading and procedure meet the applicable method.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send the standard, specimen size and quantity, exposure duration, bias/power, interfaces, workspace, utilities and FAT requirements.

Configure the Double 85 Chamber Around the Test Plan

Send the specimen layout, 85°C/85% RH duration, powered or biased state, monitoring points and acceptance criteria. DERUI can confirm model size, interfaces, utilities and FAT scope.

Request a Double 85 Chamber Review

FacebookLinkedInXRedditWhatsApp

P: ¿Para qué se utiliza una cámara de alta humedad Double 85?

R: Se utiliza principalmente para pruebas de fiabilidad simulando condiciones de temperatura de 85°C y humedad relativa de 85%. Esto ayuda a verificar cómo productos como electrónica, piezas automotrices y módulos fotovoltaicos resisten en ambientes húmedos y adversos.

P: ¿En qué se diferencia la cámara de prueba Double 85 (85/85) de otras cámaras ambientales?

R: La cámara Double 85 se centra en mantener alta temperatura y humedad constantes, acelerando las pruebas de envejecimiento para predecir la vida útil del producto bajo estrés de calor húmedo—algo que las cámaras estándar no simulan con tanta precisión.

P: ¿Qué industrias se benefician del uso de estas cámaras?

R: La fabricación de electrónica, la prueba de componentes automotrices, la calificación de módulos fotovoltaicos, el desarrollo de baterías y las pruebas de fiabilidad de dispositivos médicos dependen en gran medida de las cámaras Double 85.

P: ¿Se puede personalizar la cámara para diferentes tamaños de muestras?

R: Sí, Derui ofrece varias opciones de tamaño y personalización para adaptarse a diferentes volúmenes, velocidades de prueba e incluso rangos de humedad si tus pruebas requieren baja humedad relativa o alto rendimiento.

P: ¿Con qué estándares cumple la cámara Double 85 de Derui?

R: Nuestras cámaras cumplen con estándares clave de la industria como IEC 60068, ASTM y protocolos de fiabilidad automotriz, incluyendo aquellos para módulos fotovoltaicos bajo IEC 61215.

P: ¿Qué tan eficientes en energía son estas cámaras?

R: Derui diseña sus cámaras con aislamiento duradero y sistemas de ahorro energético, por lo que funcionan de manera eficiente sin comprometer la precisión o consistencia de las pruebas.

P: ¿Qué mantenimiento requieren los sistemas de alta humedad?

A: La calibración de rutina, la limpieza del sistema de humidificación y la monitorización de la condensación son pasos esenciales. Derui proporciona guías detalladas y soporte para mantener su cámara funcionando sin problemas.

P: ¿Cuánto tiempo tarda en poder comenzar las pruebas después de la instalación?

A: Después de una configuración y calibración profesionales, generalmente puede comenzar pruebas precisas en uno o dos días, asegurando una temperatura y humedad uniformes dentro de la cámara.

Modelo

DR-H201-D85-100

DR-H201-D85-150

DR-H201-D85-225

DR-H201-D85-408

DR-H201-D85-1000

Dimensión interna (An*Al*Prof)

400*500*500mm

500*500*600mm

500*750*600mm

600*850*800mm

1000*1000*800mm

Dimensión externa (tipo sus) (An*Al*Prof)

950*1400*1100mm

1100*1500*1100mm

1100*1670*1200mm

1200*1770*1400mm

1550*2100*1400mm

Dimensión Externa (Tipo de pintura) (An*Al*Pr)

700*1400*1100mm

800*1500*1100mm

800*1670*1200mm

900*1770*1400mm

1550*2100*1400mm

Temperatura (℃)

-20/-40/-70

-20/-40/-70

-20/-40/-70

-20/-40/-70

-20/-40/-70

Potencia Total (kw)

4.5/4.5/6.5

5/5/6.5

9.5/9.5/11.6

9.5/9.5/11.6

17/17/21.5

Corriente Máxima (A)

25/25/32

32/32/40

25/32/40

32

50/50/60

Voltaje (A)

Corriente Monofásica 220V

Corriente Monofásica 220V

Corriente Trifásica 380V

Corriente Trifásica 380V

Corriente Trifásica 380V

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MensajeMensaje

Solicitar una Cotización