The DR-H201-F3000 is a custom 3,000 L climate-chamber project for large test loads. Define the specimen, environmental duty, external test systems and facility protection interfaces as one coordinated equipment scope.
DR-H201-F3000
Designed Around Large Loads, Not an Empty Chamber
Battery modules and packs
Provide specimen envelope, mass, state of charge, maximum electrical energy and powered heat so airflow and refrigeration capacity can be sized correctly.
Multiple specimens or fixtures
Define rack layout, clearances, cable routing and loading method. A nominal 3,000 L volume does not equal 3,000 L of usable specimen space.
Integrated test systems
Specify cycler connections, voltage and temperature channels, gas sampling, video, exhaust and data interfaces before the chamber layout is released.
DR-H201-F3000
DR-H201-F3000 Configuration
| عنصر | المواصفة | Project confirmation |
|---|---|---|
| Model / nominal volume | DR-H201-F3000 / 3,000 L | Confirm usable internal dimensions and door opening on the approved drawing. |
| نطاق درجة الحرارة | من -70 درجة مئوية إلى +150 درجة مئوية | Confirm required option, load, setpoint span and stabilization criteria. |
| توحيد درجة الحرارة | ±2°C | Confirm whether this means deviation or uniformity, sensor map and loaded/no-load condition. |
| نطاق الرطوبة | 10% إلى 98% RH | Request the combined temperature-humidity operating envelope; full RH range is not available at every temperature. |
| Heating / cooling rate | up to 5°C/min / 3°C/min | Define average or linear rate, start/end points, specimen load and cooling-water condition. |
| مصدر الطاقة | 220 V or 380 V, 50/60 Hz; customized | Freeze voltage, phase, frequency, connected load and protective device. |
| Internal / external material | Stainless-steel interior / reinforced coated-steel exterior | Confirm grade, thickness, floor loading and corrosion requirements. |
| External dimensions | Customized for installation | Confirm transport route, doorway, service clearance and maintenance access. |
DR-H201-F3000
Freeze the Non-Standard Design Inputs First
Define the climate duty
List temperature and RH setpoints, transitions, dwell times, cycles, tolerances and recovery requirements.
Define the real load
Provide dimensions, mass, quantity, fixtures, packaging, powered heat, cable loss and expected failure modes.
Define the facility interface
Confirm electrical supply, cooling water, drain, exhaust route, fire-system interface, room ambient and installation access.
DR-H201-F3000
Safety Functions Must Follow the Hazard Analysis
| Function | Information required before selection | Acceptance evidence |
|---|---|---|
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | Credible pressure event, relief direction, safe discharge area and facility clearance | Approved calculation/drawing and functional inspection |
| Gas, smoke or flame detection | Target hazard, sensor type/range, alarm thresholds and calibration | Calibration record and cause-and-effect test |
| Forced exhaust | Required airflow, duct material, discharge point, make-up air and purge time | Measured airflow and interlock demonstration |
| Fire suppression | Agent, design concentration, activation logic, drainage and local-code approval | Approved system documents and functional test |
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | Specimen power, chamber shutdown sequence, emergency stop and fail-safe state | Interlock matrix and witnessed shutdown test |
| Reinforced enclosure | Defined event, structural design basis, door/window/port construction | Drawing review and agreed project-specific verification |
DR-H201-F3000
DR-H201-F3000 Product View

Product view. Internal layout, ports and protection functions follow the approved project drawing.
DR-H201-F3000
Standards and Certification Need Separate Decisions
| Reference | How it may relate | What must be verified |
|---|---|---|
| IEC 60068-2-1 / IEC 60068-2-2 | Cold and dry-heat environmental tests | Applicable procedure, severity, load and chamber performance. |
| IEC 60068-2-78 | Cab: steady-state damp heat | Temperature-RH point, duration, specimen state and acceptance criteria. |
| UN 38.3 | Lithium battery transport-test programme | Only the applicable procedure should be mapped; the chamber does not perform every T.1–T.8 test. |
| UL 1642 / UL 2580 or customer specification | Method-specific cell or EV battery safety evaluation | Exact edition, clause, fixtures, monitoring and separate abuse equipment. |
| ATEX / IECEx / IEC 60079 | Equipment for potentially explosive atmospheres | Do not claim certification without the exact certificate, model/configuration scope, equipment marking and issuing body. |
DR-H201-F3000
Recommended FAT for a Custom 3,000 L Chamber
Climate performance
Verify agreed temperature/RH points, empty and representative-load mapping, ramp definition, recovery and door-opening behaviour.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Check programme execution, alarms, access permissions, sensor records, export format, communication and power-failure recovery.
Safety cause and effect
Simulate every detector and fault input to verify alarms, isolation, exhaust, suppression command and safe-state sequence.
DR-H201-F3000
Information Required for an Accurate Quotation
| Topic | Send DERUI |
|---|---|
| Specimen | Dimensions, mass, quantity, chemistry, capacity, SOC, electrical energy and packaging. |
| Test profile | Temperature/RH programme, rates, dwell, cycles, tolerance and specimen operating mode. |
| Powered load | Maximum watts, charge/discharge current, duty cycle and cable/feedthrough requirements. |
| Failure scenario | Credible gas, smoke, flame, pressure, electrolyte, fragment and heat-release conditions. |
| Facility | Power, cooling water, drainage, exhaust route, fire system, ambient and installation access. |
| cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits | Mapping points, loaded performance, alarms, interlocks, data format and documentation. |
DR-H201-F3000
Compare the proposed equipment against the real test
Purchasing decision
A large battery chamber quotation should identify the boundary between the chamber supplier, external cycler supplier and facility contractor. Compare the same specimen energy, powered heat, climate profile and installation assumptions. Items such as ductwork, cooling services, lifting, cable supports and emergency interfaces should have an assigned owner so they do not become unresolved work after delivery.
Application planning
For a battery module or pack connected to an external cycler, show the loading method, support arrangement, power-cable route and measurement connections. Identify heat released inside the chamber and any external equipment that affects the room. The nominal 3,000 L volume does not establish door clearance, floor capacity or a safe loading path for a particular pack.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Request a coordinated layout, utility schedule, interface list and safety cause-and-effect matrix before design approval. Agree the representative-load climate test and the functional interlock demonstration separately. If ATEX, IECEx or other certification is required, request the exact certificate and configuration scope; do not infer certification or thermal-runaway containment from the product designation.
DR-H201-F3000
Choose the equipment for the intended application
Compare the equipment that matches your test scope: 2000L Climate and Temperature Test Chamber, غرفة اختبار مقاومة الانفجار ذات ثلاث طبقات لدرجة الحرارة العالية والمنخفضة.
Request a DR-H201-F3000 configuration review
Send the specimen drawing, quantity, mass, operating profile, powered heat, interfaces and destination utilities. Include the acceptance criteria and required test records so the proposed configuration can be reviewed against the actual test.
مراجعة DERUI company information و qualification documents. Confirm which supplied documents and configuration details apply to the equipment in your quotation.