الطابق 1، رقم 3، شارع شوغانغ، بلدة هونغمي، مدينة دونغقوان، مقاطعة قوانغدونغ، الصين

صانع غرف الاختبار البيئي لمدة 20 عامًاأكثر من 3000 تسليم للعملاء حول العالم   البريد الإلكتروني: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

غرفة اختبار درجة الحرارة والرطوبة الثابتة على المكتب

The DERUI desktop constant temperature and humidity test chamber is a compact laboratory climate chamber for small specimens and component-level environmental conditioning. The published DR-H201/22/40 baseline provides a 22 L workspace with programmable temperature-humidity control, curve display and USB record export. Confirm the final range, powered load and utilities in the approved technical proposal.

Published Model DR-H201/22/40
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 22 L · 300 × 300 × 250 mm
Published Temperature -40°C إلى +150°C
Published Humidity 30% to 95% RH
Controls & Records 7-inch touch controller, programme and curve display, USB export
Before Quotation Confirm specimen size, powered load, profile, data record and local utilities
آمن وموثوق
مصنوع بشكل جيد
ضمان الجودة
تخصيص
رسالةواتساب
رقم الخط الساخن 15580327593
  • تفاصيل المنتج
  • المعلمات الفنية
  • الأسئلة الشائعة
  • اتصل بنا

Compact Laboratory Climate Simulation

Desktop Constant Temperature and Humidity Test Chamber

Use a compact DERUI climate chamber for small specimens, component development and laboratory environmental conditioning. The published DR-H201/22/40 baseline combines programmable temperature and humidity control in a 22 L workspace. Final range, capacity and utilities follow the approved technical proposal.

Engineering basis: desktop footprint does not define loaded performance. State the specimen envelope, fixtures, powered heat, required profile and data records before selecting the configuration.
Published model baselineDR-H201/22/40
Published workspace22 L · 300 × 300 × 250 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits-40°C إلى +150°C
Published humidity range30% to 95% RH

Where a Desktop Climate Chamber Fits

The compact chamber supports component-level environmental conditioning where laboratory space is limited and specimen size allows airflow to remain clear. It is selected from the required exposure, not merely from a volume label.

Electronic assemblies

Condition PCBs, connectors, control modules, sensors and compact assemblies under defined temperature-humidity programmes.

Materials and research

Run controlled damp-heat exposure, comparative ageing and conditioning studies with documented specimen placement.

Small product development

Evaluate packaged components and small devices before moving to a larger floor-standing chamber for batch or fixture-heavy testing.

Published DR-H201/22/40 Configuration

عنصر Published value Procurement note
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 22 L; 300 × 300 × 250 mm Confirm usable volume after racks, fixtures and cable routing.
نطاق درجة الحرارة -40°C إلى +150°C Confirm the selected configuration, test condition and mapping method.
Temperature performance Fluctuation ±0.3°C; uniformity 2.5°C Confirm stabilization condition, sensor points and whether the item is powered.
Temperature change Heating 3.0°C/min; cooling 1.0°C/min Confirm definition, ambient condition and loaded performance.
أداء الرطوبة 30% to 95% RH; fluctuation ±3.0% RH Confirm the valid combined temperature-RH operating envelope.
Controls and records 7-inch touch panel, programme and curve display, USB export State record interval, file format and report requirements.
Port and observation Φ50 mm test hole; heated double-layer observation window Confirm port quantity, cable sealing and fixture layout.

How the Climatic Control System Supports a Test

Control air temperature

Heating and refrigeration establish the programmed chamber-air temperature and transition rate.

Regulate moisture

Humidification and dehumidification maintain relative humidity within the selected operating envelope.

Distribute and record

Air circulation and controller records support a documented exposure across the usable workspace.

Powered specimens: live heat can affect cooling response and humidity control. Provide maximum watts and duty cycle before the refrigeration configuration is confirmed.

Published Chamber and Control Features

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

The current page lists a SUS304 stainless-steel inner chamber, cold-rolled painted outer enclosure, glass-fibre insulation and silicone door seal.

Racks and access

The listed configuration includes two adjustable stainless sample racks and a Φ50 mm test port with thermal insulation accessories and sealing plug.

Controller functions

The published 7-inch touch controller supports temperature-humidity programming, curve display, alarm indication and USB data export.

DERUI Desktop Chamber Reference Image

DERUI desktop constant temperature and humidity test chamber for laboratory environmental testing

Current DERUI product image. Final controller, ports, shelving and utilities follow the approved configuration.

Loading and Operating Discipline

Maintain airflow clearance

Keep specimen supports and fixtures clear of air supply and return paths; nominal volume is not usable loaded space.

Seal cable entries

Close unused cable-port area to limit ambient air and moisture leakage that can disturb the exposure.

Confirm water requirements

Follow the approved manual for water quality, feed arrangement, drainage and humidifier maintenance.

Define dwell start

State whether exposure begins at controller setpoint or after specimen sensors reach stabilization.

Record the loaded state

Document mass, location, fixture, powered operation and interfaces for repeatable later cycles.

Verify the procedure

Confirm standard edition, profile, monitoring and acceptance criteria before treating a cycle as compliance evidence.

Map the Chamber to the Test Procedure

The test standard and product specification define the programme. The chamber must cover every required setpoint, transition, dwell and tolerance in its selected configuration.

Reference الاستخدام النموذجي Confirm before testing
IEC 60068-2-30 Cyclic damp heat Edition, cycle, transitions, condensation and recovery.
IEC 60068-2-78 Steady-state damp heat Temperature, RH, duration, stabilization and evaluation.
MIL-STD-810H Method 507.6 Tailored humidity exposure Procedure, climatic cycle, specimen operation and acceptance criteria.
JESD22-A101 / A100 Electronic-device moisture testing Applicable method, bias interfaces, safety and monitoring.

RFQ and FAT Checklist

Topic Information to provide or verify
Specimen Dimensions, mass, quantity, fixtures, material and powered heat.
Profile Temperature-RH points, transitions, dwell, cycles and tolerances.
Interfaces Ports, power, signals, thermocouples, network and data records.
المرافق Voltage, frequency, current, water quality, drainage and ambient limits.
FAT Sensor map, stabilization, deviation, uniformity, alarms and report format.
Documents Approved drawing, bill of materials, manuals, electrical diagram and agreed calibration scope.

الأسئلة المتكررة

What is the published baseline workspace?

The current parameter table lists DR-H201/22/40 with a 22 L workspace measuring 300 × 300 × 250 mm. Confirm other capacities on their approved drawings.

What temperature and humidity ranges are published?

The 22 L parameter table lists -40°C to +150°C and 30% to 95% RH. The final configuration and usable envelope must be confirmed in the quotation.

Can the chamber record a test profile?

The published 7-inch touch controller supports programme input, curve display and USB export. Confirm record interval, file format and evidence requirements before procurement.

Can I test powered electronics inside?

State heat dissipation, duty cycle, cables and safety requirements in advance. The permitted loaded performance must be agreed for the actual configuration.

Which standards can it support?

The page references GB 5170 and older IEC 60068 equivalents. Specify the exact current standard edition and programme; equipment capability alone does not claim compliance.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send specimen dimensions, mass, quantity, live heat load, profile, cable needs, site utilities, data requirements and target method.

Configure a Compact Climate Chamber from the Real Test

Send the specimen drawing, temperature-humidity programme, powered load, test standard and data requirements. DERUI can confirm workspace, environmental range, controller records and installation details in the technical proposal.

Request a Desktop Chamber Proposal

فيسبوكلينكدإنXريديتواتساب
الموديل
DR-H201/22/40
نظام
نظام التحكم في درجة الحرارة والرطوبة المتوازن (BTHC)
السعة
22 لتر
حمولة
20 كجم
الأبعاد الداخلية العرض×الارتفاع×العمق مم
300×300×250
الأبعاد الخارجية العرض×الارتفاع×العمق مم
440×740×780
درجة الحرارة

الأداء
نطاق درجة الحرارة
 -40 إلى +150 درجة مئوية
تقلب درجة الحرارة
±0.3 درجة مئوية
توحيد درجة الحرارة
2.5 درجة مئوية
معدل تغير درجة الحرارة
معدل التسخين: 3.0 درجة مئوية/دقيقة معدل التبريد: 1.0 درجة مئوية/دقيقة
وقت الوصول إلى درجة الحرارة القصوى
وقت التسخين: من -40 إلى +150 درجة مئوية خلال 60 دقيقة معدل التبريد: من +20 إلى -40 درجة مئوية خلال 50 دقيقة
الحمولة الحرارية المسموح بها
درجة حرارة منطقة الاختبار +20°C ، 300 واط
أداء الرطوبة
نطاق الرطوبة
 30~95%rh
تقلب الرطوبة
±3.0%rh
الحمولة الحرارية المسموح بها
ظروف منطقة الاختبار: +85℃ / 85%rh 300 واط
الهيكل
المادة الخارجية
لوحة إلكتروليتية متقدمة سميكة 1.5 مم + طلاء مضاد للتآكل
المادة الداخلية
الفولاذ المقاوم للصدأ SUS304 بسماكة 1.2 مم
نظام إمداد المياه (التكوين القياسي)
إمداد المياه التلقائي
خزان المياه (اختياري)
8 لتر
نظام التبريد
تبريد بالضغط الميكانيكي من مرحلة واحدة
ضاغط
ضاغط مغلق بالكامل
مبرد
R-404A [متوفر R-449A عند الطلب]
الطاقة
0.65 كيلو واط
آلية التمديد
صمام التمدد الإلكتروني
مستوى الضوضاء
60 ديسيبل
  1. س: ما هو حجرة اختبار درجة الحرارة والرطوبة الثابتة المكتبية؟
    A: هي جهاز اختبار بيئي مدمج يُستخدم لمحاكاة ظروف درجة الحرارة والرطوبة الدقيقة لاختبار المنتجات أو العينات الصغيرة.

  2. س: كيف يتحكم في درجة الحرارة والرطوبة؟
    A: يستخدم نظام تبريد للتبريد، وسخانات للتسخين، ونظام ترطيب/إزالة رطوبة للحفاظ على مستويات رطوبة محددة.

  3. س: ما هي تطبيقاته النموذجية؟
    A: يستخدم عادة لاختبار الإلكترونيات، والأدوية، والبطاريات، والمواد، والآثار الثقافية في مختبرات البحث وخطوط الإنتاج.

  4. س: ما هو نطاق درجة الحرارة القياسي؟
    A: عادة من -20°C إلى +150°C، مع بعض الطرازات التي تقدم -40°C إلى +180°C.

  5. س: ما هو نطاق الرطوبة الذي يمكن أن يحققه؟
    A: عمومًا من 20% إلى 98% RH، مع بعض الطرازات التي تدعم من 10% إلى 98% RH.

  6. س: ما مدى دقة التحكم في درجة الحرارة؟
    A: عادة ±0.5°C أو أفضل في الحالة المستقرة.

  7. س: ماذا عن دقة التحكم في الرطوبة؟
    A: عادة ±2.5% RH أو أفضل.

  8. س: ما هو مصدر الطاقة الذي يتطلبه؟
    A: تعمل معظم النماذج على تيار كهربائي AC 220 فولت / 50 هرتز أو 110 فولت / 60 هرتز القياسي.

  9. س: كم المساحة التي يحتاجها؟
    A: كجهاز مكتبي، عادةً يتطلب أقل من 1 متر مربع من مساحة الطاولة.

  10. س: ما خيارات الواجهة المتاحة؟
    A: تتميز معظم الوحدات الحديثة بشاشات تعمل باللمس وتدعم الاتصال عبر USB / RS485 / Ethernet.

  11. س: كم مرة يجب معايرته؟
    A: موصى به سنويًا أو كل 6 أشهر للتطبيقات الحرجة.

  12. س: ما الصيانة التي يتطلبها؟
    A: تنظيف الفلاتر بانتظام، فحص مستويات المبرد، وتنظيف حساسات الرطوبة.

  13. س: هل يمكنه برمجة دورات اختبار معقدة؟
    A: نعم، تدعم معظم النماذج برمجة متعددة القطاعات لدورات درجة حرارة / رطوبة معقدة.

  14. س: ما ميزات الأمان المضمنة؟
    A: تتضمن عادة حماية من ارتفاع درجة الحرارة، حماية من الاحتراق الجاف، وحماية تأخير الكمبروسر.

  15. س: كيف تختار النموذج المناسب؟
    A: خذ بعين الاعتبار حجم العينة، نطاق درجة الحرارة / الرطوبة المطلوب، احتياجات الدقة، والمساحة المتاحة على الطاولة.

واتسابواتساب
واتسابواتساب
واتساب
رسالةرسالة

اطلب عرض سعر