Этаж 1, д. 3, проспект Шуган, город Хунмэй, город Дунгуань, провинция Гуандун, Китай

Производитель климатических камер для испытаний окружающей среды более 20 летБолее 3000 заказов клиентов по всему миру           Электронная почта: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Rapid Temperature Change Test Chamber Fast-Rate Thermal Cycling ESS

The DERUI DR-H204 rapid temperature change test chamber supports fast-rate thermal cycling and environmental stress screening while the specimen remains stationary. The published 800 L configuration offers selectable low-temperature ranges and cooling rates from 5°C/min to 25°C/min. Confirm the rate definition, temperature span and loaded performance in the approved technical agreement.

Модель DR-H204
Workspace 800 L · 1000 × 800 × 1000 mm
Temperature Options -20 / -40 / -70°C to +150°C
Published Ramp Rates Heating 5°C/min; cooling 5 / 10 / 15 / 25°C/min
Источник питания Three-phase 380 V / 50 Hz
Before Quotation Confirm average/linear rate, span, specimen mass, powered heat, utilities and FAT method
Безопасно и надежно
качественно изготовлено
Гарантия качества
кастомизация
СообщениеWhatsApp
Номер горячей линии 15580327593
  • Детали продукта
  • Технические параметры
  • Часто задаваемые вопросы
  • Свяжитесь с нами
Fast-Rate Thermal Cycling · ESS

DR-H204 Rapid Temperature Change Test Chamber

Run accelerated heating and cooling cycles for environmental stress screening of electronics, automotive components, aerospace assemblies and other temperature-sensitive products. The published 800 L configuration provides selectable low-temperature options and rapid cooling rates up to 25°C/min.

Rate definition matters: state whether the required ramp is average or linear, the start and end temperatures, air or specimen measurement, and the full powered load. A single “°C/min” value is not enough to size or accept an ESS chamber.
Published modelDR-H204
Published workspace800 L · 1000 × 800 × 1000 mm
Temperature options-20 / -40 / -70°C to +150°C
Published ratesHeat 5°C/min · Cool 5/10/15/25°C/min

Where Fast-Rate Thermal Cycling Fits

This chamber keeps the specimen stationary while the conditioned air follows a programmed ramp and dwell profile. It is designed for screening and thermal cycling—not the near-instant transfer exposure produced by a two- or three-zone thermal shock chamber.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Expose boards, modules, connectors and power electronics to repeated temperature transitions that help reveal assembly and material weaknesses.

Automotive and aerospace

Cycle controllers, sensors, lighting, avionics and compact assemblies using the applicable product or customer procedure.

Battery and energy systems

Evaluate non-abuse thermal-cycle performance only after specimen heat, electrical interfaces and the required safety scope are defined.

Published DR-H204 800L Configuration

Пункт Published value Procurement note
Internal workspace 1000 × 800 × 1000 mm; 800 L Confirm W × D × H and usable space after fixtures and airflow clearance.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 1580 × 1700 × 2260 mm Confirm installation, service and door-access clearances on the drawing.
Temperature range options -20 / -40 / -70°C to +150°C Select one refrigeration configuration for the required profile.
Колебания температуры ±1°C Confirm setpoint, stabilized condition, sensor location and load.
Темп нагрева 5°C/min Confirm average or linear definition, temperature span and load state.
Cooling rate options 5 / 10 / 15 / 25°C/min Confirm selected rate, temperature span, ambient, cooling utility and load.
Sample trays and port Three SUS304 trays; Φ50 mm test hole Confirm tray loading and whether port size/quantity suits the interfaces.
Электропитание Three-phase 380 V / 50 Hz Rated current and power depend on the final refrigeration configuration.

Define the Ramp Before the Chamber Is Sized

Fix the endpoints

State the exact start and finish temperatures. A rate quoted across a narrow central span cannot be assumed across the full chamber range.

Choose the measurement basis

Specify chamber-air control, monitoring sensor positions and whether specimen temperature must follow the same slope.

Add the real load

Include specimen mass, fixture thermal mass, powered watts, duty cycle and cable heat leakage in the cooling calculation.

FAT basis: record the programmed and measured curves, rate calculation window, sensor map, stabilization rule and loaded or empty condition in the technical agreement.

Rapid Thermal Cycling Chamber Reference Image

DERUI DR-H204 rapid temperature change test chamber for fast-rate ESS thermal cycling

Current DERUI rapid temperature change chamber reference image. Final door, controller, ports and refrigeration arrangement follow the approved configuration.

Engineering Factors That Control Loaded Performance

Refrigeration capacity

The selected low-temperature end, cooling rate, test load and facility cooling conditions determine the required refrigeration system.

Heating and control

Heater capacity and control tuning must reproduce the programmed upward transition without unacceptable overshoot.

Airflow and fixture design

Specimen spacing and low-mass, open fixtures help conditioned air reach all surfaces and reduce local temperature lag.

Powered heat

Live electronics oppose the cooling system. Provide maximum continuous and transient watts rather than a nominal device rating.

Ports and interfaces

Define power, signals, thermocouples and communication cables so feedthroughs can be sized and sealed correctly.

Facility utilities

Confirm electrical supply, heat rejection, cooling-water conditions if applicable, drainage, ambient limits and service access.

Rapid Change Chamber vs. Thermal Shock Chamber

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Rapid temperature change chamber cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Remains stationary in one workspace. Typically transfers between separate hot and cold zones.
Exposure definition Controlled air ramp in °C/min with programmed dwells. Transfer time and recovery after zone change are central.
Powered monitoring Well suited when interfaces remain connected during cycling. Requires cable routing compatible with the transfer system.
Use when The procedure specifies a controlled temperature-change rate. The procedure requires abrupt zone transfer or thermal shock recovery.

Map the Chamber to the Test Method

The standard defines the exposure; the equipment does not create compliance by itself. Confirm the current edition, severity, test type and acceptance criteria.

Reference Typical relationship Confirm before claiming suitability
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Change of temperature methods Test designation, temperatures, transition, dwell and specimen operation.
MIL-STD-810H Tailored high/low temperature exposure Applicable method/procedure, rates, stabilization and functional checks.
JEDEC device methods Electronic component temperature cycling Exact JESD method, air profile, load, monitoring and lot acceptance.
Customer ESS profile Production screening Fault-detection goal, cycle count, test limits and data retention.

RFQ and FAT Checklist

Topic Information to provide or verify
Profile Start/end temperatures, rate definition, dwells, cycles and tolerances.
Specimen Envelope, mass, quantity, material, fixtures and powered heat.
Measurement Air/specimen sensors, sample rate, rate calculation and report format.
Interfaces Power, signals, thermocouples, network, test ports and safety interlocks.
Коммунальные услуги Voltage, phase, current, cooling water if required, ambient and heat rejection.
FAT Empty/loaded condition, sensor map, ramps, dwells, alarms and acceptance limits.

Часто задаваемые вопросы

What ramp rates are published for this DR-H204 page?

The current technical table lists 5°C/min heating and 5, 10, 15 or 25°C/min cooling. Confirm the selected rate, temperature span and whether it is average or linear in the quotation.

Does the published rate apply under full powered load?

The visible table does not establish one universal loaded guarantee. Provide fixture mass and maximum powered heat so loaded performance can be calculated and included in FAT criteria.

Is this the same as a thermal shock chamber?

No. A rapid change chamber controls a programmed air-temperature ramp while the specimen remains stationary. A thermal shock chamber typically transfers the specimen between separate zones.

Is humidity standard on the 800 L configuration?

The page discusses optional humidity, but the published 800 L technical table does not establish a confirmed humidity envelope for every rapid-rate configuration. Treat it as an option requiring a separate operating chart.

What power supply is published?

The current 800 L technical table states three-phase 380 V / 50 Hz. Final current and rated power depend on the selected temperature and ramp-rate configuration.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send the full profile, rate definition, specimen drawing and mass, fixture, powered heat, interfaces, facility utilities, standards and FAT requirements.

Configure the DR-H204 from the Loaded ESS Profile

Send the complete temperature cycle and specimen data. DERUI can confirm the low-temperature option, cooling rate, refrigeration capacity, interfaces, utilities and acceptance plan before quotation.

Request a Rapid ESS Chamber Review

FacebookLinkedInXRedditWhatsApp

Пункт

Технические характеристики

Внутренние размеры (Ш*Г*В)

1000*800*1000мм

Внешние размеры (Ш*Г*В)

1580*1700*2260мм

Рабочая емкость

800 литров (может быть настроена)

Материал внутренней камеры

нержавеющая сталь SUS#304, зеркальная полировка

Материал внешней камеры

нержавеющая сталь с окраской распылением

Диапазон температур

-20/-40/-70℃~+150℃

Колебания температуры

±1℃

Темп подачи нагрева

5℃/мин、

Скорость охлаждения

5℃/мин、10℃/мин、15℃/мин、25℃/мин

Лоток для образцов

нержавеющая сталь SUS#304, 3 шт.

Испытательное отверстие

диаметр 50 мм, для прокладки кабеля

Мощность

трехфазное, 380 В/50 Гц

Защитное устройство безопасности

утечка

перегрев

перегрузка и перенапряжение компрессора

короткое замыкание нагревателя

Какие скорости нагрева предлагает камера быстрого изменения температуры Derui для ESS?

Наши камеры обеспечивают быстрые изменения температуры до 15°C в минуту, что идеально подходит для испытаний на стрессовую нагрузку окружающей среды (ESS). Такой быстрый темп нагрева помогает выявлять дефекты на ранних стадиях и ускоряет процесс тестирования.

Совместимы ли ваши камеры с испытаниями на влажность?

Да, многие наши камеры с быстрым термическим циклированием включают точное управление влажностью, что позволяет проводить температурное циклирование с влажностью для точного моделирования реальных условий.

Каковы типичные сроки поставки?

Стандартные модели обычно отправляются в течение 4-6 недель. Индивидуальные конфигурации могут занять немного больше времени — обычно около 5-8 недель, в зависимости от ваших требований.

Какие гарантии и услуги поддержки доступны?

Мы предоставляем гарантию на наши камеры сроком 12 месяцев, покрывающую запчасти и работу. Также мы предлагаем постоянную техническую поддержку и услуги по обслуживанию, чтобы ваше оборудование работало без сбоев.

 

Что такое камера для испытаний с быстрым изменением температуры?
Камера для испытаний с быстрым изменением температуры — это оборудование для экологических испытаний, которое быстро переключается между экстремальными температурами для оценки устойчивости продукции к тепловым нагрузкам. Она необходима для выявления потенциальных отказов в электронике, автомобильных компонентах и аэрокосмической технике.

Какие скорости нагрева могут достигать ваши камеры?
Наши камеры обеспечивают быстрые изменения температуры до 15°C в минуту, а некоторые индивидуальные конфигурации достигают еще более высоких скоростей. Такое ускоренное тестирование помогает быстрее выявлять дефекты продукции по сравнению с обычными камерами.

В каких отраслях используют камеры с быстрым температурным циклированием?
Ключевые отрасли включают автомобильную электронику, аэрокосмические компоненты, производство полупроводников, тестирование аккумуляторов, медицинские приборы и телекоммуникационное оборудование — везде, где важна надежность продукции при тепловых нагрузках.

 Как ваша камера обеспечивает равномерность температуры?
Мы используем передовые системы воздушного потока с точно сконструированными каналами и высокопроизводительными вентиляторами для поддержания равномерности температуры в пределах ±1,5°C по всему объему камеры, обеспечивая стабильные условия тестирования.

Какие стандарты соответствуют вашим камерам?
Наши камеры соответствуют основным международным стандартам, включая MIL-STD-810 для экологических испытаний, стандарты JEDEC для тестирования полупроводников, IEC 60068-2-14 для испытаний на изменение температуры и ISO 17025 для лабораторной компетентности.

Могу ли я проводить одновременно испытания на температуру и влажность в одной камере?
Да, мы предлагаем интегрированные системы контроля влажности с диапазоном от 10% до 95% RH, что позволяет проводить комбинированное температурное и влажностное циклирование в одной системе для комплексных экологических испытаний.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
СообщениеСообщение

Запросить коммерческое предложение