Le DERUI DR-H203-50 energy-saving temperature shock test chamber combines rapid hot–cold exposure with capacity matching and insulated zone management. Energy use should be compared under the same cycle, specimen load and facility conditions.

Modèle DR-H203-50
Type de test Air-to-air temperature shock
Published Ranges Hot +60°C to +150°C; cold 0°C to -40°C or -55°C
Efficiency Metric Measured kWh under a defined cycle and specimen load
Before Quotation Confirm architecture, load, transfer, recovery, utilities and comparison baseline
Sûr et fiable
bien fabriqué
Assurance qualité
personnalisation
MessageWhatsApp
Numéro de hotline 15580327593
  • Détails du produit
  • Paramètres techniques
  • FAQ
  • Contactez-nous
Energy-Efficient Air-to-Air Thermal Shock

DR-H203-50 Energy-Saving Temperature Shock Test Chamber

Combine rapid hot–cold exposure with capacity matching, insulated zone management and measurable energy reporting. Select the chamber around the required transfer, loaded recovery, specimen demand and cycle profile—then compare energy consumption under the same conditions.

ModèleDR-H203-50
Type de testAir-to-air thermal shock
Efficiency metricMeasured kWh per defined cycle
Primary decisionPerformance before savings

What Energy-Efficient Thermal Shock Must Deliver

Thermal shock can reveal failures caused by unequal expansion and contraction, including solder-joint cracking, delamination, seal leakage, coating separation and intermittent electrical faults. Lower energy use is useful only when the required exposure remains valid.

Maintain the required shock profile

Hot/cold conditions, transfer, recovery, dwell and cycle count must remain within the approved procedure.

Match capacity to the specimen

Workspace, specimen mass, fixtures and powered heat determine stored thermal capacity and recovery demand.

Reduce uncontrolled zone losses

Insulation, seals and controlled transfer openings reduce heat exchange between stored hot and cold environments.

Measure, do not assume

Compare total kWh using the same cycle, load, ambient condition, cooling method and measurement boundary.

No unsupported percentage: an “energy-saving” claim needs a named baseline and repeatable measurement conditions.

Published DR-H203-50 Baseline

Article Published value Project confirmation
Modèle DR-H203-50 Confirm usable workspace and specimen envelope
Hot-zone range +60°C to +150°C Confirm setpoint, dwell and tolerance
Cold-zone options 0°C to -40°C or 0°C to -55°C Select the project configuration
Heat-storage preparation Room temperature to +180°C within 35 min Zone preparation; not specimen response time
Cold-storage preparation Room temperature to -55°C within 60 min Confirm ambient and load condition
Conversion time 2–10 s Define basket transfer or airflow switching architecture
Recovery/stabilization 5 min Confirm sensor point, tolerance and representative load
Supply AC380V, 50/60Hz, three-phase Confirm site current and cooling utilities
Contrôleur 7-inch or 10-inch touchscreen Confirm programmes, communications and data functions

Where Lower Energy Consumption Can Come From

Capacity control

Heating and refrigeration stages can be matched to current demand instead of operating every stage continuously at maximum output. The exact control implementation is configuration-dependent.

Zone isolation

Effective insulation, door sealing and controlled transfer openings preserve stored hot and cold conditions between exposures.

Cycle-aware operation

Controller logic can reduce unnecessary conditioning during idle periods while preparing zones before the next exposure.

Correct sizing

An oversized system conditions more air and structure than needed. Use the specimen envelope, mass and heat capacity to select workspace and thermal capacity.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Exigence What must be defined
Architecture Two-zone specimen transfer or three-zone air-diverter arrangement and whether the specimen moves
Transfer and recovery Maximum conversion time, recovery tolerance, measurement point and empty/loaded condition
Dwell Whether dwell begins at transfer, chamber-air recovery or specimen stabilization
Charge Dimensions, mass, quantity, fixture, heat capacity, powered watts and cable interfaces
Energy boundary Preconditioning, active cycles, standby, facility cooling and the full measurement period
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Sensor positions, records, alarms, data format and FAT criteria

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Use the same cycle

Keep hot/cold setpoints, dwell basis, transfer, recovery requirement and number of cycles identical.

Use the same load

Specimen mass, material, fixture, initial temperature and operating heat must be comparable.

Control facility conditions

Record room temperature, supply voltage and cooling-water condition where applicable.

Report useful metrics

Compare total kWh, kWh per completed cycle, peak demand, recovery time and any failure to remain within tolerance.

Start with the Exact Test Procedure

IEC 60068-2-14:2023 addresses change-of-temperature tests. Semiconductor and microelectronic programmes may refer to other methods. Confirm the exact standard, edition, procedure, severities and acceptance criteria rather than claiming blanket compliance from the chamber name.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits a conventional single-zone chamber may produce a slower air ramp and a different stress mechanism. Transfer time alone also does not prove loaded specimen recovery.

Information Required for Configuration

Specimen

Envelope, quantity, mass, fixture, material, heat capacity, powered watts and cable connections.

Shock profile

Hot/cold temperatures, dwell, conversion, recovery, cycles and specimen measurements.

Facility

Voltage, available current, ambient conditions, cooling method, water, drainage and heat rejection.

Efficiency objective

Operating hours, comparison baseline and whether the target is lower kWh, peak demand, cooling-water use or total operating cost.

Foire Aux Questions

What makes this an energy-saving thermal shock chamber?

The design objective is to reduce avoidable heating, cooling and zone losses while maintaining the specified shock cycle. The actual result must be measured against a defined baseline.

Is rated power the same as energy consumption?

No. Rated power is a capacity or maximum-demand value. Energy consumption depends on power over time, controller duty, load, setpoints and facility conditions.

How should savings be verified?

Measure total kWh over the same preconditioning, active-cycle and standby boundary using the same specimen and exposure conditions.

Does faster conversion guarantee a valid test?

No. Recovery, dwell, uniformity and the specimen response criteria must also satisfy the selected procedure.

Can a standard temperature chamber replace it?

Only if the governing method permits the achieved transition. A single workspace usually creates a different thermal rate than stored hot and cold zones.

What is required for a quotation?

Send the method, specimen data, cycle, transfer and recovery requirements, powered heat, utilities, operating schedule and energy comparison target.

Specify Performance and Energy Use Together

Send DERUI the specimen load, thermal shock method, hot/cold profile, transfer and recovery limits, facility conditions and operating schedule. The proposal can then define the chamber architecture and the energy measurement basis.

Request a Configuration Review

FacebookLinkedInXRedditWhatsApp
Modèle DR-H203-50
Plage de choc thermique (Haute température : +60℃~+150℃ ; Basse température : 0℃~-40℃ ; 0℃~-55℃)
Temps de chauffage (zone de stockage de chaleur) RT~180℃≤35min
Temps de refroidissement (zone de stockage de froid) RT~-55℃≤60min
Temps de récupération et de stabilisation de la température 5min
Temps de conversion de la température 2-10S
Matériaux de la boîte intérieure et extérieure Boîte extérieure : plaque d'acier laminé à froid traitée anticorrosion émaillée ; boîte intérieure : plaque en acier inoxydable SUS304#
Matériau d'isolation Matériau d'isolation en mousse de polyuréthane PU haute résistance résistante au feu + fibre de verre ultra-fine
Système Système de contrôle de la température P.I.D+SSR+micro-ordinateur équilibré
Système de refroidissement Compresseur semi-hermétique à double étage (refroidi à l'eau) / compresseur entièrement hermétique à double étage (refroidi à l'air)
Dispositif de protection de sécurité Interrupteur sans fusible, interrupteur de protection haute et basse pression du compresseur, protection contre le surintensité, protection contre la surchauffe, interrupteur de protection haute pression du réfrigérant, système d'alarme de défaillance
Accessoires Fenêtre d'observation (type optionnel spécial), deux étagères réglables en hauteur, trou de test d'alimentation électrique, roulettes, support de nivellement
Alimentation électrique AC380V50HZ/60HZ 3∮
Contrôleur Écran tactile LCD de 7 pouces/10 pouces, affichage en chinois/anglais
Compresseur Français “Taylor”, Allemand “Bitzer”/“Bock”
Plus de paramètres Veuillez nous contacter !

Question 1 : Êtes-vous un fabricant ? Pouvez-vous personnaliser l'équipement selon nos exigences spécifiques ?

Oui, nous sommes un fabricant chinois de chambres d'essai environnemental avec 20 ans d'expérience dans l'industrie. Nous pouvons personnaliser l'équipement selon vos exigences exactes. Notre équipe de R&D interne propose des services OEM, ODM et OBM pour garantir que votre solution répond à vos besoins commerciaux.

Question 2 : Combien de temps faut-il pour obtenir un devis ?
Réponse 2 : Nous fournissons généralement des devis dans les 24 heures après réception de votre demande. Si vous avez besoin d'une réponse plus rapide, n'hésitez pas à nous appeler ou à nous envoyer un e-mail pour nous informer de vos besoins urgents, et nous donnerons la priorité au traitement de votre demande.

Question 3 : Quel est le délai de livraison habituel pour vos produits ?
Réponse 3 : Le délai de livraison standard pour la plupart de nos produits est de 30 jours. Pour des commandes plus importantes ou des équipements personnalisés, le délai peut être prolongé de 30 à 50 jours, en fonction de la quantité et de la personnalisation requise.

Question 4 : Quels modes de paiement acceptez-vous ?
Réponse 4 : Nous proposons diverses options de paiement sécurisées, notamment PayPal, T/T, Visa, Western Union, etc., pour vous permettre de choisir la méthode la plus pratique pour votre transaction.

Question 5 : Quels modes de livraison sont disponibles ?
Réponse 5 : Nous expédions dans le monde entier via plusieurs méthodes : fret maritime, fret aérien ou express (DHL, FedEx, etc.). Nous recommandons toujours l'option de livraison la plus économique et efficace en fonction de votre localisation et de vos préférences.

Question 6 : Comment sont calculés les coûts d'expédition et les taxes ?
Réponse 6 : Les coûts d'expédition dépendent du mode de transport, de la destination et du poids de l'équipement. Nous fournissons toujours des informations claires sur les frais de livraison à l'avance. Les taxes sont déterminées par la réglementation locale en France et sont gérées par le pays de réception.

Question 7 : Cela inclut-il l'installation et la formation ? Est-il nécessaire que des techniciens soient sur place ?
Réponse 7 : Aucun technicien n'est nécessaire sur place. Toutes nos machines sont conçues pour être faciles à installer et prêtes à l'emploi. Nous fournissons des manuels d'utilisation détaillés et une formation à distance gratuite par nos ingénieurs experts. Si vous avez besoin d'aide, nous pouvons également vous guider à travers des vidéos d'installation et un support à distance en temps réel.

Question 8 : Quel type de service après-vente puis-je attendre ?
Réponse 8 : Nous offrons un support à vie pour tous nos produits. Notre équipe d'ingénieurs professionnels répondra à toute question dans les 12 heures. La plupart des problèmes peuvent être diagnostiqués et résolus à distance. S'il s'agit d'un problème matériel, nous enverrons des pièces de rechange gratuitement via DHL et fournirons des instructions d'installation détaillées.

 

Question 9 : Offrez-vous des services de garantie pour votre équipement ?
Réponse 9 : Oui, tout l'équipement bénéficie d'une garantie complète d'un an. Nous proposons également des services de maintenance et de support après la période de garantie pour assurer le bon fonctionnement de votre équipement pendant de nombreuses années.

Question 10 : Puis-je visiter votre usine ?
Réponse 10 : Oui, vous êtes le bienvenu pour visiter notre usine à Dongguan, en Chine. Voir notre opération en personne et discuter de votre projet face à face nous aidera à mieux comprendre vos besoins. Nous pouvons organiser la visite selon votre convenance.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MessageMessage

Demandez un devis