Calle Shugang 1, No. 3, Town de Hongmei, Ciudad de Dongguan, Provincia de Guangdong, China

Fabricante de cámaras de prueba ambiental con 20 años de experienciaMás de 3000 entregas a clientes en todo el mundo           Correo electrónico: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Cámara de prueba de temperatura de batería

Configurable battery temperature test chamber for lithium cells, modules and battery packs. It supports controlled hot/cold performance testing and optional external charge/discharge interfaces, with the safety package selected according to battery energy and test risk.

Rango de temperatura Published −60°C to +150°C platform
Battery level Cell, module and battery pack
Electrical testing Optional external cycler and monitoring feedthroughs
Seguridad Risk-based relief, detection, exhaust and suppression options
Segura y confiable
bien hecha
Garantía de calidad
personalización
MensajeWhatsApp
Número de línea directa 15580327593
  • Detalles del producto
  • Parámetros técnicos
  • Preguntas frecuentes
  • Contáctanos
Battery environmental conditioning

Controlled Temperature Testing for Battery Cells, Modules and Packs

A battery temperature test chamber creates controlled hot, cold or programmed cycling conditions around the specimen. It can support development, verification and production-quality work when the chamber is matched to the complete battery load, operating state and governing test procedure.

Temperature range alone is not enough for selection. Battery mass, heat capacity, powered heat output, fixture layout and airflow restriction determine whether the loaded specimen can follow the required profile. Safety provisions must also match the cell chemistry, state of charge, energy and credible failure modes.

Direct answer: send the complete temperature graph and specimen information before selecting chamber volume or cooling capacity. If the method involves crushing, penetration, overcharge, external short circuit, fire exposure or thermal-runaway propagation, review the dedicated abuse-test equipment and facility separately.

Current page specification

Performance Data for Preliminary Configuration

The existing page does not identify a model or standard chamber volume. Treat these values as a preliminary performance description and reconfirm them against the selected size, cooling system and ordered safety package.

Artículo Current published value Quotation requirement
Rango de temperatura −40°C to +100°C; −70°C stated as customizable Confirm required extremes, working range and selected refrigeration system.
Heating rate, no load 1°C/min; 5–25°C/min stated as customizable Define start/end points, air or specimen basis, load and tolerance.
Cooling rate, no load 1°C/min; 5–25°C/min stated as customizable Define start/end points, ambient condition, load and cooling method.
Uniformidad de temperatura ≤±1°C, no load Confirm workspace, sensor layout, setpoints and verification method.
Fluctuación de temperatura ≤±0.5°C Confirm the measurement convention and operating range.
Controller and sensor Multi-segment fuzzy PID; 7-inch touch screen; PT100 Class A Confirm programs, channels, alarms, permissions and required records.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits TCP/RS485; CAN stated as customizable Define protocol, data fields and connection to external cycler or DAQ.
Test port One Ø100 mm port Confirm cable quantity, connector size, sealing and thermal leakage.
Construcción SUS304 interior; coated cold-rolled-steel exterior Confirm chamber size, shelves, floor load and battery fixtures.
Potencia 380 V, 50 Hz Final voltage, phase, current and breaker depend on configuration.

Data correction required: the old page lists an observation window as “300 × 450 cm.” This is not credible for a chamber window and must be verified from the drawing before publication. The old generic claim of −60°C to +150°C also conflicts with the parameter table and has therefore not been retained.

Method before chamber

Convert the Battery Test into a Complete Loaded Profile

The applicable battery, vehicle, transport or customer document determines the exposure. Do not copy a temperature sequence from another product without confirming specimen type, operating condition and edition.

Temperature storage

Unpowered specimens may be held at defined hot or cold conditions, followed by recovery and inspection.

  • Starting condition
  • Setpoint and tolerance
  • Stabilization criterion
  • Dwell and recovery

Operating-temperature test

Cells, modules or packs may operate, charge or discharge while temperatures change. External cyclers and monitoring interfaces become part of the setup.

  • Current and voltage limits
  • Heat output
  • Cable routing
  • Fault and stop conditions

Ciclado de temperatura

Repeated high-low exposure requires a complete graph defining ramps, dwells, cycle count and when timing begins.

  • Air versus specimen rate
  • Loaded recovery
  • Sensor locations
  • Data and deviations
Do not confuse no-load air performance with battery temperature response. A heavy or energized pack may change temperature much more slowly and may require greater refrigeration capacity than an empty-chamber catalogue value suggests.
Risk-based configuration

Match Safety Functions to the Battery Hazard

The existing page mixes standard protections with optional fire and pressure controls. The final design must come from a documented risk assessment, not a generic feature list.

Electrical and temperature protection

Define independent over-temperature limits, heater and refrigeration protection, overcurrent, overload, grounding and emergency isolation.

Event detection

Specify temperature, smoke, gas, pressure or video monitoring only where required, including alarm and shutdown logic.

Pressure and exhaust

Review credible gas release, relief path, ducting, treatment, room ventilation and safe discharge location.

Fire response

Define whether suppression, flooding, water, inert gas or another strategy is permitted for the specimen and facility.

Operator separation

Consider reinforced construction, door restraint, remote observation, access interlock and an exclusion zone according to test energy.

Importante: pressure relief, fire suppression, gas detection and reinforced construction must not be presented as standard until the selected configuration confirms them. The chamber does not replace the laboratory emergency plan or local authority requirements.

Information before quotation

Nine Inputs for Battery Chamber Selection

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Standard, edition, clause, customer document and deviations.

Specimen envelope

Dimensions, mass, quantity, orientation, spacing and fixtures.

Battery condition

Chemistry, capacity, state of charge and prior conditioning.

Complete profile

Start, extremes, ramp, stabilization, dwell, recovery and cycles.

Powered heat load

Charge/discharge current, changing heat output and external cycler.

Measurement basis

Air and specimen sensors, channel count, rate definition and records.

Safety package

Credible failures, detection, relief, exhaust, isolation and response.

Laboratory utilities

Power, cooling, drainage, ventilation, access and floor loading.

Acceptance evidence

Drawings, options, calibration, loaded demonstration and documents.

Loaded acceptance test: agree on specimen simulator or actual load, sensor positions, temperature points, ramp definition, tolerances, dwell, safety logic and exported records before manufacture is completed.

Buyer questions

Battery Temperature Test Chamber FAQs

What temperature range should be selected?

Select from the required test extremes plus usable control margin, not from the widest catalogue range. Confirm the loaded profile, ambient conditions and selected refrigeration system.

Is 1°C/min the battery temperature-change rate?

No. The current page states a no-load chamber performance. Battery response depends on mass, heat capacity, airflow, fixture and powered heat output. Define the required measurement point and load.

Does this chamber control humidity?

The published parameter table does not confirm a humidity system. If temperature-humidity testing is required, specify the complete operating envelope, water system and dew/frost constraints as a different configuration.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Yes only when the project includes suitable feedthroughs, external cycler interfaces, cable protection, electrical monitoring and agreed fault logic. Send current, voltage and heat-output data.

Are fire suppression and gas detection included?

They are not confirmed as standard by the parameter table. Select them through the project risk assessment and list the ordered safety hardware in the technical agreement.

What information is needed for quotation?

Provide the method, complete profile, battery drawing, mass, chemistry, state of charge, powered condition, heat output, fixtures, monitoring, hazards, utilities and acceptance requirements.

Configure the Chamber Around Your Battery Load

Send the temperature graph, battery drawing, state of charge, powered heat output, safety assessment and laboratory utilities.

Request a Battery Chamber Review →

FacebookLinkedInXRedditWhatsApp
​​Ítem​​ ​​Parámetro​​
Rango de temperatura -40℃~100℃ (personalizable a -70℃)
Velocidad de Calentamiento (Sin carga) (+20~150℃) 1℃/min (personalizable de 5~25℃)
Velocidad de Enfriamiento (Sin carga) (+20~-40℃) 1℃/min (personalizable de 5~25℃)
Uniformidad de temperatura ≤±1℃ (Sin carga)
Fluctuación de temperatura ≤±0.5℃
Precisión de Temperatura ≤±0.1℃
Tamaño de Ventana 300 * 450 cm
Refrigerante R404A
Orificio de Prueba φ100mm×1
Calentador Calentador Eléctrico
Condensador Refrigerado por Aire Intercambiador de Calor de Aletas
Condensador Refrigerado por Agua Intercambiador de Calor de Placa/Tubo y Casco
Circulación de Aire Motor de eje extendido, ventilador centrífugo de acero inoxidable
Método de enfriamiento Enfriamiento de un solo etapa
Compresor Compresor de frecuencia variable de marca
Método de control Algoritmo Fuzzy PID de múltiples segmentos
Interfaz de Comunicación TCP/RS485 (CAN personalizable)
Panel de operación Pantalla táctil a color de 7 pulgadas, Visualización de curva de temperatura, Exportación de datos a Excel
Sensor Resistencia de platino PT100 de Clase A
Dispositivo de protección Protección de doble temperatura del calentador, Protección del sistema de refrigeración, Protección contra sobrecorriente y sobrecarga, etc.
Fuente de alimentación 380V 50HZ
Material de aislamiento Algodón de fibra de vidrio y poliuretano
Material de la caja interior Acero inoxidable SUS304
Material de la caja exterior Placa de acero laminado en frío + Recubrimiento en spray
Normas de cumplimiento GB/T 2423.1; GB/T 2423.2; GB/T 2423.3; GB/T 2423.4; GB/T 5170.2; GB/T 5170.5; GB/T 11158; GB/T 10589; GB/T 10592; GB/T 10586; IEC 60068-3-5

1. ¿Qué es una cámara de prueba de temperatura de batería?
Una cámara de prueba de temperatura de batería es un dispositivo especializado utilizado para probar el rendimiento de la batería bajo condiciones controladas de temperatura.

2, ¿Cómo funciona la cámara de prueba de temperatura de la batería?
La cámara simula diversos entornos de temperatura para analizar la estabilidad y el rendimiento de las baterías probadas en su interior.

3, ¿Por qué es importante la prueba de temperatura para las baterías?
La prueba de temperatura es fundamental para garantizar la seguridad, fiabilidad y longevidad de los sistemas de baterías en diversas aplicaciones.

4, ¿Qué tipos de baterías se pueden probar en esta cámara?
Esta cámara puede acomodar varios tipos de baterías, incluyendo de ion de litio, de hidruro de níquel-metal y de plomo-ácido.

5, ¿Existen características de seguridad en la cámara de prueba de temperatura de la batería?
Sí, las características de seguridad incluyen apagado automático, protección contra sobretemperatura y construcción reforzada para protección.

6, ¿Qué tan rápido ajusta la temperatura la cámara?
La cámara está diseñada para enfriar y calentar rápidamente, minimizando el tiempo de inactividad durante las pruebas de batería.

7, ¿Se pueden registrar y exportar los datos de prueba?
¡Por supuesto! La cámara cuenta con funciones avanzadas de registro de datos que permiten una fácil grabación y exportación de datos.

8, ¿Es fácil de usar la cámara?
Sí, la cámara cuenta con una interfaz intuitiva que facilita a los usuarios navegar y controlar las pruebas.

9, ¿Cómo se compara esta cámara con otras en el mercado?
Nuestra cámara destaca por su combinación de precisión, seguridad y funciones avanzadas para pruebas exhaustivas.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MensajeMensaje

Solicitar una Cotización