ห้องทดสอบอุณหภูมิคงที่และความชื้นแบบตั้งโต๊ะ

The DERUI desktop constant temperature and humidity test chamber is a compact laboratory climate chamber for small specimens and component-level environmental conditioning. The published DR-H201/22/40 baseline provides a 22 L workspace with programmable temperature-humidity control, curve display and USB record export. Confirm the final range, powered load and utilities in the approved technical proposal.

Published Model DR-H201/22/40
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 22 L · 300 × 300 × 250 mm
Published Temperature -40°C ถึง +150°C
Published Humidity 30% to 95% RH
Controls & Records 7-inch touch controller, programme and curve display, USB export
Before Quotation Confirm specimen size, powered load, profile, data record and local utilities
ปลอดภัยและเชื่อถือได้
คุณภาพดี
การรับประกันคุณภาพ
การปรับแต่ง
ข้อความWhatsApp
หมายเลขสายด่วน 15580327593
  • รายละเอียดสินค้า
  • พารามิเตอร์ทางเทคนิค
  • คำถามที่พบบ่อย
  • ติดต่อเรา

Compact Laboratory Climate Simulation

Desktop Constant Temperature and Humidity Test Chamber

Use a compact DERUI climate chamber for small specimens, component development and laboratory environmental conditioning. The published DR-H201/22/40 baseline combines programmable temperature and humidity control in a 22 L workspace. Final range, capacity and utilities follow the approved technical proposal.

Engineering basis: desktop footprint does not define loaded performance. State the specimen envelope, fixtures, powered heat, required profile and data records before selecting the configuration.
Published model baselineDR-H201/22/40
Published workspace22 L · 300 × 300 × 250 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits-40°C ถึง +150°C
Published humidity range30% to 95% RH

Where a Desktop Climate Chamber Fits

The compact chamber supports component-level environmental conditioning where laboratory space is limited and specimen size allows airflow to remain clear. It is selected from the required exposure, not merely from a volume label.

Electronic assemblies

Condition PCBs, connectors, control modules, sensors and compact assemblies under defined temperature-humidity programmes.

Materials and research

Run controlled damp-heat exposure, comparative ageing and conditioning studies with documented specimen placement.

Small product development

Evaluate packaged components and small devices before moving to a larger floor-standing chamber for batch or fixture-heavy testing.

Published DR-H201/22/40 Configuration

รายการ Published value Procurement note
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 22 L; 300 × 300 × 250 mm Confirm usable volume after racks, fixtures and cable routing.
ช่วงอุณหภูมิ -40°C ถึง +150°C Confirm the selected configuration, test condition and mapping method.
Temperature performance Fluctuation ±0.3°C; uniformity 2.5°C Confirm stabilization condition, sensor points and whether the item is powered.
Temperature change Heating 3.0°C/min; cooling 1.0°C/min Confirm definition, ambient condition and loaded performance.
ประสิทธิภาพความชื้น 30% to 95% RH; fluctuation ±3.0% RH Confirm the valid combined temperature-RH operating envelope.
Controls and records 7-inch touch panel, programme and curve display, USB export State record interval, file format and report requirements.
Port and observation Φ50 mm test hole; heated double-layer observation window Confirm port quantity, cable sealing and fixture layout.

How the Climatic Control System Supports a Test

Control air temperature

Heating and refrigeration establish the programmed chamber-air temperature and transition rate.

Regulate moisture

Humidification and dehumidification maintain relative humidity within the selected operating envelope.

Distribute and record

Air circulation and controller records support a documented exposure across the usable workspace.

Powered specimens: live heat can affect cooling response and humidity control. Provide maximum watts and duty cycle before the refrigeration configuration is confirmed.

Published Chamber and Control Features

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

The current page lists a SUS304 stainless-steel inner chamber, cold-rolled painted outer enclosure, glass-fibre insulation and silicone door seal.

Racks and access

The listed configuration includes two adjustable stainless sample racks and a Φ50 mm test port with thermal insulation accessories and sealing plug.

Controller functions

The published 7-inch touch controller supports temperature-humidity programming, curve display, alarm indication and USB data export.

DERUI Desktop Chamber Reference Image

DERUI desktop constant temperature and humidity test chamber for laboratory environmental testing

Current DERUI product image. Final controller, ports, shelving and utilities follow the approved configuration.

Loading and Operating Discipline

Maintain airflow clearance

Keep specimen supports and fixtures clear of air supply and return paths; nominal volume is not usable loaded space.

Seal cable entries

Close unused cable-port area to limit ambient air and moisture leakage that can disturb the exposure.

Confirm water requirements

Follow the approved manual for water quality, feed arrangement, drainage and humidifier maintenance.

Define dwell start

State whether exposure begins at controller setpoint or after specimen sensors reach stabilization.

Record the loaded state

Document mass, location, fixture, powered operation and interfaces for repeatable later cycles.

Verify the procedure

Confirm standard edition, profile, monitoring and acceptance criteria before treating a cycle as compliance evidence.

Map the Chamber to the Test Procedure

The test standard and product specification define the programme. The chamber must cover every required setpoint, transition, dwell and tolerance in its selected configuration.

Reference การใช้งานทั่วไป Confirm before testing
IEC 60068-2-30 Cyclic damp heat Edition, cycle, transitions, condensation and recovery.
IEC 60068-2-78 Steady-state damp heat Temperature, RH, duration, stabilization and evaluation.
MIL-STD-810H Method 507.6 Tailored humidity exposure Procedure, climatic cycle, specimen operation and acceptance criteria.
JESD22-A101 / A100 Electronic-device moisture testing Applicable method, bias interfaces, safety and monitoring.

RFQ and FAT Checklist

Topic Information to provide or verify
Specimen Dimensions, mass, quantity, fixtures, material and powered heat.
Profile Temperature-RH points, transitions, dwell, cycles and tolerances.
Interfaces Ports, power, signals, thermocouples, network and data records.
เครื่องใช้ไฟฟ้า Voltage, frequency, current, water quality, drainage and ambient limits.
FAT Sensor map, stabilization, deviation, uniformity, alarms and report format.
Documents Approved drawing, bill of materials, manuals, electrical diagram and agreed calibration scope.

คำถามที่พบบ่อย

What is the published baseline workspace?

The current parameter table lists DR-H201/22/40 with a 22 L workspace measuring 300 × 300 × 250 mm. Confirm other capacities on their approved drawings.

What temperature and humidity ranges are published?

The 22 L parameter table lists -40°C to +150°C and 30% to 95% RH. The final configuration and usable envelope must be confirmed in the quotation.

Can the chamber record a test profile?

The published 7-inch touch controller supports programme input, curve display and USB export. Confirm record interval, file format and evidence requirements before procurement.

Can I test powered electronics inside?

State heat dissipation, duty cycle, cables and safety requirements in advance. The permitted loaded performance must be agreed for the actual configuration.

Which standards can it support?

The page references GB 5170 and older IEC 60068 equivalents. Specify the exact current standard edition and programme; equipment capability alone does not claim compliance.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send specimen dimensions, mass, quantity, live heat load, profile, cable needs, site utilities, data requirements and target method.

Configure a Compact Climate Chamber from the Real Test

Send the specimen drawing, temperature-humidity programme, powered load, test standard and data requirements. DERUI can confirm workspace, environmental range, controller records and installation details in the technical proposal.

Request a Desktop Chamber Proposal

เฟซบุ๊กLinkedInXRedditWhatsApp
รุ่น
DR-H201/22/40
ระบบ
ระบบควบคุมอุณหภูมิและความชื้นสมดุล (BTHC)
ปริมาณ
22ลิตร
ความสามารถในการบรรทุก
20กก.
ขนาดภายใน ก×ส×ล มม.
300×300×250
ขนาดภายนอก ก×ส×ล มม.
440×740×780
อุณหภูมิ

ประสิทธิภาพ
ช่วงอุณหภูมิ
 -40~+150℃
ความแปรปรวนของอุณหภูมิ
±0.3°C
ความสม่ำเสมอของอุณหภูมิ
2.5°C
อัตราการเปลี่ยนแปลงของอุณหภูมิ
อัตราการให้ความร้อน:3.0°C/นาที อัตราการระบายความร้อน:1.0°C/นาที
เวลาที่อุณหภูมิสุดขีดมาถึง
เวลาให้ความร้อน:จาก -40 ถึง +150℃ 60 นาที อัตราการระบายความร้อน:+20 ถึง -40°C 50 นาที
ความสามารถในการรับน้ำหนักความร้อนที่อนุญาต
อุณหภูมิของพื้นที่ทดสอบ+20°C , 300 วัตต์
ประสิทธิภาพความชื้น
ช่วงความชื้น
 30~95%rh
ความแปรปรวนของความชื้น
±3.0%rh
ความสามารถในการรับน้ำหนักความร้อนที่อนุญาต
เงื่อนไขพื้นที่ทดสอบ:+85℃ / 85%rh 300W
โครงสร้าง
วัสดุภายนอก
แผ่นอิเล็กโทรไลต์ขั้นสูงหนา 1.5 มม. + เคลือบป้องกันสนิม
วัสดุภายใน
สแตนเลส SUS304 หนา 1.2 มม.
ระบบจ่ายน้ำ (ชุดมาตรฐาน)
จ่ายน้ำอัตโนมัติ
ถังน้ำ (ตัวเลือก)
8 ลิตร
ระบบทำความเย็น
การทำความเย็นด้วยคอมเพรสเซอร์แบบอัดอากาศชั้นเดียวกลไก
คอมเพรสเซอร์
คอมเพรสเซอร์ปิดเต็มรูปแบบ
สารทำความเย็น
R-404A [R-449A พร้อมให้บริการตามคำขอ]
ไฟฟ้า
0.65 กิโลวัตต์
กลไกขยายตัว
วาล์วขยายตัวอิเล็กทรอนิกส์
ระดับเสียงรบกวน
60dB
  1. คำถาม: ห้องทดสอบอุณหภูมิคงที่และความชื้นคงที่แบบตั้งโต๊ะคืออะไร?
    A: เป็นอุปกรณ์ทดสอบสิ่งแวดล้อมขนาดกะทัดรัดที่ใช้จำลองสภาพอุณหภูมิและความชื้นที่แม่นยำสำหรับการทดสอบผลิตภัณฑ์หรือ ตัวอย่างขนาดเล็ก.

  2. คำถาม: มันควบคุมอุณหภูมิและความชื้นอย่างไร?
    A: ใช้ระบบทำความเย็นสำหรับการทำความเย็น ฮีตเตอร์สำหรับการให้ความร้อน และระบบเพิ่มความชื้น/ลดความชื้นเพื่อรักษาระดับความชื้นเฉพาะ.

  3. คำถาม: การใช้งานทั่วไปคืออะไร?
    A: ใช้สำหรับทดสอบอิเล็กทรอนิกส์ ยา ผลิตภัณฑ์แบตเตอรี่ วัสดุ และโบราณวัตถุในห้องปฏิบัติการวิจัยและสายการผลิต.

  4. คำถาม: ช่วงอุณหภูมิมาตรฐานคืออะไร?
    A: โดยทั่วไป -20°C ถึง +150°C โดยบางรุ่นสามารถให้ได้ -40°C ถึง +180°C.

  5. คำถาม: ช่วงความชื้นที่สามารถทำได้คืออะไร?
    A: โดยทั่วไป 20% ถึง 98% RH โดยบางรุ่นรองรับ 10% ถึง 98% RH.

  6. คำถาม: ความแม่นยำในการควบคุมอุณหภูมิคืออะไร?
    A: โดยปกติ ±0.5°C หรือดีกว่าในสภาพคงที่.

  7. คำถาม: ความแม่นยำในการควบคุมความชื้นเป็นอย่างไร?
    A: โดยทั่วไป ±2.5% RH หรือดีกว่า.

  8. คำถาม: ต้องการแหล่งจ่ายไฟแบบไหน?
    A: รุ่นส่วนใหญ่ทำงานบนไฟฟ้ากระแสสลับมาตรฐาน 220V/50Hz หรือ 110V/60Hz.

  9. คำถาม: ต้องการพื้นที่เท่าไหร่?
    A: ในฐานะอุปกรณ์ตั้งโต๊ะ มักต้องการพื้นที่บนโต๊ะไม่เกิน 1 ตารางเมตร.

  10. คำถาม: ตัวเลือกอินเทอร์เฟซที่มีให้เลือกคืออะไร?
    A: หน่วยสมัยใหม่ส่วนใหญ่มีหน้าจอสัมผัสและรองรับการเชื่อมต่อ USB/RS485/Ethernet.

  11. คำถาม: ควรสอบเทียบบ่อยแค่ไหน?
    A: แนะนำทุกปีหรือทุก 6 เดือนสำหรับงานที่ต้องการความแม่นยำสูง.

  12. คำถาม: ต้องการการบำรุงรักษาอะไรบ้าง?
    A: ทำความสะอาดฟิลเตอร์เป็นประจำ ตรวจสอบระดับสารทำความเย็น และทำความสะอาดเซ็นเซอร์ความชื้น.

  13. คำถาม: สามารถโปรแกรมรอบทดสอบซับซ้อนได้หรือไม่?
    A: ได้ รุ่นส่วนใหญ่รองรับการโปรแกรมหลายช่วงสำหรับรอบอุณหภูมิ/ความชื้นที่ซับซ้อน.

  14. คำถาม: มีคุณสมบัติด้านความปลอดภัยอะไรบ้าง?
    A: โดยทั่วไปรวมถึงการป้องกันอุณหภูมิสูงเกินไป การป้องกันการเผาแห้ง และการป้องกันดีเลย์คอมเพรสเซอร์.

  15. คำถาม: จะเลือกโมเดลที่เหมาะสมอย่างไร?
    A: พิจารณาขนาดตัวอย่าง ช่วงอุณหภูมิ/ความชื้นที่ต้องการ ความแม่นยำ และพื้นที่บนโต๊ะที่มีอยู่.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
ข้อความข้อความ

ขอใบเสนอราคา