Stol usti doimiy harorat va namlik sinov kamerasi

The DERUI desktop constant temperature and humidity test chamber is a compact laboratory climate chamber for small specimens and component-level environmental conditioning. The published DR-H201/22/40 baseline provides a 22 L workspace with programmable temperature-humidity control, curve display and USB record export. Confirm the final range, powered load and utilities in the approved technical proposal.

Published Model DR-H201/22/40
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 22 L · 300 × 300 × 250 mm
Published Temperature -40°C dan +150°C gacha
Published Humidity 30% to 95% RH
Controls & Records 7-inch touch controller, programme and curve display, USB export
Before Quotation Confirm specimen size, powered load, profile, data record and local utilities
Xavfsiz va ishonchli
yaxshi tayyorlangan
Sifatni ta'minlash
moslashtirish
XabarWhatsApp
Hotline raqami 15580327593
  • Mahsulot tafsilotlari
  • Texnik parametrlar
  • Savollar va Javoblar
  • Biz bilan bog'laning

Compact Laboratory Climate Simulation

Desktop Constant Temperature and Humidity Test Chamber

Use a compact DERUI climate chamber for small specimens, component development and laboratory environmental conditioning. The published DR-H201/22/40 baseline combines programmable temperature and humidity control in a 22 L workspace. Final range, capacity and utilities follow the approved technical proposal.

Engineering basis: desktop footprint does not define loaded performance. State the specimen envelope, fixtures, powered heat, required profile and data records before selecting the configuration.
Published model baselineDR-H201/22/40
Published workspace22 L · 300 × 300 × 250 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits-40°C dan +150°C gacha
Published humidity range30% to 95% RH

Where a Desktop Climate Chamber Fits

The compact chamber supports component-level environmental conditioning where laboratory space is limited and specimen size allows airflow to remain clear. It is selected from the required exposure, not merely from a volume label.

Electronic assemblies

Condition PCBs, connectors, control modules, sensors and compact assemblies under defined temperature-humidity programmes.

Materials and research

Run controlled damp-heat exposure, comparative ageing and conditioning studies with documented specimen placement.

Small product development

Evaluate packaged components and small devices before moving to a larger floor-standing chamber for batch or fixture-heavy testing.

Published DR-H201/22/40 Configuration

Narsa Published value Procurement note
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 22 L; 300 × 300 × 250 mm Confirm usable volume after racks, fixtures and cable routing.
Harorat diapazoni -40°C dan +150°C gacha Confirm the selected configuration, test condition and mapping method.
Temperature performance Fluctuation ±0.3°C; uniformity 2.5°C Confirm stabilization condition, sensor points and whether the item is powered.
Temperature change Heating 3.0°C/min; cooling 1.0°C/min Confirm definition, ambient condition and loaded performance.
Namlik xususiyatlari 30% to 95% RH; fluctuation ±3.0% RH Confirm the valid combined temperature-RH operating envelope.
Controls and records 7-inch touch panel, programme and curve display, USB export State record interval, file format and report requirements.
Port and observation Φ50 mm test hole; heated double-layer observation window Confirm port quantity, cable sealing and fixture layout.

How the Climatic Control System Supports a Test

Control air temperature

Heating and refrigeration establish the programmed chamber-air temperature and transition rate.

Regulate moisture

Humidification and dehumidification maintain relative humidity within the selected operating envelope.

Distribute and record

Air circulation and controller records support a documented exposure across the usable workspace.

Powered specimens: live heat can affect cooling response and humidity control. Provide maximum watts and duty cycle before the refrigeration configuration is confirmed.

Published Chamber and Control Features

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

The current page lists a SUS304 stainless-steel inner chamber, cold-rolled painted outer enclosure, glass-fibre insulation and silicone door seal.

Racks and access

The listed configuration includes two adjustable stainless sample racks and a Φ50 mm test port with thermal insulation accessories and sealing plug.

Controller functions

The published 7-inch touch controller supports temperature-humidity programming, curve display, alarm indication and USB data export.

DERUI Desktop Chamber Reference Image

DERUI desktop constant temperature and humidity test chamber for laboratory environmental testing

Current DERUI product image. Final controller, ports, shelving and utilities follow the approved configuration.

Loading and Operating Discipline

Maintain airflow clearance

Keep specimen supports and fixtures clear of air supply and return paths; nominal volume is not usable loaded space.

Seal cable entries

Close unused cable-port area to limit ambient air and moisture leakage that can disturb the exposure.

Confirm water requirements

Follow the approved manual for water quality, feed arrangement, drainage and humidifier maintenance.

Define dwell start

State whether exposure begins at controller setpoint or after specimen sensors reach stabilization.

Record the loaded state

Document mass, location, fixture, powered operation and interfaces for repeatable later cycles.

Verify the procedure

Confirm standard edition, profile, monitoring and acceptance criteria before treating a cycle as compliance evidence.

Map the Chamber to the Test Procedure

The test standard and product specification define the programme. The chamber must cover every required setpoint, transition, dwell and tolerance in its selected configuration.

Reference Odatda foydalanish Confirm before testing
IEC 60068-2-30 Cyclic damp heat Edition, cycle, transitions, condensation and recovery.
IEC 60068-2-78 Steady-state damp heat Temperature, RH, duration, stabilization and evaluation.
MIL-STD-810H Method 507.6 Tailored humidity exposure Procedure, climatic cycle, specimen operation and acceptance criteria.
JESD22-A101 / A100 Electronic-device moisture testing Applicable method, bias interfaces, safety and monitoring.

RFQ and FAT Checklist

Topic Information to provide or verify
Specimen Dimensions, mass, quantity, fixtures, material and powered heat.
Profile Temperature-RH points, transitions, dwell, cycles and tolerances.
Interfaces Ports, power, signals, thermocouples, network and data records.
Kommunal xizmatlar Voltage, frequency, current, water quality, drainage and ambient limits.
FAT Sensor map, stabilization, deviation, uniformity, alarms and report format.
Documents Approved drawing, bill of materials, manuals, electrical diagram and agreed calibration scope.

Ko‘p so‘raladigan savollar

What is the published baseline workspace?

The current parameter table lists DR-H201/22/40 with a 22 L workspace measuring 300 × 300 × 250 mm. Confirm other capacities on their approved drawings.

What temperature and humidity ranges are published?

The 22 L parameter table lists -40°C to +150°C and 30% to 95% RH. The final configuration and usable envelope must be confirmed in the quotation.

Can the chamber record a test profile?

The published 7-inch touch controller supports programme input, curve display and USB export. Confirm record interval, file format and evidence requirements before procurement.

Can I test powered electronics inside?

State heat dissipation, duty cycle, cables and safety requirements in advance. The permitted loaded performance must be agreed for the actual configuration.

Which standards can it support?

The page references GB 5170 and older IEC 60068 equivalents. Specify the exact current standard edition and programme; equipment capability alone does not claim compliance.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Send specimen dimensions, mass, quantity, live heat load, profile, cable needs, site utilities, data requirements and target method.

Configure a Compact Climate Chamber from the Real Test

Send the specimen drawing, temperature-humidity programme, powered load, test standard and data requirements. DERUI can confirm workspace, environmental range, controller records and installation details in the technical proposal.

Request a Desktop Chamber Proposal

FacebookLinkedInXRedditWhatsApp
Model
DR-H201/22/40
Tizim
Balanс temperatura va namlikni boshqarish tizimi (BTHC)
Hajm
22L
Yuklash qobiliyati
20KG
Ichki o'lcham W×H×D mm
300×300×250
Tashqi o'lcham W×H×D mm
440×740×780
Harorat

Ishlash ko'rsatkichlari
Harorat diapazoni
 -40~+150℃
Harorat o'zgarishi
±0.3°C
Harorat birxilligi
2.5°C
Harorat o'zgarish tezligi
Isitish tezligi: 3.0°C/min Sovutish tezligi: 1.0°C/min
Ekstremal haroratga yetish vaqti
Isitish vaqti: -40 dan +150°C gacha 60 min Sovutish tezligi: +20 dan -40°C gacha 50 min
Ruxsat etilgan issiqlik yuklamasi
Test hududining harorati +20°C, 300 Vt
Namlik xususiyatlari
Namlik diapazoni
 30~95%rh
Namlik o'zgarishi
±3.0%rh
Ruxsat etilgan issiqlik yuklamasi
Test hududi sharoitlari: +85°C / 85%rh 300Vt
Tuzilma
Tashqi material
1.5mm qalinlikdagi FC ilg'or elektrolitik plita + korroziyaga qarshi bo'yoq bilan püskürtme
Ichki material
1.2mm qalinlikdagi SUS304 zanglamaydigan po'lat
Suv ta'minoti tizimi (standart konfiguratsiya)
Avtomatik suv ta'minoti
Suv tanki (ixtiyoriy)
8 L
Sovutish tizimi
Mexanik bir bosqichli siqishni sovutish
Kompresor
To‘liq yopiq kompresor
Sovutgich
R-404A [R-449A so‘rov bo‘yicha mavjud]
Quvvat
0.65 kVt
Uzaytirish mexanizmi
Elektron kengaytirish valfi
Shovqin darajasi
60dB
  1. Q: Stol usti doimiy harorat va namlik sinov kamerasi nima?
    A: U kichik mahsulotlar yoki namunalarni sinash uchun aniq harorat va namlik sharoitlarini simulyatsiya qilish uchun ishlatiladigan kichik muhit sinov qurilmasidir.

  2. Q: U harorat va namlikni qanday boshqaradi?
    A: U sovutish uchun sovutish tizimidan, isitish uchun isitish elementlaridan va ma'lum namlik darajalarini saqlash uchun namlik va namlikni kamaytirish tizimidan foydalanadi.

  3. Q: Uning odatiy qo‘llanilish joylari nima?
    A: Elektronika, farmatsevtika, batareyalar, materiallar va madaniy yodgorliklarni tadqiqot laboratoriyalari va ishlab chiqarish liniyalarida sinash uchun keng qo‘llaniladi.

  4. Q: Standart harorat diapazoni nima?
    A: Odatiy -20°C dan +150°C gacha, ba'zi modellarda -40°C dan +180°C gacha bo‘ladi.

  5. S: Qanday namlik diapazoni erishilishi mumkin?
    A: Umuman olganda 20% dan 98% gacha RH, ba'zi modellarda 10% dan 98% gacha RH ni qo'llab-quvvatlaydi.

  6. S: Haroratni nazorat qilish qanchalik aniq?
    A: Odatiy ravishda barqaror holatda ±0.5°C yoki undan yaxshiroq.

  7. S: Namlikni nazorat qilish aniqligi haqida nima deyish mumkin?
    A: Odatiy ravishda ±2.5% RH yoki undan yaxshiroq.

  8. S: Qanday quvvat manbai kerak?
    A: Ko'p modellarda standart AC 220V/50Hz yoki 110V/60Hz quvvat ishlatiladi.

  9. S: Qancha joy talab qilinadi?
    A: Stol usti qurilma sifatida, odatda 1m² dan kam stol joyini talab qiladi.

  10. S: Qaysi interfeys variantlari mavjud?
    A: Ko'p zamonaviy qurilmalar sensorli ekran boshqaruvi va USB/RS485/Ethernet ulanishini qo'llab-quvvatlaydi.

  11. S: Uni qanchalik tez-tez kalibrlash kerak?
    A: Tavsiya etiladi yillik yoki muhim ilovalar uchun har 6 oyda kalibrlash.

  12. S: Qanday texnik xizmat ko'rsatish talab qilinadi?
    A: Filtrlarga muntazam tozalash, sovutgich darajalarini tekshirish va namlik sensorlarini tozalash.

  13. S: Murakkab test sikllarini dasturlash mumkinmi?
    A: Ha, ko'p modellarda murakkab harorat/nemlik sikllari uchun ko'p segmentli dasturlash qo'llab-quvvatlanadi.

  14. S: Qaysi xavfsizlik xususiyatlari mavjud?
    A: Odatiy ravishda ortiq haroratdan himoya, quruq yondirishdan himoya va kompressor kechiktirish himoyasini o'z ichiga oladi.

  15. Sizga qanday to'g'ri modelni tanlash haqida savol berildi?
    A: Namuna hajmi, kerakli harorat/namlik diapazoni, aniqlik ehtiyojlari va mavjud stend joyini hisobga oling.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
XabarXabar

Taklif so'rang