Calle Shugang 1, No. 3, Town de Hongmei, Ciudad de Dongguan, Provincia de Guangdong, China

Fabricante de cámaras de prueba ambiental con 20 años de experienciaMás de 3000 entregas a clientes en todo el mundo           Correo electrónico: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Cámara de prueba de polvo y arena DR-H508

La DERUI DR-H508-2 1000 L sand dust test chamber provides a 1000 × 1000 × 1000 mm stainless-steel workspace with dust recirculation, pneumatic vibration, timed dust heating and provision for specimen pressure connection. Confirm the selected procedure, dust medium and vacuum package before ordering.

Modelo DR-H508-2
Dimensiones internas 1000 × 1000 × 1000 mm (1,000 L)
Published Dust Loading 2 kg/m³
Test Functions Dust circulation, vibration, timed heating and test timing
Vacuum Package Connection components published; vacuum pump specified separately
Fuente de alimentación AC380 V ±10%, 50 Hz, three-phase five-wire
Segura y confiable
bien hecha
Garantía de calidad
personalización
MensajeWhatsApp
Número de línea directa 15580327593
  • Detalles del producto
  • Parámetros técnicos
  • Preguntas frecuentes
  • Contáctanos
1 m³ Recirculating Sand and Dust Chamber

DR-H508-2 1000 L Sand Dust Test Chamber

A floor-standing 1,000 L configuration for enclosure sealing tests on automotive parts, electrical products, instruments and industrial housings. The chamber combines a stainless-steel workspace, dust recirculation, pneumatic vibration, dust heating and provision for specimen pressure connection.

Page role: this page describes the published 1,000 L DR-H508-2 hardware configuration. For method-led selection across different chamber sizes and enclosure categories, use the dust ingress test chamber configuration page.
Internal dimensionscURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Nominal workspace1,000 L
Published dust loading2 kg/m³
PotenciaAC380 V ±10%, 50 Hz, three-phase five-wire

Where This 1,000 L Configuration Fits

Automotive assemblies

Headlamps, instrument housings, electrical covers, steering components, locks and seals that fit the 1 m³ workspace and required clearances.

Electrical enclosures

Control boxes, appliances, instruments and outdoor electronics evaluated for dust entry under a specified enclosure-protection procedure.

Production and design verification

Use repeatable timing, dust circulation and specimen connections for engineering validation, incoming checks or periodic quality control.

Published DR-H508-2 Specifications

Artículo Published value Technical-agreement check
Internal dimensions (D × W × H) cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Confirm usable clearance, shelves and specimen orientation.
External dimensions (D × W × H) 1480 × 1260 × 1980 mm Check doorway, transport route, service and cleaning clearance.
Metal mesh wire / nominal pitch 50 μm / 75 μm Confirm terminology and required sieve specification for the selected method.
Dust consumption 2 kg/m³ Treat as published loading, not continuously measured airborne concentration.
Vibration timer Up to 99 min 59 s Confirm cycle logic and interval setting.
Test timer Up to 99 h 59 min Confirm required duration, interruptions and accumulated-time handling.
Specimen power socket Dustproof AC220 V, 16 A Confirm specimen current, heat and destination socket arrangement.
Fuente de alimentación AC380 V ±10%, 50 Hz, three-phase five-wire Confirm destination voltage and protective device before production.

Construction and Control System

Assembly Published construction or function Por qué importa
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Powder-coated steel exterior; SUS stainless-steel mirror-finish interior Supports cleaning, durability and dust containment.
Door and observation Transparent glass observation door Allows visual checks without opening during the active test.
Dust circulation Motor de aleación cerrado de bajo ruido, ventilador centrífugo de múltiples aspas Blows settled dust into the workspace for recirculation.
Pneumatic vibration Vibration device and bottom dust-replacement arrangement Helps return accumulated powder to the circulation path.
Dust heating Stainless-steel mica-sheet heating sleeve with timed control Helps prevent moisture-related dust clumping; it is not specimen climate control.
Controlador Touchscreen with PLC programme and working-time display Controls test sequence, timing and operating status.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Fixed casters at the chamber base Supports positioning while retaining stable placement.

Vacuum and Safety Configuration

Pressure connection components

The published package includes a pressure gauge, air filter, pressure-regulating tee and connecting pipe. Confirm range, accuracy, flow measurement and specimen connection.

Vacuum pump boundary

The current specification states that the vacuum pump is supplied separately and must be specified when ordering. Do not assume it is included.

Equipment protection

Published protections include leakage, short circuit, over-temperature, motor overheat, over-current, phase-loss and phase-sequence protection.

1000 L Sand Dust Chamber Reference Image

Cámara de prueba de arena DR-H508

Reference image for the DR-H508 series. Verify the ordered 1000 × 1000 × 1000 mm workspace, controller, ports, vacuum components and destination power against the approved drawing.

Keep the Two Dust Pages Separate

Page Primary search intent Use it when
This 1000 L sand dust chamber page Specific DR-H508-2 model, 1 m³ dimensions, construction, timers and electrical configuration The specimen fits the published chamber and the buyer needs a concrete equipment specification.
Dust ingress test chamber page IP5X/IP6X method selection, enclosure category, pressure conditions and configurable chamber sizing The buyer is still determining the correct method and configuration.
Dedicated blowing sand/dust system MIL-STD-810 Method 510 profiles The requirement specifies controlled high airflow, particle feed and tailored blowing sand or dust conditions.
Importante: product naming alone does not make this cabinet a MIL-STD-810 blowing-sand system. Confirm the exact standard, revision, procedure, particle feed, airflow and environmental profile before making that claim.

Commissioning and Routine Control

Verify installation

Check floor loading, access clearance, protective earth, three-phase supply and ventilation.

Verify the test medium

Confirm dust specification, dry condition, sieve suitability, loading and reuse/replacement rule.

Verify specimen setup

Record orientation, seals, cable glands, powered state and any pressure connection.

Run the approved cycle

Set circulation, vibration, heating and test timers according to the selected procedure.

Recover and clean

Allow dust to settle, protect operators and avoid moving external powder into the enclosure during handling.

Inspect and document

Apply the agreed internal inspection, functional checks and acceptance criteria.

Factory Acceptance Checklist

Verificar Recommended verification
Dimensions and access Measure workspace, door opening and external envelope; verify shelves and caster arrangement.
Dust circuit Demonstrate fan, vibration, heating, recovery path and timer sequence.
Vacuum components Verify supplied parts, connection, pressure indication and ordered pump boundary.
Specimen power Confirm socket voltage/current, isolation and powered-load restrictions.
Seguridad Test leakage, short-circuit, over-temperature, motor, over-current and phase protections.
Documentación Check manual, wiring diagram, inspection record, packing list and agreed calibration evidence.

Preguntas Frecuentes

Is this page the same product as the dust ingress test chamber page?

They are related, but the page roles are different. This page presents the published 1,000 L DR-H508-2 configuration; the other page explains method-led IP5X/IP6X selection and custom sizing.

Is the vacuum pump included?

The current specification says it is supplied separately and must be specified when ordering. Confirm the pump, control range and flow requirements in the quotation.

Does 2 kg/m³ mean measured airborne dust concentration?

No. It is published as dust consumption/loading. Do not describe it as continuous concentration measurement unless the ordered system includes verified instrumentation.

Does the dust heating system control specimen temperature?

No. Its stated function is to reduce dust adhesion and clumping. It is not a temperature-conditioning system for the specimen.

Can it perform MIL-STD-810 blowing sand?

Not from the published configuration alone. Method 510 requires separate confirmation of particle feed, airflow, temperature and procedure-specific controls.

What must be confirmed before ordering?

Confirm specimen size and mass, standard, enclosure category, dust, pressure conditions, powered state, destination power, accessories, FAT and documentation.

Confirm the 1 m³ Configuration Against the Specimen

Send the enclosure drawing, required procedure, dust, pressure condition and powered state. DERUI can confirm whether the published DR-H508-2 configuration fits or a different chamber is required.

Request a DR-H508-2 Review

FacebookLinkedInXRedditWhatsApp
Artículo Detalles
Modelo DR -H508-2
Dimensiones internas (D×W×H) mm 1000×1000×1000
Dimensiones externas (D×W×H) mm 1480×1260×1980
Diámetro del alambre de malla metálica 50 μm
Paso nominal entre hilos 75 μm
Consumo de polvo 2 kg/m³
Tiempo de vibración 99 minutos y 59 segundos
Tiempo de prueba 99 horas y 59 minutos
Enchufe de potencia de la muestra de prueba Enchufe a prueba de polvo, AC220V, 16A
Controlador Pantalla táctil controlada por programa PLC importado, con tiempo de trabajo y otra información mostrada en chino
Sistema de vacío Equipado con manómetro, filtro de aire, tee regulador de presión, tubo de conexión (bomba de vacío a ser proporcionada por separado, por favor especifique al hacer el pedido)
Ventilador de circulación Motor de aleación cerrado de bajo ruido, ventilador centrífugo de múltiples aspas
Sistema de calefacción de polvo Manguito de calefacción de hoja de mica de acero inoxidable
Voltaje de alimentación AC380V ± 10%, T3T, 50Hz, sistema trifásico de cinco hilos
Protección de seguridad Protección contra fugas, protección contra cortocircuitos, protección contra sobretemperatura, protección contra sobrecalentamiento del motor, protección contra sobrecorriente

1.¿Cuál es el propósito principal de una cámara de prueba de arena y polvo?
Se utiliza para simular un entorno de arena y polvo para probar la estanqueidad, resistencia al desgaste y fiabilidad de los productos bajo erosión de viento y arena. Es aplicable a industrias como la automotriz, electrónica y militar.

2. ¿A qué estándares cumple la cámara de prueba de arena y polvo?
Cumple con estándares internacionales como GB/T 2423.37 (Pruebas de arena y polvo para productos eléctricos y electrónicos) y IEC 60068-2-68, garantizando la autoridad de los resultados de la prueba.

3. ¿Cómo se controla la concentración de polvo en la cámara de prueba de polvo?
La concentración de polvo puede ajustarse con precisión desde 0.1 hasta 5 g/m³ mediante un sistema de flujo de aire ajustable y un caudalímetro de precisión, satisfaciendo diversos requisitos de prueba.

4. ¿Cuál es el rango de velocidad del viento de la cámara de prueba?
Generalmente soporta ajuste de velocidad del viento de 1 a 10 m/s para simular entornos naturales de viento y arena. Algunos modelos de alta gama pueden personalizarse para velocidades de viento superiores.

5. ¿En qué industrias es aplicable la cámara de prueba de polvo?
Se utiliza ampliamente en los campos de automoción (filtros, lámparas), electrónica (sellos, equipos exteriores), industria militar (equipo de protección), aeroespacial, etc.

6. ¿Cómo limpiar la cámara de prueba de arena y polvo?
Después de la prueba, se debe apagar el equipo. Esperar a que la arena y el polvo se asienten y luego limpiar el interior con una aspiradora. Además, reemplazar el filtro regularmente para evitar que la arena y el polvo obstruyan y afecten la velocidad del viento.

7. ¿Puede la cámara de prueba de arena y polvo probar niveles de protección IP?
¡Sí! Ajustando la concentración de arena y polvo y el tiempo de soplado, puede verificar si el producto cumple con los estándares IP5X (a prueba de polvo) o IP6X (totalmente a prueba de polvo).

8. ¿Cuáles son los requisitos de material para la cámara de prueba?
La pared interior debe estar hecha de acero inoxidable 304 o recubierta con material anticorrosivo para garantizar resistencia al desgaste y a la corrosión. La ventana de observación debe ser de vidrio templado para facilitar la observación en tiempo real del proceso de prueba.

9. ¿Requiere la cámara de prueba de arena y polvo control de temperatura y humedad?
Algunos modelos soportan control de enlace de temperatura y humedad (como alta temperatura + arena y polvo), para simular entornos más severos (como tormentas de arena en desiertos con altas temperaturas), pero el modelo básico solo requiere pruebas con arena y polvo secos.

10. ¿Cómo evaluar el rendimiento de una cámara de prueba de arena y polvo?
Los indicadores clave incluyen la uniformidad de la concentración de arena y polvo, la estabilidad de la velocidad del viento, el rendimiento de estanqueidad y la facilidad de operación. Se recomienda elegir equipos que cumplan con los estándares y tengan buen servicio postventa.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MensajeMensaje

Solicitar una Cotización