Étage 1, No. 3, Avenue Shugang, Ville de Hongmei, Dongguan, Province du Guangdong, Chine

Fabricant de chambres d'essai environnemental depuis 20 ansPlus de 3000 livraisons clients dans le monde entier    Email : shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Chambre d'essai de poussière de sable DR-H508

Le DERUI DR-H508-2 1000 L sand dust test chamber provides a 1000 × 1000 × 1000 mm stainless-steel workspace with dust recirculation, pneumatic vibration, timed dust heating and provision for specimen pressure connection. Confirm the selected procedure, dust medium and vacuum package before ordering.

Modèle DR-H508-2
Dimensions internes 1000 × 1000 × 1000 mm (1,000 L)
Published Dust Loading 2 kg/m³
Test Functions Dust circulation, vibration, timed heating and test timing
Vacuum Package Connection components published; vacuum pump specified separately
Alimentation électrique AC380 V ±10%, 50 Hz, three-phase five-wire
Sûr et fiable
bien fabriqué
Assurance qualité
personnalisation
MessageWhatsApp
Numéro de hotline 15580327593
  • Détails du produit
  • Paramètres techniques
  • FAQ
  • Contactez-nous
1 m³ Recirculating Sand and Dust Chamber

DR-H508-2 1000 L Sand Dust Test Chamber

A floor-standing 1,000 L configuration for enclosure sealing tests on automotive parts, electrical products, instruments and industrial housings. The chamber combines a stainless-steel workspace, dust recirculation, pneumatic vibration, dust heating and provision for specimen pressure connection.

Page role: this page describes the published 1,000 L DR-H508-2 hardware configuration. For method-led selection across different chamber sizes and enclosure categories, use the dust ingress test chamber configuration page.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limitscURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Nominal workspace1,000 L
Published dust loading2 kg/m³
PuissanceAC380 V ±10%, 50 Hz, three-phase five-wire

Where This 1,000 L Configuration Fits

Automotive assemblies

Headlamps, instrument housings, electrical covers, steering components, locks and seals that fit the 1 m³ workspace and required clearances.

Electrical enclosures

Control boxes, appliances, instruments and outdoor electronics evaluated for dust entry under a specified enclosure-protection procedure.

Production and design verification

Use repeatable timing, dust circulation and specimen connections for engineering validation, incoming checks or periodic quality control.

Published DR-H508-2 Specifications

Article Published value Technical-agreement check
Internal dimensions (D × W × H) cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Confirm usable clearance, shelves and specimen orientation.
External dimensions (D × W × H) 1480 × 1260 × 1980 mm Check doorway, transport route, service and cleaning clearance.
Metal mesh wire / nominal pitch 50 μm / 75 μm Confirm terminology and required sieve specification for the selected method.
Dust consumption 2 kg/m³ Treat as published loading, not continuously measured airborne concentration.
Vibration timer Up to 99 min 59 s Confirm cycle logic and interval setting.
Test timer Up to 99 h 59 min Confirm required duration, interruptions and accumulated-time handling.
Specimen power socket Dustproof AC220 V, 16 A Confirm specimen current, heat and destination socket arrangement.
Alimentation électrique AC380 V ±10%, 50 Hz, three-phase five-wire Confirm destination voltage and protective device before production.

Construction and Control System

Assembly Published construction or function Pourquoi c'est important
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Powder-coated steel exterior; SUS stainless-steel mirror-finish interior Supports cleaning, durability and dust containment.
Door and observation Transparent glass observation door Allows visual checks without opening during the active test.
Dust circulation Moteur en alliage à faible bruit, ventilateur centrifuge à plusieurs pales Blows settled dust into the workspace for recirculation.
Pneumatic vibration Vibration device and bottom dust-replacement arrangement Helps return accumulated powder to the circulation path.
Dust heating Stainless-steel mica-sheet heating sleeve with timed control Helps prevent moisture-related dust clumping; it is not specimen climate control.
Contrôleur Touchscreen with PLC programme and working-time display Controls test sequence, timing and operating status.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Fixed casters at the chamber base Supports positioning while retaining stable placement.

Vacuum and Safety Configuration

Pressure connection components

The published package includes a pressure gauge, air filter, pressure-regulating tee and connecting pipe. Confirm range, accuracy, flow measurement and specimen connection.

Vacuum pump boundary

The current specification states that the vacuum pump is supplied separately and must be specified when ordering. Do not assume it is included.

Equipment protection

Published protections include leakage, short circuit, over-temperature, motor overheat, over-current, phase-loss and phase-sequence protection.

1000 L Sand Dust Chamber Reference Image

Chambre d'essai de sable DR-H508

Reference image for the DR-H508 series. Verify the ordered 1000 × 1000 × 1000 mm workspace, controller, ports, vacuum components and destination power against the approved drawing.

Keep the Two Dust Pages Separate

Page Primary search intent Use it when
This 1000 L sand dust chamber page Specific DR-H508-2 model, 1 m³ dimensions, construction, timers and electrical configuration The specimen fits the published chamber and the buyer needs a concrete equipment specification.
Dust ingress test chamber page IP5X/IP6X method selection, enclosure category, pressure conditions and configurable chamber sizing The buyer is still determining the correct method and configuration.
Dedicated blowing sand/dust system MIL-STD-810 Method 510 profiles The requirement specifies controlled high airflow, particle feed and tailored blowing sand or dust conditions.
Important : product naming alone does not make this cabinet a MIL-STD-810 blowing-sand system. Confirm the exact standard, revision, procedure, particle feed, airflow and environmental profile before making that claim.

Commissioning and Routine Control

Verify installation

Check floor loading, access clearance, protective earth, three-phase supply and ventilation.

Verify the test medium

Confirm dust specification, dry condition, sieve suitability, loading and reuse/replacement rule.

Verify specimen setup

Record orientation, seals, cable glands, powered state and any pressure connection.

Run the approved cycle

Set circulation, vibration, heating and test timers according to the selected procedure.

Recover and clean

Allow dust to settle, protect operators and avoid moving external powder into the enclosure during handling.

Inspect and document

Apply the agreed internal inspection, functional checks and acceptance criteria.

Factory Acceptance Checklist

Vérifier Recommended verification
Dimensions and access Measure workspace, door opening and external envelope; verify shelves and caster arrangement.
Dust circuit Demonstrate fan, vibration, heating, recovery path and timer sequence.
Vacuum components Verify supplied parts, connection, pressure indication and ordered pump boundary.
Specimen power Confirm socket voltage/current, isolation and powered-load restrictions.
Sécurité Test leakage, short-circuit, over-temperature, motor, over-current and phase protections.
Documentation Check manual, wiring diagram, inspection record, packing list and agreed calibration evidence.

Foire Aux Questions

Is this page the same product as the dust ingress test chamber page?

They are related, but the page roles are different. This page presents the published 1,000 L DR-H508-2 configuration; the other page explains method-led IP5X/IP6X selection and custom sizing.

Is the vacuum pump included?

The current specification says it is supplied separately and must be specified when ordering. Confirm the pump, control range and flow requirements in the quotation.

Does 2 kg/m³ mean measured airborne dust concentration?

No. It is published as dust consumption/loading. Do not describe it as continuous concentration measurement unless the ordered system includes verified instrumentation.

Does the dust heating system control specimen temperature?

No. Its stated function is to reduce dust adhesion and clumping. It is not a temperature-conditioning system for the specimen.

Can it perform MIL-STD-810 blowing sand?

Not from the published configuration alone. Method 510 requires separate confirmation of particle feed, airflow, temperature and procedure-specific controls.

What must be confirmed before ordering?

Confirm specimen size and mass, standard, enclosure category, dust, pressure conditions, powered state, destination power, accessories, FAT and documentation.

Confirm the 1 m³ Configuration Against the Specimen

Send the enclosure drawing, required procedure, dust, pressure condition and powered state. DERUI can confirm whether the published DR-H508-2 configuration fits or a different chamber is required.

Request a DR-H508-2 Review

FacebookLinkedInXRedditWhatsApp
Article Détails
Modèle DR -H508-2
Dimensions internes (L×l×H) mm 1000×1000×1000
Dimensions extérieures (L×l×H) mm 1480×1260×1980
Diamètre du fil de la grille métallique 50 μm
Pas nominal entre les fils 75 μm
Consommation de poussière 2 kg/m³
Temps de vibration 99 minutes et 59 secondes
Temps de test 99 heures et 59 minutes
Prise électrique pour spécimen de test Prise étanche à la poussière, AC220V, 16A
Contrôleur Écran tactile contrôlé par un programme PLC importé, avec affichage du temps de fonctionnement et d'autres informations en chinois
Système de vide Équipé d'un manomètre, filtre à air, T de régulation de pression, tuyau de raccordement (pompe à vide à fournir séparément, veuillez préciser lors de la commande)
Ventilateur de circulation Moteur en alliage à faible bruit, ventilateur centrifuge à plusieurs pales
Système de chauffage à poussière Manchon chauffant en mica en acier inoxydable
Tension d'alimentation électrique AC380V ± 10%, 50Hz, système triphasé à cinq fils
Protection de la sécurité Protection contre les fuites, protection contre les courts-circuits, protection contre la surchauffe, protection contre la surchauffe du moteur, protection contre les surintensités

1. Quel est le but principal d'une chambre d'essai de sable et de poussière ?
Elle est utilisée pour simuler un environnement de sable et de poussière afin de tester l'étanchéité, la résistance à l'usure et la fiabilité des produits sous l'érosion par le vent et le sable. Elle est applicable à des industries telles que l'automobile, l'électronique et la militaire.

2. À quelles normes la chambre d'essai de sable et de poussière est-elle conforme ?
Elle est conforme aux normes internationales telles que GB/T 2423.37 (Test de sable et de poussière pour les produits électriques et électroniques) et IEC 60068-2-68, garantissant la fiabilité des résultats des tests.

3. Comment la concentration de poussière dans la chambre d'essai de poussière est-elle contrôlée ?
La concentration de poussière peut être ajustée précisément de 0,1 à 5 g/m³ grâce à un système de flux d'air réglable et à un débitmètre de précision, répondant à diverses exigences de test.

4. Quelle est la plage de vitesse du vent de la chambre d'essai ?
Elle supporte généralement un réglage de la vitesse du vent de 1 à 10 m/s pour simuler des environnements naturels de vent et de sable. Certains modèles haut de gamme peuvent être personnalisés pour des vitesses de vent plus élevées.

5. Dans quels secteurs la chambre d'essai de poussière est-elle applicable ?
Elle est largement utilisée dans les domaines de l'automobile (filtres, lampes), de l'électronique (joints, équipements extérieurs), de l'industrie militaire (équipements de protection), de l'aérospatiale, etc.

6. Comment nettoyer la chambre d'essai de sable et de poussière ?
Après le test, l'équipement doit être éteint. Attendre que le sable et la poussière se déposent, puis nettoyer l'intérieur avec un aspirateur. Remplacer également le filtre régulièrement pour éviter que le sable et la poussière ne bouchent et n'altèrent la vitesse du vent.

7. La chambre d'essai de sable et de poussière peut-elle tester les niveaux de protection IP ?
Oui ! En ajustant la concentration de sable et de poussière ainsi que le temps de soufflage, elle peut vérifier si le produit répond aux normes IP5X (résistance à la poussière) ou IP6X (résistance totale à la poussière).

8. Quelles sont les exigences en matière de matériaux pour la chambre d'essai ?
La paroi intérieure doit être en acier inoxydable 304 ou recouverte d'un matériau anticorrosion pour assurer une résistance à l'usure et à la corrosion. La fenêtre d'observation doit être en verre trempé pour une observation en temps réel facile du processus de test.

9. La chambre d'essai de sable et de poussière nécessite-t-elle un contrôle de la température et de l'humidité ?
Certains modèles supportent un contrôle en liaison de la température et de l'humidité (par exemple haute température + sable et poussière), pour simuler des environnements plus sévères (comme des tempêtes de sable en haute température dans le désert), mais le modèle de base ne nécessite que des tests avec du sable et de la poussière sèche.

10. Comment juger la performance d'une chambre d'essai de sable et de poussière ?
Les indicateurs clés incluent l'uniformité de la concentration de sable et de poussière, la stabilité de la vitesse du vent, la performance d'étanchéité et la facilité d'utilisation. Il est recommandé de choisir un équipement conforme aux normes et offrant un bon service après-vente.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MessageMessage

Demandez un devis