Boden 1, Nr. 3, Shugang Avenue, Hongmei Town, Dongguan City, Guangdong Province, China

Hersteller von Umwelttestkammern seit 20 JahrenMehr als 3000 Kunden weltweit geliefert           E-Mail: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

DR-H508 Sandstaub-Testkammer

Das DERUI DR-H508-2 1000 L sand dust test chamber provides a 1000 × 1000 × 1000 mm stainless-steel workspace with dust recirculation, pneumatic vibration, timed dust heating and provision for specimen pressure connection. Confirm the selected procedure, dust medium and vacuum package before ordering.

Modell DR-H508-2
Innere Abmessungen 1000 × 1000 × 1000 mm (1,000 L)
Published Dust Loading 2 kg/m³
Test Functions Dust circulation, vibration, timed heating and test timing
Vacuum Package Connection components published; vacuum pump specified separately
Stromversorgung AC380 V ±10%, 50 Hz, three-phase five-wire
Sicher und zuverlässig
Hochwertig hergestellt
Qualitätssicherung
Anpassung
NachrichtWhatsApp
Hotline-Nummer 15580327593
  • Produktdetails
  • Technische Parameter
  • FAQ
  • Kontaktieren Sie uns
1 m³ Recirculating Sand and Dust Chamber

DR-H508-2 1000 L Sand Dust Test Chamber

A floor-standing 1,000 L configuration for enclosure sealing tests on automotive parts, electrical products, instruments and industrial housings. The chamber combines a stainless-steel workspace, dust recirculation, pneumatic vibration, dust heating and provision for specimen pressure connection.

Page role: this page describes the published 1,000 L DR-H508-2 hardware configuration. For method-led selection across different chamber sizes and enclosure categories, use the dust ingress test chamber configuration page.
Internal dimensionscURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Nominal workspace1,000 L
Published dust loading2 kg/m³
StromversorgungAC380 V ±10%, 50 Hz, three-phase five-wire

Where This 1,000 L Configuration Fits

Automotive assemblies

Headlamps, instrument housings, electrical covers, steering components, locks and seals that fit the 1 m³ workspace and required clearances.

Electrical enclosures

Control boxes, appliances, instruments and outdoor electronics evaluated for dust entry under a specified enclosure-protection procedure.

Production and design verification

Use repeatable timing, dust circulation and specimen connections for engineering validation, incoming checks or periodic quality control.

Published DR-H508-2 Specifications

Artikel Published value Technical-agreement check
Internal dimensions (D × W × H) cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Confirm usable clearance, shelves and specimen orientation.
External dimensions (D × W × H) 1480 × 1260 × 1980 mm Check doorway, transport route, service and cleaning clearance.
Metal mesh wire / nominal pitch 50 μm / 75 μm Confirm terminology and required sieve specification for the selected method.
Dust consumption 2 kg/m³ Treat as published loading, not continuously measured airborne concentration.
Vibration timer Up to 99 min 59 s Confirm cycle logic and interval setting.
Test timer Up to 99 h 59 min Confirm required duration, interruptions and accumulated-time handling.
Specimen power socket Dustproof AC220 V, 16 A Confirm specimen current, heat and destination socket arrangement.
Stromversorgung AC380 V ±10%, 50 Hz, three-phase five-wire Confirm destination voltage and protective device before production.

Construction and Control System

Assembly Published construction or function Warum es wichtig ist
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Powder-coated steel exterior; SUS stainless-steel mirror-finish interior Supports cleaning, durability and dust containment.
Door and observation Transparent glass observation door Allows visual checks without opening during the active test.
Dust circulation Geschlossener Legierung-Niedriggeräuschmotor, Mehrblatt-Zentrifugalventilator Blows settled dust into the workspace for recirculation.
Pneumatic vibration Vibration device and bottom dust-replacement arrangement Helps return accumulated powder to the circulation path.
Dust heating Stainless-steel mica-sheet heating sleeve with timed control Helps prevent moisture-related dust clumping; it is not specimen climate control.
Controller Touchscreen with PLC programme and working-time display Controls test sequence, timing and operating status.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Fixed casters at the chamber base Supports positioning while retaining stable placement.

Vacuum and Safety Configuration

Pressure connection components

The published package includes a pressure gauge, air filter, pressure-regulating tee and connecting pipe. Confirm range, accuracy, flow measurement and specimen connection.

Vacuum pump boundary

The current specification states that the vacuum pump is supplied separately and must be specified when ordering. Do not assume it is included.

Equipment protection

Published protections include leakage, short circuit, over-temperature, motor overheat, over-current, phase-loss and phase-sequence protection.

1000 L Sand Dust Chamber Reference Image

DR-H508 Sand-Testkammer

Reference image for the DR-H508 series. Verify the ordered 1000 × 1000 × 1000 mm workspace, controller, ports, vacuum components and destination power against the approved drawing.

Keep the Two Dust Pages Separate

Page Primary search intent Use it when
This 1000 L sand dust chamber page Specific DR-H508-2 model, 1 m³ dimensions, construction, timers and electrical configuration The specimen fits the published chamber and the buyer needs a concrete equipment specification.
Dust ingress test chamber page IP5X/IP6X method selection, enclosure category, pressure conditions and configurable chamber sizing The buyer is still determining the correct method and configuration.
Dedicated blowing sand/dust system MIL-STD-810 Method 510 profiles The requirement specifies controlled high airflow, particle feed and tailored blowing sand or dust conditions.
Wichtig: product naming alone does not make this cabinet a MIL-STD-810 blowing-sand system. Confirm the exact standard, revision, procedure, particle feed, airflow and environmental profile before making that claim.

Commissioning and Routine Control

Verify installation

Check floor loading, access clearance, protective earth, three-phase supply and ventilation.

Verify the test medium

Confirm dust specification, dry condition, sieve suitability, loading and reuse/replacement rule.

Verify specimen setup

Record orientation, seals, cable glands, powered state and any pressure connection.

Run the approved cycle

Set circulation, vibration, heating and test timers according to the selected procedure.

Recover and clean

Allow dust to settle, protect operators and avoid moving external powder into the enclosure during handling.

Inspect and document

Apply the agreed internal inspection, functional checks and acceptance criteria.

Factory Acceptance Checklist

Überprüfen Recommended verification
Dimensions and access Measure workspace, door opening and external envelope; verify shelves and caster arrangement.
Dust circuit Demonstrate fan, vibration, heating, recovery path and timer sequence.
Vacuum components Verify supplied parts, connection, pressure indication and ordered pump boundary.
Specimen power Confirm socket voltage/current, isolation and powered-load restrictions.
Sicherheit Test leakage, short-circuit, over-temperature, motor, over-current and phase protections.
Dokumentation Check manual, wiring diagram, inspection record, packing list and agreed calibration evidence.

Häufig gestellte Fragen

Is this page the same product as the dust ingress test chamber page?

They are related, but the page roles are different. This page presents the published 1,000 L DR-H508-2 configuration; the other page explains method-led IP5X/IP6X selection and custom sizing.

Is the vacuum pump included?

The current specification says it is supplied separately and must be specified when ordering. Confirm the pump, control range and flow requirements in the quotation.

Does 2 kg/m³ mean measured airborne dust concentration?

No. It is published as dust consumption/loading. Do not describe it as continuous concentration measurement unless the ordered system includes verified instrumentation.

Does the dust heating system control specimen temperature?

No. Its stated function is to reduce dust adhesion and clumping. It is not a temperature-conditioning system for the specimen.

Can it perform MIL-STD-810 blowing sand?

Not from the published configuration alone. Method 510 requires separate confirmation of particle feed, airflow, temperature and procedure-specific controls.

What must be confirmed before ordering?

Confirm specimen size and mass, standard, enclosure category, dust, pressure conditions, powered state, destination power, accessories, FAT and documentation.

Confirm the 1 m³ Configuration Against the Specimen

Send the enclosure drawing, required procedure, dust, pressure condition and powered state. DERUI can confirm whether the published DR-H508-2 configuration fits or a different chamber is required.

Request a DR-H508-2 Review

FacebookLinkedInXRedditWhatsApp
Artikel Details
Modell DR -H508-2
Innere Abmessungen (D×B×H) mm 1000×1000×1000
Äußere Abmessungen (D×B×H) mm 1480×1260×1980
Durchmesser des Metallgitternetzdrahts 50 μm
Nennabstand zwischen den Drähten 75 μm
Staubverbrauch 2 kg/m³
Vibrationszeit 99 Minuten und 59 Sekunden
Testzeit 99 Stunden und 59 Minuten
Testprobe Steckdose Staubdichte Steckdose, AC220V, 16A
Controller Touchscreen-Display gesteuert durch importiertes PLC-Programm, mit Anzeige von Arbeitszeit und anderen Informationen auf Chinesisch
Vakuumsystem Ausgestattet mit Manometer, Luftfilter, Druckregelungst-Stück, Verbindungsschlauch (Vakuumpumpe separat bereitzustellen, bitte bei Bestellung angeben)
Umluftventilator Geschlossener Legierung-Niedriggeräuschmotor, Mehrblatt-Zentrifugalventilator
Staubheizungssystem Edelstahl-Mika-Plattenheizmanschette
Netzspannung AC380V ± 10%, T3T, 50Hz, Dreiphasen-Fünf-Leiter-System
Sicherheitsvorkehrungen Leckageschutz, Kurzschlussschutz, Übertemperaturschutz, Motorkühlungsschutz, Überstromschutz

1. Was ist der Hauptzweck einer Sand- und Staubtestkammer?
Sie wird verwendet, um eine Sand- und Staubumgebung zu simulieren, um die Abdichtung, Verschleißfestigkeit und Zuverlässigkeit von Produkten unter Wind- und Sanderosion zu testen. Sie ist anwendbar in Branchen wie Automobil, Elektronik und Militär.

2. Welche Normen erfüllt die Sand- und Staubtestkammer?
Sie entspricht internationalen Normen wie GB/T 2423.37 (Sand- und Staubprüfung für elektrische und elektronische Produkte) und IEC 60068-2-68, um die Autorität der Testergebnisse zu gewährleisten.

3. Wie wird die Staubkonzentration in der Staubtestkammer kontrolliert?
Die Staubkonzentration kann präzise von 0,1 bis 5 g/m³ durch ein einstellbares Luftstromsystem und einen Präzisionsdurchflussmesser angepasst werden, um verschiedenen Testanforderungen gerecht zu werden.

4. Was ist der Windgeschwindigkeitsbereich der Testkammer?
Sie unterstützt in der Regel eine Windgeschwindigkeitsanpassung von 1 bis 10 m/s, um natürliche Wind- und Sandumgebungen zu simulieren. Einige High-End-Modelle können für höhere Windgeschwindigkeiten angepasst werden.

5. In welchen Branchen ist die Staubtestkammer anwendbar?
Sie wird häufig in den Bereichen Automobil (Filter, Lampen), Elektronik (Dichtungen, Außenanlagen), Militärindustrie (Schutzausrüstung), Luft- und Raumfahrt usw. eingesetzt.

6. Wie reinigt man die Sand- und Staubtestkammer?
Nach dem Test sollte die Ausrüstung ausgeschaltet werden. Warten Sie, bis Sand und Staub sich gesetzt haben, und reinigen Sie dann das Innere mit einem Staubsauger. Ersetzen Sie auch regelmäßig den Filter, um Verstopfungen durch Sand und Staub zu vermeiden, die die Windgeschwindigkeit beeinträchtigen könnten.

7. Kann die Sand- und Staubtestkammer IP-Schutzarten testen?
Ja! Durch Anpassung der Sand- und Staubkonzentration und Blaszeit kann überprüft werden, ob das Produkt den IP5X (staubdicht) oder IP6X (vollständig staubdicht) Standards entspricht.

8. Was sind die Materialanforderungen für die Testkammer?
Die Innenseite sollte aus 304 Edelstahl bestehen oder mit korrosionsbeständigem Material beschichtet sein, um Verschleiß- und Korrosionsbeständigkeit zu gewährleisten. Das Beobachtungsfenster sollte aus gehärtetem Glas bestehen, um eine einfache Echtzeitbeobachtung des Testprozesses zu ermöglichen.

9. Benötigt die Sand- und Staubtestkammer Temperatur- und Feuchtigkeitskontrolle?
Einige Modelle unterstützen eine gekoppelte Steuerung von Temperatur und Feuchtigkeit (wie Hochtemperatur + Sand und Staub), um anspruchsvollere Umgebungen zu simulieren (wie Wüsten-Hochtemperatursandstürme), aber das Basismodell erfordert nur Trockenstaub- und Sandtests.

10. Wie beurteilt man die Leistung einer Sand- und Staubtestkammer?
Die wichtigsten Indikatoren umfassen die Gleichmäßigkeit der Sand- und Staubkonzentration, die Stabilität der Windgeschwindigkeit, die Abdichtungsleistung und die Bedienfreundlichkeit. Es wird empfohlen, Geräte zu wählen, die den Standards entsprechen und einen guten Kundendienst bieten.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
NachrichtNachricht

Anfrage für ein Angebot