ห้องทดสอบกันน้ำ IPX7 & IPX8 พร้อมเครื่องทดสอบกันน้ำอย่างแม่นยำ

The DERUI DR-H504 IPX7 & IPX8 water immersion test chamber uses a closed SUS304 stainless-steel vessel with compressed-air pressure application to evaluate enclosure sealing under defined immersion conditions. Its Ø1000 × 1000 mm internal vessel and published pressure range up to 0.5 MPa support method-specific specimen and exposure planning.

รุ่น DR-H504
ประเภทการทดสอบ Pressure water immersion for IPX7/IPX8 applications
Internal vessel 1000 mm diameter × 1000 mm height
Published pressure Ambient to 0.5 MPa; measurement reference defined by the test plan
Sample handling Removable stainless-steel basket and graduated water-level indication
Before quotation Specify specimen, pressure/depth reference, duration, method and acceptance requirements
ปลอดภัยและเชื่อถือได้
คุณภาพดี
การรับประกันคุณภาพ
การปรับแต่ง
ข้อความWhatsApp
หมายเลขสายด่วน 15580327593
  • รายละเอียดสินค้า
  • พารามิเตอร์ทางเทคนิค
  • คำถามที่พบบ่อย
  • ติดต่อเรา
DR-H504 · Pressure water immersion

IPX7 & IPX8 Water Immersion Testing for Sealed Enclosures

Evaluate enclosure seals, cable entries and connectors under a defined water-immersion exposure. DERUI DR-H504 uses a closed stainless-steel vessel and compressed-air pressure application for laboratory immersion testing, with a published pressure range up to 0.5 MPa.

Ø1000 × 1000 mmInternal diameter × height
Up to 0.5 MPaPublished applied pressure
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limitsMethod-specific immersion applications

Review Your Immersion Test Requirements

A Pressure-Immersion System—not a Rain Spray Chamber

Find water-ingress weaknesses at the enclosure level

Use a defined immersion exposure to investigate sealing interfaces in electrical housings, outdoor sensors, connectors, lighting enclosures and other parts intended to operate in wet conditions. Focus on the complete assembly: gasket compression, cable glands, plugs, joints and mounting orientation can all affect the result.

DR-H504 applies pressure to water in a closed vessel rather than directing jets at the specimen. A removable stainless-steel basket supports loading, while a graduated water-level tube helps establish the fill condition. Pressure release and drainage support the unloading sequence.

Choose this arrangement when the accepted immersion procedure, specimen size and pressure requirement fit the vessel. For an open-tank depth requirement, confirm that the proposed setup meets the prescribed geometry before choosing pressure simulation.

DERUI DR-H504 IPX7 IPX8 pressure water immersion test chamber
DR-H504 water immersion test chamber.

Specify the Immersion Method Before the Pressure Setting

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits IPX7 temporary immersion IPX8 immersion
Exposure basis Prescribed temporary-immersion setup; IEC 60529 uses a 30-minute exposure Product-specific conditions agreed by the relevant parties, more severe than IPX7
Water coverage and depth Use the reference point and specimen-size rules of the adopted method; “1 m” alone is an incomplete setup instruction Define pressure or depth reference, orientation, water coverage and duration for the enclosure
Equipment fit Check vessel height, specimen mounting and whether the proposed test arrangement is accepted Check required pressure, duration, loading, water conditions and measurement tolerance
Result evaluation Inspect and evaluate harmful ingress according to the applicable requirements Apply the agreed ingress, functional and electrical acceptance criteria

IEC 60529 defines the enclosure IP-code framework. For road-vehicle electrical equipment, identify the required ISO 20653 procedure and any OEM requirements separately.

The equipment creates an exposure; it does not certify the product. Agree the standard edition, mounting, operating state, exposure and acceptance criteria before testing. An immersion rating does not automatically demonstrate resistance to spray or hot-water jets.

DR-H504 Technical Configuration

พารามิเตอร์ cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
รุ่น DR-H504
Test arrangement Closed-vessel water immersion with compressed-air pressure application
Internal vessel dimensions 1000 mm diameter × 1000 mm height; specimen capacity depends on basket, opening, water level and fixtures
Vessel material สแตนเลส SUS304
Published applied-pressure range Ambient to 0.5 MPa; specify gauge/absolute reference and sensor location in the technical agreement
Published depth-equivalent capability Approximately 50 m of water head through pressure application; not a 50 m tall tank or a universal IPX8 test condition
Exposure timing Adjustable test timer; required duration and timing format defined in the configuration proposal
Sample handling Removable stainless-steel basket
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Graduated water-level tube
Water and pressure handling Drainage and pressure-release functions
Published protection functions Pressure protection, overload protection, short-circuit protection, grounding and alarm indication

For formal testing, include pressure-measurement accuracy, calibration, required hold stability and the actual timing range in the acceptance specification. Operating range alone does not define vessel design pressure, proof-test pressure or regulatory approval.

Translate Depth into Pressure—and Check the Sample Fit

Pressure-equivalent depth is a calculation, not the physical tank height

For static water, pressure increases with depth according to p = ρgh. Using freshwater density of approximately 1000 kg/m³ and g = 9.81 m/s², a 10 m water head is approximately 98 kPa (0.098 MPa); a 50 m head is approximately 491 kPa (0.491 MPa). These are illustrative pressure differences above the free surface, not universal test setpoints.

Use the specimen reference point. In a pressurized vessel, pressure at the specimen includes applied surface pressure and the water head above that point. Agree the gauge/absolute convention, sensor location and depth reference so the report describes the actual exposure.

Loading envelope

Check the access opening, basket and fixture dimensions—not only the cylinder diameter. Leave room for the prescribed orientation and complete water coverage without contacting seals against the vessel.

Displacement and buoyancy

A submerged assembly displaces water and may float or rotate. Define restraints that hold it safely without compressing a gasket, blocking an ingress path or changing the required exposure.

Temperature and operation

Record specimen and water conditions when required by the procedure. If energized testing is needed, specify an engineered feedthrough and electrical safety arrangement rather than routing cables through the lid seal.

Provide the complete assembly drawing, not only the housing dimensions. Include protruding connectors, cable bend space, mounting brackets, the fixture, sample mass and the number of parts to test at once.

Build a Repeatable Test and a Clear Acceptance Plan

1 · Prepare and mount

Record specimen identity, sealing configuration, conditioning, orientation and operating state. Set the specified water level and verify that the fixture does not shield or distort critical interfaces.

2 · Apply and record

Follow the approved pressure and timing procedure. Record the actual pressure reference, exposure duration, water conditions and any interruptions. Specify manual recording or an agreed acquisition system.

3 · Release and evaluate

Use the documented depressurization and drainage sequence. Follow the prescribed external drying, opening and inspection procedure so handling water is not confused with test ingress.

Agree factory acceptance around your operating point

Acceptance item Evidence to include in the purchase specification
Vessel and protection Applicable destination requirements, design documentation, pressure-test evidence, relief/protection settings and closure checks
Pressure exposure Calibrated measurement reference, agreed operating point, hold stability, duration and recording method
Sample loading Basket and fixture fit, mass capacity, submerged orientation, water level and safe loading/unloading
Utilities and operation Compressed-air requirements, water supply/drain, electrical supply, operator instructions and maintenance access
Result workflow Sample identification, exposure record and separate ingress/functional/electrical checks required by the method
Pressurized equipment requires a defined safe operating procedure. Compressed air stores energy. Operate within the approved limits and follow the supplied isolation, depressurization and zero-pressure verification procedure before opening. Never bypass protective devices. Include the destination’s pressure-equipment inspection requirements in the procurement review; see HSE pressure-system guidance for the general hazard.

Need a different water exposure? Review the IPX5/IPX6 water-jet chamber for nozzle testing, the IPX9K hot-water jet chamber for severe wash-down procedures, or the rain and water-ingress equipment category for broader selection.

IPX7 / IPX8 Water Immersion Chamber FAQ

What is the difference between IPX7 and IPX8 immersion testing?

IPX7 addresses temporary immersion under the prescribed setup. IPX8 addresses immersion under conditions specified for the product and agreed by the relevant parties, more severe than IPX7. Do not use one default pressure and duration for every IPX8 enclosure.

Can DR-H504 be used for both IPX7 and IPX8?

It is offered for IPX7/IPX8 immersion applications. The required specimen positioning, water coverage, exposure conditions and accepted test arrangement must fit the selected method. A pressure vessel does not automatically replace a required open-tank procedure. Send the complete test plan for a configuration review.

Does the chamber need a 50 m deep tank?

No. The approximately 50 m figure describes pressure-equivalent water head produced by pressure application. The listed vessel is 1000 mm in diameter and 1000 mm high. Confirm pressure at the specimen reference point, including water head, rather than relying only on a depth label.

How large a specimen can be tested?

The vessel dimensions are not a maximum specimen rating. Basket clearance, access opening, submerged orientation, displacement, buoyancy and fixture space determine fit. Send a specimen drawing, mass and quantity so the loading arrangement can be reviewed.

Are heated water, powered specimens and automatic data export included?

These functions are not part of the configuration listed here. Include any water-temperature control, electrical feedthrough, monitoring or record-export requirement in your request so the proposal identifies the supplied functions explicitly.

Does passing immersion testing also prove resistance to water jets?

No. Immersion, spraying and high-pressure hot-water jets are different exposures. If the product needs IPX5/IPX6 or IPX9/IPX9K as well, include those methods separately. Product approval also depends on the required inspection and acceptance criteria, not the chamber label alone.

Request a DR-H504 Immersion Test Proposal

Send the Enclosure Drawing and Required Exposure

Turn your waterproofing requirement into a defined vessel, loading and acceptance specification. Request a DR-H504 proposal around the pressure and specimen arrangement your laboratory actually needs.

Include: standard edition and clause; IPX7 or IPX8 conditions; target pressure/depth reference and duration; specimen dimensions, mass and quantity; submerged orientation and fixtures; water-temperature requirements; powered state; pressure recording; site utilities and destination.

Request an Immersion Testing Proposal

เฟซบุ๊กLinkedInXRedditWhatsApp

รายการ

สเปค

ขนาดภายใน

เส้นผ่านศูนย์กลาง 1000 * ความสูง 1000 มม.

วัสดุห้อง

SUS#304 ความหนา 2 มม.

ความลึกของน้ำ

จำลองความลึก 50 เมตรด้วยเครื่องอัดอากาศ

แรงดันน้ำ

แรงดันจากอากาศถึง 0.5MPa ความแม่นยำของเกจวัดแรงดัน 0.25 องศา

นาฬิกาจับเวลา

0 ~ 99 นาที, 99 วินาที

อุปกรณ์ยกตัวอย่าง

ตะกร้าสแตนเลสพกพา

แสดงระดับน้ำ

ท่อส่งน้ำพร้อมมาตราส่วน

อุปกรณ์ป้องกัน

อุปกรณ์ป้องกันแรงดันและกันระเบิด, อุปกรณ์ระบายน้ำและปล่อยแรงดัน

การป้องกันความปลอดภัย

การป้องกันไฟฟ้าลัดวงจร, การป้องกันเกินพลังงาน, การป้องกันการต่อสายดิน, การแสดงสัญญาณเตือน

ห้องทดสอบการจุ่มน้ำ IPX7 8 ใช้ทำอะไร?

ออกแบบมาเพื่อทดสอบความสามารถกันน้ำของอุปกรณ์อิเล็กทรอนิกส์โดยจำลองการจุ่มน้ำ ซึ่งช่วยยืนยันว่าสินค้าของคุณเป็นไปตามมาตรฐาน IPX7 หรือ IPX8 สำหรับการป้องกันน้ำเข้า.

ห้องนี้สามารถทดสอบมาตรฐาน IPX7 และ IPX8 ได้หรือไม่?

ได้ สนับสนุนการทดสอบทั้ง IPX7 (จุ่มน้ำสูงสุด 1 เมตร เป็นเวลา 30 นาที) และ IPX8 (จุ่มน้ำลึกกว่า 1 เมตร เป็นเวลานาน) เพื่อความแน่ใจในการรับรองกันน้ำอย่างละเอียด.

อุปกรณ์นี้เหมาะสำหรับการทดสอบอุปกรณ์อิเล็กทรอนิกส์และกล่องบรรจุภัณฑ์หรือไม่?

แน่นอน ห้องนี้เหมาะสำหรับการทดสอบกันน้ำของอิเล็กทรอนิกส์ การตรวจสอบความสมบูรณ์ของซีล และการทดสอบความน่าเชื่อถือในห้องปฏิบัติการของกล่องและเคสอิเล็กทรอนิกส์.

ห้องนี้เป็นไปตามมาตรฐาน IEC 60529 หรือไม่?

ใช่ การทดสอบการกันน้ำที่ดำเนินการเป็นไปตามข้อกำหนด IEC 60529 ทำให้เชื่อถือได้สำหรับการรับรองกันน้ำ.

ความลึกสูงสุดที่ห้องนี้สามารถจุ่มน้ำได้เท่าไร?

ห้องทดสอบรองรับความลึกในการจุ่มน้ำที่ปรับได้ โดยทั่วไปสูงสุดหลายเมตรขึ้นอยู่กับรุ่น เพื่อรองรับความต้องการทดสอบที่แตกต่างกัน.

การใช้งานห้องทดสอบกันน้ำ Derui เป็นเรื่องง่ายเพียงใด?

มาพร้อมกับอินเทอร์เฟซที่ใช้งานง่าย พร้อมการตั้งค่าที่ปรับแต่งได้สำหรับความลึกในการทดสอบ ระยะเวลา และอุณหภูมิน้ำ ทำให้ใช้งานได้ง่ายในทุกสภาพแวดล้อมห้องปฏิบัติการ.

ฉันสามารถปรับแต่งพารามิเตอร์การทดสอบให้ตรงกับความต้องการของผลิตภัณฑ์เฉพาะได้หรือไม่?

ได้ คุณสามารถตั้งค่าระยะเวลาการทดสอบ ความลึกในการจุ่มน้ำ และเงื่อนไขอื่น ๆ ให้ตรงกับเกณฑ์สมรรถนะกันน้ำที่ต้องการ.

ต้องการการบำรุงรักษาหรือไม่สำหรับห้องทดสอบกันน้ำ?

ต้องการการบำรุงรักษาน้อยที่สุด คำแนะนำให้ทำความสะอาดและสอบเทียบเป็นประจำเพื่อให้เครื่องมือมีความแม่นยำและเชื่อถือได้.

ใครควรพิจารณาใช้ห้องทดสอบกันน้ำนี้?

บริษัทที่ผลิตหรือทดสอบอิเล็กทรอนิกส์ กล่องบรรจุภัณฑ์ และผลิตภัณฑ์อื่น ๆ ที่ต้องการการรับรอง IPX7 หรือ IPX8 จะได้รับประโยชน์จากห้องนี้.

ฉันจะสามารถขอรับการสนับสนุนหรือบริการสำหรับอุปกรณ์ทดสอบกันน้ำ Derui ได้ที่ไหน?

Derui มีบริการสนับสนุนลูกค้าและตัวเลือกบริการในประเทศไทยเพื่อให้แน่ใจว่าอุปกรณ์ทดสอบของคุณทำงานได้อย่างราบรื่นและมีประสิทธิภาพ.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
ข้อความข้อความ

ขอใบเสนอราคา