IPX7 ve IPX8 Suya Daldırma Test Odası Hassas Su Geçirmezlik Test Cihazı

The DERUI DR-H504 IPX7 & IPX8 water immersion test chamber uses a closed SUS304 stainless-steel vessel with compressed-air pressure application to evaluate enclosure sealing under defined immersion conditions. Its Ø1000 × 1000 mm internal vessel and published pressure range up to 0.5 MPa support method-specific specimen and exposure planning.

Model DR-H504
Test türü Pressure water immersion for IPX7/IPX8 applications
Internal vessel 1000 mm diameter × 1000 mm height
Published pressure Ambient to 0.5 MPa; measurement reference defined by the test plan
Sample handling Removable stainless-steel basket and graduated water-level indication
Before quotation Specify specimen, pressure/depth reference, duration, method and acceptance requirements
Güvenli ve güvenilir
İyi yapılmış
Kalite güvencesi
Özelleştirme
MesajWhatsApp
Hattın numarası 15580327593
  • Ürün Detayları
  • Teknik parametreler
  • SSS
  • Bizimle iletişime geçin
DR-H504 · Pressure water immersion

IPX7 & IPX8 Water Immersion Testing for Sealed Enclosures

Evaluate enclosure seals, cable entries and connectors under a defined water-immersion exposure. DERUI DR-H504 uses a closed stainless-steel vessel and compressed-air pressure application for laboratory immersion testing, with a published pressure range up to 0.5 MPa.

Ø1000 × 1000 mmInternal diameter × height
Up to 0.5 MPaPublished applied pressure
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limitsMethod-specific immersion applications

Review Your Immersion Test Requirements

A Pressure-Immersion System—not a Rain Spray Chamber

Find water-ingress weaknesses at the enclosure level

Use a defined immersion exposure to investigate sealing interfaces in electrical housings, outdoor sensors, connectors, lighting enclosures and other parts intended to operate in wet conditions. Focus on the complete assembly: gasket compression, cable glands, plugs, joints and mounting orientation can all affect the result.

DR-H504 applies pressure to water in a closed vessel rather than directing jets at the specimen. A removable stainless-steel basket supports loading, while a graduated water-level tube helps establish the fill condition. Pressure release and drainage support the unloading sequence.

Choose this arrangement when the accepted immersion procedure, specimen size and pressure requirement fit the vessel. For an open-tank depth requirement, confirm that the proposed setup meets the prescribed geometry before choosing pressure simulation.

DERUI DR-H504 IPX7 IPX8 pressure water immersion test chamber
DR-H504 water immersion test chamber.

Specify the Immersion Method Before the Pressure Setting

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits IPX7 temporary immersion IPX8 immersion
Exposure basis Prescribed temporary-immersion setup; IEC 60529 uses a 30-minute exposure Product-specific conditions agreed by the relevant parties, more severe than IPX7
Water coverage and depth Use the reference point and specimen-size rules of the adopted method; “1 m” alone is an incomplete setup instruction Define pressure or depth reference, orientation, water coverage and duration for the enclosure
Equipment fit Check vessel height, specimen mounting and whether the proposed test arrangement is accepted Check required pressure, duration, loading, water conditions and measurement tolerance
Result evaluation Inspect and evaluate harmful ingress according to the applicable requirements Apply the agreed ingress, functional and electrical acceptance criteria

IEC 60529 defines the enclosure IP-code framework. For road-vehicle electrical equipment, identify the required ISO 20653 procedure and any OEM requirements separately.

The equipment creates an exposure; it does not certify the product. Agree the standard edition, mounting, operating state, exposure and acceptance criteria before testing. An immersion rating does not automatically demonstrate resistance to spray or hot-water jets.

DR-H504 Technical Configuration

Parametre cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits
Model DR-H504
Test arrangement Closed-vessel water immersion with compressed-air pressure application
Internal vessel dimensions 1000 mm diameter × 1000 mm height; specimen capacity depends on basket, opening, water level and fixtures
Vessel material SUS304 paslanmaz çelik
Published applied-pressure range Ambient to 0.5 MPa; specify gauge/absolute reference and sensor location in the technical agreement
Published depth-equivalent capability Approximately 50 m of water head through pressure application; not a 50 m tall tank or a universal IPX8 test condition
Exposure timing Adjustable test timer; required duration and timing format defined in the configuration proposal
Sample handling Removable stainless-steel basket
Water-level indication Graduated water-level tube
Water and pressure handling Drainage and pressure-release functions
Published protection functions Pressure protection, overload protection, short-circuit protection, grounding and alarm indication

For formal testing, include pressure-measurement accuracy, calibration, required hold stability and the actual timing range in the acceptance specification. Operating range alone does not define vessel design pressure, proof-test pressure or regulatory approval.

Translate Depth into Pressure—and Check the Sample Fit

Pressure-equivalent depth is a calculation, not the physical tank height

For static water, pressure increases with depth according to p = ρgh. Using freshwater density of approximately 1000 kg/m³ and g = 9.81 m/s², a 10 m water head is approximately 98 kPa (0.098 MPa); a 50 m head is approximately 491 kPa (0.491 MPa). These are illustrative pressure differences above the free surface, not universal test setpoints.

Use the specimen reference point. In a pressurized vessel, pressure at the specimen includes applied surface pressure and the water head above that point. Agree the gauge/absolute convention, sensor location and depth reference so the report describes the actual exposure.

Loading envelope

Check the access opening, basket and fixture dimensions—not only the cylinder diameter. Leave room for the prescribed orientation and complete water coverage without contacting seals against the vessel.

Displacement and buoyancy

A submerged assembly displaces water and may float or rotate. Define restraints that hold it safely without compressing a gasket, blocking an ingress path or changing the required exposure.

Temperature and operation

Record specimen and water conditions when required by the procedure. If energized testing is needed, specify an engineered feedthrough and electrical safety arrangement rather than routing cables through the lid seal.

Provide the complete assembly drawing, not only the housing dimensions. Include protruding connectors, cable bend space, mounting brackets, the fixture, sample mass and the number of parts to test at once.

Build a Repeatable Test and a Clear Acceptance Plan

1 · Prepare and mount

Record specimen identity, sealing configuration, conditioning, orientation and operating state. Set the specified water level and verify that the fixture does not shield or distort critical interfaces.

2 · Apply and record

Follow the approved pressure and timing procedure. Record the actual pressure reference, exposure duration, water conditions and any interruptions. Specify manual recording or an agreed acquisition system.

3 · Release and evaluate

Use the documented depressurization and drainage sequence. Follow the prescribed external drying, opening and inspection procedure so handling water is not confused with test ingress.

Agree factory acceptance around your operating point

Acceptance item Evidence to include in the purchase specification
Vessel and protection Applicable destination requirements, design documentation, pressure-test evidence, relief/protection settings and closure checks
Pressure exposure Calibrated measurement reference, agreed operating point, hold stability, duration and recording method
Sample loading Basket and fixture fit, mass capacity, submerged orientation, water level and safe loading/unloading
Utilities and operation Compressed-air requirements, water supply/drain, electrical supply, operator instructions and maintenance access
Result workflow Sample identification, exposure record and separate ingress/functional/electrical checks required by the method
Pressurized equipment requires a defined safe operating procedure. Compressed air stores energy. Operate within the approved limits and follow the supplied isolation, depressurization and zero-pressure verification procedure before opening. Never bypass protective devices. Include the destination’s pressure-equipment inspection requirements in the procurement review; see HSE pressure-system guidance for the general hazard.

Need a different water exposure? Review the IPX5/IPX6 water-jet chamber for nozzle testing, the IPX9K hot-water jet chamber for severe wash-down procedures, or the rain and water-ingress equipment category for broader selection.

IPX7 / IPX8 Water Immersion Chamber FAQ

What is the difference between IPX7 and IPX8 immersion testing?

IPX7 addresses temporary immersion under the prescribed setup. IPX8 addresses immersion under conditions specified for the product and agreed by the relevant parties, more severe than IPX7. Do not use one default pressure and duration for every IPX8 enclosure.

Can DR-H504 be used for both IPX7 and IPX8?

It is offered for IPX7/IPX8 immersion applications. The required specimen positioning, water coverage, exposure conditions and accepted test arrangement must fit the selected method. A pressure vessel does not automatically replace a required open-tank procedure. Send the complete test plan for a configuration review.

Does the chamber need a 50 m deep tank?

No. The approximately 50 m figure describes pressure-equivalent water head produced by pressure application. The listed vessel is 1000 mm in diameter and 1000 mm high. Confirm pressure at the specimen reference point, including water head, rather than relying only on a depth label.

How large a specimen can be tested?

The vessel dimensions are not a maximum specimen rating. Basket clearance, access opening, submerged orientation, displacement, buoyancy and fixture space determine fit. Send a specimen drawing, mass and quantity so the loading arrangement can be reviewed.

Are heated water, powered specimens and automatic data export included?

These functions are not part of the configuration listed here. Include any water-temperature control, electrical feedthrough, monitoring or record-export requirement in your request so the proposal identifies the supplied functions explicitly.

Does passing immersion testing also prove resistance to water jets?

No. Immersion, spraying and high-pressure hot-water jets are different exposures. If the product needs IPX5/IPX6 or IPX9/IPX9K as well, include those methods separately. Product approval also depends on the required inspection and acceptance criteria, not the chamber label alone.

Request a DR-H504 Immersion Test Proposal

Send the Enclosure Drawing and Required Exposure

Turn your waterproofing requirement into a defined vessel, loading and acceptance specification. Request a DR-H504 proposal around the pressure and specimen arrangement your laboratory actually needs.

Include: standard edition and clause; IPX7 or IPX8 conditions; target pressure/depth reference and duration; specimen dimensions, mass and quantity; submerged orientation and fixtures; water-temperature requirements; powered state; pressure recording; site utilities and destination.

Request an Immersion Testing Proposal

FacebookLinkedInXRedditWhatsApp

Ürün

Özellikler

İç boyut

Çap 1000 * yükseklik 1000mm

Oda malzemesi

SUS#304, kalınlık 2mm

Su derinliği

Hava kompresörü ile 50m derinliği simüle et

Su basıncı

Ortam 0.5MPa'ya kadar, basınç göstergesi doğruluğu 0.25 derece

Zamanlayıcı

0 ~ 99dk, 99sn

Numune kaldırma cihazı

Taşınabilir paslanmaz çelik sepet

Su seviyesi göstergesi

Ölçekli su borusu

Koruma cihazı

Basınç koruma ve patlamaya karşı koruma cihazı, su tahliye ve basınç serbest bırakma cihazı

Güvenlik koruması

Güç aşırı yük koruması, kısa devre koruması, topraklama koruması, alarm göstergesi

IPX7 ve IPX8 Suya Daldırma Test Odası ne için kullanılır?

Elektronik cihazların su geçirmezlik performansını suya daldırma simüle ederek test etmek için tasarlanmıştır. Bu, ürününüzün IPX7 veya IPX8 su geçirmezlik standartlarına uyup uymadığını doğrulamaya yardımcı olur.

Bu oda hem IPX7 hem de IPX8 derecelendirmelerini test edebilir mi?

Evet. Hem IPX7 (30 dakika boyunca 1 metreye kadar daldırma) hem de IPX8 (daha uzun süreler için 1 metreden fazla daldırma) testlerini destekler, böylece kapsamlı su geçirmezlik sertifikası sağlar.

Bu ekipman elektronik cihazlar ve muhafazalar için test yapmaya uygun mu?

Kesinlikle. Oda, elektroniklerin su geçirmezlik testleri, sızdırmazlık bütünlüğü kontrolleri ve elektronik muhafazalar ve gövdeler üzerinde laboratuvar güvenilirlik testleri için idealdir.

Oda IEC 60529 standartlarına uygun mu?

Evet. Gerçekleştirilen su sızdırmazlık testleri IEC 60529 gereksinimlerini karşılar ve su geçirmezlik sertifikası için güvenilirdir.

Odanın en fazla daldırma derinliği nedir?

Oda, farklı test ihtiyaçlarına uyacak şekilde genellikle birkaç metreye kadar ayarlanabilir daldırma derinliklerini destekler, modeline bağlı olarak.

Derui su geçirmez test odasını kullanmak ne kadar kolay?

Test derinliği, süre ve su sıcaklığı gibi özelleştirilebilir ayarlarla kullanıcı dostu bir arayüze sahiptir, böylece herhangi bir laboratuvar ortamında kullanımı kolaydır.

Belirli ürün gereksinimleri için test parametrelerini özelleştirebilir miyim?

Evet. Test süresi, daldırma derinliği ve diğer koşulları tam su geçirmezlik performans kriterlerine uygun şekilde ayarlayabilirsiniz.

Su geçirmez test odası bakım gerektiriyor mu?

Minimal bakım gereklidir. Cihazın doğru ve güvenilir kalması için düzenli temizlik ve kalibrasyon önerilir.

Bu su geçirmez test odasını kimler kullanmalı?

Elektronik, muhafaza ve diğer ürünleri üreten veya test eden şirketler, IPX7 veya IPX8 sertifikası gerektiren ürünler için bu odadan faydalanacaktır.

Derui su geçirmez test ekipmanına destek veya servis alabileceğim yer neresi?

Derui, test ekipmanlarınızın sorunsuz ve verimli çalışmasını sağlamak için Türkiye'de müşteri desteği ve servis seçenekleri sunar.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MesajMesaj

Teklif Talep Edin