Этаж 1, д. 3, проспект Шуган, город Хунмэй, город Дунгуань, провинция Гуандун, Китай

Производитель климатических камер для испытаний окружающей среды более 20 летБолее 3000 заказов клиентов по всему миру           Электронная почта: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

DR-H304-B Walk-In Salt Spray Test Room

The DERUI DR-H304-B walk-in salt spray test room is configured for oversized components and assemblies that need controlled salt-fog exposure with practical loading access. Room dimensions, method capability and utilities are engineered around the approved test plan.

Модель DR-H304-B
Equipment type Custom walk-in salt spray test room
Test focus Large components, coating panels and assembled products
Methods NSS; AASS/CASS only with the specified configuration
Room sizing Set by specimen, trolley, operator access and fog-collector clearances
Before quotation Provide specimen drawing, method, loading plan and site utilities
Безопасно и надежно
качественно изготовлено
Гарантия качества
кастомизация
СообщениеWhatsApp
Номер горячей линии 15580327593
  • Детали продукта
  • Технические параметры
  • Часто задаваемые вопросы
  • Свяжитесь с нами
DR-H304-B · Large-Component Corrosion Testing

Walk-In Salt Spray Test Room

When a coating panel, fabricated assembly or full-size component will not fit a conventional salt spray cabinet, a walk-in test room provides the access and loading space needed to position the specimen without crowding the fog collectors or nozzle zone.

DERUI configures the room envelope, access door, racks, fog-generation system and site utilities around the largest test article and the selected corrosion method.

What a Larger Test Space Solves

Oversize components

Plan clearance for body panels, enclosures, frames or long coated parts that cannot be mounted correctly in a bench cabinet.

Unobstructed fog exposure

Keep specimens clear of walls, nozzles and each other so runoff and spray shadowing do not distort results.

Repeatable batch loading

Design racks or a loading fixture around the actual part geometry, collection points and operator access.

Size the usable workspace, not just the nominal liters. Provide the largest specimen drawing, loaded orientation, quantity, fixture and door-clearance requirements.

Specify the Room Around the Test Article

Design item Information needed What the approved drawing should show
Internal room envelope Largest specimen and loaded fixture dimensions Usable length, width, clear height and service clearances
Access Operator and trolley movement; part handling method Door clear opening, threshold, aisle and escape arrangement
Fog collection Selected method and usable test zone Collector locations and acceptance measurement plan
Температура Required setpoint, tolerance and loaded condition Sensor layout and temperature-verification points
Solution system Test duration and refill interval Tank capacity, low-level protection and pipe materials
Коммунальные услуги Site power, air, water, exhaust and drain Connection schedule, installed load and service access
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Test modes, data and alarms Controller functions, records and safety interlocks

Large Salt Spray Chamber Photo

DERUI large salt spray chamber for oversized corrosion test specimens

Method First: NSS, AASS and CASS Are Not the Same

ASTM B117 describes operation of a continuous salt-fog environment; ISO 9227 covers NSS, AASS and CASS apparatus and procedures. The product or customer specification determines the exposure duration and pass/fail criteria. Confirm the adopted edition and method before selecting wetted materials and solution plumbing.

Method cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Equipment implication
NSS Neutral salt spray for metals and protected/coated surfaces Control the specified solution, chamber conditions and collected fog.
AASS Acetic-acid salt spray for selected decorative coatings Check acid compatibility, pH control and cleaning procedure.
CASS Copper-accelerated acid salt spray for selected plated finishes Check higher-temperature capability, copper-bearing solution handling and contamination control.
Cyclic corrosion Alternating wet, fog and/or dry stages under a separate method Requires a verified cyclic system; a controller program alone does not establish capability.

For smaller continuous-fog specimens, review the standard salt spray corrosion chamber. For programmable wet/dry methods, evaluate a dedicated cyclic salt spray chamber.

Five Design Decisions That Control Test Quality

Loading envelope

Define the largest part, handling method, fixture weight and clearance from walls and collectors.

Fog distribution

Specify collector positions across the usable space and acceptance limits under representative loading.

Solution handling

Match tank capacity, refill logic, water quality, pH checks and wetted materials to the test duration.

Room utilities

Plan power, compressed air, exhaust, drainage, floor loading and a route for bringing the specimen into the test area.

Records

Define which temperatures and alarms are logged automatically and which fog/pH readings remain operator measurements.

Maintenance access

Leave safe access to nozzles, collectors, saturator, seals, tank and drain for cleaning and calibration.

Acceptance Test: Prove Performance Across the Usable Space

Before shipment, align the factory acceptance test with the specimen drawing and the agreed method. A practical FAT should cover:

Проверить Evidence to keep
Dimensional fit As-built internal and door measurements; rack and specimen loading drawing
Контроль температуры Recorded sensor positions, setpoint, stabilization and deviation
Fog collection Collector layout and measured deposition at defined positions
Solution/air system Tank level protection, air regulation, nozzle operation and refill sequence
Safety and records Low-water/over-temperature responses, alarms and required report export

A chamber's volume or number of atomizers does not establish uniform exposure. Use the witnessed collection results for the approved loading zone.

Installation and Operating Scope

A walk-in corrosion room needs more than floor area. Before order, confirm floor load, personnel and trolley access, electrical supply, clean compressed air, make-up water, exhaust discharge and corrosion-resistant drainage. Keep salt-laden exhaust away from building HVAC and sensitive equipment; handle acidic or copper-containing waste according to the selected method and local site rules.

The approved room drawing should show clear internal height, door opening, operator route, emergency access, loading fixtures and safe maintenance access.

Часто задаваемые вопросы

How do I size a walk-in salt spray test room?

Start with the largest loaded specimen, trolley or fixture, operator access and required fog-collector clearance. Room volume alone does not establish usable capacity.

Can the room test a 2 m part?

Fit depends on the door opening, orientation, rack, collector positions and required clearances. Send a drawing of the complete loaded part.

Does ASTM B117 set the product's pass/fail hours?

No. ASTM B117 addresses the salt-fog apparatus and operating conditions. The product or customer specification defines exposure time and acceptance criteria.

Can the room run CASS or cyclic corrosion?

Only if the ordered materials, temperature, solution system and controls are engineered and verified for the exact procedure. Continuous NSS capability alone does not establish either mode.

What should be included in the RFQ?

Send the test method and edition, specimen drawing, quantity, fixture, exposure profile, site utilities, data requirements and acceptance points.

Size the Room Around Your Largest Test Article

Share the specimen drawing, selected method, loading arrangement and site utilities. DERUI can prepare a walk-in room configuration and measurable FAT scope.

Request a Walk-In Salt Spray Room Review

FacebookLinkedInXRedditWhatsApp

DR-H304-B Project Specification

The walk-in room is specified from the test article and laboratory layout. Record the approved values below in the quotation and as-built drawing.

Параметр Required definition
Internal room dimensions Approved clear length × width × height and usable test zone
Door and personnel access Clear opening, threshold, operator route and emergency access
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Trolley/rack size, rated load and specimen orientation
Method and conditions Adopted standard edition and selected NSS/AASS/CASS procedure
Fog distribution Collector positions and deposition acceptance under defined loading
Температура Setpoint, tolerance, sensor map and loaded verification
Solution system Tank capacity, refill, pH checks, level protection and wetted materials
Коммунальные услуги Installed power, compressed air, water, exhaust and drainage
Records and FAT Logged channels, alarms, export format and witnessed acceptance plan

1. Какая цена большой камеры для соляного тумана?
Цены варьируются в зависимости от размера, функций и автоматизации. Свяжитесь с поставщиками для получения предложений, соответствующих стандартам ASTM B117, ISO 9227 и вашим конкретным требованиям к испытаниям.

2. Как работает большая камера для соляного тумана?
Она имитирует коррозионные среды, распыляя соляной раствор в виде мелкого тумана внутри контролируемой камеры, ускоряя коррозию образцов для оценки долговечности материалов и качества покрытий.

3. Для чего используется большая камера для соляного тумана?
Используется для испытаний на коррозию в автомобильной, аэрокосмической и покрытийной промышленности. Оценивает стойкость материалов, качество покрытий и соответствие международным стандартам, таким как ASTM B117.

4. Как обслуживать большую камеру для соляного тумана?
Регулярно очищайте камеру, заменяйте форсунки, проверяйте уровни соляного раствора и обеспечивайте правильную герметизацию. Следуйте рекомендациям производителя для поддержания точности и продления срока службы оборудования.

5. Каковы технические характеристики большой камеры для соляного тумана?
Ключевые параметры включают объем камеры (например, 1000 л), диапазон температур, контроль pH, соответствие стандарту ASTM B117 и возможность циклических или непрерывных испытаний.

6. Где купить большую камеру для соляного тумана?
Приобретайте у сертифицированных поставщиков, таких как LabTech, Qualitest или напрямую у производителей. Убедитесь, что они предлагают установку, калибровку и сервисную поддержку в вашем регионе.

7. Сколько длится тест на соляной туман?
Продолжительность теста варьируется от 24 до более 1000 часов, в зависимости от стандартов материалов и требований к коррозионной стойкости. Обычно это 96, 240 или 500 часов.

8. В чем разница между тестами на соляной туман и циклическими коррозионными испытаниями?
Соляной туман — это непрерывное воздействие тумана. Циклические испытания чередуют соляной туман, влажность и фазы сушки, обеспечивая более реалистичное моделирование коррозии в суровых условиях.

9. Можно ли настроить большую камеру для соляного тумана?
Да. Варианты настройки включают расширение размеров, программирование циклических испытаний, дополнительные датчики и совместимость с конкретными стандартами, такими как GM9540P или Ford BI 103-01.

10. Как откалибровать большую камеру для испытания на соляной туман?
Калибруйте с помощью pH-метров, термометров и сборщиков тумана. Следуйте руководству ASTM B117 для обеспечения постоянной плотности тумана, температуры и концентрации раствора.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
СообщениеСообщение

Запросить коммерческое предложение