270L Salt Spray Corrosion Chamber DR-H304-270

The DERUI DR-H304-270 270L salt spray corrosion chamber provides a 900 × 600 × 500 mm enclosure for laboratory specimens and smaller component sets. Continuous or periodic spray operation supports a defined exposure programme, with loading and utilities selected around your samples.

Модель DR-H304-270 / 90-type cabinet
Workspace (W × D × H) 900 × 600 × 500 mm; 270 L nominal volume
External size (W × D × H) 1460 × 960 × 1150 mm
Spray operation Continuous or periodic spray
Selection focus Laboratory specimens and small-batch corrosion checks
Безопасно и надежно
качественно изготовлено
Гарантия качества
кастомизация
СообщениеWhatsApp
Номер горячей линии 15580327593
  • Детали продукта
  • Технические параметры
  • Часто задаваемые вопросы
  • Свяжитесь с нами

90-TYPE CABINET · 270 L CAPACITY · LABORATORY CORROSION CHECKS

Size Your Salt Spray Setup Around the Samples You Actually Test

The DERUI DR-H304-270 salt spray corrosion chamber provides a 900 × 600 × 500 mm enclosure for laboratory specimens, small component sets and coated coupons. This 90-type model has 270 L nominal volume, with continuous or periodic spray operation for a defined corrosion-test programme.

900 mm internal width

Check the complete specimen and fixture envelope.

270 L nominal capacity

Choose the layout before assigning a sample count.

1460 × 960 mm footprint

Allow additional cover movement and service access.

For a laboratory handling smaller runs, start with the required exposure and specimen layout. Request a DR-H304-270 proposal that includes mounting, utilities and the records your quality system needs.

When a 270L Cabinet Is the Right Starting Point

A laboratory does not always need a large batch cabinet. If prepared specimens, their holders and the required collectors fit inside the 900 mm-wide enclosure, this model provides a smaller installation envelope than the 600 L and 800 L cabinets.

Suitable inquiries include coated test panels, plated hardware and small component assemblies whose required exposure is salt fog. The selected method and evaluation criteria determine the test—not an industry label or a generic number of hours.

DERUI salt spray corrosion test chamber
Salt spray cabinet for laboratory corrosion exposure.
Laboratory task What makes the layout suitable
Routine checks of a defined finish Specimen preparation, mounting and evaluation can be repeated between runs.
Small component qualification The component and fixture fit without shielding required surfaces or interfering with collection.
Coated coupons from a process investigation Coupons use a common prescribed exposure, with documented preparation and specimen-level results.
A smaller footprint does not remove the utility requirements. Plan compressed air, power, water, exhaust and drainage before deciding where the chamber will stand.

Check the 900 × 600 × 500 mm Loading Envelope

Use the internal dimensions to build a top and side view of the proposed arrangement. The 270 L figure is geometric volume, not unrestricted usable space. Include holders, inclination, collector positions and clearance for fog exposure.

Coated coupons

Specify panel size, exposed face, quantity and required angle. Avoid overlapping faces or runoff onto neighboring panels.

Fasteners and small parts

Include the full tray or hanging-fixture drawing. Identify contact points and surfaces that must remain exposed.

Small assemblies

Include recesses, orientation and drainage. Check height with the support installed, not just the bare component.

The listed supports provide 15° or 30° positions. Use the angle prescribed for the specimen and procedure. Do not add stacked layers or pack the cabinet tightly simply because the overall dimensions appear to fit.

A useful inquiry includes specimen quantity, individual dimensions, total mass and the complete fixture envelope. If the same laboratory tests different sizes, show the most demanding arrangement as well as the routine one.

270L Salt Spray Chamber Configuration

The following parameters apply to the DR-H304-270. Dimensions are presented as width × depth × height. Select the required exposure and specimen layout together when specifying the equipment.

Технические характеристики DR-H304-270
Модель DR-H304-270; 90-type salt spray chamber
Nominal volume 270 L geometric enclosure volume
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 900 × 600 × 500 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 1460 × 960 × 1150 mm; additional operating and service clearances required
Cabinet temperature range Room temperature +5°C to 55°C
Air-saturator temperature range Room temperature +10°C to 70°C
Равномерность температуры ≤2°C
Колебания температуры ±0.5°C
Коэффициент сбора тумана 1–2 mL per 80 cm² per hour; listed as a 16-hour average. Apply the measurement interval required by the adopted procedure
Spray operation Continuous or periodic spray
Test timer 1–9999, with hours/minutes/seconds settings
Cycle timer 1–99, with hours/minutes/seconds settings
Specimen rack inclination 15° or 30°; use the orientation required by the procedure
Air pressure specification Listed as 2.00 ±0.01 kg/cm². Define the connection and regulator measurement point in the installation specification
Method selection Specify NSS, AASS or CASS and the required compatible configuration before ordering

Nominal volume includes space later occupied by supports and clearances. Agree the specimen arrangement and acceptance checks for the selected exposure. Temperature settings and spray timing are not proof of controlled humidity or drying-stage capability.

Specify Salt Fog Operation Without Adding Unneeded Climate Functions

Continuous spray and periodic spray are distinct operating choices. Define spray duration, inspection access and the treatment of interruptions in the test programme. A spray-off interval does not demonstrate a controlled drying or humidity stage.

Требование Decision before purchase
NSS exposure Define the adopted method, solution preparation, operating checks and product-specific endpoint.
AASS or CASS exposure Specify chemistry compatibility, solution handling, operating conditions and cleaning requirements.
Cyclic corrosion with climate stages Assess the complete environmental sequence and transitions; these functions are not established by this cabinet’s spray timer.

The ISO 9227 scope distinguishes NSS, AASS and CASS. Exposure duration, specimen details and result interpretation must come from the applicable product requirement. NSS is a neutral exposure; salt fog testing does not reproduce every condition of a marine service environment.

For a primary CASS requirement, see the CASS corrosion test chamber. For method selection and result interpretation, use the salt spray testing guide. This page focuses on selecting and installing the 270 L cabinet.

A Repeatable Routine for Small Laboratory Runs

  1. Identify the specimens. Record finish, batch, preparation, exposed face and any edge protection or scribe.
  2. Document the layout. Photograph positions, supports and collectors before exposure.
  3. Verify the setup. Apply the required temperature, solution and fog checks rather than rely on the timer alone.
  4. Record the exposure. Keep inspection access, replenishment, faults and interruptions associated with the run.
  5. Evaluate the stated endpoint. Use the specified handling and assessment method, with individual results for each specimen.

Fog collection, temperature verification and instrument calibration are different checks. Keep collector readings separately with their positions and measurement interval. Do not use one acceptable average to conceal an unsuitable location.

A result such as “no red rust” needs the duration, surfaces assessed, preparation and evaluation basis. Salt spray hours do not provide a universal conversion to years in service. When comparing repeat checks of the same finish, retain the same preparation and assessment conditions.

If exported records, automatic logging or chemistry monitoring are needed, include the channels and format in the quotation. These functions are not implied by the published timer settings.

Fit the Equipment and Connections Into Your Laboratory

The cabinet dimensions are 1460 mm wide × 960 mm deep × 1150 mm high. Check the delivery route, cover opening and service access with the installation drawing. A floor-plan rectangle alone is not the complete space requirement.

Site item Planning check
Compressed air Required pressure, delivery, air treatment, regulator location and connections.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Voltage, frequency, phase, circuit protection and cable requirements for the ordered configuration.
Water and solution preparation Method-appropriate water quality, filling access and space for preparing the required chemistry.
Exhaust and drainage Corrosion-resistant connection routes, ventilation and facility-approved effluent handling.
Access and ambient conditions Clearance for cover movement, inspection and maintenance; laboratory ambient suitable for the required operating temperature.

The chamber’s room-temperature +5°C lower limit depends on the laboratory ambient and does not indicate refrigeration. Check that the required setpoint is achievable at your installation conditions.

Specify reservoir capacity, filling arrangements and any requested automatic replenishment in the proposal. Do not estimate unattended duration from cabinet volume. Establish solution inspection and maintenance using the operating instructions.

Agree What the Delivered Chamber Must Demonstrate

Exposure checks

Required spray mode, temperature checks and fog collection with the agreed specimen layout.

Equipment scope

Mounting arrangement, utility connections, accessories, alarms and requested record functions.

Handover evidence

Operating and maintenance instructions, calibration scope and the agreed acceptance report.

Equipment acceptance and product approval are separate decisions. A chamber demonstration does not certify the corrosion resistance of your parts. Define the specimen test and acceptance criterion in the laboratory programme.

For routine maintenance, inspect solution delivery, atomization, collectors and drains. Clean using the equipment instructions for the selected chemistry. Include nozzle inspection in the maintenance schedule and request a demonstration of any specified automatic solution-control functions.

Need More Space? Compare the Complete Layout

Опция Internal W × D × H Selection reason
DR-H304-270 / 270 L 900 × 600 × 500 mm Laboratory specimens and smaller fixture arrangements that fit the required exposure layout.
DR-H304-120 / 600 L 1200 × 1000 × 500 mm Additional width and depth for larger fixtures or specimen groups.
DR-H304-160 / 800 L 1600 × 1000 × 500 mm More horizontal space for batch loading.

All three listed cabinets have 500 mm internal height. Moving to the 600 L or 800 L model does not solve every height constraint; include supports and the required orientation in your comparison.

Review the DR-H304 corrosion chamber series for additional size choices, or return to the salt spray equipment category for the full range. Larger dimensions do not automatically add a different exposure method.

270L Laboratory Salt Spray Chamber FAQs

Does the 90-type name mean 90 litres?

No. This page covers DR-H304-270. Its 900 × 600 × 500 mm internal dimensions correspond to 270 L nominal geometric volume.

Is it a benchtop chamber?

Do not assume so. The listed external dimensions are 1460 × 960 × 1150 mm in width × depth × height. Plan the installed location and connections using the equipment drawing.

How many coupons or parts fit inside?

Use the complete specimen and fixture layout, including inclination, clearances and collectors. A sample count cannot be established from 270 L alone.

Can small painted or plated specimens be tested?

Yes, with a procedure appropriate to the finish and ordered configuration. Define preparation, exposure and acceptance before starting the test.

Does periodic spray include humidity and drying control?

No. The timer establishes spray sequencing, not verified multi-stage climate capability.

Are automatic solution mixing and data export included?

These are not established by the published timer and spray specifications. Include the functions and required record format explicitly in the quotation.

Can it operate below room temperature?

The published cabinet range starts at room temperature +5°C. It does not establish active cooling or low-temperature cycling.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Provide the required method and edition, specimen dimensions and quantity, fixture layout, exposure duration, evaluation needs and laboratory utilities.

BUILD YOUR LABORATORY CORROSION SETUP

Start With Your Samples.
Request the Right 270L Configuration.

Send specimen dimensions, quantity and the required exposure. Include your fixture layout and laboratory utilities to review the DR-H304-270 installation and quotation.

Request My 270L Salt Spray Proposal →

FacebookLinkedInXRedditWhatsApp

DR-H304-270 Technical Parameters

The following parameters apply to the DR-H304-270. Dimensions are presented as width × depth × height. Select the required exposure and specimen layout together when specifying the equipment.

Технические характеристики DR-H304-270
Модель DR-H304-270; 90-type salt spray chamber
Nominal volume 270 L geometric enclosure volume
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 900 × 600 × 500 mm
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits 1460 × 960 × 1150 mm; additional operating and service clearances required
Cabinet temperature range Room temperature +5°C to 55°C
Air-saturator temperature range Room temperature +10°C to 70°C
Равномерность температуры ≤2°C
Колебания температуры ±0.5°C
Коэффициент сбора тумана 1–2 mL per 80 cm² per hour; listed as a 16-hour average. Apply the measurement interval required by the adopted procedure
Spray operation Continuous or periodic spray
Test timer 1–9999, with hours/minutes/seconds settings
Cycle timer 1–99, with hours/minutes/seconds settings
Specimen rack inclination 15° or 30°; use the orientation required by the procedure
Air pressure specification Listed as 2.00 ±0.01 kg/cm². Define the connection and regulator measurement point in the installation specification
Method selection Specify NSS, AASS or CASS and the required compatible configuration before ordering

Nominal volume includes space later occupied by supports and clearances. Agree the specimen arrangement and acceptance checks for the selected exposure. Temperature settings and spray timing are not proof of controlled humidity or drying-stage capability.

DR-H304-270 Questions and Answers

Does the 90-type name mean 90 litres?

No. This page covers DR-H304-270. Its 900 × 600 × 500 mm internal dimensions correspond to 270 L nominal geometric volume.

Is it a benchtop chamber?

Do not assume so. The listed external dimensions are 1460 × 960 × 1150 mm in width × depth × height. Plan the installed location and connections using the equipment drawing.

How many coupons or parts fit inside?

Use the complete specimen and fixture layout, including inclination, clearances and collectors. A sample count cannot be established from 270 L alone.

Can small painted or plated specimens be tested?

Yes, with a procedure appropriate to the finish and ordered configuration. Define preparation, exposure and acceptance before starting the test.

Does periodic spray include humidity and drying control?

No. The timer establishes spray sequencing, not verified multi-stage climate capability.

Are automatic solution mixing and data export included?

These are not established by the published timer and spray specifications. Include the functions and required record format explicitly in the quotation.

Can it operate below room temperature?

The published cabinet range starts at room temperature +5°C. It does not establish active cooling or low-temperature cycling.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Provide the required method and edition, specimen dimensions and quantity, fixture layout, exposure duration, evaluation needs and laboratory utilities.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
СообщениеСообщение

Запросить коммерческое предложение