Boden 1, Nr. 3, Shugang Avenue, Hongmei Town, Dongguan City, Guangdong Province, China

Hersteller von Umwelttestkammern seit 20 JahrenMehr als 3000 Kunden weltweit geliefert           E-Mail: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

DR-H508 Sand-Testkammer

Das DERUI DR-H508 custom automotive sand test chamber is configured around the vehicle component, installed orientation, fixture, powered interfaces, pressure condition and selected dust-test procedure. It is intended for projects that do not fit the fixed 1,000 L DR-H508-2 configuration.

Platform DR-H508 custom configuration
Primary Application Automotive lighting, controllers, instruments, locks, seals and assemblies
Konstruktion SUS304 interior, coated cold-rolled-steel exterior and funnel dust-recovery path
Published Controls 0–99 h dust, impact and load timers; 0–9999 h working-hours counter
Custom Inputs Workspace, fixture, power, signals, pressure connection and inspection method
Before Production Approve drawings, interfaces, programme terminology and FAT criteria
Sicher und zuverlässig
Hochwertig hergestellt
Qualitätssicherung
Anpassung
NachrichtWhatsApp
Hotline-Nummer 15580327593
  • Produktdetails
  • Technische Parameter
  • FAQ
  • Kontaktieren Sie uns
Custom Dust Testing for Automotive Components

DR-H508 Custom Automotive Sand Test Chamber

Configure the workspace, fixture, specimen power, feedthroughs and operating sequence around vehicle lighting, instrument housings, electrical covers, steering components, locks, seals and other automotive assemblies.

Custom-product position: this page is for applications that do not fit the published 1 m³ standard configuration or require dedicated mounting, powered operation and monitoring. Exact dimensions and performance belong in the approved technical agreement.
PlatformDR-H508 custom configuration
Primary marketAutomotive and electromechanical components
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limitsPublished SUS304 stainless steel
Configuration basisSpecimen + method + fixture + interfaces

Configure Around the Actual Automotive Assembly

Lighting and optical housings

Define lamp orientation, mounting points, powered state, heat output, ventilation paths and post-test optical or electrical checks.

Controllers and instruments

Specify connectors, communication, monitoring channels, cable glands and whether functional operation continues during dust exposure.

Mechanical parts and seals

Provide the real installation orientation, motion or load state, sealing surfaces and agreed internal inspection method.

Published DR-H508 Construction Features

Assembly Published feature Custom project decision
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits SUS304-Edelstahltür Confirm dimensions, thickness, shelves, floor loading and cleaning access.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Cold-rolled steel with baked-paint finish Confirm colour, footprint, doors and destination environment.
Dust-blowing motor Stainless-steel shell, sealed construction, low-noise/high-speed description Confirm actual airflow function against the selected method; do not infer a MIL blowing-sand profile.
Internal dust path Funnel-shaped lower shell with adjustable vibration cycle Confirm recovery path, dead zones and specimen clearance.
Observation Door-mounted observation window Confirm required size, lighting and safe viewing procedure.
Main accessories Dust fan, vibration motor, heating tube and filter screen Confirm supplied quantity, material, maintenance access and spare parts.
Vacuum components Vacuum gauge, filter, gas flowmeter and quick connector Confirm range, accuracy, pump inclusion and specimen connection.

Published Timing Functions

Controller item Published range What must be defined
Sandblasting/dust-blowing time 0–99 h Active exposure stage and circulation sequence.
Impact time 0–99 h The page does not define the physical function; clarify the exact controlled output before ordering.
Load time 0–99 h Specimen power timing, electrical load and safety isolation.
Accumulated working hours 0–9999 h Maintenance counter, reset permission and record requirement.
Terminology check: “sandblasting time” and “impact time” are literal published labels, but they do not prove abrasive sandblasting or a specific impact mechanism. The quotation should identify the controlled component and sequence.

Custom Fixture and Interface Design

Specimen envelope

Provide the largest dimensions, mass, quantity and loading method.

Installed orientation

Replicate vehicle position, fasteners, seals, openings and cable direction.

Powered operation

Define voltage, current, maximum heat, duty cycle and isolation response.

Monitoring

List temperature, voltage, current, communication and functional channels.

Pressure connection

Confirm enclosure category, free volume, target depression, flow limit and connection.

Post-test checks

Define cleaning restrictions, internal inspection and electrical or mechanical acceptance.

DR-H508 Custom Chamber Reference Image

DR-H508 Sand-Testkammer

Final workspace, fixture, ports, powered interfaces, dust circuit and vacuum components must follow the approved automotive test configuration.

Three Dust Pages with Three Different Jobs

Page Primary role Do not use it for
Dust ingress test chamber Method-led IP5X/IP6X selection, enclosure category and custom chamber sizing A fixed model specification when the buyer has already selected 1 m³.
1000 L sand dust test chamber Published DR-H508-2 dimensions, timers, dust loading, power and standard hardware Non-standard large parts or dedicated automotive fixtures.
This custom automotive page Fixture-led automotive components, powered operation, ports and custom workspace A generic duplicate description of IP5X/IP6X or the fixed 1,000 L specification.

Standards Must Be Selected Before Design

Reference Potential relevance Boundary
ISO 20653 Degrees of protection for electrical equipment in road vehicles Confirm designation, edition, enclosure category, pressure condition and acceptance.
IEC 60529 General enclosure IP protection Use the exact first-digit procedure; water-protection ratings require separate equipment.
GB/T 2423.37 / IEC 60068-2-68 Sand and dust environmental test references Confirm the applicable method, particle specification, airflow and severity before claiming capability.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Tailored blowing dust and blowing sand procedures Requires a separately verified particle-feed and airflow configuration; DR-H508 naming alone is insufficient.

Recommended Custom-Project FAT

Mechanical fit and handling

Load the representative fixture or dimensional dummy; verify door, clearance, shelf/floor load, ports and service access.

Sequence and interfaces

Run dust, vibration, heating, load timing, pressure connection, specimen power and monitoring through the agreed programme.

Protection and records

Verify overload, short circuit, grounding, over-temperature, alarm shutdown, accumulated time and required documentation.

Information Needed for a Custom Proposal

Topic Provide
Automotive part Drawing, dimensions, mass, quantity, installed orientation and handling points.
Method Standard, edition, designation/procedure, dust and duration.
Fixture Mounting points, allowable materials, rotation/motion if any and access clearance.
Powered interfaces Voltage, current, heat, duty cycle, connectors, communications and monitoring.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Enclosure category, free volume, target depression, flow and pump requirement.
cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits Inspection, functional checks, FAT points, data and report format.

Häufig gestellte Fragen

Why keep this page if DERUI already has two dust-chamber pages?

This page serves custom automotive projects requiring dedicated fixtures, powered interfaces, monitoring or non-standard workspace. The other pages handle method selection and the fixed 1,000 L configuration.

Are the chamber dimensions fixed?

No fixed dimensions are published on this page. Size the chamber from the specimen envelope, fixture, circulation clearance and loading access.

What does the published “impact time” control?

The existing page does not define it clearly. The quotation must identify the physical output and sequence before the term is used as a product claim.

Are powered automotive components supported?

They can be considered only after specimen voltage, current, heat, feedthroughs, monitoring and isolation are engineered into the quoted configuration.

Does this chamber automatically support MIL-STD-810 Method 510?

No. The exact procedure, particle feed, airflow, temperature and controls require separate confirmation.

What evidence should be requested before shipment?

Request the approved drawing, configuration list, representative-load FAT, interface checks, protection tests, manuals, wiring information and agreed calibration records.

Build the Chamber Around the Vehicle Component

Send the part drawing, installed orientation, powered interfaces, pressure condition and test method. DERUI can return a custom chamber, fixture and FAT configuration for review.

Request an Automotive Dust Test Review

FacebookLinkedInXRedditWhatsApp
Artikel Details
Modell DR -H508-1
Innere Abmessungen (D×B×H) mm 800×800×800
Äußere Abmessungen (D×B×H) mm 1280×1060×1800
Durchmesser des Metallgitternetzdrahts 50 μm
Nennabstand zwischen den Drähten 75 μm
Staubverbrauch 2 kg/m³
Vibrationszeit 99 Minuten und 59 Sekunden
Testzeit 99 Stunden und 59 Minuten
Testprobe Steckdose Staubdichte Steckdose, AC220V, 16A
Controller Touchscreen-Display gesteuert durch importiertes PLC-Programm, mit Anzeige von Arbeitszeit und anderen Informationen auf Chinesisch
Vakuumsystem Ausgestattet mit Manometer, Luftfilter, Druckregelungst-Stück, Verbindungsschlauch (Vakuumpumpe separat bereitzustellen, bitte bei Bestellung angeben)
Umluftventilator Geschlossener Legierung-Niedriggeräuschmotor, Mehrblatt-Zentrifugalventilator
Staubheizungssystem Edelstahl-Mika-Plattenheizmanschette
Netzspannung AC380V ± 10%, T3T, 50Hz, Dreiphasen-Fünf-Leiter-System
Sicherheitsvorkehrungen Leckageschutz, Kurzschlussschutz, Übertemperaturschutz, Motorkühlungsschutz, Überstromschutz

1. Was ist eine Sand- und Staubprüfkammer?
Eine Sand- und Staubprüfkammer ist ein Versuchssystem, das verwendet wird, um die Leistung von Geräten in einer sandigen und staubigen Umgebung zu testen.

2. Was ist der Hauptzweck der Sand- und Staubprüfkammer?
Sie wird hauptsächlich verwendet, um die Zuverlässigkeit und Haltbarkeit von elektronischen, automobilen und mechanischen Geräten unter Sand- und Staubbedingungen zu testen.

3, Wie wählt man die richtige Sand- und Staubtestkammer aus?
Das am besten geeignete Modell kann basierend auf den Testanforderungen, der Gerätegröße und der Hauptanwendungsbranche ausgewählt werden.

4, Welche Prüfstandards gelten für Sand- und Staubtestkammern?
Sie umfassen internationale Prüfstandards wie MIL-STD-810 und IEC 60068, die die Testanforderungen verschiedener Produkte erfüllen können.

5, Muss die Sand- und Staubtestkammer regelmäßig gewartet werden?
Ja, regelmäßige Wartung kann die Stabilität der Ausrüstung und die Genauigkeit des Tests gewährleisten.

6, Welche Vorteile bietet die Verwendung einer Sand- und Staubtestkammer?
Sie kann Schwachstellen von Produkten in extremen Umgebungen im Voraus erkennen und somit Risiken nach der Markteinführung reduzieren.

7, Wie lange dauert der Test ungefähr?
Die Testdauer variiert je nach Produkttyp und den erforderlichen Prüfstandards und liegt in der Regel zwischen 4 Stunden und 48 Stunden.

8, Wie kann man After-Sales-Service für die Sand- und Staubtestkammer erhalten? Kunden können den After-Sales-Service über unsere Kundenhotline oder die offizielle Website erhalten.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
NachrichtNachricht

Anfrage für ein Angebot