Piso 1, No. 3, Avenida Shugang, Vila Hongmei, Cidade de Dongguan, Província de Guangdong, China

Fabricante de câmaras de teste ambiental há 20 anosMais de 3000 entregas a clientes em todo o mundo           Email: shirley@deruitest.com
WhatsApp Consultation:+86 135 2795 8363

Câmara de Clima à Prova de Água IPX56

A DERUI H503-2 IPX5 / IPX6 water jet test chamber combines two nozzle configurations for evaluating enclosure resistance to water jets. Its 1000 mm workspace and 500 mm rotating table support method-defined specimen positioning, while the PLC touch screen provides the test-control interface.

Modelo H503-2
Tipo de teste IPX5 / IPX6 water-jet exposure
IPX5 configuration 6.3 mm nozzle; 12.5 L/min ±5%
IPX6 configuration 12.5 mm nozzle; 100 L/min ±5%
Internal workspace 1000 × 1000 × 1000 mm (W × D × H)
Specimen table 500 mm diameter; adjustable rotation speed
Control and supply PLC touch screen; AC 380 V, 50 Hz, three phase
Before quotation Specify required IP code, specimen/fixture, jet coverage, powered state and water utilities
Seguro e fiável
bem construído
Garantia de qualidade
personalização
MensagemWhatsApp
Número de Linha Direta 15580327593
  • Detalhes do Produto
  • Parâmetros técnicos
  • Perguntas Frequentes
  • Contacte-nos
Model H503-2

One Enclosed System for IPX5 and IPX6 Water-Jet Exposure

The H503-2 combines two water-jet configurations in a stainless-steel test enclosure: a 6.3 mm nozzle with 12.5 L/min delivery for the published IPX5 setup, and a 12.5 mm nozzle with 100 L/min delivery for the published IPX6 setup. A 500 mm rotating table helps expose different specimen surfaces at the defined nozzle distance.

The chamber supplies the water exposure. The governing standard, product specification or customer procedure defines specimen orientation, accessible surfaces, duration, operating state and acceptance criteria. Passing the chamber program does not by itself prove product compliance.

Direct answer: select H503-2 when both jet levels are required and the complete specimen and fixture fit the 1000 mm workspace and 500 mm table. Use separate equipment for drip, oscillating-tube, immersion, automotive K-code or high-pressure/high-temperature jet procedures unless those functions are explicitly added and verified.

Confirmed model data

H503-2 Technical Specifications

Use these published values for preliminary assessment and reconfirm the ordered water circuit, drawing and utilities in the technical agreement.

Item IPX5 setup IPX6 setup
Nozzle internal diameter 6.3 mm 12.5 mm
Water delivery rate 12.5 L/min ±5% 100 L/min ±5%
Substantial-stream core Approx. 40 mm diameter at 2.5 m Approx. 120 mm diameter at 2.5 m
Spray distance 2.5–3 m from nozzle to enclosure surface
Duration basis 1 min per square metre of enclosure surface likely to be sprayed; minimum 3 min
Internal workspace 1000 × 1000 × 1000 mm (W × D × H), customization stated
External dimensions 1400 × 1200 × 3500 mm (W × D × H)
Specimen table 500 mm diameter; adjustable rotation speed
Controlador Tela sensível ao toque PLC
Construção SUS304 stainless-steel interior; stainless-steel exterior
Fonte de alimentação AC380 V, 50 Hz, three phase

Additional test requirements: include any water-temperature control, specimen electrical interface, data recording or remote-monitoring requirement in your request. The configuration proposal will identify the supplied functions and acceptance checks. This water-jet configuration does not establish chamber-air temperature or humidity control.

Choose the specified exposure

IPX5 and IPX6 Are Separate Water-Jet Tests

IPX5 and IPX6 use different nozzle and delivery-rate arrangements. Select the exposure and test sequence required by the adopted standard, product specification or customer program. Where both tests are explicitly requested, document each setup and result; a separate IPX5 run should not be treated as an automatic additional requirement in every IPX6 program.

IPX5 configuration

The published H503-2 setup uses the smaller nozzle and lower delivery rate. Confirm distance, duration, coverage and specimen condition from the controlled test document.

  • 6.3 mm nozzle
  • 12.5 L/min ±5%
  • Approx. 40 mm stream core at 2.5 m
  • Defined accessible surfaces and orientation

IPX6 configuration

The larger nozzle and higher delivery rate produce a more powerful jet. Fixture strength, specimen stability, splash containment and water supply capacity need separate review.

  • 12.5 mm nozzle
  • 100 L/min ±5%
  • Approx. 120 mm stream core at 2.5 m
  • Higher water demand and mechanical loading
Terminology matters: IPX6 is not automatically equivalent to automotive IPX6K or IPX9K. Obtain the exact edition and code cited by the customer before selecting the nozzle and procedure.
Repeatable execution

From Nozzle Verification to Ingress Evaluation

Identify the specimen

Record model, enclosure state, seals, connectors, vents and pre-test condition.

Mount as specified

Reproduce orientation and supports without masking surfaces that must receive water.

Select the nozzle

Install the required IPX5 or IPX6 nozzle and prevent an incorrect program selection.

Verify exposure

Measure flow, establish distance, set duration and confirm table movement and coverage.

Run and monitor

Record powered state, interruptions, flow deviations and any abnormal specimen response.

Inspect and decide

Open, drain and evaluate only as the method requires; document ingress and functional results.

Recommended record: standard and edition, IP code, specimen photographs, fixture and orientation, nozzle ID, measured delivery rate, distance, program, exposure time, operating state, deviations, internal inspection and acceptance decision.

Procurement checklist

Size the Entire Water-Test System

Nozzle compliance is only one part of the purchase. Confirm specimen clearance, water capacity, fixture, drainage and laboratory utilities before approving the chamber.

cURL Too many subrequests by single Worker invocation. To configure this limit, refer to https://developers.cloudflare.com/workers/wrangler/configuration/#limits

Check specimen, fixture, cable routing, rotation and nozzle clearance inside the 1000 mm workspace.

Fornecimento de água

Define inlet capacity, tank volume, filtration, recirculation, make-up water and the 100 L/min IPX6 demand.

Drainage and containment

Review floor drain, overflow protection, splash control, cleaning access and discharge restrictions.

Powered testing

Specify feedthroughs, voltage, current, control sequence, leakage protection and required monitoring.

Laboratory installation

Verify AC380V three-phase power, equipment height and access route, floor load, water and service clearance.

Acceptance checks: workspace and table dimensions, both nozzle diameters, measured delivery rates, distance, timer, table rotation, controller programs, water containment, safety interlocks, ordered options and documentation.

Plan the IPX6 Water Circuit and Full Jet Path

Separate delivery from consumption

At the listed 100 L/min delivery, a three-minute exposure passes approximately 300 L through the nozzle. That is cumulative delivered water, not automatically the fresh-water consumption or minimum tank volume.

Size the selected circuit

For a recirculating arrangement, evaluate return flow, splash loss, filtration, make-up water and usable tank level. For once-through operation, review supply and discharge capacity. Specify the actual circuit in the proposal.

Verify the installed distance

The listed cabinet workspace is 1000 mm, while the method-facing nozzle distance is 2.5–3 m. Check nozzle placement, enclosure surface reference and actual jet path on the approved drawing and during acceptance.

A rotating table does not guarantee every required face is exposed. Review fixture masking, cable routes, specimen stability and the directions required by the test plan. Agree a loaded demonstration with the intended assembly.

Buyer questions

H503-2 IPX5/IPX6 Chamber FAQs

Does H503-2 include temperature and humidity control?

The listed configuration establishes IPX5/IPX6 water-jet testing, not chamber-air temperature or humidity control. Specify water-temperature conditioning separately if your procedure requires it.

Must every IPX6 program also include a separate IPX5 run?

No. Determine the required test sequence and rating assignment from the adopted standard and product requirement. If the customer explicitly requests both exposures, use each specified nozzle, delivery rate, distance and evaluation sequence.

Can H503-2 perform IPX6K or IPX9K?

These are distinct automotive water-test designations. The listed 6.3 mm and 12.5 mm nozzle setups do not by themselves establish those capabilities. Provide the exact code and method for a separate configuration review.

Does passing mean absolutely no water can enter?

Not universally. The applicable product or customer requirement defines harmful ingress and the necessary inspection, functional or electrical checks. Document the result against that criterion.

Can products operate during water-jet testing?

Specify specimen voltage, current, cables, switching sequence and monitoring. Powered operation requires appropriate electrical interfaces and wet-test protection in the ordered configuration; it is not established by the chamber supply voltage alone.

What is needed for an accurate quotation?

Provide the required standard edition and IP code, specimen dimensions and mass, fixture and orientation, surfaces to expose, powered state, water conditions, acceptance checks and site utilities. Include any recording/export or monitoring requirement.

Confirm the Required IPX5 and IPX6 Configuration

Send the test document, specimen drawing, powered state, exposure surfaces, utilities and acceptance checks.

Request a Water-Test Review →

FacebookLinkedInXRedditWhatsApp

Item

Especificação

Tamanho da câmara interna (L*A*P)

1000*1000*1000mm (pode ser personalizado)

Tamanho da câmara externa (L*A*P)

1400*1200*3500mm

Código IP

IPX5

IPX6

Diâmetro interno do bocal     

6.3mm

12.5mm

Taxa de entrega

12.5l/min±5%

100l/min±5%

Núcleo do fluxo substancial

Círculo de aproximadamente 40mm de diâmetro a 2,5m de distância da boquilha

Círculo de aproximadamente 120mm de diâmetro a 2,5m de distância da boquilha

Material da câmara

Interno: aço inoxidável SUS304, externo: aço inoxidável

Duração do teste por metro quadrado de área de superfície do recinto que provavelmente será pulverizado

1 min

Duração mínima do teste

3 min

Controlador

Tela sensível ao toque PLC

Distância da boquilha à superfície do recinto

Entre 2,5m e 3m

Mesa rotatória de amostras

Diâmetro de 500mm, velocidade de rotação ajustável

Potência

AC380V, 50Hz, trifásico

H503-2 IPX5 / IPX6 Water Jet Chamber FAQ

Does H503-2 include temperature and humidity control?

The listed configuration establishes IPX5/IPX6 water-jet testing, not chamber-air temperature or humidity control. Specify water-temperature conditioning separately if your procedure requires it.

Must every IPX6 program also include a separate IPX5 run?

No. Determine the required test sequence and rating assignment from the adopted standard and product requirement. If the customer explicitly requests both exposures, use each specified nozzle, delivery rate, distance and evaluation sequence.

Can H503-2 perform IPX6K or IPX9K?

These are distinct automotive water-test designations. The listed 6.3 mm and 12.5 mm nozzle setups do not by themselves establish those capabilities. Provide the exact code and method for a separate configuration review.

Does passing mean absolutely no water can enter?

Not universally. The applicable product or customer requirement defines harmful ingress and the necessary inspection, functional or electrical checks. Document the result against that criterion.

Can products operate during water-jet testing?

Specify specimen voltage, current, cables, switching sequence and monitoring. Powered operation requires appropriate electrical interfaces and wet-test protection in the ordered configuration; it is not established by the chamber supply voltage alone.

What is needed for an accurate quotation?

Provide the required standard edition and IP code, specimen dimensions and mass, fixture and orientation, surfaces to expose, powered state, water conditions, acceptance checks and site utilities. Include any recording/export or monitoring requirement.

WhatsAppWhatsApp
WhatsAppWhatsApp
WhatsApp
MensagemMensagem

Solicitar Orçamento